    Ocarina/Castanet Analog Servo Drives Installation Guide April 2008 - Ver. 1.2 www.elmomc.com ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 2

    Notice This guide is de livered subject to th e following conditions and re strictions:  This guide con tains proprietary info rmation belonging to Elmo Motion Control Ltd. Such inf ormation is supplied s olely for the pu rpose of ass isting users of the Ocarina and Castanet servo drives in their installation.  The text and graph ics included ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 3

    Contents Chapter 1: Safet y Informatio n ............................................................................................... 1-1 1.1 Warn ings .................................................................................................................... 1-2 1.2 Cautions ............................................................. ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 4

    4.3.2 External Resis tor ............................................................................................... 4-2 4.3.3 External C urrent Limit - P eak (ECLP) ........................................................... 4-2 4.3.4 External Volt age ............................................................................................ ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 5

    Chapter 1: Safety Information In order to achieve the optimum, safe operation of the Ocarina and Castanet servo- amplifiers, it is impe rative that you implemen t the safe ty procedures inc luded in this installation guide. Th is information is provided to protect you and to keep your w ork area safe when operating the Ocarina and Castanet and acco ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 6

    1.1 Warnings To avoid electric arcing and hazards to personnel and electrical contacts, never connect/disconnect the servo drive while the power source i s on. Power cables can carry a high voltage, even when t he motor i s not in motion. Disconnect the Ocarina and Castanet from all voltage sources before they are opened for servicing. The Ocarina ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 7

    1.3 Directives and Standards The Ocarina and Castanet conform to the following industry safety standards: Safety Standard Item In compliance with UL508c Power Conversion Equipment In compliance with UL840 Insulation Coordination, Including Clearance and Creepage Distances of Electri cal Equi pment In compliance with UL60950-1 (formerly UL1950) Safe ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 8

    Ocarina/Castanet Install ation Guide Introduction MAN-O CSIG (Ver. 1.2) 2-1 Chapter 2: Introduction This Installation Guide is inten ded for design e ngineers w ho are integrating an Elmo Motion Control Ocarina and Castanet servo amplifiers into a machine. 2.1 Product Description The Oc ari na and Ca sta net series of servo-amplifiers was designed ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 9

    Ocarina/Castanet Install ation Guide Introduction MAN-O CSIG (Ver. 1.2) 2-2 • Weight: Ocarina – 1.6 oz (45g), Castanet – 0.76 oz (21.5 grams) 2.3 Fault Protection Built-in protection again st possible f ault conditions, in cluding: • Shorts betwe en the outputs or be tween each output and the power input/ return • Over-heating • Under/o ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 10

    Chapter 3: Installation 3.1 Before You Begin 3.1.1 Site Requirements You can guarantee the safe operation of the Ocarina and Castanet by ensuring that they are installed in an appropriate environment. Feature Value Ambient operating temperature 0 °C – 50 °C (32 °F – 122 °F) Maximum rel ative humidi ty 90% non-condensing Operating area atmos ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 11

    3.3 Dimensions 3.3.1 Ocarina Dimensions Figure 3-1: Ocarina Dimensions 3.3.2 Castan et Dimensions Figure 3-2: Castanet Dimensions Ocarina/Castanet Install ation Guide Insta llation MAN-O CSIG (Ver. 1.2) 3-2 ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 12

    3.4 Mounting 3.4.1 Ocarina The Ocarina was designed for mounting on a printed circuit board (PCB). It is connected by 2 mm pitch 0.51 mm square pins. When designing the Ocarina into a device, be sure to leave about 1 cm (0.4") outward from the heatsink to enable free air convection around the Ocarina. We recommend that the Ocarina be soldered ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 13

    3.5 Integrating the Ocarina and Castanet on a PCB The Oc arin a an d C astan et are designed to be mounted on a PCB, either by soldering its pins directly to the PCB or by using suitable soc ket conne ctors. In both ca ses the following rule s apply: 3.5.1 Trac es 1. The size of the traces on the PCB (thickne ss and width) is determined by the curr ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 14

