Manual Goodman Mfg GSX

56 pages 0.73 mb
Download

Go to site of 56

Summary
  • Goodman Mfg GSX - page 1

    • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. RT6113005r9 August 2010 Copyrigh t © 2007 - 2010 Goodman Manufacturin ...

  • Goodman Mfg GSX - page 2

    PRODUCT IDENTIFICA TION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause p ...

  • Goodman Mfg GSX - page 3

    PRODUCT IDENTIFICA TION 3 The United States Environmental Protection Agency (“EPA”) has issued various regulations re- garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by ju ...

  • Goodman Mfg GSX - page 4

    PRODUCT DESIGN 4 GSX/VSX13 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. Select GSX13 models are available in 208/230 and 460 volt 3-phase applications. These models use R-410A refrigerant. The condenser air is pulled through the condenser coil by a direct ...

  • Goodman Mfg GSX - page 5

    PRODUCT DESIGN 5 DIMENSIONS W D H M ode l D im en s io n s - W x D x H G S X 1 3 0181A* 26" x 26" x 3 2¼ " G S X 1 3 0241A* 26" x 26" x 3 2¼ " G S X 1 3 0301A* 26" x 26" x 3 2¼ " G S X 1 3 0361A* 29" x 29" x 32¼ G S X 1 3 0421A* 29" x 29" x 3 4¼ " G S X 1 3 0481A* 29" x ...

  • Goodman Mfg GSX - page 6

    CONDENSING UNIT SPECIFICA TIONS 6 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. GSX130[18-60]1A* (1) Wire size should be determined in acordance with National Electrical C ...

  • Goodman Mfg GSX - page 7

    CONDENSING UNIT SPECIFICA TIONS 7 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. GSX130[18-60]1B* (1) Wire size should be determined in acordance with National Electrical C ...

  • Goodman Mfg GSX - page 8

    CONDENSING UNIT SPECIFICA TIONS 8 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. GSX130181C* G SX1 3 0 1 8 1 C * Co ol i ng C apa c ity , BT UH 18, 00 0 SEER / EER 1 3 / 1 ...

  • Goodman Mfg GSX - page 9

    CONDENSING UNIT SPECIFICA TIONS 9 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. (1) Wire size should be determined in acordance with National Electrical Codes. Extensive w ...

  • Goodman Mfg GSX - page 10

    CONDENSING UNIT SPECIFICA TIONS 10 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. VSX130[18-60]1A* (1) Wire size should be determined in acordance with National Electrical ...

  • Goodman Mfg GSX - page 11

    CONDENSING UNIT SPECIFICA TIONS 11 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. VSX130[18 & 60]1B* (1) Wire size should be determined in acordance with National Elect ...

  • Goodman Mfg GSX - page 12

    12 COOLING PERFORMANCE DA T A GSX130181A* EXPA NDED PERFORMA NCE DA TA COOLING OPERAT ION MODEL: GSX130181A * / CA* F1824*6** / ZP16K5E-PFV Out door A mbient T emperat ure 65 75 85 95 105 115 Enteri ng In door W et Bul b Temper ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 36 77 15 96 36 77 1 MBh 17.6 18.3 20.0 ...

  • Goodman Mfg GSX - page 13

    13 COOLING PERFORMANCE DA T A GSX130181A* E X P A ND ED PE RF ORM A N CE DA T A C OO L IN G OP E RA T ION MOD EL : G S X 13 0181AA / C A* F 1824 * 6* * / Z P 1 6K 5E-P F V O utdoo r Am bi ent Tempe rat ure 65 75 8 5 95 1 05 11 5 E nt e ri ng I ndo or We t B ul b Te mp e rat ur e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 9 6 3 6 77 15 9 6 3 6 ...

  • Goodman Mfg GSX - page 14

    14 COOLING PERFORMANCE DA T A GSX130241A* EXPA NDED PERF ORMA NCE DA TA COOLIN G OPE RA TION MOD EL: GSX1 30241A * / CA *F18 24*6** / ZP20 K5-PF V Outdoor A mbient T empera ture 65 75 85 95 105 115 Entering Indoor Wet Bul b T empera ture I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 77 15 96 36 77 15 96 36 77 1 MBh 22.5 23. 4 ...

