  • National Instruments AT - page 1

    Serial Serial Hardware and Software for Windows User Manual PCI, PXI , PCMCIA, and AT Serial Hardware Serial Hardware and Software for Windows ™ December 2000 Edition Part Number 322983 A-01 ...

  • National Instruments AT - page 2

    Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 23 ...

  • National Instruments AT - page 3

    Important Information Warranty The serial hardware is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will , at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty ...

  • National Instruments AT - page 4

    Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communication s Commission (FCC) has rules to protect wireless comm unications from interference. The FCC places digital electronics into two classes. These classes ar e known as Class A (for use in industrial- commercial locations only) or Class B (for ...

  • National Instruments AT - page 5

    • Connect the equipment into an outlet on a circuit diffe rent from that to which the rec eiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Canadian Depart ment of Communicati ons This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil ...

  • National Instruments AT - page 6

    © National Instruments Corporation vii Serial Hardware and Software for Windows Contents About This Manual Conventions ............ ........... .............. ............ ........... .............. ........... ............ .............. .... x iii Related Documentation ............... ........... .............. ........... .............. ....... ...

  • National Instruments AT - page 7

    Contents Serial Hardware and Software for Windows viii ni.com Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Windows 2000 ...... ............ ........... ........... ........... .............. ............ ........... ........... ............ 3-1 Install the Software ..................... ........... .............. .... ...

  • National Instruments AT - page 8

    Contents © National Instruments Corporation ix Serial Hardware and Software for Windows Chapter 5 AT Serial Hardware Installation, Verification, and Configuration Windows 2000 ........ .............. ........... ............ ........... .............. ........... ............ ........... ....... 5-1 Install the Software .... .............. ....... ...

  • National Instruments AT - page 9

    Contents Serial Hardware and Software for Windows x ni.com Appendix D Troubleshooting and Common Questions Appendix E Specifications Appendix F Technical Support Resources Glossary Index Figures Figure 2-1. PCI Serial Board Installation .......... ......................... ............... .............. 2-3 Figure 2-2. Device Manager for PCI Serial ...

  • National Instruments AT - page 10

    Contents © National Instruments Corporation xi Serial Hardware and Software for Windows Figure 4-3. Port Settings Tab ........ .............. .......................... ......................... .......... 4-6 Figure 4-4. Advanced Settings Dialog Box ......... ......................... .............. ............. 4-7 Figure 4-5. Inserting a PCMCI ...

  • National Instruments AT - page 11

    Contents Serial Hardware and Software for Windows xii ni.com Figure C-4. Selecting an Interface to Uninstall ...................... .............. .............. ...... C-7 Figure C-5. Selecting an Interface to Uninstall ...................... .............. .............. ...... C-9 Figure C-6. Selecting an Interface to Uninstall ................. ...

  • National Instruments AT - page 12

    © National Instruments Corporation xiii Serial Hardware and Software for Windows About This Manual This manual contains instructions to hel p you install and configure the National Instruments serial hardware and the NI-Serial software for W indows 2000/NT/Me/9 x . This manu al includes informa tion about the follo wing serial hardware: • PCI-23 ...

  • National Instruments AT - page 13

    About This Man ual Serial Hardware and Software for Windows xiv ni.com bold Bold text denotes items that you must select or click on in the software, such as menu items and dialog box options. Bo ld text also denotes parameter names. DTR Signal names with an ov erscore, such as DTR , indicate that the signal is acti ve lo w . italic Italic text den ...

  • National Instruments AT - page 14

    About This Manual © National Instruments Corporation xv Serial Hardware and Software for Windows • NS16550AF Universal Asynchronou s Receiver/Transmitter with FIFOs , National Semiconductor • ST16C654 Asynchronous Receiver/Transmitter with FIFOs , EXAR Corporation ...

  • National Instruments AT - page 15

    © National Instruments Corporatio n 1-1 Serial Hardware and Software for Windows 1 Introduction This chapter explains ho w to use this manual, lists what you need to get started and optional equipmen t you can order , and briefly describes the serial hardware and the NI-Seri al software. How to Use This Manual Ye s No Chapters 2, 3, 4, and 5 Write ...

  • National Instruments AT - page 16

    Chapter 1 Introduction Serial Hardware and Software for Windows 1-2 ni.com What Y ou Need to Get Started Before you install your serial hard ware and the NI-Serial software, mak e sure you have all of the following items: ❑ W indows 2000/NT/Me/9 x installed on your co mputer ❑ One of the fol lowing serial boards, which is included i n your kit: ...

  • National Instruments AT - page 17

    Chapter 1 Introduction © National Instruments Corporatio n 1-3 Serial Hardware and Software for Windows Optional Equipment For more information about ordering the followin g optional equipment, contact National Instruments: • DB-9 RS-485 termination connector (PCI-485 , PCMCIA-485, PXI-8421, PXI-8423, and A T -485 onl y) • 10-position mod ular ...

  • National Instruments AT - page 18

    Chapter 1 Introduction Serial Hardware and Software for Windows 1-4 ni.com The isolated PCI-232 and PCI-485 boards are designed for applications in harsh en vironments. Isolated ports provide reliable communication in situations in volving ground lo ops from different ground lev els or h igh common mode vo ltage induced on the lines in noisy en vir ...

  • National Instruments AT - page 19

    Chapter 1 Introduction © National Instruments Corporatio n 1-5 Serial Hardware and Software for Windows The isolated PXI boards are designed for applicati ons in harsh en vironments. Isolated ports provide reliable communi cation in situations in volving ground loops from different ground le vels or high common mode voltage induced on the lines in ...

  • National Instruments AT - page 20

    Chapter 1 Introduction Serial Hardware and Software for Windows 1-6 ni.com PCMCIA Kits The serial hardware gives you a variety of solutions for serial communications. The PCMCIA-232 interfaces work with the RS-232 protocols, and the PCMCIA-485 interfaces work with the RS-422 and RS-485 protocols. You can use the PCMCIA-232 hardware for serial commu ...

  • National Instruments AT - page 21

    Chapter 1 Introduction © National Instruments Corporatio n 1-7 Serial Hardware and Software for Windows Additionally , the A T serial boards a re av ailable in a t wo-port version (A T-232/2 an d A T -485/2) or a four-port version (A T -232/4 and A T-485/4). The two-port versions use DB-9 connectors. The four-port v ersions use 10-position modular ...

  • National Instruments AT - page 22

    Chapter 1 Introduction Serial Hardware and Software for Windows 1-8 ni.com NI-Serial Software Over view The NI-Serial software for Windows 2 000/NT/Me/9 x includes a native Windows 2000/M e/9 x device driver and Windows NT kernel dri ver that provide full interrupt-driven, buffered I/O for multiple COM ports. You can obtain a maximum baud rate of e ...

  • National Instruments AT - page 23

    Chapter 1 Introduction © National Instruments Corporatio n 1-9 Serial Hardware and Software for Windows Measurement Studio bundles LabW indows/CVI for C programmers, ComponentW orks for Microsoft V isual C++ programmers, and ComponentW orks++ for Microsoft V isual C++ programmers. Measurement Studio is designed for building meas urement and automa ...

  • National Instruments AT - page 24

    © National Instruments Corporatio n 2-1 Serial Hardware and Software for Windows 2 PCI Serial Hardware Installation, V erification, and Configuration This chapter describes ho w to install the NI-Serial software and PCI serial hardware and ho w t o verify the installation. It also describes how to configure the communication port settings. T o beg ...

  • National Instruments AT - page 25

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 2-2 ni.com 9. W indows 2000 should automatically d etect your hardware and display the Found Ne w Hardware W izard. Complete the wizard by clicking Next in each windo w and then Finish . When you complete the wizard, continue to the ...

  • National Instruments AT - page 26

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 2-3 Serial Hardware and Software for Windows Figure 2-1. PCI Serial Board Installatio n 7. Scre w th e PCI serial board mounting bracket to the back panel mounting rail of t he computer . 8. Replace the cover . 9. T urn on your computer ...