    4. PE Terminal : The PE terminal is connected directly to the Ocarina's heatsink or to the Castanet's two PE strips on its lower board. In the Ocarina, the heatsink serves as an EMI common plane. The PE termi nal should be connected to the system's Protective Earth. Any other me tallic parts (such as the chas sis) of the assembly sho ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 15

    3.6.2 Connector J1 Pin # Short Form Function Description 1 EN+ Enable + Positive voltage input of the “Amplifier Enable” function. To enable operation of the amplifier, the optocouple r must be energi zed by applying voltage between this pin (+) and pin J1/22 (-). The optocouple r is isolated from the amplifier. See Figure 3-4. “OFF” voltag ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 16

    Pin # Short Form Function Description 14 ECLP External current limit peak External voltage scales down the rated value. Voltage range: 0 V to 3.75 V (3.75 V = rated Ip) Refer to Section 4.2. 15 LMRET Latch Mode return Return for Latch Mode s ignals. 16 GAIN Current gain change Shorting this pin to LMRET pin (J1/15) reduces the proportional gain of ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 17

    3.7 Ocarina/Castanet Connection Diagram Figure 3-3: Ocarina/Castanet Connection Diagram Ocarina/Castanet Install ation Guide Insta llation MAN-O CSIG (Ver. 1.2) 3-8 ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 18

    3.8 Main Power and Motor Power P in Function Cable Pin Positions VP+ Pos. Power input Power PR Power return Power PE Protective earth Power AC Motor DC Motor PE Protective earth Motor Motor M1 Motor phase Motor N/C M2 Motor phase Motor Motor M3 Motor phase Motor Motor When con necting se veral amplifiers to s everal motors, all sh ould be wired in ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 19

    3.10 DC Power Supply The DC power supply can be at any voltage i n the range defined in the technical specif ications (th e Appendix of this guide). The supply source must comp ly with the safet y aspects of the relevant requiremen ts, in accordance with the most recent version of the standard EN60950 or equivalent Low Voltage Directive Standard, a ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 20

    Figure 3-4: Detailed Ocarina/Castanet Internal Block Diagram Ocarina/Castanet Install ation Guide Insta llation MAN-O CSIG (Ver. 1.2) 3-11 ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 21

    3.11 Heat Dissipation 3.11.1 Ocarina The best way to di ssipate heat from the Ocarina i s to mount it so that its heatsink faces up. For best results leave approximately 10 mm of space between the Ocarina's heatsink and any other assembl y. 3.11.1.1 Thermal Data • Heat dissipation capability ( θ ): Approximately 10 ° C/W. • Thermal time ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 22

    Whi st le 100 Ser ies P ower D is s ipat io n 0.0 1.0 2.0 3.0 4.0 5.0 6.0 0 0. 5 1 1.5 2 2. 5 3 3. 5 4 4. 5 5 P e ak Curr ent (A) P o w er D i ss i pati on (W ) 85V DC 70V DC 50V DC 3.11.1.3 How to Use the Charts The charts above are based upon theoretical worst-case con ditions. Actual tes t results show 30% - 50% better power dissipation. To dete ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 23

    Chapter 4: Servo Control Operation 4.1 Ocarina/Castanet Connected to DC Motors In order to connect the Ocarina or Castanet to a DC motor, connect Hall A (J1 pin 4 of the drive) to Hall return (J1 pin 17 of the drive). The motor should be connected to M2, M3. 4.2 Current Command Input The Ocarina and Castanet have a single differential input. The in ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 24

    4.3.2 Exte rnal Resistor Connect an external resistor between terminal J1/9 (ECLC) and terminal J1/8 (ECLRET). The resistor va lue is given by: 0 < RECLC < 36.4 K (1/8 Watt) At RECLC greater than 36.4 K, the current limit will be internally clamped to the nominal value. IC(nom) is the nomin al continuo us curren t limit of the amplifie r. 4.3 ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 25

    4.3.5 Exte rnal Resistor Connect an external resistor between terminal J1/14 (ECLP) and terminal J1/8 (ECLRET). The resistor va lue is given by: 0 < R ECLP < 36.4 K (1/8 Watt) At RECLP greater than 36.4 K, the current limit will be internally clamped to the nominal value. IP(nom) is the nomina l peak current limit of th e amplifier. 4.3.6 Lat ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 26