  • Goodman Mfg GSX - page 15

    15 COOLING PERFORMANCE DA T A GSX130241A* EX PAN DE D P ER F O R M ANC E D ATA CO O L I NG O PE RAT IO N MOD E L : G S X 130241A A / C A* F 1824 * 6** / Z P 20K 5- P F V O utdoor Am bient Te mpera ture 65 75 8 5 9 5 105 1 15 E nt eri ng I ndo or We t B ul b T e m p e r at ur e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 ...

  • Goodman Mfg GSX - page 16

    16 COOLING PERFORMANCE DA T A GSX130301A* EXPA NDED PERFORMA NCE DA TA COOLING OPE RA TION MODEL: GSX130301 A * / CA *F3030*6** / ZP24K5E-PFV Outdoor A mbient Temperature 65 75 85 95 105 115 Ent erin g I ndoor W et Bu lb T empera ture I D B * A i r f l o w 5 96 3 6 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 1 5 96 36 77 15 96 36 77 1 MBh 27.8 28.8 ...

  • Goodman Mfg GSX - page 17

    17 COOLING PERFORMANCE DA T A GSX130301A* E XP A ND ED PE RF O RM A N CE DA T A COO LING OP E RAT I O N MOD E L : G SX 130301AA / C A * F 3030 * 6** / Z P 24K 5E -P FV O utdoor A mbi e nt T e m pe r a tur e 65 75 85 95 105 1 15 E nt e r i ng I ndo or We t B ul b Temp e r ature I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 9 6 3 6 77 1 5 9 6 3 6 ...

  • Goodman Mfg GSX - page 18

    18 COOLING PERFORMANCE DA T A GSX130361A* EXPA NDED PERFORMA NCE DA TA COOLING OPE RATION MODE L: GSX13 0361A* / CA *F4860*6* * / ZP31K 5E-PF V Outdoor A mbient Temperature 65 75 85 95 10 5 115 Entering I ndoor W et Bulb Temperature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15 96 36 77 15 96 36 77 1 MBh 34.3 35 .5 38 ...

  • Goodman Mfg GSX - page 19

    19 COOLING PERFORMANCE DA T A GSX130361A* EX PAN DE D P ER FO R MANC E D A TA C OOL ING OP ER ATION MOD E L : G S X 130361AA / C A* F4860 * 6* * / Z P 31K 5E -P F V O ut door A m bi e nt T e m pe r a ture 65 75 85 9 5 10 5 115 E nt e r i ng I ndo or Wet B ulb Te mp e r at ure I D B * A i r f l o w 5 9 6 36 77 15 9 6 36 7 7 15 9 6 3 6 77 1 5 9 6 3 6 ...

  • Goodman Mfg GSX - page 20

    20 COOLING PERFORMANCE DA T A GSX130421A* EXPA NDED PERFORMA NCE DA TA COOLING OP ERATIO N MODEL: GSX130421A* / CA *F4860*6 ** / ZP3 4K5-PFV Outdoor A mbient Temperature 65 75 85 95 105 11 5 Entering Indoor W et Bulb Temperature I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15 96 36 7 7 15 96 36 77 1 MBh 39. 2 40. 6 44. ...

  • Goodman Mfg GSX - page 21

    21 COOLING PERFORMANCE DA T A GSX130421A* EX P A N DE D P E R F OR MA NC E DA TA C O OLING OP E R A T IO N MOD EL : G SX130421AA / C A *F4860 *6** / Z P 34K 5- P F V O utd oor Am b i e n t Te m p era tu r e 65 7 5 8 5 95 105 11 5 E nter i ng I ndoor W et Bulb Te m pe r a t ur e I D B * A i r f l o w 5 9 6 36 77 15 96 36 7 7 15 9 6 3 6 77 15 9 6 3 6 ...

  • Goodman Mfg GSX - page 22

    22 COOLING PERFORMANCE DA T A GSX130481A* EXPA NDE D PERFORMA NCE DA TA COOLING OPE RA TION MOD EL : GSX1 304 8-1 A * / CA *F4860*6 ** / ZP39K 5E -PFV Outdoor A mbient Temperature 65 75 85 95 105 1 15 Entering Indoor W et Bulb Temperature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15 96 36 77 15 96 36 77 1 MBh 45.1 46 ...