  • National Instruments AT - page 27

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 2-4 ni.com V erify the Installation To verify the hardw are and software inst allation, complete th e following steps: 1. Select Start » Settings » Control Panel and double-clic k on the System icon. 2. Click on the Hardware t a ba ...

  • National Instruments AT - page 28

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 2-5 Serial Hardware and Software for Windows 5. V erify the hardware resources, as follows: a. In the Device Manager under Multi-function adapters, double-click on a serial board. b . C l i c ko nt h e Resources tab . If the resources we ...

  • National Instruments AT - page 29

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 2-6 ni.com 4. Double-click on the port you want to configure and refer to the following instructions: • T o view the hardw are resources assigned to the serial port, click on the Resources tab . • T o view or change the port sett ...

  • National Instruments AT - page 30

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 2-7 Serial Hardware and Software for Windows Figure 2-3. Port Settings T ab ...

  • National Instruments AT - page 31

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 2-8 ni.com Advanced Settings To view or change the advanced settin gs, click on the Advanced button. Figure 2-4 shows t he Advanced Sett ings dialog box. Figure 2-4. Advanced Settings Dialog Box The following sections describe the ad ...

  • National Instruments AT - page 32

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 2-9 Serial Hardware and Software for Windows Use FIFO Buffers FIFO buffers are present on the 16550-compatible UA RTs — one for the transmitter and one for the receiver. The Receive Buffer control sets the number of characters received ...

  • National Instruments AT - page 33

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-10 ni.com 8. If your hardware is already installed, restart W indows Me/9 x . 9. W indows Me/9 x should automatically detect your hardware and display one or more N ew Hardware F ound dialo g boxes. Y our operating sys tem (W ind ...

  • National Instruments AT - page 34

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-11 Serial Hardware and Software for Windows Figure 2-5. PCI Serial Board Installatio n 7. Scre w th e PCI serial board mounting bracket to the back panel mounting rail of t he computer . 8. Replace the cover . 9. T urn on your computer ...

  • National Instruments AT - page 35

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-12 ni.com V erify the Installation Before you verify the in stallation, keep in mind that the serial p orts built into your comput er are typically named from C OM1 to COM4. Windows Me/9 x typically issues port names to the ports ...

  • National Instruments AT - page 36

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-13 Serial Hardware and Software for Windows Figure 2-6 shows the De v ice Manager tab for serial hardware that is installed properly . Figure 2-6. Device Manager T ab f or PCI Serial Board Ports 5. V erify the hardware resources, as fol ...

  • National Instruments AT - page 37

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-14 ni.com 6. (Optional) T o determine which physical port is associated with COM x , complete the fo llo wing steps: a. In the Device Manager t ab, under Ports (COM & LPT) , double-click on the serial port (COM x ). b. C l i ...

  • National Instruments AT - page 38

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-15 Serial Hardware and Software for Windows 4. Double-click on the port you want to configure and refer to the following instructions: • T o view the hardw are resources assigned to the serial port, click on the Resources tab . • T ...

  • National Instruments AT - page 39

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-16 ni.com Port Settings T ab In the Port Settings tab, you can change any of the settings by clicking on the arrow button to the right o f a field. When you click on the arrow button, a list of valid values for that field appears ...

  • National Instruments AT - page 40

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-17 Serial Hardware and Software for Windows Advanced Port Settings To view or change the advanced port settings, cli ck on the Advanced button. Figure 2-8 shows t he Advanced Port Settings dialog box. Figure 2-8. Advanced Port Settings ...

  • National Instruments AT - page 41

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-18 ni.com Restore Defaul ts To reset the fields to their default values at any time, click on the Restore Defaults button. Windows NT Install the Software Before you install your serial hard ware, complete the followin g steps to ...

  • National Instruments AT - page 42

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-19 Serial Hardware and Software for Windows Caution Before you remove your board from the package, touch the antistatic plastic package to a metal part of your system chassis to discharge electrostatic ener gy , which can damage sev era ...

  • National Instruments AT - page 43

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-20 ni.com 7. Scre w th e PCI serial board mounting bracket to the back panel mounting rail of t he computer . 8. Replace the cover . 9. T urn on your computer and start Wi ndows NT . The ha r dware i nstal l a t ion is c o mp l e ...

  • National Instruments AT - page 44

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-21 Serial Hardware and Software for Windows Configure Communication Port Settings The serial configuration utility is fully integrated into the Windows NT Control Panel. You can use it to view or change the configurat ion of your serial ...

  • National Instruments AT - page 45

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 2-22 ni.com General Port Settings The following sections describe th e options you can set in the General Port Settings dialog box, shown in Figure 2-11. Figure 2-11. General Port Settings Dialog Box COM Port Number You can use the ...

  • National Instruments AT - page 46

    Chapter 2 PCI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 2-23 Serial Hardware and Software for Windows FIFO Buffer Size The Receive FIFO size control sets the number of characters received in the FIFO before the PC i s interrupted to read the d ata. The Transmit FIFO size control set s the maxi ...

  • National Instruments AT - page 47

    © National Instruments Corporatio n 3-1 Serial Hardware and Software for Windows 3 PXI Serial Hardware Installation, V erification, and Configuration This chapter describes how to install the NI-Serial software and PXI serial hardware and ho w to verify the installation. It also describes how to view or change the communicati on port settings. T o ...

  • National Instruments AT - page 48

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 3-2 ni.com 9. W indows 2000 should automatically d etect your hardware and display the Found Ne w Hardware W izard. Complete the wizard by clicking Next in each windo w and then Finish . When you complete the wizard, continue to the ...

  • National Instruments AT - page 49

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 3-3 Serial Hardware and Software for Windows Figure 3-1. Installing the PXI Serial Board 6. Scre w the PXI serial board front panel to the front panel m ounting rail of the PXI or CompactPCI chassis. 7. T urn on your PXI or Com pactPCI c ...

  • National Instruments AT - page 50

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 3-4 ni.com V erify the Installation To verify the hardw are and software inst allation, complete th e following steps: 1. Select Start » Settings » Control Panel and double-clic k on the System icon. 2. Click on the Hardware t a ba ...

  • National Instruments AT - page 51

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 3-5 Serial Hardware and Software for Windows 5. V erify the hardware resources, as follows: a. In the Device Manager under Multi-function adapters, double-click on a serial board. b . C l i c ko nt h e Resources tab . If the resources we ...

  • National Instruments AT - page 52

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 3-6 ni.com 4. Double-click on the port you want to configure and refer to the following instructions: • T o view the hardw are resources assigned to the serial port, click on the Resources tab . • T o view or change the port sett ...

  • National Instruments AT - page 53

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 3-7 Serial Hardware and Software for Windows Figure 3-3. Port Settings T ab Advanced Settings To view or change the advanced settings, click on the Advanced button. Figure 3-4 shows t he Advanced Sett ings dialog box. ...

  • National Instruments AT - page 54

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 3-8 ni.com Figure 3-4. Advanced Settings Dialog Box The following sections describe the adv anced settings options. T ransceiver Mode This field shows the transceiver mode in use, and applies only t o RS-485 boards. For more informat ...

  • National Instruments AT - page 55

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 3-9 Serial Hardware and Software for Windows Restore Default s To reset the fields to their default values at any time, click on the Restore Defaults button. Windows Me/9 x Install the Software Before you install your serial hard ware, c ...

  • National Instruments AT - page 56

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-10 ni.com Install the Hardware Caution Before you remove your board from the package, touch the antistatic plastic package to a metal part of your system chassis to discharge electrostatic ener gy , which can damage sev eral co m ...

  • National Instruments AT - page 57

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-11 Serial Hardware and Software for Windows 6. Scre w the PXI serial board front panel to the front panel m ounting rail of the PXI or CompactPCI chassis. 7. T urn on your PXI or Com pactPCI chassis and start W in dows Me/9 x . 8. W ind ...

  • National Instruments AT - page 58

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-12 ni.com Figure 3-6 shows the De v ice Manager tab for serial hard ware that is installed properly . Figure 3-6. Device Manager for PXI Serial Board Ports 5. V erify the hardware resources, as follows: a. In the Device Manager t ...

