    INSTALLATION MANUAL R410A Split Series Models 2MXS40G2V1B 2MKS40G2V1B 2MXS40H2V1B 2MKS40H2V1B 2MXS40H3V1B 2MKS50G2V1B 2MXS50G2V1B 2MKS50H2V1B 2MXS50H2V1B 2MXS50H3V1B 2AMX40F2V1B 2AMX40G2V1B 2AMX40G3V1B 2AMX50F2V1B 2AMX50G2V1B 2AMX50G3V1B Deutsch Français Nederlands Español Italiano Ελληνικ Ü Portugues Р ó сс ê ий English Türkçe I ...

  • Daikin 2AMX50G3V1B - page 2

    Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan 3SB64417-5A 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B 2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B D AIKIN INDUSTRIES, L TD. Noboru Murata Manager Quality C ...

  • Daikin 2AMX50G3V1B - page 3

    Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan D AIKIN INDUSTRIES, L TD. EN60335-2-40, DAIKIN.TCF .015 P6/07-2012 DEKRA Certification B.V . (NB0344) 74736-KRQ/EMC97-4957 3SB65451-10D Shinri Sada Manager Quality Control Depar tment 2MXS40H3V1B, 2MXS50H3V1B, 2AMX40G3V1B, 2AMX50G3V1B Machinery 2006/42/EC ** Electromagnetic ...

  • Daikin 2AMX50G3V1B - page 4

    3SB65451-4.fm Page 2 Thursd ay, October 27, 2011 4:49 PM ...

  • Daikin 2AMX50G3V1B - page 5

    1 ■ English Safety Precautions • The precautions descri bed herein are classified as W ARN ING and CAUTION. They both contain important informa - tion regarding safety . Be sure to observe all precau tions without fail. • Meaning of W ARNING and CAUTION no tices W ARN ING .... Failure to follow these instructions pr operly may result in perso ...

  • Daikin 2AMX50G3V1B - page 6

    ■ English 2 Accessories Accessories supplied wit h the outdoor unit: Precautions for Selecting the Location 1) Choose a place soli d enough to bear th e weight and vibratio n of the uni t, where the operation noi se will not be ampli fied. 2) Choose a location where the hot air discharged from the unit or the operation noi se, will not cause a nu ...

  • Daikin 2AMX50G3V1B - page 7

    3 ■ English Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the insta llation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.) CAUTION • Do not connect the embedded bran ch piping and the outdoor unit when only carrying out piping w ork without connecting the indo ...

  • Daikin 2AMX50G3V1B - page 8

    ■ English 4 Installation • Install the unit horizontally . • The unit may be installed directly on a concrete verandah or a solid place if drai nage is good. • If the vibration may possibly be transmitted to the bu ilding, use a vibration-pr oof rubbe r (field supply). 1. Connections (connection por t) Install the indoor unit according to t ...

  • Daikin 2AMX50G3V1B - page 9

    5 ■ English Outdoor Unit Installation Guideline • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow , follow the instal lation guidelines be low . • For any of the below installation pattern s, the wall height on the exhaust side should be 120 0mm or less. Selecting a Location for Installation of the In ...

  • Daikin 2AMX50G3V1B - page 10

    ■ English 6 Refrigerant Piping W ork 1. Installing outdoor unit 1) When installing the outdoor unit, refer to “Precautions for Se lecting the Location” on page 2 and the “Indoor/Outdoor Unit Installation Drawings” on p age 3. 2) If drain work is ne cessary , follow the procedures below . 2. Drain work (only heat pump models) 1) Use the dr ...

  • Daikin 2AMX50G3V1B - page 11

    7 ■ English Refrigerant Piping W ork 4. Purging air and ch ecking gas leakage WARNING • Do not mix any substance other tha n the specifie d refrigerant (R410A) into the refrigera tion cycle. • When refrigerant gas leaks occur , ventilate the room as soon and as much as possible. • R410A, as well as other refrigerants, should always be reco ...

  • Daikin 2AMX50G3V1B - page 12

    ■ English 8 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410 A Fill from th e gas pipe i n liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, p reventing normal operatio n. 1) Before filling, check wheth er th ...

  • Daikin 2AMX50G3V1B - page 13

    9 ■ English Refrigerant Piping W ork Precautions for Laying Refrigerant Piping • Cautions on pipe handling 1) Protect the open end of the pipe against du st and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. • Selection of copper and heat insulat ion materials When using commercial copper pipes and ...

  • Daikin 2AMX50G3V1B - page 14

    ■ English 10 Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap s on the liquid an d the gas stop valves at the pipes for rooms A and B. 2) Run the unit on forced cooling. (Refer to the below .) 3) After 5 to 10 minutes, close the liquid stop valves at th ...

  • Daikin 2AMX50G3V1B - page 15

    11 ■ English Wir ing WARNING • Do not use tapped wire s, stranded wires ( CAUTION 1)), extension co rds, or starburst co nnections, as they may cau se over- heating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the produc t. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing ...

  • Daikin 2AMX50G3V1B - page 16

    ■ English 12 Maximum Power Input Limitation Setting WARNING Always shut off the power supply breaker before starting. • The Maximum Power Input Limitation needs to be set when the unit is installed. • This function limi ts the power input of the unit to 1700W . • It is recommended for locations with low-capaci ty circuit breakers. CAUTION T ...

  • Daikin 2AMX50G3V1B - page 17

    13 ■ English ECONO Mode Prohibition Setting WARNING Always shut off the power supply breaker before starting. • This setting disables the inp ut control signal from the remote controller . • Use this setting when you wish to block receptio n of input controls (cooling/heating) from indoor unit remote co ntrollers. • Set as follows. 1) Remov ...

  • Daikin 2AMX50G3V1B - page 18

    ■ English 14 T rial Operation and T esting • Before starting the test run, measure the voltag e at the primary side of the safety breaker . • Check that all liquid and gas stop valves are fully open. • Check that pipi ng and wiring all match. 1. T rial operation and testing 1) T o test cooling, set for the lowest temp erature. T o test heat ...

  • Daikin 2AMX50G3V1B - page 19

    (1210) HT 3P210724-1F M07B062F Two-dimensio nal bar code is a code for manufact uring. 00_CV_3P210724-1F.fm Page 2 Tu esday, October 30, 2012 10: 36 AM ...

Manufacturer Daikin Category Air-conditioning

Documents that we receive from a manufacturer of a Daikin 2AMX50G3V1B can be divided into several groups. They are, among others:
- Daikin technical drawings
- 2AMX50G3V1B manuals
- Daikin product data sheets
- information booklets
- or energy labels Daikin 2AMX50G3V1B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Daikin 2AMX50G3V1B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Daikin 2AMX50G3V1B, service manual, brief instructions and user manuals Daikin 2AMX50G3V1B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Daikin 2AMX50G3V1B.

Similar manuals

A complete manual for the device Daikin 2AMX50G3V1B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Daikin 2AMX50G3V1B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Daikin 2AMX50G3V1B.

A complete Daikin manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Daikin 2AMX50G3V1B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Daikin 2AMX50G3V1B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Daikin 2AMX50G3V1B, that we can find in the current document
3. Tips how to use the basic functions of the device Daikin 2AMX50G3V1B - which should help us in our first steps of using Daikin 2AMX50G3V1B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Daikin 2AMX50G3V1B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Daikin 2AMX50G3V1B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Daikin 2AMX50G3V1B?

Use the form below

If you did not solve your problem by using a manual Daikin 2AMX50G3V1B, ask a question using the form below. If a user had a similar problem with Daikin 2AMX50G3V1B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)