  • Goodman Mfg GSX - page 23

    23 COOLING PERFORMANCE DA T A GSX130481A* EX PA N DE D P ER F O R M ANC E D ATA C OOLING OP E R AT IO N MOD E L : G S X 13 048- 1AA / C A* F 486 0* 6** / ZP 39K5E - P F V O u t d o o r A m bi en t T em p er at u re 65 75 85 95 10 5 115 E n t e ri n g In do o r W et B u lb T e m p era t ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 9 6 3 6 77 ...

  • Goodman Mfg GSX - page 24

    24 COOLING PERFORMANCE DA T A GSX130601A* EXPA NDED PERFORMA NCE DA TA COOLING OPER A TION MODEL : GSX130 601A * / CA *F4860*6* */ ZP51 K5E -PFV Outdoor Ambient Temperature 65 75 85 95 105 115 Entering I ndoor W et Bulb Tem perature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 36 77 15 96 36 77 1 MBh 55.9 57 . 9 63. ...

  • Goodman Mfg GSX - page 25

    25 COOLING PERFORMANCE DA T A GSX130601A* E XP A ND E D PE RFO RMA N CE DA T A C OOLIN G OP ER ATION MOD E L : G S X 130601A A / C A* F 4860 * 6** / Z P51K 5E -P FV O utdoor Am bi ent Tempe rat ur e 6 5 7 5 85 9 5 10 5 1 15 E nt eri ng Indo or We t B ul b Te mp e r at ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 7 7 15 ...

  • Goodman Mfg GSX - page 26

    26 COOLING PERFORMANCE DA T A GSX130181B*/VSX130181A* M O DEL : G S X 1 301 81B * / C A*F1 824 *6B * EX PAN DE D P ER FO R M ANC E D ATA COO L IN G OP E RATION O utdoo r Am bi e n t Te m perat ur e 65 75 8 5 95 1 05 11 5 E n te ri ng Ind o or W e t B ulb Te mp era tu re I D B * A i r f l o w 5 96 36 77 1 5 9 6 36 77 15 96 3 6 77 15 9 6 3 6 7 7 15 9 ...

  • Goodman Mfg GSX - page 27

    27 COOLING PERFORMANCE DA T A M O DE L : G SX 1 301 8 1B * / C A*F 1 824 *6B * EX PAN DE D P ER FO R M AN C E D A TA COO L IN G OP E RATION O utdoor Am bie nt Te m pe rat ur e 6 5 7 5 85 9 5 10 5 1 15 E n t e ri ng I ndo or We t B ulb Te mp e r at ur e I D B * A i r f l o w 5 96 36 77 15 9 6 3 6 77 15 96 3 6 77 15 9 6 3 6 7 7 15 96 36 7 7 15 96 36 ...

  • Goodman Mfg GSX - page 28

    28 COOLING PERFORMANCE DA T A GSX130181C*/VSX130181B* M O DE L : V S X 130 1 81 B* / CA* F1 82 4*6 EX PAN DE D P ER F O R M ANC E D ATA CO OL ING O PERATION O u td o o r Amb i en t T em p er atu r e 65 75 8 5 9 5 105 1 15 E nt eri ng I ndo or We t B ul b Temp e rat ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 3 ...

  • Goodman Mfg GSX - page 29

    29 COOLING PERFORMANCE DA T A MO D EL: VSX13 0 1 8 1 B * / C A * F1 824 *6 EX PAN DE D P ER FO R M AN C E D ATA C O OLING O P E RA TION Ou tdoor Am bi ent Te m pera t ure 65 75 8 5 9 5 105 1 15 E nt eri ng I ndo or We t B ul b Temp e rat ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 3 6 77 15 96 36 77 1 MBh 18. ...

  • Goodman Mfg GSX - page 30

    30 COOLING PERFORMANCE DA T A GSX130241B*/VSX130241A* M O DEL : G S X 1 302 41B * / C A*F1 824 *6B * E XP A ND ED PE RF O RM A N CE DA T A C O OL IN G O P E RATION O utdoor Am bi e nt Te m pera ture 65 75 8 5 9 5 105 1 15 E nt eri ng Indo or We t B ulb Temp e r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 7 7 15 96 3 ...

  • Goodman Mfg GSX - page 31

    31 COOLING PERFORMANCE DA T A M O DE L: G S X 1 302 41B * / C A*F 1 82 4 * 6B * E X P A ND E D P E RF ORM A N CE DA TA C O OL I NG O P E RATI ON O utdoor Am bi e nt Te m pera t ure 65 75 8 5 9 5 105 1 1 5 E nt eri ng Indo or Wet B ulb Temp e ra ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 3 6 77 15 96 36 77 1 ...