  • National Instruments AT - page 59

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-13 Serial Hardware and Software for Windows 6. (Optional) T o determine which physical port is associated with COM x , complete the fo llo wing steps: a. In the Device Manager tab, under Ports (COM & LPT) , double-click on the seria ...

  • National Instruments AT - page 60

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-14 ni.com 4. Double-click on the port you want to configure and refer to the following instructions: • T o view the hardw are resources assigned to the serial port, click on the Resources tab . • T o view or change the port s ...

  • National Instruments AT - page 61

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-15 Serial Hardware and Software for Windows Port Settings T ab In the Port Settings tab, you can change any of the settings by clicking on the arrow button to the right o f a field. When you click on the arrow button, a list of valid va ...

  • National Instruments AT - page 62

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-16 ni.com Advanced Port Settings To view or change the advanced port settings, cli ck on the Advanced button. Figure 3-8 shows t he Advanced Port Settings dialog box. Figure 3-8. Advanced Settings Dialog Box The following section ...

  • National Instruments AT - page 63

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-17 Serial Hardware and Software for Windows Restore Default s To reset the fields to their default values at any time, click on the Restore Defaults button. Windows NT Install the Software Before you install your serial hard ware, compl ...

  • National Instruments AT - page 64

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-18 ni.com T o install your PXI serial board, complete the following steps: 1. T urn off your PXI or CompactPCI chassis. K eep the PXI or CompactPCI chassis plugged in so that i t remains grounded while you install the PXI seri al ...

  • National Instruments AT - page 65

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-19 Serial Hardware and Software for Windows 6. Scre w the PXI serial board front panel to the front panel m ounting rail of the PXI or CompactPCI chassis. 7. T urn on your PXI or Com pactPCI chassis and start W in dows NT . The serial h ...

  • National Instruments AT - page 66

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-20 ni.com Configure Communication Port Settings The serial configuration utility is fully integrated into the Windows NT Control Panel. You can use it to view or change the configurat ion of your serial ports. T o configure a ser ...

  • National Instruments AT - page 67

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 3-21 Serial Hardware and Software for Windows General Port Settings The following sections describe th e options you can set in the General Port Settings dialog box, shown in Figure 3-11. Figure 3-11. General Port Settings Dialog Box COM ...

  • National Instruments AT - page 68

    Chapter 3 PXI Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 3-22 ni.com FIFO Buffer Size The Receive FIFO size control sets the number of characters received in the FIFO before the PC i s interrupted to read the d ata. The Transmit FIFO size control set s the maximum number of b ytes writt ...

  • National Instruments AT - page 69

    © National Instruments Corporatio n 4-1 Serial Hardware and Software for Windows 4 PCMCIA Serial Hardware Installation, V erification, and Configuration This chapter describes how to install the NI-Serial software and PCMCIA serial hardware and how to v erify the installati on. It also describes how to view or change the communication port setting ...

  • National Instruments AT - page 70

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 4-2 ni.com 8. W indows 2000 should automatically d etect your hardware and display the Found Ne w Hardware W izard. Complete the wizard by clicking Next in each windo w and then Finish . When you complete the wizard, continue to t ...

  • National Instruments AT - page 71

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 4-3 Serial Hardware and Software for Windows Figure 4-1 shows ho w to insert a PCMCIA serial card and ho w to connect the cable. Figure 4-1. Inserting a PCMCIA Serial Card The serial hardware installation is co mplete. Continue to the ...

  • National Instruments AT - page 72

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 4-4 ni.com Figure 4-2 shows the De v ice Manager tab for serial hard ware that is installed properly . Figure 4-2. Device Manager for PCMCIA Serial Card Ports 5. V erify the hardware resources, as follows: a. In the Device Manager ...

  • National Instruments AT - page 73

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 4-5 Serial Hardware and Software for Windows 7. Run the diagnostic utility , as follows: s elect Start » Programs » National Instruments » NI-Serial » Diagnostics . The diagnostic utility verifies that your serial driv er is insta ...

  • National Instruments AT - page 74

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 4-6 ni.com Port Settings T ab In the Port Settings tab, you can change any of the settings by clicking on the arrow button to the right o f a field. When you click on the arrow button, a list of valid values for that field appears ...

  • National Instruments AT - page 75

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 4-7 Serial Hardware and Software for Windows Advanced Settings To view or change the advanced settings, click on the Advanced button. Figure 4-4 shows t he Advanced Sett ings dialog box. Figure 4-4. Advanced Settings Dialog Box The fo ...

  • National Instruments AT - page 76

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 4-8 ni.com Use FIFO Buffers FIFO buffers are present on the 16550-compatible UA RTs — one for the transmitter and one for the receiver. The Receive Buffer control sets the number of characters received in the FIFO before the PC ...

  • National Instruments AT - page 77

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 4-9 Serial Hardware and Software for Windows 5. If you need to install your hardware, or if this is your first time to install the NI-Serial software fo r W indows Me/9 x , skip to the next section, I n s t all t he Hardw a r e . Othe ...

  • National Instruments AT - page 78

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-10 ni.com Figure 4-5 shows ho w to insert a PCMCIA serial card and ho w to connect the cable. Figure 4-5. Inserting a PCMCIA Serial Card The serial hardware installation is c omplete. Continue to the next section, Ver i fy the ...

  • National Instruments AT - page 79

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-11 Serial Hardware and Software for Windows The two-port and four-port PCMCIA cards are configured as de vices belonging to the “ multi- function adap ters ” class. The mu lti-function parent de v ice is listed under the Multi-fu ...

  • National Instruments AT - page 80

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-12 ni.com V erify the Hardware Resources For every port of the newly installed serial interface, double-click on the name of the serial port in the Device Manager. Then, click on the Resources tab. If the resources were assign ...

  • National Instruments AT - page 81

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-13 Serial Hardware and Software for Windows After you verify the hardware and software installation, connect the cables. See Appendix A, Connector Descriptions , for information about cable connections. Configure Communication Port S ...

  • National Instruments AT - page 82

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-14 ni.com Port Settings T ab On the Port Settings tab, you can change any of t he settings by clicki ng on the arrow button to the right of the setti ng. When you click on the arrow button, a list of valid values for t hat set ...

  • National Instruments AT - page 83

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-15 Serial Hardware and Software for Windows Advanced Port Settings You can view or change the advanced port setting s by clicking on the Advanced b u t t o no nt h e Port Settings tab. Figu re 4-8 shows the Advanced Port Settings dia ...

  • National Instruments AT - page 84

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-16 ni.com Note If you want your serial hardware p orts to use the names COM1, CO M2, COM3, or COM4, refer to the Common Questio ns section of Appendix D, Troubleshootin g and Common Questions . Restore Defaul ts To reset the f ...

  • National Instruments AT - page 85

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-17 Serial Hardware and Software for Windows Install the PCMCIA Serial Hardware Complete the following steps to install the PCMCIA-232 or PCMCIA-485 in your computer: 1. Shut down the computer . 2. Insert the card into a free PC Card ...

  • National Instruments AT - page 86

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-18 ni.com Select Resources for the PCMCIA Card Complete the following steps to select resources for your PCMCIA card. 1. Select Start » Settings » Control Panel . 2. Double-click on t he nipo rts icon. 3. Select the PCMCIA c ...

  • National Instruments AT - page 87

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-19 Serial Hardware and Software for Windows If the diagnostic test com pletes with no failures, your serial hardware and software are installed properly . If it fails, refer to Appendix D, Troubleshooting and Comm on Questions , for ...

  • National Instruments AT - page 88

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-20 ni.com 5. Click on Delete to remov e hardware information abou t the port from W indows NT . Y ou should do this before yo u physically remov e your PCMCIA card. 6. Click on Add to configure resources for a new PCMCIA card. ...

  • National Instruments AT - page 89

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-21 Serial Hardware and Software for Windows FIFO Enabled You can use the FIF O Enabled control to enable or disable the F IFO buffers on the serial port. FIFO buffers are present on the 16550-compatible UARTs — one for the transmit ...

