Manual Lindy CPU IP Access Switch Plus

64 pages 3.31 mb
Download

Go to site of 64

Summary
  • Lindy CPU IP Access Switch Plus - page 1

    C P U I P A c c e s s S w i t c h P l u s User Guide   L O C R E M V N C 1 00 L N K P W R IP A ccess Switch Plus ...

  • Lindy CPU IP Access Switch Plus - page 2

                1 Contents I ntroduction CPU IP Access Switch Plus features - front and rear .................. 4 What’ s in the box ................................................ ...

  • Lindy CPU IP Access Switch Plus - page 3

                2 F urther information T roubleshooting ........................................................................ 32 Getting assistance ................................ ...

  • Lindy CPU IP Access Switch Plus - page 4

                3 I ntroduction Thank you for choosing the CPU IP Access Switch Plus from LINDY . This intelligent product delivers straightforward setup, secur e operation and the ab ...

  • Lindy CPU IP Access Switch Plus - page 5

                4 CPU IP Access S witch Plus featur es - front and r ear Considering its capabilities, the CPU IP is supplied within a remarkably compact casing. Measuring just 198mm ...

  • Lindy CPU IP Access Switch Plus - page 6

                5 What ’ s in the box CPU IP Access Switch Plus Power supply and country- specic power lead Four Self-adhesive rubber feet What y ou may additionally need CD-ROM ...

  • Lindy CPU IP Access Switch Plus - page 7

                6 I nstallation M ounting The CPU IP offers thr ee main mounting methods: • Supplied four self-adhesive rubber feet • Optional single unit rack brackets • Option ...

  • Lindy CPU IP Access Switch Plus - page 8

                7 Connections Installation of the CPU IP involves a number of basic connections to some or all of the following items: • Host computer or KVM switch ð • Local key ...

  • Lindy CPU IP Access Switch Plus - page 9

                8 Local keyboar d, video monitor and mouse A locally connected keyboard, video monitor and mouse ar e required during the initial conguration. These are also useful ...

  • Lindy CPU IP Access Switch Plus - page 10

                9 M odem/ISDN por t The CPU IP provides a serial port specically for you to connect either a modem or ISDN terminal adapter . This can be used as a primary , second ...

  • Lindy CPU IP Access Switch Plus - page 11

                10 P o wer control port The CPU IP provides a serial port for connection to one or mor e optional power control units. This allows you to contr ol the mains power bein ...

  • Lindy CPU IP Access Switch Plus - page 12

                11 Conguration Initial conguration The initial conguration occurs as two distinct parts: Part 1 – Local conguration This part of the conguration takes ...

  • Lindy CPU IP Access Switch Plus - page 13

                12 T o perform the initial local conguration 3 If necessary , edit the Modem cong screen. I P Ac ce ss S wi t c h + Un it C o n fi g H o t Ke y s C t rl + A lt S ...

  • Lindy CPU IP Access Switch Plus - page 14

                13 Once the user name and password have been accepted, the scr een should now show the host comp uter scr een ( or , if none is co nnec ted, a bla nk im age). 6 T o vi ...

  • Lindy CPU IP Access Switch Plus - page 15

                14 Hot plugging and mouse r estoration It is strongly r ecommended that you switch off a host computer before attempting to connect it to the CPU IP . However , if thi ...

  • Lindy CPU IP Access Switch Plus - page 16

                15 Resetting the conguration The CPU IP asks for an unknown admin password This may occur if the CPU IP has been previously congur ed. If the existing admin pass ...

  • Lindy CPU IP Access Switch Plus - page 17

                16 P art 2 – Remote conguration The second part of the conguration requir es you to log into the CPU IP from a system via either a network connection or a dial ...

  • Lindy CPU IP Access Switch Plus - page 18

                17 N etworking issues Thanks to its robust security the CPU IP of fers you great exibility in how it integrates into an existing network structure. The CPU IP is de ...

  • Lindy CPU IP Access Switch Plus - page 19

                18 Addressing When the CPU IP is situated within the local network, you will need to give it an appropriate local IP addr ess and IP network mask. This is achieved mos ...

  • Lindy CPU IP Access Switch Plus - page 20

                19 Placing CPU IP alongside the r ewall CPU IP is built from the gr ound-up to be secure. It employs a sophisticated 128bit public/private key system that has been ...

  • Lindy CPU IP Access Switch Plus - page 21

                20 P ow er switching conguration Power switch conguration comprises two main steps: • Congure the COM2 serial port to the same speed as used by the power sw ...

  • Lindy CPU IP Access Switch Plus - page 22

                21 M a in t e na nc e R e se t C o nf ig u r at io n r e tu r n t o no rm a l o pe ra t i on . C o nf i g ur e Ne t w or k P u t op t i on s wi tc h 1 u p t o T o up g ...