  • Goodman Mfg GSX - page 32

    32 COOLING PERFORMANCE DA T A GSX130301B*/VSX130301A* M O D E L : GS X 13 0 30 1 B* / CA * F 30 3 0* 6 B* E XP A ND E D PE RF OR M A N CE DA T A CO OL ING O PE RA TION O utdoor Am bi e nt Te m pera ture 65 75 8 5 9 5 105 1 15 E n t eri ng Indo or We t B u lb Temp e rat ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 ...

  • Goodman Mfg GSX - page 33

    33 COOLING PERFORMANCE DA T A GSX130301B*/VSX130301A* M O D E L : G S X 1 303 01B * / C A*F3 030 *6B * EX PAN DE D P ER F O R M ANC E D AT A CO OLING O P E RA TION O utdoor Am bi e nt Te m pera ture 65 75 8 5 9 5 105 1 15 E nt eri ng Indo or We t B ul b Te mp e r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 ...

  • Goodman Mfg GSX - page 34

    34 COOLING PERFORMANCE DA T A GSX130361B*/VSX130361A* MO DEL : G S X 1 303 61 B * / C A*F3 036 *6C * E X P A ND E D P E RF ORMA N CE DA T A COO LIN G O P E RAT IO N Ou tdoor Am bient Te mp e rat ure 65 75 85 9 5 1 05 11 5 E nterin g I nd oor W e t Bul b Tempera ture I D B * A i r f l o w 5 96 36 77 1 5 96 36 77 15 9 6 36 77 15 9 6 3 6 7 7 15 96 36 ...

  • Goodman Mfg GSX - page 35

    35 COOLING PERFORMANCE DA T A GSX130361B*/VSX130361A* MO DE L: G S X 1 303 61B * / C A *F3 036 *6C * EX PA N D E D PER FO R MANC E D ATA COO L IN G O P E RAT IO N Out door A m bie nt Te mpe ra t ure 65 75 85 9 5 1 05 11 5 E nte ri n g I ndoor W e t Bul b Tempe rat u re I D B * A i r f l o w 5 96 36 77 1 5 96 36 77 15 9 6 36 77 15 9 6 3 6 7 7 15 96 ...

  • Goodman Mfg GSX - page 36

    36 COOLING PERFORMANCE DA T A GSX130421B*/VSX130421A* MO DE L : G SX1 304 21B * / C A* F 3 642 * 6C * EX PAN DE D P E R F O R M ANC E D ATA C OOL IN G OP E RA TION Ou t doo r A m bi ent Tempe rat ure 6 5 7 5 85 9 5 10 5 1 15 E nte r ing Ind oor We t Bul b T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 15 ...

  • Goodman Mfg GSX - page 37

    37 COOLING PERFORMANCE DA T A GSX130421B*/VSX130421A* MO DE L : G /VS X 130 4 2 1B* / CA* F3 64 2*6 C* EX PAN DE D P E R F O R M ANC E D AT A C OOL IN G OP E RA T ION Ou t doo r A m bi ent Tempe rat ure 6 5 7 5 85 9 5 10 5 1 15 E nte r ing Ind oor We t Bul b T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 ...

  • Goodman Mfg GSX - page 38

    38 COOLING PERFORMANCE DA T A GSX130481B*/VSX130481A* M O D E L : G S X 1 304 81B * / C A*F 4 860 *6B * EX PAN DE D P ER FO R M AN C E D ATA CO OL ING O PERATION Out door Am bi e nt Te mpe ra t ure 65 75 8 5 9 5 105 1 15 E nt eri ng I ndo o r We t B ulb Te mp e rat u re I D B * A i r f l o w 5 96 36 77 15 9 6 3 6 77 15 96 3 6 7 7 15 9 6 3 6 7 7 15 ...

  • Goodman Mfg GSX - page 39

    39 COOLING PERFORMANCE DA T A GSX130481B*/VSX130481A* M O D E L : G S X13 0 48 1 B* / CA * F 48 6 0* 6 B* EX PAN DE D P ER FO R M AN C E D ATA C O OL ING O P E RATION O utdoor Am bient Tempera ture 65 75 8 5 9 5 105 1 15 E nt eri ng I ndo or We t B ul b Temp e rat ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 3 ...