  • National Instruments AT - page 90

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 4-22 ni.com Resource Settings The following sections explain the resource configuration options for each serial interface. PCMCIA-232, PCMCIA-485, PCMCIA-232/4 Figure 4-12 shows the resource configu ration dialog box for a PCMCI ...

  • National Instruments AT - page 91

    Chapter 4 PCMCIA Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 4-23 Serial Hardware and Software for Windows PCMCIA-232/2, PCMCIA-485/2 These cards require two base I/O settings, one for each port, and they share an IRQ. Figure 4-13 sh o ws the resource configuration dialog box for a PCMCIA-485/2. ...

  • National Instruments AT - page 92

    © National Instruments Corporatio n 5-1 Serial Hardware and Software for Windows 5 A T Serial Hardware Installation, V erification, and Configuration This chapter describes how to install the NI-Serial software and A T serial hardware and ho w to verify the installation. It also describes how to view or change the communicati on port settings. T o ...

  • National Instruments AT - page 93

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 5-2 ni.com 9. W indows 2000 should automatically d etect your hardware and display the Found Ne w Hardware W izard. Complete the wizard by clicking Next in each windo w and then Finish . When you complete the wizard, continue to the ...

  • National Instruments AT - page 94

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 5-3 Serial Hardware and Software for Windows Figure 5-1. A T Serial Board Inst allation 7. Scre w th e A T serial board mounting bracket to the back panel mounting rail of t he computer . 8. Replace the cover . 9. T urn on your computer ...

  • National Instruments AT - page 95

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 5-4 ni.com V erify the Installation To verify the hardw are and software inst allation, complete th e following steps: 1. Select Start » Settings » Control Panel and double-clic k on the System icon. 2. Click on the Hardware t a ba ...

  • National Instruments AT - page 96

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 5-5 Serial Hardware and Software for Windows 5. V erify the hardware resources, as follows: a. In the Device Manager under Multi-function adapters, double-click on a serial board. b . C l i c ko nt h e Resources tab . If the resources we ...

  • National Instruments AT - page 97

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 5-6 ni.com 4. Double-click on the port you want to configure and refer to the following instructions: • T o view the hardw are resources assigned to the serial port, click on the Resources tab . • T o view or change the port sett ...

  • National Instruments AT - page 98

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 5-7 Serial Hardware and Software for Windows Port Settings T ab In the Port Settings tab, you can change any of the settings by clicking on the arrow button to the right o f a field. When you click on the arrow button, a list of valid va ...

  • National Instruments AT - page 99

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and Software for Windows 5-8 ni.com Advanced Settings To view or change the advanced settin gs, click on the Advanced button. Figure 5-4 shows t he Advanced Sett ings dialog box. Figure 5-4. Advanced Settings Dialog Box The following sections describe the ad ...

  • National Instruments AT - page 100

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporatio n 5-9 Serial Hardware and Software for Windows Use FIFO Buffers FIFO buffers are present on the 16550-compatible UA RTs — one for the transmitter and one for the receiver. The Receive Buffer control sets the number of characters received ...

  • National Instruments AT - page 101

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-10 ni.com 5. If you need to install your hardware, or if this is your first time to install the NI-Serial software fo r W indows Me/9 x , skip to the next section, I n s t all t he Hardw a r e . Otherw i se, c ont i nue to Step 6 ...

  • National Instruments AT - page 102

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-11 Serial Hardware and Software for Windows Figure 5-5. A T Serial Board Inst allation 7. Scre w th e A T serial board mounting bracket to the back panel mounting rail of t he computer . 8. Replace the cover . 9. T urn on your computer ...

  • National Instruments AT - page 103

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-12 ni.com V erify the Installation When you begin to verify the install ation, keep in mind that t he serial ports built into the comput er are typically named from COM1 to CO M4. Windows Me/9 x typically issues port names to the ...

  • National Instruments AT - page 104

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-13 Serial Hardware and Software for Windows Figure 5-6. Device Manager Ports List for A T Serial Board Correctly Installed V erify the Hardware Resources For every port of the newly installed serial interface, double-click on the name o ...

  • National Instruments AT - page 105

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-14 ni.com Determine Which Physical Port Is Associated with COMx For every port of the newly installed serial interface, double-click on the name of the serial port in the Device Mana ger. Then, click on the Port Settings tab. The ...

  • National Instruments AT - page 106

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-15 Serial Hardware and Software for Windows 3. Double-click on t he Ports (COM & LPT) icon. 4. Double-click on the name of the port you want to configure. Y ou can now vie w or chang e information about y our serial port in the foll ...

  • National Instruments AT - page 107

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-16 ni.com Port Settings T ab On the Port Settings tab, you can change any of t he settings by clicki ng on the arrow button to the right of the setti ng. When you click on the arrow button, a list of valid values for t hat settin ...

  • National Instruments AT - page 108

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-17 Serial Hardware and Software for Windows Advanced Port Settings You can view or change the advanced port setting s by clicking on the Advanced b u t t o no nt h e Port Settings tab. Figu re 5-8 shows the Advanced Port Settings dialog ...

  • National Instruments AT - page 109

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-18 ni.com Use FIFO Buffers The FIFO buffer control is available by clicking on th e Advanced button on the Port Settings tab. FIFO buffers are present on th e 16550-compati ble UARTs — one for the transmitter and one for the re ...

  • National Instruments AT - page 110

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-19 Serial Hardware and Software for Windows Install the NI-Serial Software Install the NI-Serial software for Windows NT before you install the hardware. Make sure that you have already installed the PnP ISA Enabler driver as described ...

  • National Instruments AT - page 111

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-20 ni.com Complete the following steps to install your A T serial board: 1. T urn off your computer . K eep the com puter plugged in so t hat it remains grounded while you install the A T serial board. 2. Remov e th e top or side ...

  • National Instruments AT - page 112

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-21 Serial Hardware and Software for Windows 7. W indows NT displays one or mo re New Hardw are Found dialog boxes, depending on your serial hardware. In each dialog box, m ake sure that Windows Default Driver is selected, and click on O ...

  • National Instruments AT - page 113

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-22 ni.com If the diagnostic test completes w ith no failures, your serial hardware and software are installed properly . If it fails, r efer to Appendix D, Troubleshooting and Comm on Questions , for tro ubleshooting instruct ion ...

  • National Instruments AT - page 114

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-23 Serial Hardware and Software for Windows 4 . C l i c ko nt h e Resources button in the General Port S ettings dialog box to view or configure the resources for the port. Refer to the Resource Settings section, later in this chapter, ...

  • National Instruments AT - page 115

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-24 ni.com FIFO Enabled You can use the FIF O Enabled control to enable or disable the FIFO buffers on the serial port. FIFO buffers are present on the 16550-compatible UARTs — one for the transmitter and one for the receiver. F ...

  • National Instruments AT - page 116

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration © National Instruments Corporation 5-25 Serial Hardware and Software for Windows A T Boards (Shared IRQ) Figure 5-12 sh ows the PnP Port Configuration dialog box for an AT-232/4 with shared IRQ. The dialog boxes for other shared IRQ AT boards are similar. Figure 5-12. PnP ...

  • National Instruments AT - page 117

    Chapter 5 A T Serial Hardware Installation, Verification, and Configuration Serial Hardware and S oftware for Window s 5-26 ni.com Note If you are unable to chang e the base I/O address by double-clickin g on the Input/Output Range contro l, select a different Basic Conf iguratio n in the Setting based on: control. A T Boards (Non-Shared IRQ) Each ...

  • National Instruments AT - page 118

    © National Instruments Corporatio n 6-1 Serial Hardware and Software for Windows 6 Using Y our Serial Hardware This chapter describes how to set the hardware transcei ver control mode for your RS-485 interfaces and lis ts some general programming requirements. General Programming Requirements The NI-Serial software is fully integr ated into the st ...

