Manual Jøtul GF 100 DV II, GF 200 DV II

32 pages 1.51 mb
Download

Go to site of 32

Summary
  • Jøtul GF 100 DV II, GF 200 DV II - page 1

    1 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Installation and Oper a tion Instruc tions Jøtul GF 100 D V I I Nordic Q T Jøtul GF 200 D V I I Lillehammer IF THE INFORMA TION IN THESE INSTRUCTIONS ARE NOT FOLL OWED EXACTL Y , A FIRE OR EXPLO- SION MA Y RESUL T CA USING PR OPERTY D AMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR Y OUR SAFETY : D ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 2

    2 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer W elc ome to J ø tul... Congr atulations on the purchase of your new Jøtul gas heater . W e at Jøtul are glad you’ve made the decision to warm your hearth with a Jøtul product. Y our new stove e xemplifies o ver 150 years experience as the world’ s largest manufacturer of solid fuel burnin ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 3

    3 GF 100 D V II Nordic QT GF 200 D V II Lillehammer T able of C ontents Specifications , GF 100 DV II .................. 4 Specifications , GF 200 DV II .................. 5 General Inf ormation ............................... 6 Service T ools .............................................. 6 Safety Inf ormation .................................. 7 ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 4

    4 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Jøtul GF 100 DV II Nordic QT Specifications Input Rates Natural Gas 17,000 BTU /hr . maximum input 9,900 BT U/hr . minimum input Propane 16,000 BTU /hr . maximum input 8,700 BT U/hr . minimum input Inlet Pressure : MI N M AX Natur al Gas: 5.0 WC (1.24 kP a) 7.0 WC (1.74 kP a) Propane: 12.0 WC (2. ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 5

    5 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Jøtul GF 200 D V I I Lillehammer Specifications GF 200 DV II Accessories • Fuel Conversion Kit - NG ..................................................... 155627 • High Altitude Adjustment Kit - NG ................................ 155808 • High Altitude Adjustment Kit - LP .................. ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 6

    6 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Gener al Information  THIS H EA TER MUST BE INST ALLED AN D MAINT AIN ED BY A QU ALIFI ED SERVICE AGENCY .  The installation and repair of this appliance must be done by a qualified service person. Failur e to properly install and maintain this heater could result in an unsafe or haz a r dou ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 7

    7 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Location In selecting a location for the stov e, consider the following poin ts: 1) Heat distribution 2) V ent termination requiremen ts 3) Gas supply line routing 4) T raffic are as, furniture, draperies, etc . The stove ma y be located on or near con ven- tional construction materials, however , ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 8

    8 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Sto v e and V ent Clearance Requirements Minimum Clearances from the Stov e to Combustibles: Measured from the stove top pla te. See figs. 2-4. For Both Sto ves Rear: 0” (0 mm) Ceiling: 42” (1066 mm) C orner : 2” (50 mm) Sides: 3” (76 mm) Minimum Clearances between V ent Pipe and C ombusti ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 9

    9 GF 100 D V II Nordic QT GF 200 D V II Lillehammer SEALANT V enting Requirements Both stoves ma y be installed with a vertical or horizontal termination and must conform to the configur ation requir ements described in this section. V ent components from the manufacturers listed below ar e approved f or use: • Simpson Dura- V ent GS • Selkirk ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 10

    10 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer V er tical V ent T ermina tion The Jøtul GF 100 D V I I and Jøtul GF 200 D V I I are ap- pro ved for ve rtical venting thr ough a ceiling or to a roof termination following these guidelines:  The termination should fall within the shaded ar ea of the grid depicted in fig .7 below . Maximum V ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 11

    11 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Co-linear V ent Installation This appliance may be v ented through a masonry or Class A pref abricated chimney using a Co-linear Flexible V ent system approved f or use with a solid-fuel burning fireplace. When installed in the manner described below , this system can improv e the performance of ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 12

    12 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Figur e 12. Corner Installation, Horizontal T ermination directly of f rear . Maximum Horizontal run is 2 ft. (610 mm). Horizontal V ent T ermination  W all Cut-out Opening: A minimum 10" X 10" (250 mm x 250 mm) square hole is requir ed for proper pipe clearances through a combustibl ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 13

    13 GF 100 D V II Nordic QT GF 200 D V II Lillehammer W all Shield Installation The decora tive W all Shield, included in the Miscellaneous Hardw are bag , is used to obscure the vent hole in the wall in installations v ented directly of f the rear of the stov e. F ollow this procedur e: 1. R emove the top two 1/4” he x head screw s from the rear ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 14