    Function Latch Option AOK SO1 SO2 SO3 10 Power up reset No Open collector Open collector Open collector Open collector 11 Commutation failure Yes Open collector Low Low Low * This indication can be used as a digita l input for activating an external shunt regulator. Table 4-1: Ocarina/Castanet Status Indications Notes:  Without latch mode: The s ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 27

    Appendix: Specifications A.1 General Specifications A.1 .1 Ocarina Feature Units 1/60 2.5/60 5/60 10/60 15/60 1/100 2.5/100 5/100 10/100 15/100 Minimum supply voltage VDC 11 20 Nominal supply voltage VDC 50 85 Maximum supply voltage VDC 59 95 Maximum continuous power output W 55 140 280 570 850 90 230 460 920 1400 Efficiency at rated power (at nomi ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 28

    A.1.2 Ca stanet Feature Units 3/60 2.5/100 Minimum supply voltage VDC 11 20 Nominal supply voltage VDC 50 85 Maximum supply voltage VDC 59 95 Maximum continuous power output W 190 240 Efficiency at rated power % Up to 99% Maximum o utput voltage 93% of DC bus voltage at f=32 kHz DC and trapezoi dal commutation continuous current limit (Ic) A 3.3 2. ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 29

    A.2 Standards Compliance A.2.1 Q uality Assurance Specification Details ISO 9001:2000 Quality Management A.2.2 D esign Specification Details MIL-HDBK- 217F Reliability prediction of electronic equipment (rating, de-rating, stress, etc.) IPC-D-275 IPC-SM-782 IPC-CM-770 UL508c UL840 Printed wiring for elect ronic equipment (clearance, creepage, spaci ...

  • Elmo MAN-OCSIG (Ver. 1.2) - page 30

    A.2.4 EMC Specification Details In compliance with EN55011 Class A with EN61000-6-2: Immunity for in dustrial environment, according to: IEC61000-4-2 / criteria B IEC61000-4-3 / criteria A IEC61000-4-4 / criteria B IEC61000-4-5 / criteria B IEC61000-4-6 / criteria A IEC61000-4-8 / criteria A IEC61000-4-11 / criteria B/C Electromagnetic compatibilit ...

Manufacturer Elmo Category Music Mixer

Documents that we receive from a manufacturer of a Elmo MAN-OCSIG (Ver. 1.2) can be divided into several groups. They are, among others:
- Elmo technical drawings
- MAN-OCSIG (Ver. 1.2) manuals
- Elmo product data sheets
- information booklets
- or energy labels Elmo MAN-OCSIG (Ver. 1.2)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Elmo MAN-OCSIG (Ver. 1.2).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Elmo MAN-OCSIG (Ver. 1.2), service manual, brief instructions and user manuals Elmo MAN-OCSIG (Ver. 1.2). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Elmo MAN-OCSIG (Ver. 1.2).

Similar manuals

A complete manual for the device Elmo MAN-OCSIG (Ver. 1.2), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Elmo MAN-OCSIG (Ver. 1.2) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Elmo MAN-OCSIG (Ver. 1.2).

A complete Elmo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Elmo MAN-OCSIG (Ver. 1.2) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Elmo MAN-OCSIG (Ver. 1.2), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Elmo MAN-OCSIG (Ver. 1.2), that we can find in the current document
3. Tips how to use the basic functions of the device Elmo MAN-OCSIG (Ver. 1.2) - which should help us in our first steps of using Elmo MAN-OCSIG (Ver. 1.2)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Elmo MAN-OCSIG (Ver. 1.2)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Elmo MAN-OCSIG (Ver. 1.2) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Elmo MAN-OCSIG (Ver. 1.2)?

Use the form below

If you did not solve your problem by using a manual Elmo MAN-OCSIG (Ver. 1.2), ask a question using the form below. If a user had a similar problem with Elmo MAN-OCSIG (Ver. 1.2) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)