  • National Instruments AT - page 119

    Chapter 6 Using Y our Ser ial Hardware Serial Hardware and Software for Windows 6-2 ni.com Note Signal names with an o verscore, such as DTR , indicate that the signal is acti ve lo w . Four -Wire Mode Use the four-wire mod e for most full-duplex systems. In this mode, the transmitter and receiver are always enabled. This mode is the default. T wo- ...

  • National Instruments AT - page 120

    Chapter 6 Using Y our Serial Har dware © National Instruments Corporatio n 6-3 Serial Hardware and Software for Windows T wo-Wire Mode: TXRDY Auto Control In this mode, the serial hardware transparently enables the transmitter and receiver in a two-wire system. Use this mode to remove the burden o f flow control from your applicati on. By connecti ...

  • National Instruments AT - page 121

    Chapter 6 Using Y our Ser ial Hardware Serial Hardware and Software for Windows 6-4 ni.com The scratch register is located at of fset 7 from the base address of the port. For e xampl e, if COM2 were located at base address 0x3F8, and you want to set the board to two-wire mode with DTR control, you would write a 0x02 to address 0x3FF . The board wou ...

  • National Instruments AT - page 122

    Chapter 6 Using Y our Serial Har dware © National Instruments Corporatio n 6-5 Serial Hardware and Software for Windows For e xample, to set TXRD Y two-wire auto control mode, use t he following code: Windows 2000 ULONG TranceiverMode = 131; ULONG dummy; DeviceIoControl(hDevice, IOCTL_SERIAL_SET_TRANSCEIVER_MODE,(P VOID) &TransceiverMode,sizeo ...

  • National Instruments AT - page 123

    © National Instruments Corporation A-1 Serial Hardware and Software for Windows A Connector Descriptions Connecting Cables For the PCMCIA serial cards and two-port PCI, PXI, and AT serial boards, you can use the standard DB-9 connector found on most serial cables. To use the DB-9 connector with the four-port serial b oards, you need the 10-positio ...

  • National Instruments AT - page 124

    Appendix A Conn ector Descriptions Serial Hardware and Software for Windows A- 2 ni.com For information about setting the transceiv e r mode for two-wire communication, refer to Chapter 6, Using Your Seria l Hardware .F o rm o r e information about duplex architectures, refer to Appendix B, Serial Port Information . DB-9 Connector Figure A-1 and T ...

  • National Instruments AT - page 125

    Appendix A Connector Descriptions © National Instruments Corporation A-3 Serial Hardware and Software for Windows Modular Jack Connector Figure A-2 and T able A-2 gi ve the pin locations and descriptions of the 10-position modular j ack. Figure A-2. 10-Position Modular Jack Pin Locations Table A-2. 10-Position Modular Jack Pin Descriptions 10-Posi ...

  • National Instruments AT - page 126

    Appendix A Conn ector Descriptions Serial Hardware and Software for Windows A- 4 ni.com DB-25 Connector Figure A-3 and T able A-3 gi ve the pin locations and descriptions of the DB-25 connector , which is on the optional 10-position modular jack to DB-25 cable. Figure A-3. DB-25 Connector Pin Locations Table A-3. DB-25 Pin Descriptions DB-25 Pin 23 ...

  • National Instruments AT - page 127

    Appendix A Connector Descriptions © National Instruments Corporation A-5 Serial Hardware and Software for Windows Figure A-4 shows ho w to connect the cab les when you install a four-port PCI serial bo ard. Figure A-4. Connecting the Cables to Y our Four -Port PCI Serial Board Serial Board Additional Serial Cable Additional Serial Cable 10-Positio ...

  • National Instruments AT - page 128

    Appendix A Conn ector Descriptions Serial Hardware and Software for Windows A- 6 ni.com 68-Pin Connector Figure A-5 and T able A-4 gi ve the pin locations and descriptions of the 68-pin connector . Figure A-5. 68-Pin Connector Pin Locations PIN 35 PIN 68 PIN 34 PIN 1 ...

  • National Instruments AT - page 129

    Appendix A Connector Descriptions © National Instruments Corporation A-7 Serial Hardware and Software for Windows Table A-4. 68-Pin Connector Pin Descriptions 68-Pin Connector Port 485 Signal 485 D-Sub 9 Connector 232 Signal 232 D-Sub 9 Connector 12345678 66 57 49 40 32 23 15 6 RXD – 5 DCD 1 68 59 51 42 34 25 17 8 CTS+ 2 RXD 2 65 56 48 39 31 22 ...

  • National Instruments AT - page 130

    Appendix A Conn ector Descriptions Serial Hardware and Software for Windows A- 8 ni.com 100-Pin Connector Figure A-6 and T able A-5 gi ve the pin locations and descriptions of the 100-pin connector . Figure A-6. 100-Pin Connector Pin Locations PIN 50 PIN 100 PIN 1 PIN 51 ...

  • National Instruments AT - page 131

    Appendix A Connector Descriptions © National Instruments Corporation A-9 Serial Hardware and Software for Windows Table A-5. 100-Pin Connector Pin Descriptions 100-Pin Connector Port 232 Signal 232 D-Sub 9 Connector 123456789 10 11 12 13 14 15 16 2 46 6 42 10 38 14 34 — — — — — — — — DCD* 1 3 47 7 43 11 39 15 35 18 32 20 30 22 28 2 ...

  • National Instruments AT - page 132

    © National Instruments Corporation B-1 Serial Hardware and Software for Windows B Serial Port Information This appendix describes the RS-232, RS-422, and RS-485 stan dards and explains some of the issues in volv ed with these types of serial communication. T able A-1 lists the features of the RS-232, RS-422, and RS-485 standard s. RS-232 As specif ...

  • National Instruments AT - page 133

    Appendix B Serial Port Information Serial Hardware and Software for Windows B- 2 ni.com distances of 50 ft and with data rates up to 20 kbytes / s. Howe ver , because of improv ements in line driv ers and cabling, you can usually increase the actual performance of the bus past the limitations on sp eed and distance recommended in the specification. ...

  • National Instruments AT - page 134

    Appendix B Serial Port Information © National Instruments Corporation B-3 Serial Hardware and Software for Windows Serial Communication Issues This section explains some serial communication issues, incl uding duplex architectures, termination methods, bias resistors, and types of connecting equipment. Duplex Architectures Duplex refers to the mea ...

  • National Instruments AT - page 135

    Appendix B Serial Port Information Serial Hardware and Software for Windows B- 4 ni.com Figure B-1. T ypical Full-D uplex Syste m Half Duplex A typical half-duplex multidrop bus architecture also in volves a master-slav e proto col. Howe ver , in a half-duplex system, all transmit ters and recei vers are connected to the same transmission line. A h ...

  • National Instruments AT - page 136

    Appendix B Serial Port Information © National Instruments Corporation B-5 Serial Hardware and Software for Windows T ermination Because each dif ferential pair of wires is a transmission line, you must properly terminate the line to prev ent refl ections. A common method of terminating a two-wire m ultidrop RS- 485 network is to install terminatin ...

  • National Instruments AT - page 137

    Appendix B Serial Port Information Serial Hardware and Software for Windows B- 6 ni.com Figure B-4 sho ws a transmissio n line using b ias resistors. Figure B-4. T ransmission Line Using Bias R esistors On the PCI RS-485 2- and 4-port serial cards, there are four user-conf igurable bias resistors in front of each connector . These resistors are soc ...

  • National Instruments AT - page 138

    Appendix B Serial Port Information © National Instruments Corporation B-7 Serial Hardware and Software for Windows DTE vs. DCE In the RS-232 specif ication, DTE (Data T erminal Equipment) and DCE (Data Commun ications Equip ment) 1 refer to the types of equ ipment on either end of a serial connection. In general, DTE and DCE refer to computer equi ...

  • National Instruments AT - page 139

    © National Instruments Corporatio n C-1 Serial Hardware and Software for Windows C Uninstalling the Hardware and Software This appendix describes how to uninstall your serial hardware and the NI-Serial software. T o begin your uninstallation, see the section of this appendix co ntaining instructions for your hardware platform and operatin g system ...