    14 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Figure 17 . V ent T erminal Clearances - National F uel Gas Code. Horizontal T ermination Clearance A = Clearance abov e grade, ver anda, por ch , deck, or balcony : 12 inches (30 cm) minimum. B = Clearance to window or door that may be opened: **Min. 9 inches, U .S. / *12 inches (30 cm) CAN. W e ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 15

    15 GF 100 D V II Nordic QT GF 200 D V II Lillehammer T ools required: • 1/2” open ended wrench or deep-well socket, T orx T20 or slotted screwdriv er , 4 mm allen wrench. C onversion Kit Contents: • 1, regula tor tower labeled for propane • 3, regula tor tower screw s • 1, burner orifice (GF 100: #48 for NG, #56 for LP) (GF 200: #46 for N ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 16

    16 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Gas Conv ersion Procedure 1. T urn off gas supply to stove. 2. R emove the stov e T op Plate (3). 3. GF 100 DV II Only : Remo ve the front pla te from the stove. P ull the casting str aight up and out awa y from the side panels. Pull the panel upwar d with one hand while the other pushes against ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 17

    17 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Gas Supply C onnection NO TE: If the optional Blower will be installed, use a 90° Elbow off the v alve to cr eate adequate clearance f or the main gas line. The gas supply line connection is made to the valv e just inside the left rear leg. The gas supply line should be 3/8" npt with a 1/2& ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 18

    18 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Gas Pressure Corr ec t gas pressure is essential f or ef ficient and safe opera tion. It is important that the correct pressure is established at the time of the installation. Pr oper gas pressure pr ovides a consistent flow of gas to the appli- ance and is instrumental in checking f or gas leaks ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 19

    19 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Flame Appear ance - Air Shutter Adjustment W ARN I NG: AI R SHUTTER AD JUST MENTS SHOULD ONL Y BE PERFORMED BY A QU ALIFI ED PROFESSIONAL SER VICE TECHNIC IAN. The air shutter setting at the burner orifice can be adjusted to achieve the desired flame appearance. The shutter is set in the mid-rang ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 20

    20 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Optional W all Thermosta t or Remote C ontrol Use only a 750 millivolt DC two-wire circuit thermostat with this appliance. The thermostat should be placed in the same room as the heater , typically 5 feet off the floor . Avoid dr afty areas or an y area that may aff e ct the accuracy of the therm ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 21

    21 GF 100 D V II Nordic QT GF 200 D V II Lillehammer S ystem Check 1. PURGI NG T H E GAS LI NE: When lighting the appli- ance f or the first time, it will take a few moments to clear the gas line of air . Once this purge is complete, the appliance will opera te as described in the lighting instructions. See the inside back cov er of this manual or ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 22

    22 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Maintenance This appliance and its venting system should be in- spected before use and at least annually by a qualified service technician. IMPOR T ANT : AL WA YS TURN OFF THE GAS SU PPL Y T O THE S T OVE BEFORE ANY SER VIC E W ORK IS PERFORMED ON T H E S TO VE. V ent Sy stem: The vent components ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 23

    23 GF 100 D V II Nordic QT GF 200 D V II Lillehammer MODEL NAME: ________________________ SERI AL N UMB ER: ______________________ DA TE OF PURC HASE: ___________________ PURC HASED FR OM: ____________________ NAME OF I N S T ALLER: ___________________ TYPE OF FUEL: ________________________ W AS ST OVE C ONVERTED? _______________ NO TES: R ecord th ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 24

    24 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer MANUAL AUTO OFF BLOWER Optional Blower # 155631 Installation 1. Unpack and check the con- tents of the blower kit. Con- tact your dealer if any damage is eviden t or par ts are missing. See fig. 35. 2. Attach the C ontrol Box to the Snapstat Brack et using two #8 x 1/2” sheet metal screws. As s ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 25

    25 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Blow er Oper ation The v ariable-speed blower will enhance heat circulation around the firebo x and out into the room. The blower is con trolled by a heat activated switch (snapstat) that will ONL Y function when the control switch is in A UT O setting. After the fir e has been burning for a time ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 26

    26 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer GF 100 D V I I / GF 200 DV I I Illustr ated P ar ts Break down / Firebo x Assembly Figure 39. A 1 2 3 4 4 4 4 4 4 5 6 7 8 10 11 12 13 33 24 28 27 25 26 24 29 30 31 20 21 22 17 16 15 14 23 19 22 22 18 63 47a 48 49 50 51 52 53 4 54 55 56 57 39 60 61 40 59 41 42 43 44 45 46 10 34 35 36 37 38 62 58 6 ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 27

