    A PPLICATION & SERVICE GUIDE HFC Refrigerant R410a Used In GeoMax2 Geothermal Heat Pump Systems ...

  • Heat Controller R410A - page 2

    Page 2 R410a Application and Service Guide T able 1. R407c Pressur e/T emperature Chart Although the bulk of this manual is information regarding R410a, R407c will also be discussed for purposes of comparison and since it is one of the so- called new refrigerants. R410a Overview R410a is a non-chlorine based (HFC) refrigerant, that with R407c and R ...

  • Heat Controller R410A - page 3

    Page 3 R410a Application and Service Guide Component Considerations for R410a Compressor W all thickness has increased with the increase of operat- ing pressures of R410a. The internal pressure relief valve setting has been increased from 375-450 psig for R22 to 550-625 psig for R410a. Although the discharge pressure is higher in R410a the discharg ...

  • Heat Controller R410A - page 4

    Page 4 R410a Application and Service Guide • A vacuum pump will not adequately remove mois- ture from the POE lubricants. Use a  lter drier and replace whenever the system is opened. • POEʼ s can be irritating to the skin • POEʼ s can damage some roo ng membrane materi- als • POEʼ s are better solvents than mineral oils • Leave P ...

  • Heat Controller R410A - page 5

    Page 5 R410a Application and Service Guide • 35% annual leak rate of commercial and industrial refrigeration • 15% annual leak rate comfort cooling chillers and all other equipment R407c Considerations R407c equipment for leak detection are the same as R410a. However , the technician CANNOT use the exist- ing refrigerant in the system after lea ...

  • Heat Controller R410A - page 6

    Page 6 R410a Application and Service Guide An overcharged TXV unit can be identi ed by: • High subcooling • High head pressures Even though R410a has a very small fractionation po- tential it cannot be ignored completely when charging. T o avoid fractionation , charging a system with R410a should be done with LIQUID from the tank to maintain ...

  • Heat Controller R410A - page 7

    Page 7 R410a Application and Service Guide 4. Measure the suction line temperature just prior to entering the compressor . 5. Subtract the saturation temperature from the suc- tion temperature to  nd the superheat. Consult T able 4 for appropriate values. 6. If the superheat is too high then unit might still be undercharged. T XV 's will ma ...

  • Heat Controller R410A - page 8

    SAFETY AND HANDLING OVERVIEW ASHRAE Standard 15 details safety precautions when handling refrigerants in commercial systems and should be read and understood. Refrigerants are especially dan- gerous in con ned spaces. • R410a has a much higher pressure ( + 60%) associated with its operation . Use caution when handling and ensure proper tools a ...

  • Heat Controller R410A - page 9

    1900 Wellworth Ave., Jackson, Michigan 49203 • Ph. 517-787-2100 • Fax 517-787-9341 THE QUALITY LEADER IN CONDITIONING AIR www.heatcontroller.com 02 /07 ...

Manufacturer Heat Controller Category Heat Pump

Documents that we receive from a manufacturer of a Heat Controller R410A can be divided into several groups. They are, among others:
- Heat Controller technical drawings
- R410A manuals
- Heat Controller product data sheets
- information booklets
- or energy labels Heat Controller R410A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heat Controller R410A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heat Controller R410A, service manual, brief instructions and user manuals Heat Controller R410A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heat Controller R410A.

A complete manual for the device Heat Controller R410A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heat Controller R410A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heat Controller R410A.

A complete Heat Controller manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heat Controller R410A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heat Controller R410A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heat Controller R410A, that we can find in the current document
3. Tips how to use the basic functions of the device Heat Controller R410A - which should help us in our first steps of using Heat Controller R410A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heat Controller R410A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heat Controller R410A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heat Controller R410A?

Use the form below

If you did not solve your problem by using a manual Heat Controller R410A, ask a question using the form below. If a user had a similar problem with Heat Controller R410A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)