  • Goodman Mfg GSX - page 40

    40 COOLING PERFORMANCE DA T A GSX130601B*/VSX130601B* M O DE L : G S X 1 306 01B * / C A *F4 961 *6 A* EX PAN DE D P ER F O R M AN C E D ATA C O OL ING O P E RA TION Out door Am bie nt Te mpe ra tu re 65 75 8 5 9 5 105 1 15 E n t e ri ng I ndo or We t B ul b Temp e r at ur e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 1 ...

  • Goodman Mfg GSX - page 41

    41 COOLING PERFORMANCE DA T A GSX130601B*/VSX130601B* M O DE L : G SX 1 30 6 01B * / C A*F 4 961 *6 A* EX PAN DE D P ER FO R M ANC E D A TA CO OL ING O P E RA TION Out door Am bie nt Te mpe ra tu re 65 75 8 5 9 5 105 1 15 E n t e ri ng I ndo or We t B ul b Temp e rat ure I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 3 6 77 15 9 6 3 6 77 15 96 ...

  • Goodman Mfg GSX - page 42

    42 COOLING PERFORMANCE DA T A GSX130363A* MODE L: GSX130 363 A* / C A * F3636 * 6C* E XPANDE D PERF ORM AN CE DATA C OOLIN G OP E R ATION O u td oo r Am bie n t Te m p e r atur e 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m per ature I D B * A i r f l o w 5 96 36 7 7 15 96 36 77 1 5 96 36 77 15 9 6 36 77 15 96 36 77 15 96 36 77 1 M Bh ...

  • Goodman Mfg GSX - page 43

    43 COOLING PERFORMANCE DA T A GSX130363A* MO D E L: G S X 13 036 3 A * / C A * F36 36* 6 C * EXP AND ED PERFO RMA NC E DA TA COO L ING O PERATION Ou td oo r A mb i e n t Te m p er a tu r e 6 5 7 5 85 95 10 5 1 15 Ente r i ng I ndo or We t Bu l b Te mpe rat ur e I D B * A i r f l o w 5 96 36 77 1 5 9 6 36 77 15 9 6 3 6 77 15 96 3 6 7 7 15 96 36 7 7 ...

  • Goodman Mfg GSX - page 44

    44 COOLING PERFORMANCE DA T A GSX130483A* MO D EL: G SX130483A* / C A *F4860* 6B* EX PANDED PERFORM ANCE DAT A C OOL I N G OP E R ATIO N O utd oor Am bien t Te m pe r ature 65 75 85 95 105 115 E nte r i ng I ndoor W e t B ul b Te m pe r at ure I D B * A i r f l o w 5 96 36 77 1 5 96 36 77 15 9 6 3 6 77 15 96 36 77 15 9 6 36 77 15 96 3 6 7 7 1 M Bh ...

  • Goodman Mfg GSX - page 45

    45 COOLING PERFORMANCE DA T A GSX130483A* MO DE L: G S X13 048 3A * / C A * F 48 6 0* 6 B* EX P AND E D PERF O RMA NC E DA T A COOLIN G OPER ATION Out door Ambi ent T emper at ur e 6 5 7 5 85 95 10 5 1 15 Ente r i ng I ndoor We t Bu lb Tempe r at ur e I D B * A i r f l o w 5 96 36 77 1 5 9 6 36 77 15 9 6 3 6 77 15 96 3 6 7 7 15 96 36 7 7 1 5 96 36 ...

  • Goodman Mfg GSX - page 46

    46 COOLING PERFORMANCE DA T A GSX130484A* MO D EL: GSX 130484 A * / C A* F4860* 6B* EX PA NDED PERFOR M ANCE DA TA C O O L IN G O P E R A T IO N O utdo or Am bi e nt Te m pe r ature 65 75 85 95 10 5 115 E nte r ing I n do or We t B ulb Te m pe r ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 1 M B ...

  • Goodman Mfg GSX - page 47

    47 COOLING PERFORMANCE DA T A GSX130484A* M ODEL: G SX 1 3 04 8 4 A* / CA*F 4 8 60 *6 B* EXP AND ED PE RF O RMA NC E DA T A COO L ING OPERAT ION O ut door Ambi ent T empe r at ur e 6 5 7 5 85 95 10 5 1 15 Ente r i ng I ndoor We t Bu lb Te m pe r at ur e I D B * A i r f l o w 5 96 36 77 1 5 9 6 36 77 15 9 6 3 6 77 15 96 3 6 7 7 15 96 36 7 7 1 5 96 3 ...