  • National Instruments AT - page 140

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C -2 ni.co m PCI Hardware Windows 2000 Uninstall the Hardware Before you physically rem ov e t he serial hardware from your system, yo u must remov e th e hardware information. T o do so, complete the following steps: 1. Select Start»Settings»Control Panel ...

  • National Instruments AT - page 141

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-3 Serial Hardware and Software for Windows 5. Choose the Uninstall... option. 6. In the Conf irm Device Remo val dialog box , click on the OK butt o n to remove the hardw are information, or click on t he Cancel button to cancel your request. Uninstall the Sof ...

  • National Instruments AT - page 142

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C -4 ni.co m 4. From the Multi-function adapters list , select the National Instruments interface that you w ant to uninstall, as show n in Figure C-2. Figure C-2. Selecting an Interface to Uninstall 5. Click on the Remov e button. 6. In the Conf irm Device R ...

  • National Instruments AT - page 143

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-5 Serial Hardware and Software for Windows 3. Select the NI-Serial software you want to uninstall, and click on the Add/Remove button. The uninstallation program removes all folders, utilities, and registry entries associated with the NI-Serial software. 4. Sh ...

  • National Instruments AT - page 144

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C -6 ni.co m 4. Click on the Delete button. 5. Repeat steps 3 and 4 until you hav e removed e very PCI serial port that you want to uninstall. Uninstall the Software Before you uninstall the NI-Serial software, you must remov e the hard ware information from ...

  • National Instruments AT - page 145

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-7 Serial Hardware and Software for Windows PXI Hardware Windows 2000 Uninstall the Hardware Before you physically rem ov e t he serial hardware from your system, yo u must remov e th e hardware information. T o do so, complete the following steps: 1. Select St ...

  • National Instruments AT - page 146

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C -8 ni.co m 5. Choose the Uninstall... option. 6. In the Conf irm Device Remo val dialog box , click on the OK butt o n to remove the hardw are information, or click on t he Cancel button to cancel your request. Uninstall the Software Before you uninstall th ...

  • National Instruments AT - page 147

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-9 Serial Hardware and Software for Windows 4. From the Multi-function adapters list , select the National Instruments interface that you w ant to uninstall, as show n in Figure C-5. Figure C-5. Selecting an Interface to Uninstall 5 . C l i c ko nt h e Remove b ...

  • National Instruments AT - page 148

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-10 ni.com 3. Select the NI-Serial software you want to uninstall, and click on the Add/Remove button. The uninstallation program removes all folders, utilities, and registry entries associated with the NI-Serial softw are. 4. Shut down W indo ws Me/9 x , tu ...

  • National Instruments AT - page 149

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-11 Serial Hardwar e and Software for Windows 3 . C l i c ko nt h e Delete button. 4. Repeat steps 3 and 4 until you ha ve remov ed ev ery PXI serial port that you want to uninstall. Uninstall the Software Before you uninstall the NI-Serial software, you must r ...

  • National Instruments AT - page 150

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-12 ni.com PCMCIA Hardware Windows 2000 Uninstall the Hardware Before you physically rem ov e t he serial hardware from your system, yo u must remov e th e hardware information. T o do so, complete the following steps: 1. Select Start»Settings»Control Pane ...

  • National Instruments AT - page 151

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-13 Serial Hardwar e and Software for Windows 5. Choose the Uninstall... option. 6. In the Conf irm Device Remo val dialog box , click on the OK butt o n to remove the hardw are information, or click on t he Cancel button to cancel your request. Uninstall the S ...

  • National Instruments AT - page 152

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-14 ni.com 5. Select the National Instruments p ort to remove from the list of ports, as shown in Figure C-8. Figure C-8. Selecting an Interface to Uninstall 6. Click on the Remov e button. Note To remove ports on two -port and four-port PCM CIA cards from w ...

  • National Instruments AT - page 153

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-15 Serial Hardwar e and Software for Windows Uninstall the Software Before uninstalling the software, remove all serial port information from the W indows Me/9 x Device Manager , as describ ed in the pre vious section. Y ou do not need to shut down W indows Me ...

  • National Instruments AT - page 154

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-16 ni.com Figure C-9. Selecting an Interface to Uninstall 3. Click on the Delete button. Note For tw o-port and four -port PCMCIA cards, all ports on the interface are remo ved. Uninstall the Software Before uninstalling the software, remove all serial port ...

  • National Instruments AT - page 155

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-17 Serial Hardwar e and Software for Windows A T Hardware Windows 2000 Uninstall the Hardware Before you physically rem ov e t he serial hardware from your system, yo u must remov e th e hardware information. T o do so, complete the following steps: 1. Select ...

  • National Instruments AT - page 156

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-18 ni.com 5. Choose the Uninstall... option. 6. In the Conf irm Device Remo val dialog box , click on the OK butt o n to remove the hardw are information, or click on t he Cancel button to cancel your request. Uninstall the Software Before you uninstall the ...

  • National Instruments AT - page 157

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-19 Serial Hardwar e and Software for Windows 5. Select the National Instruments port to rem ov e from the list of ports, as shown in Figure C-11. Figure C-11. Select ing an Inter face to Uninstall 6 . C l i c ko nt h e Remove button. Note T o remov e ports on ...

  • National Instruments AT - page 158

    Appendix C Uninstalling the Hardware and Software Serial Hardware and Software for Windows C-20 ni.com Uninstall the Software Before uninstalling the software, remove all serial port information from the W indows Me/9 x De v ice Manager , as described in the previous section. Y ou do not need to shut down W indows Me/9 x before uninstalling the sof ...

  • National Instruments AT - page 159

    Appendix C Uninstal ling the Hardware and Software © National Instruments Corporatio n C-21 Serial Hardwar e and Software for Windows Figure C-12. Select ing an Inter face to Uninstall 3 . C l i c ko nt h e Delete button. Note For shared IRQ A T boards, all p orts on the interface are removed. Uninstall the Software Before uninstalling the softwar ...

  • National Instruments AT - page 160

    © National Instruments Corporatio n D-1 Serial Hardware and Software for Windows D T roubleshooting and Common Questions This appendix describes how to troubleshoot problems and answers some common questions. T o f ind the information you are loo king for , see the section of this a ppendix for your operating syste m: Windows 2000 Forcing Windows ...

  • National Instruments AT - page 161

    Appendix D T roubleshootin g and Common Questions Serial Hardware and Software for Windows D-2 ni.com Windows 2000 Forcing Windows to Detect Y our Hardware If W indows 2000 did not display the Found Ne w Hardware W izard, it did not detect your hardware. T o solve this problem, complete the following steps: 1. Select Start»Settings»Control Panel ...

  • National Instruments AT - page 162

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporatio n D-3 Serial Hardware and Software for Windows 5. Choose the Uninstall... option. 6. In the Conf irm Device Remo val dialog box , click on the OK butt o n to remove the hardw are information, or click on t he Cancel button to cancel your request. 7 . C l i c ko nt ...

  • National Instruments AT - page 163

    Appendix D T roubleshootin g and Common Questions Serial Hardware and Software for Windows D-4 ni.com Resolving Resource Conflicts with Legacy Boards Resource conflicts typically occur if your system contains legac y boards that use resources that are not reserved properly . If a resource conflict exists, write do wn the reso urce that caused the c ...

  • National Instruments AT - page 164

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporatio n D-5 Serial Hardware and Software for Windows 3. Double-click on t he Ports (COM & LPT) icon. 4. Double-click on the port you want to configure. 5 . C l i c ko nt h e Port Settings tab . 6 . C l i c ko nt h e Advanced button. The Advanced Settings dialog box s ...

  • National Instruments AT - page 165

    Appendix D T roubleshootin g and Common Questions Serial Hardware and Software for Windows D-6 ni.com Windows Me/9 x Freeing an Interrupt Request Level T o free an interrupt request le vel for your serial port, you must disable the de v ice that is using the interr upt request lev el. T o v ie w the system-wide allocation of interrupt request resou ...

  • National Instruments AT - page 166

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporatio n D-7 Serial Hardware and Software for Windows Selecting Conflict-Free Resources PCI and PXI Boards When the De vice Manager indicates a conflict with another de vice, you can usually correct the problem by manually selecting conflict-free resources. T o do so, com ...