  • Lindy CPU IP Access Switch Plus - page 23

                22 Operation Connecting to the CPU IP The CPU IP offers you thr ee ways to connect: • Local connection, • Remote connection by network link, • Remote connection ...

  • Lindy CPU IP Access Switch Plus - page 24

                23 Remote connections From a r emote system, you connect to the CPU IP using a viewer and a link. There ar e two types of viewer and two types of link, which can be us ...

  • Lindy CPU IP Access Switch Plus - page 25

                24 Remote connection by VNC viewer The VNC viewer is a compact application that runs on your remote system and allows you to view and use the CPU IP and its host compu ...

  • Lindy CPU IP Access Switch Plus - page 26

                25 U sing the viewer windo w The viewer window gives you the ability to view and control the CPU IP and its host computer(s). Its operation is almost identical regar d ...

  • Lindy CPU IP Access Switch Plus - page 27

                26 Host selection The Hosts button on the menu bar provides the quickest and most efcient way to switch between host computers. This is because the button is close ...

  • Lindy CPU IP Access Switch Plus - page 28

                27 Access mode - shar ed/private Up to ve users can be simultaneously logged-on (four remote users plus one local user) and during normal operation, all are able to ...

  • Lindy CPU IP Access Switch Plus - page 29

                28 Keyboard contr ol This option displays a keyboard contr ol dialog and is useful for sending keyboard combinations (to the host) that are needed r egularly or that a ...

  • Lindy CPU IP Access Switch Plus - page 30

                29 Video settings This dialog provides access to all of the key video settings that determine image quality and link performance. All settings can be individually subj ...

  • Lindy CPU IP Access Switch Plus - page 31

                30 If y ou need to enter a port number Usually , when you make a network connection to the CPU IP (either using the VNC viewer or a Web br owser) you simply enter the ...

  • Lindy CPU IP Access Switch Plus - page 32

                31 Viewer encryption settings The web browser viewers and VNC viewers (of level 4.0b5S or higher) of fer four encryption options. The resulting actions of certain opti ...

  • Lindy CPU IP Access Switch Plus - page 33

                32 F ur ther infor mation This chapter contains a variety of information, including the following: • T roubleshooting - see below • Getting assistance - see right ...

  • Lindy CPU IP Access Switch Plus - page 34

                33 Appendix 1 - Local conguration menus This section covers the control menus that ar e available when you are using the locally connected keyboard, video monitor a ...

  • Lindy CPU IP Access Switch Plus - page 35

                34 U nit conguration This page provides access to a selection of both basic and fundamental settings for the CPU IP . I P A cc es s S w it ch + U ni t Co n f ig H o ...

  • Lindy CPU IP Access Switch Plus - page 36

                35 N etwork conguration This page allows you to congure the various aspects of the IP port and its relationship with the local network. N e tw or k Co n f ig N e ...

  • Lindy CPU IP Access Switch Plus - page 37

                36 M odem conguration This page allows you to congure the COM1 serial port located at the rear of the CPU IP . M o de m Co nf i g A T ZH S0 =1 1 9 2. 16 8. 3 . 2 ...

  • Lindy CPU IP Access Switch Plus - page 38

                37 Reset conguration This option allows you to completely reset the CPU IP . R e se t Co nf i g D O Y OU W IS H TO C ON T I NU E? C a nc el R E SE T W A RN IN G: C ...

  • Lindy CPU IP Access Switch Plus - page 39

                38 Clear IP access control This option removes all entries fr om the IP access control feature within the CPU IP . What is IP access control? The IP access control fea ...

  • Lindy CPU IP Access Switch Plus - page 40

                39 There ar e ve tabbed pages of options: Colour/Encoding Auto select When ticked, this option will examine the speed of your connection to the CPU IP and apply the ...

  • Lindy CPU IP Access Switch Plus - page 41

                40 Inputs Send pointer events to server When un-ticked, the VNC viewer will not send mouse movement or click data to the CPU IP or host system. Send keyboard events to ...

  • Lindy CPU IP Access Switch Plus - page 42

                41 I dentities This feature helps your VNC viewer to conrm that a revisited CPU IP is genuine and not another device masquerading as a CPU IP . The list given will ...

  • Lindy CPU IP Access Switch Plus - page 43

                42 Appendix 3 - VNC viewer windo w options Click the VNC icon in the top left corner of the viewer window (or press F8) to display the window options: Standard window ...

  • Lindy CPU IP Access Switch Plus - page 44

                43 There is a single page of options: Encoding and colour lev el Auto select When ticked, this option will examine the speed of your connection to the CPU IP and apply ...