  • Goodman Mfg GSX - page 48

    48 COOLING PERFORMANCE DA T A GSX130603A* MO D E L: GSX130603 A * / C A * F4961* 6A * E XP ANDED P ERF ORM ANCE D ATA C OO L IN G O P E R AT IO N O utdoo r Am bie nt Te m pe rature 65 75 85 95 105 115 E nte r ing I n doo r Wet B ulb Tem pe r ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 36 77 15 96 36 7 7 15 96 36 7 7 15 9 6 36 77 1 M B ...

  • Goodman Mfg GSX - page 49

    49 COOLING PERFORMANCE DA T A GSX130603A* M ODEL: GSX 1 3 06 0 3 A* / CA*F4 9 61 *6 A* EX P AND E D P ERF O RM A NC E DA T A COO L ING OPERAT I ON Out door Ambi ent T e mpe r at ure 6 5 7 5 85 95 10 5 1 15 Ente ri ng I ndo or We t Bu lb Tem pe r at ure I D B * A i r f l o w 5 96 3 6 77 1 5 9 6 36 77 1 5 9 6 3 6 77 15 96 3 6 7 7 15 96 36 7 7 1 5 96 ...

  • Goodman Mfg GSX - page 50

    50 COOLING PERFORMANCE DA T A GSX130604A* MO D E L : GSX 130604 A * / C A *F4961* 6A * EXPAND ED PERFOR M AN CE DATA C OOL IN G OP E R AT ION O utdoor Am bi e nt Te m pe r ature 65 75 85 95 1 05 115 E nte r ing I ndoor We t B ulb Te m pe r ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 15 96 36 77 1 M Bh 50 . ...

  • Goodman Mfg GSX - page 51

    51 COOLING PERFORMANCE DA T A GSX130604A* M ODEL: GSX1 306 0 4 A* / CA*F4 961 *6 A* EXP A NDED PER F ORMA NC E D A T A CO O L ING OPERATI ON Out door Ambi ent T empe r at ur e 6 5 7 5 85 95 10 5 1 15 Ente ri ng I ndoor Wet Bu l b Te mpe r at ur e I D B * A i r f l o w 5 96 36 77 1 5 9 6 36 77 15 9 6 3 6 77 15 96 3 6 7 7 15 96 36 7 7 1 5 96 36 77 1 ...

  • Goodman Mfg GSX - page 52

    52 PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a ...

  • Goodman Mfg GSX - page 53

    WIRING DIAGRAMS 53 HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT . F A ILURE TO DO SO MA Y CAUS E PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GSX130[18-60]1 ...

  • Goodman Mfg GSX - page 54

    HI GH V OL T AG E! DISC ONNECT ALL POWE R BEFORE SERVICI NG O R INS T A LLIN G THIS UNIT . MU L T IPL E POW ER SOURCES M A Y BE PRESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH . WIRING DIAGRAMS 54 GSX130[18-60]1B*/GSX130181C* VSX130[18-60]1A* US E N.E. C. CL ASS 2 W IRE NOT ES: 1) TO INDO OR UNIT LO W VOLTAGE TE ...

  • Goodman Mfg GSX - page 55

    WIRING DIAGRAMS 55 HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT . F A ILURE TO DO SO MA Y CAUS E PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH. VSX130181B* 01 40R 0 0165 -A OT --------------O UTDOOR TH ERMOST A T Wiring is subject to change, always refer to the wiri ...

  • Goodman Mfg GSX - page 56

    HI GH V OL T AG E! DISC ONNECT ALL POWE R BEFORE SERVICI NG O R INS T A LLIN G THIS UNIT . MU L T IPL E POW ER SOURCES M A Y BE PRESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH . WIRING DIAGRAMS 56 Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GSX130[3 ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg GSX can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GSX manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GSX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GSX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GSX, service manual, brief instructions and user manuals Goodman Mfg GSX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GSX.

A complete manual for the device Goodman Mfg GSX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GSX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GSX.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GSX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GSX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GSX, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GSX - which should help us in our first steps of using Goodman Mfg GSX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GSX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GSX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GSX?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GSX, ask a question using the form below. If a user had a similar problem with Goodman Mfg GSX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)