  • National Instruments AT - page 167

    Appendix D T roubleshootin g and Common Questions Serial Hardware and Software for Windows D-8 ni.com 6. Uncheck the Use automatic settings checkbox and click on the Change Setting button. If the system does not allo w you to ch ange the settings, select the co nfiguration that giv e s you a confl ict-free base address and interrupt lev el from the ...

  • National Instruments AT - page 168

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporatio n D-9 Serial Hardware and Software for Windows T roubleshooting Diagnostic Messages This section lists possible error messages returned by the diagnostic utility , along with so lutions. No National Instruments Serial Port Found If the No National Instruments seria ...

  • National Instruments AT - page 169

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-10 ni.com Diagnostic Utility Does Not Show All Installed Ports If the diagnostic utility does not show all the ports you installed, complete the following steps: 1. V erify the hardware resources, as follows: a. In the Device Manager t ab, under Multi-fun ...

  • National Instruments AT - page 170

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-11 Serial Hardware and Software for Windows Resolving Resource Conflicts with Legacy Boards Resource conflicts typically occur if your system contains legac y boards that use resources that are not reserved properly . If a resource conflict exists, write do wn t ...

  • National Instruments AT - page 171

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-12 ni.com 5. Select the interface that W indo ws Me/9 x did not detect, as shown in Figure D-2. (This example sho ws a P CI interface.) Figure D-2. Ports List in Dev ice Manager 6. Click on the Remov e button. 7. Click on the OK button to remove the seria ...

  • National Instruments AT - page 172

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-13 Serial Hardware and Software for Windows A T and PCMCIA Hardware If Windows does not detect your serial hardware correctly, or you have been using your serial hardware with the default Windows Me/9 x serial driver or an older version of the NI-Serial softw ar ...

  • National Instruments AT - page 173

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-14 ni.com Figure D-3. Ports List in Dev ice Manager 7. Click on the Remove button, and click on OK to confirm the remov al of the serial hardware information. Repeat steps 6 and 7 until all s erial board entries are removed. Then, click on Refresh to forc ...

  • National Instruments AT - page 174

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-15 Serial Hardware and Software for Windows How can I determine which version of the NI-Serial softwar e I hav e installed? The Read Me file gi ves the version of the software. T o open the file, select Start » Programs » National Instruments Serial » Read Me ...

  • National Instruments AT - page 175

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-16 ni.com How do I change the r esources assigned to the serial interface? ♦ PCI and PXI Boards The PCI and PXI serial boards are configured as devices belonging to the multi-function adap ters class. The multi-function parent device is listed under the ...

  • National Instruments AT - page 176

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-17 Serial Hardware and Software for Windows Figure D-4. Multi-Function Adapter Class in the Device Ma nager How do I remo ve inf orm ation about serial boa rds from the Device Manager? Refer to the hardware uninstallation section for your hardware platform and o ...

  • National Instruments AT - page 177

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-18 ni.com Windows NT Missing Serial Port in the niports List PCI and PXI Boards The serial configuration utility contains configuration information fo r serial hardware that is installed in your system. T o start the configuration utility , select Start ? ...

  • National Instruments AT - page 178

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-19 Serial Hardware and Software for Windows PCMCIA Boards The serial configuration utility niports co ntains configuration information for serial hardware it is aw are of that is installed in your system. T o start the configuration utility , select Start » Set ...

  • National Instruments AT - page 179

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-20 ni.com T roubleshooting Diagnostic Messages This section lists possible error messages returned by the diagnostic utility , along with so lutions. No National Instruments Serial Port Found If the No National Instruments serial port found error message ...

  • National Instruments AT - page 180

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-21 Serial Hardware and Software for Windows Diagnostic Utility Does Not Show All Installed Ports If the diagnostic utility does not show all the ports you installed, complete the following steps: 1. V erify the hardware resources, as follows: a. Select Start » ...

  • National Instruments AT - page 181

    Appendix D T roubleshootin g and Common Questions Serial Hardware and S oftware for Window s D-22 ni.com Interrupt T est Failed If the Interrupt test failed error message appears, you might have an IRQ conflict with legacy boards in your system. T o solve this problem, change the IRQ lev el assigned to your leg acy boards. F o r instructions on how ...

  • National Instruments AT - page 182

    Appendix D T roubleshooting and Com mon Questions © National Instruments Corporation D-23 Serial Hardware and Software for Windows What is the maximum baud rate supported and how can I set it? The maximum baud rate supported i s 460.8 Kbaud for RS-485 and 115.2 Kbaud for RS-232. T o set the baud rate, use the SetCommState W in32 function a nd pass ...

  • National Instruments AT - page 183

    © National Instruments Corporatio n E-1 Serial Hardware and Software for Windows E Specifications This appendix describes the characteristics of the serial hardware, the NI-Serial software, along with the recommended operating conditions. PCI Serial Hardware T wo-Port Boards Dimensions................... .............. ............ 10.67 by 14.22 ...

  • National Instruments AT - page 184

    Appendix E Specifications for PCI Serial Hardware Serial Hardware and Software for Windows E-2 ni.com Power requirement (from PCI channel ) PCI-485/2 +5 VDC ........................ ............800 mA typical 1300 mA maximum PCI-232/2 +5 VDC ........................ ............400 mA typical 650 mA maxim um Four -Port Boards Dimensions ........... ...

  • National Instruments AT - page 185

    Appendix E Specifications for PCI Serial Hardware © National Instruments Corporatio n E-3 Serial Hardware and Software for Windows Power requirement (from PCI channel ) PCI-485/4 +5 VDC..................... .............. . 1000 mA typical 1500 mA maximum PCI-232/4 +5 VDC ..................... ............... 500 mA typical 750 mA maxim um Eight-P ...

  • National Instruments AT - page 186

    Appendix E Specifications for PCI Serial Hardware Serial Hardware and Software for Windows E-4 ni.com Environmental Characteristics Operating environment Component temperature ............ ......0 to 70 ° C Relative humidity ................ ............10 to 90%, noncondensing Storage environment Temperature......................... ............ ...

  • National Instruments AT - page 187

    Appendix E Specifications for PXI Serial Hardware © National Instruments Corporatio n E-5 Serial Hardware and Software for Windows PXI Serial Hardware T wo-Port Boards Dimensions................... ......................... . 100 b y 160 mm ( 3 . 9 4b y6 . 3 0i n . ) I/O connector................... .............. ......... DB-9 Power requirement ...

  • National Instruments AT - page 188

    Appendix E Specifications for PXI Serial Hardware Serial Hardware and Software for Windows E-6 ni.com PXI-8421/4 +5 VDC ........................ ............350 mA typical 750 mA maxim um PXI-8422/4 +5 VDC ........................ ............500 mA typical 750 mA maxim um PXI-8423/4 +5 VDC .................. ..................1000 mA typical 1500 ...

  • National Instruments AT - page 189

    Appendix E Specifications for PXI Serial Hardware © National Instruments Corporatio n E-7 Serial Hardware and Software for Windows Environmental Characteristics Operating environment Component temperature .................. 0 to 70 ° C Relative humidity ........................... . 10 to 90%, noncondensing Storage environment Temperature ....... ...

  • National Instruments AT - page 190

    Appendix E Specifications for PCMCIA Serial Hardware Serial Hardware and Software for Windows E-8 ni.com PCMCIA Serial Hardware Hardware Specifications Dimensions ................ ......................... .... 85.6 by 54.0 b y 0.5 cm (3.370 b y 2.126 by 0 .197 in.) I/O connector ................... .......................Special cable with DB-9 Ds ...

  • National Instruments AT - page 191

    Appendix E Specifications for A T Serial Hardware © National Instruments Corporatio n E-9 Serial Hardware and Software for Windows A T Serial Hardware Hardware Characteristics T wo-Port A T Serial Boards (Nonisolated) Dimensions................... .............. ............ 10.67 by 16.51 cm (4.2 by 6.5 in.) I/O connector................... ..... ...

