    GAS MONITORS MODELS 2050-00 & 2050-10 MODELS 2060-00 & 2060-10 ...

  • Sierra Monitor Corporation 2060-10 - page 2

    Applicability & Effectivity Applicability & Effectivity Sierra Monitor Corporation 1991 T arob Court, Milpit as, CA 95035 (408) 262-661 1 (800) 727-4377 E-Mail: sierra@sierramonitor .com GAS MONITORS MODELS 2050-00 & 2050-10 MODELS 2060-00 & 2060-10 APPLICABILITY & EFFECTIVITY This manual provides instructions for the following ...

  • Sierra Monitor Corporation 2060-10 - page 3

    Table of Contents T ABLE OF CONTENTS SECTION P AGE 1.PRODUCT DESCRIPTION 1 1.1 Introduction 1 1.2 Application 1 1.3 Configuration 1 1.4 T emperature Range 2 1.5 Sensor 2 1.6 Remote Alarm 2 2. QUICK ST ART 3 2.1 Overview 3 2.2 Wiring 3 3. OPERA TION 4 3.1 Introduction 4 3.2 Alarms 4 3.3 Outputs 4 4. ALARM CALIBRA TION 5 4.1 Factory Alarm Calibration ...

  • Sierra Monitor Corporation 2060-10 - page 4

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 1.0 PRODUCT DESCRIPTION 1.1 Introduction The Model 2050 Ammonia and Model 2060 Refrigerant/ Halocarbon Gas Monitors are continuous duty , low cost stationary monitors for detection of high levels (50-500 PPM) of ammonia and halocarbon ("freons") refrigerant gases. See the specificatio ...

  • Sierra Monitor Corporation 2060-10 - page 5

    2050/2060 Gas Monitors (5/04) Page: Instruction Manual 1.4 T emperature Range The Model 2050 and 2060 have temperature compen- sated circuitry to provide stabilization in temperatures ranging from -4 o to 158 o F. However , for optimum operation the unit should be cali- brated at the normal temperature expected for the sensor location. 1.5 Semicond ...

  • Sierra Monitor Corporation 2060-10 - page 6

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 3 2.0 QUICK ST ART 2.1 Overview The Gas Sensor Module has been supplied factory calibrated and ready for immediate installation and operation. An installer familiar with installation and operation of gas detection products can use this section to begin immediate use of the monitor . 2.2 Wiring ...

  • Sierra Monitor Corporation 2060-10 - page 7

    2050/2060 Gas Monitors (5/04) Page: Instruction Manual 4 3.0 OPERA TION 3.1 Introduction Under normal conditions the gas sensor module does not require operator or technician intervention. The following are conditions under which the module re- quires attention: - Routine periodic calibration - Sensor replacement on a planned schedule or when a sen ...

  • Sierra Monitor Corporation 2060-10 - page 8

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 4.0 ALARM CALIBRA TION 4.1 Factory Alarm Calibration The module has been factory calibrated to alarm as indicated in T able 4.1 and as marked on the cali- bration label shipped with the module. Model Time Gas cc/min 2050-XX 100 sec. 100 ppm NH 3 50 2060-XX 60 sec. 500 ppm R1 1 5 0 500 ppm R12 5 ...

  • Sierra Monitor Corporation 2060-10 - page 9

    2050/2060 Gas Monitors (5/04) Page: Instruction Manual 4.4 Equipment Required The following tools and equipment will be required for calibration: - Jewelers Screwdriver - Calibration Gas - Calibration gas delivery system For accurate calibration use a gas mixture at the re- quired concentration mixed in an air balance, rather than with an inert gas ...

  • Sierra Monitor Corporation 2060-10 - page 10

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 5.0 SERVICE 5.1 Sensor Replacement The gas sensor needs replacement when: - It is no longer possible to obtain correct calibration - The failed sensor alarm (oscillating red/green LED) is on - The sensor output signal is noisy , causing incorrect gas alarms. T o replace the sensor: 1 . Confirm ...

  • Sierra Monitor Corporation 2060-10 - page 11

    2050/2060 Gas Monitors (5/04) Page: Instruction Manual 8 6.0 INST ALLA TION 6.1 Gas Sensor Module Locations The gas sensor module is a diffusion type sensor that should be located close to the anticipated source or destination of the gas hazard. For heavy gases such as H 2 S install the module within 24 inches of the ground. For lighter gases such ...

  • Sierra Monitor Corporation 2060-10 - page 12

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) Figure 6.1 Interconnect W iring T able 9 ...

  • Sierra Monitor Corporation 2060-10 - page 13

    2050/2060 Gas Monitors (5/04) Page: Instruction Manual T B2- 1 N C T B 2- 2 Comm o n T B 2- 3 N O No P o we r Op e n Sensor Fail Safe O pen Al ar m Open T B2- 1 N C T B 2- 2 Comm o n T B 2- 3 N O No P o we r Op e n Sensor Fail Saf e Open Al arm O pen Tabl e 6.3 Os c i lla ti n g Con nec t ed Connec ted Rel a y O p er at i n g States Rel a y O p er ...

  • Sierra Monitor Corporation 2060-10 - page 14

    Instruction Manual Page: 2050/2060 Gas Monitors (5/04) In all cases SMC’s responsibility and liability under this warranty shall be limited to the cost of the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty provision and com- pliance with such instruction shall be a condition of th ...

Manufacturer Sierra Monitor Corporation Category Carbon Monoxide Alarm

Documents that we receive from a manufacturer of a Sierra Monitor Corporation 2060-10 can be divided into several groups. They are, among others:
- Sierra Monitor Corporation technical drawings
- 2060-10 manuals
- Sierra Monitor Corporation product data sheets
- information booklets
- or energy labels Sierra Monitor Corporation 2060-10
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sierra Monitor Corporation 2060-10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sierra Monitor Corporation 2060-10, service manual, brief instructions and user manuals Sierra Monitor Corporation 2060-10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sierra Monitor Corporation 2060-10.

A complete manual for the device Sierra Monitor Corporation 2060-10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sierra Monitor Corporation 2060-10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sierra Monitor Corporation 2060-10.

A complete Sierra Monitor Corporation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sierra Monitor Corporation 2060-10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sierra Monitor Corporation 2060-10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sierra Monitor Corporation 2060-10, that we can find in the current document
3. Tips how to use the basic functions of the device Sierra Monitor Corporation 2060-10 - which should help us in our first steps of using Sierra Monitor Corporation 2060-10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sierra Monitor Corporation 2060-10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sierra Monitor Corporation 2060-10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sierra Monitor Corporation 2060-10?

Use the form below

If you did not solve your problem by using a manual Sierra Monitor Corporation 2060-10, ask a question using the form below. If a user had a similar problem with Sierra Monitor Corporation 2060-10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)