    27 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Part Description Part Number 1. R ear Shroud, Matte Black .............. 22055592 R ear Shroud, Jøtul Iron ................... 22055585 2. Burner Co ntrol Switch ........................ 129123 3. Switch Bo x, Matte Black ................ 22092592 Switch Bo x, Jøtul Iron ..................... 2 ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 28

    28 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer GF 200 DV II Lillehammer Illustra ted Parts Breakdown / Cast Iron and Associa ted Hardw are GF 100 DV II Nordic QT 2 7 8 6 5 9 4 3 1 12 11 10 10 10 2 10 Figure 41. Figure 40 . 1 3 4 2 2 4 ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 29

    29 GF 100 D V II Nordic QT GF 200 D V II Lillehammer Cast Iron P ar ts List GF 200 D V I I Lillehammer 4. Screw , M6 x 12 T russ Head Phillips, ( 4) ........ 118045 Cast Iron Parts Matte Black Blue Black Ivory For est Green Jøtul Iron Jøtul Iron Enamel 1. T op Casting 10391092 10391027 10391029 10391032 10391085 10391046 2. Side Panel 10426992 10 ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 30

    30 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Optional Antique Brick P anel Kit 155815 Installation 1. Remove the T op Plate. Simply lift it up off of the stove body . It is not fastened. 2. GF 100 D V I I ONL Y : Remov e the Front Plate by lif ting straight up to disengage it from the sides. 3. Remov e the Glass Frame. Disengage the two tru ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 31

    31 GF 100 D V II Nordic QT GF 200 D V II Lillehammer 3. Access the lower controls. 4. Depress gas c ont rol knob sligh tly and turn clock - wise to “OFF” . Do not force. FOR Y OUR SAFETY , READ BEFORE LIGHTING . LIGHTING INSTRUCTIONS T O TURN OFF GAS T O THE APPLIANCE: LIGHTING INSTR UCTIONS WARNING: IF Y OU DO NO T FOLLO W THESE INSTRUCTIONS E ...

  • Jøtul GF 100 DV II, GF 200 DV II - page 32

    32 GF 100 DV II Nor dic QT GF 200 D V II Lillehammer Jøtul AS P . O . Box 1411 N-1602 Fr edrikstad Norway Jøtul North America 55 Hutcherson Drive Gorham, Maine 04038-2634 August 2005 138003 D This appliance must be installed in conformance with local and national building regula tions. Before beginning the installation, it is impor tant that the ...

Manufacturer Jøtul Category Electric Heater

Documents that we receive from a manufacturer of a Jøtul GF 100 DV II, GF 200 DV II can be divided into several groups. They are, among others:
- Jøtul technical drawings
- GF 100 DV II, GF 200 DV II manuals
- Jøtul product data sheets
- information booklets
- or energy labels Jøtul GF 100 DV II, GF 200 DV II
All of them are important, but the most important information from the point of view of use of the device are in the user manual Jøtul GF 100 DV II, GF 200 DV II.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Jøtul GF 100 DV II, GF 200 DV II, service manual, brief instructions and user manuals Jøtul GF 100 DV II, GF 200 DV II. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Jøtul GF 100 DV II, GF 200 DV II.

Similar manuals

A complete manual for the device Jøtul GF 100 DV II, GF 200 DV II, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Jøtul GF 100 DV II, GF 200 DV II by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Jøtul GF 100 DV II, GF 200 DV II.

A complete Jøtul manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Jøtul GF 100 DV II, GF 200 DV II - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Jøtul GF 100 DV II, GF 200 DV II, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Jøtul GF 100 DV II, GF 200 DV II, that we can find in the current document
3. Tips how to use the basic functions of the device Jøtul GF 100 DV II, GF 200 DV II - which should help us in our first steps of using Jøtul GF 100 DV II, GF 200 DV II
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Jøtul GF 100 DV II, GF 200 DV II
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Jøtul GF 100 DV II, GF 200 DV II in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Jøtul GF 100 DV II, GF 200 DV II?

Use the form below

If you did not solve your problem by using a manual Jøtul GF 100 DV II, GF 200 DV II, ask a question using the form below. If a user had a similar problem with Jøtul GF 100 DV II, GF 200 DV II it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)