  • National Instruments AT - page 192

    Appendix E Specifications for A T Seria l Hardware Serial Hardware and S oftware for Window s E-10 ni.com Four -Port A T Serial Boards (Nonisolated) Dimensions ................ ............................ . 10.67 by 16.51 cm (4.2 by 6.5 in.) I/O connector 1 .................. .......................10-position modular jack Power Requirement (from ...

  • National Instruments AT - page 193

    Appendix E Specifications for A T Serial Hardware © National Instruments Corporation E-11 Serial Hardware and Software for Windows Environmental Characteristics Operating environment Component temperature .................. 0 to 70 ° C Relati ve humidity ........................ .... 10 to 90%, noncondensing Storage en vironment T emperature .... ...

  • National Instruments AT - page 194

    © National Instruments Corporatio n F-1 Serial Hardware and Software for Windows F T echnical Support Resources W eb Support National Instruments W eb support is your first stop for help in solving installation, configuration, and application pro blems and questions. O nline problem-solving and di agnostic resources include f requently asked quest ...

  • National Instruments AT - page 195

    Appendix F T echnical Support Resour ces Serial Hardware and Software for Windows F-2 ni.com W orldwide Support National Instruments has of fices located around the world to help address your support needs. Y ou can access our branch of fice W eb sites from the W orldwide Of fices section of ni.com . Branch of fice W eb sites pro vide up-to-date co ...

  • National Instruments AT - page 196

    © National Instruments Corporation G-1 Serial Hardware and Software for Wind ows Glossar y Pref ix Meaning V alue p- pico- 10 – 12 n- nano- 10 – 9 µ- micro- 10 – 6 m- milli- 10 – 3 k- kilo- 10 3 M- mega- 10 6 G- giga- 10 9 t- tera- 10 12 ° degrees Ω ohms % percent A amperes ANSI American Nationa l Standards Institute bb i t s Bb y t e ...

  • National Instruments AT - page 197

    Glossary Serial Hardware and Software for Windows G-2 ni.com DCD data carrier detect DCE data communications equipment or data circuit-termin ating equipment DLL dynamic link library DMA direct memory access DSR data set ready DTE data terminal equipment DTR data terminal ready — the overscore denotes that the signal is activ e low duplex the mea ...

  • National Instruments AT - page 198

    Glossary © National Instruments Corporation G-3 Serial Hardware and Software for Wind ows MB megab ytes o f memory PC personal computer PCI Peripheral Components I nterconnect RAM random-access memory RI ring indicator R TS request to send RX recei ve RXD recei ve data — the ov erscore deno tes that the signal is act i ve low s seconds SCSI Smal ...

  • National Instruments AT - page 199

    © National Instruments Corporatio n I-1 Serial Hardware and Software for Windows Index Numerics 100-pin connector, A-8 pin descriptions (table), A-9 pin locations (figure), A-8 10-position modular ja ck, A-3 pin descriptions (table), A-3 pin locations (figure), A-3 16-port boards specifications PCI, E-3 PXI, E-6 68-pin connector, A-6 pin descripti ...

  • National Instruments AT - page 200

    Index Serial Hardware and Software for Windows I-2 ni.com common question s changing resources assigned to serial interface, D-16 determining number of interrupt s required for a serial interface, D-17, D-23 determining port associated with COM x Windows 2000, D -4 Windows Me/9 x ,D - 1 5 Windows NT, D-22 determining type of serial hardware install ...

  • National Instruments AT - page 201

    Index © National Instruments Corporatio n I-3 Serial Hardware and Software for Windows determining port associated with COM x Windows 2000, D -4 Windows Me/9 x , 4-12, 5-14, D-15 Windows NT, 4-18, 5-21, D-2 2 determining type of serial hardware i nstalled Windows 2000, D -4 Windows Me/9 x ,D - 1 4 Windows NT, D-22 determining version of NI-S erial ...

  • National Instruments AT - page 202

    Index Serial Hardware and Software for Windows I-4 ni.com forcing Windows to detect h ardware Windows 2000, D -2 Windows Me/9 x ,D - 1 1 four-port boards connecting cables to (figure), A-5 isolated four-port boards AT, E-10 PCI, E-2 specifications AT, E-10 PCI, E-2 PXI, E-5 four-wire mode, 6-2 freeing an interrupt request level, D-6 full duplex, B- ...

  • National Instruments AT - page 203

    Index © National Instruments Corporatio n I-5 Serial Hardware and Software for Windows I installation AT serial board installation (fig ure), 5-3, 5-11, 5-20 determining port associa ted with COM x Windows Me/9 x , 4-12, 5-14 Windows NT, 4-18, 5-21 getting started, 1-2 installing the Pn P ISA Enabler Driver, 5-18 PCI serial board installati on (fi ...

  • National Instruments AT - page 204

    Index Serial Hardware and Software for Windows I-6 ni.com M maximum supported baud rate Windows 2000, D -5 Windows Me/9 x ,D - 1 7 Windows NT, D-23 Measurement Studio, 1-8 missing serial port i n the niports list, D-18 modular jack connector, A-3 pin descriptions (table), A-3 pin locations (figure), A-3 multidrop ne twork using te rminating resi st ...

  • National Instruments AT - page 205

    Index © National Instruments Corporatio n I-7 Serial Hardware and Software for Windows PCMCIA, Windows Me/9 x ,4 - 1 5 PXI, Windows Me/9 x ,3 - 1 6 advanced settings AT, Windows 2000, 5-8 PCI, Windows 2 000, 2-8 PCMCIA, Windows 2000, 4-7 PXI, Windows 200 0, 3-7 PCI, Windows 2 000, 2-6 PCI, Windows M e/9 x ,2 - 1 6 PCMCIA, Windows 2000, 4-6 PCMCIA, ...

  • National Instruments AT - page 206

    Index Serial Hardware and Software for Windows I-8 ni.com serial hardwa re forcing Windows to detect Windows 2000, D -2 Windows Me/9 x ,D - 1 1 general programming requirem ents, 6-1 installation AT, Windows 2000, 5-2 AT, Windows Me/9 x ,5 - 1 0 AT, Windows NT, 5-19 PCI, Windows 2 000, 2-2 PCI, Windows M e/9 x ,2 - 1 0 PCI, Windows N T, 2-18 PCMCIA ...

  • National Instruments AT - page 207

    Index © National Instruments Corporatio n I-9 Serial Hardware and Software for Windows eight-por t boards PCI, E-3 PXI, E-6 environmental characteristics AT, E-11 PCI, E-4 PXI, E-7 four-port boards AT, E-10 PCI, E-2 PXI, E-5 isolated four-port boards AT, E-10 PCI, E-2 isolated two-port bo ards AT, E-9 PCI, E-1 PCI, E-1 PCMCIA, E-8 PXI, E-5 softwar ...

  • National Instruments AT - page 208

    Index Serial Hardware and S oftware for Window s I-10 ni.com PCI, E-1 PXI, E-5 two-wire devices, A-1 connecting, A-1 typical full-duplex system ( figure), B-4 typical half-duplex system (figure), B-4 U uninstalling serial hard ware AT Windows Me/9 x ,C - 1 8 AT, Windows 2000, C-1 7 AT, Windows NT, C-20 PCI, Windows 2 000, C-2 PCI, Windows M e/9 x , ...

Manufacturer National Instruments Category Computer Hardware

Documents that we receive from a manufacturer of a National Instruments AT can be divided into several groups. They are, among others:
- National Instruments technical drawings
- AT manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments AT
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments AT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments AT, service manual, brief instructions and user manuals National Instruments AT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments AT.

A complete manual for the device National Instruments AT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments AT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments AT.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments AT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments AT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments AT, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments AT - which should help us in our first steps of using National Instruments AT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments AT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments AT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments AT?

Use the form below

If you did not solve your problem by using a manual National Instruments AT, ask a question using the form below. If a user had a similar problem with National Instruments AT it is likely that he will want to share the way to solve it.

Copy the text from the picture