    INST ALLA TION AND OPERA TING INSTRUCTIONS BERRINGT ON SOLID FUEL BOILER ST OVE This appliance is hot while in operation and retains it s heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has tho ...

  • AGA Berrington - page 2

    T ABLE OF CONTENTS P AGE NO. 1. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Pre Installation Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3. Flues . . . . . . . . . . . . . . . . . . . . . . . ...

  • AGA Berrington - page 3

    BERRINGTON SOLID FUEL STOVE INST ALLA TION & OPERA TING INSTRUCTIONS GENERAL When installing, operating and maint aining your Berrington S tove respect basic standards of fire safety . Read these instructions carefully before commencing the installation. Failure to do so may result in damage to persons and property . Consult your local Municipa ...

  • AGA Berrington - page 4

    Fig.4 2300 600 Soot Door Appliance FLUE PIPES A flue pipe should only be used to connect an appli- ance to a chimney and should not pass through any roof space. Flue pipes may be of any of the following materials: (a) Cast iron as described in BS 41: 1973 (1981), or (b) Mild steel with a wall thickness of at least 3mm, or (c) S tainless steel with ...

  • AGA Berrington - page 5

    4 REAR FLUE EXIT For the rear flue outlet configuration, push in the flue connector pipe (not supplied) into the flue outlet socket at the rear of the stove and cement into place using approved fire cement ensuring that no cement blocks the flue passageway . (See Fig.7) Fig. 6 Fig. 5 It may be necessary to have an inspection plate in the flue pipe ...

  • AGA Berrington - page 6

    5 FLOOR PROTECTION It is recommended that this appliance is installed on a solid, level, non combustible hearth conforming to current Building Regulations. Fig.7 The appliance is suitable for continuous operation on solid mineral fuel and intermittent operation on wood logs. This appliance has been tested using seasoned wood logs and manufactured b ...

  • AGA Berrington - page 7

    6 Fig 8 NOTE: Dimensions stated below may be subject to a slight +/- variation. SPECIFICA TION SPECIFICA TIONS Metric Depth 495mm Flue Outlet 152mm Fire Door Size 455x230mm Log Size 400mm TECHNICAL DA T A Boiler T apping: 1” BSP Boiler Capacity: 12.7 Litres Maximum Operating W ater Pressure 2.0 Bar Nominal Output: Wood Logs Solid Mineral Fuel Roo ...

  • AGA Berrington - page 8

    PLUMBING REGULA TIONS The plumbing must be in accordance with all relevant regulations and practices. It must include a gravity circuit with expansion pipe, open to the atmosphere. The central heating will be pump-dri- ven as with other types of boilers. GRA VITY CIRCUIT The gravity circuit consists of the domestic hot water tank of 135 litres indi ...

  • AGA Berrington - page 9

    8 (closed to maximum). Setting 4 will provide the most heat from the appliance. The zero position may not always be in the 12 o’clock position but the knob will only rotate once between fully open and fully closed. (See Fig.10) LOW / SLUMBER BURN T o achieve an overnight or a low burn rate, close the air wash slider fully by sliding the lever lef ...

  • AGA Berrington - page 10

    IMPORT ANT NOTES Now that your Solid Fuel S tove is installed and no doubt you are looking forward to many comforts it will provide, we would like to give you some tips on how to get the best result s from your stove. 1. We would like if you could t ake some time to read the operating instructions/hints, which we are confident, will be of great ben ...

  • AGA Berrington - page 11

    LIGHTING 1. Before lighting the stove, ensure that any build up of ashes in the fire box has been removed and that the ashp an has been emptied. 2. Open the firebox and cover the grate with crumpled pieces of p aper . 3. Lay pieces of kindling on top of the p aper towards the back of the fire box. 4. Open the primary air inlet by turning the contro ...

  • AGA Berrington - page 12

    11 Fig.12 DISPOSAL OF ASHES The stove is provided with a steel ashpan. This ash- pan must be emptied every day . If ashes are allowed to build up to grate level the fire- bars could be damaged by overheating. We recom- mend that you remove ashes after you have riddled the fire following an overnight burn. Note: The stove should never be operated wi ...

  • AGA Berrington - page 13

    Fig.15 3. Use only products recommended by the Vitreous Enamel Association, these products carry the Vitramel label. 4. DO NOT USE ABRASIVE P ADS OR OVEN CLEANSERS CONT AINING CITRIC ACID ON ENAMELLED SURF ACES. ENSURE THA T THE CLEANSER MANUF ACTUR- ERS INSTRUCTIONS ARE ADHERED TO. GLASS CLEANING The glass will self clean when there is sufficient ...

  • AGA Berrington - page 14

    BERRINGTON SOLID FUEL BOILER ST OVE EXPLODED VIEW 13 1. RH Side 2. Leg 3. LH Side 4. Front Frame 5. Base Panel 6. Hob 7. Ashtray Front 8. Boiler 9. Shaker Bar Sleeve 10. Air Slide Sub Assy 1 1. Ashpan 12. Ash Comp artment 13. Flexible Drive 14. Front Brick 15. Side Brick No.1 16. Side Brick No.2 17. Front Door Assy 18. Ash Door Assy 19. Thermost at ...

Manufacturer AGA Category Stove

Documents that we receive from a manufacturer of a AGA Berrington can be divided into several groups. They are, among others:
- AGA technical drawings
- Berrington manuals
- AGA product data sheets
- information booklets
- or energy labels AGA Berrington
All of them are important, but the most important information from the point of view of use of the device are in the user manual AGA Berrington.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals AGA Berrington, service manual, brief instructions and user manuals AGA Berrington. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product AGA Berrington.

Similar manuals

A complete manual for the device AGA Berrington, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use AGA Berrington by users. Manuals are usually written by a technical writer, but in a language understandable to all users of AGA Berrington.

A complete AGA manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual AGA Berrington - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the AGA Berrington, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the AGA Berrington, that we can find in the current document
3. Tips how to use the basic functions of the device AGA Berrington - which should help us in our first steps of using AGA Berrington
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with AGA Berrington
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of AGA Berrington in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning AGA Berrington?

Use the form below

If you did not solve your problem by using a manual AGA Berrington, ask a question using the form below. If a user had a similar problem with AGA Berrington it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)