  • Lindy CPU IP Access Switch Plus - page 45

                44 Appendix 5 - R emote conguration menus This section covers the conguration menus that are available to r emote admin users using either the VNC viewer or the ...

  • Lindy CPU IP Access Switch Plus - page 46

                45 U ser accounts This section allows you to manage up to sixteen separate accounts. The rst of the sixteen accounts is the admin account and is the only account wi ...

  • Lindy CPU IP Access Switch Plus - page 47

                46 U nit conguration This page provides access to a selection of both basic and fundamental settings for the CPU IP . Many of the settings displayed here are also a ...

  • Lindy CPU IP Access Switch Plus - page 48

                47 Advanced unit conguration Click this button to display several advanced options that do not normally requir e alteration. Force VNC pr otocol 3.3 IMPORT ANT : Th ...

  • Lindy CPU IP Access Switch Plus - page 49

                48 N etwork conguration This page allows you to congure the various aspects of the IP port and its relationship with the local network. MAC address Media Access ...

  • Lindy CPU IP Access Switch Plus - page 50

                49 Setting IP access control The golden rule with this feature is ‘Include befor e you exclude’ or to put it another way ‘Arrange allowed addresses in the list b ...

  • Lindy CPU IP Access Switch Plus - page 51

                50 Serial port conguration This page provides all access to settings concerned with the two serial ports (modem and power control) that ar e situated at the rear of ...

  • Lindy CPU IP Access Switch Plus - page 52

                51 H ost conguration This page provides the opportunity to congur e various details for each of the host systems that may be connected to the CPU IP via one or m ...

  • Lindy CPU IP Access Switch Plus - page 53

                52 Logging and status This screen pr ovides various details about the user activity on the CPU IP . Date and time the event occurred User name Access method or remote ...

  • Lindy CPU IP Access Switch Plus - page 54

                53 Appendix 6 – A ddresses, masks and ports IP address, network masks and ports ar e all closely linked in the quest for one device to nd another across disparate ...

  • Lindy CPU IP Access Switch Plus - page 55

                54 N et masks - the binar y explanation T o really understand the operation of a net mask it is necessary to delve deeper into the life blood of computers – binary ; ...

  • Lindy CPU IP Access Switch Plus - page 56

                55 Calculating the mask for IP access control The IP access control function uses a standar d IP address and a net mask notation to specify both single locations and r ...

  • Lindy CPU IP Access Switch Plus - page 57

                56 LOCREM VNC 100 LNKPWR IP Access Switch Plus Internet W eb server P orts If you accept the analogy of IP addresses being rather like telephone numbers, then think of ...

  • Lindy CPU IP Access Switch Plus - page 58

                57 Appendix 7 – C able and connector specications RS232 serial mouse to PS/2 conv erter cable 5 1 CLK DCD NC NC NC 1 2 DA T RXD 2 5 TXD GND 3 4 GND Female 6 5 4 3 ...

  • Lindy CPU IP Access Switch Plus - page 59

                58 Appendix 8 – H otkey sequence codes These codes are used when dening hotkey switching sequences for host computers and allow you to include almost any of the s ...

  • Lindy CPU IP Access Switch Plus - page 60

                59 O t he r pr od uc t s in t h e CP U S w i t ch r an g e The following related LINDY CPU Switch items ar e available: • Matrix C PU Switch Dual Junior 2 u se r , 8 ...

  • Lindy CPU IP Access Switch Plus - page 61

                60 Radio F requency E nergy A Category 5 (or better) twisted pair cable must be used to connect the CPU IP units in order to maintain compliance with radio fr equency ...

  • Lindy CPU IP Access Switch Plus - page 62

                61 www .ctxd.com Documentation by: © 2004 LINDY Electronics Limited & LINDY Elektr onik GmbH All trademarks are acknowledged. Release 1.0c October 2004 Great Brit ...

  • Lindy CPU IP Access Switch Plus - page 63

                62 HT I ndex A Access control conguration 49 mask calculation 55 Access mode shared & private 27 Account creation for users 45 Address explanation 53 Addressing ...

  • Lindy CPU IP Access Switch Plus - page 64

                63 Mouse restoration 13,14 Mouse calibration 27 Mouse control 28 N Networking issues 17 Network conguration 35,48 Network port connecting 8 Net mask 21,35 explanati ...

Manufacturer Lindy Category Switch

Documents that we receive from a manufacturer of a Lindy CPU IP Access Switch Plus can be divided into several groups. They are, among others:
- Lindy technical drawings
- CPU IP Access Switch Plus manuals
- Lindy product data sheets
- information booklets
- or energy labels Lindy CPU IP Access Switch Plus
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lindy CPU IP Access Switch Plus.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lindy CPU IP Access Switch Plus, service manual, brief instructions and user manuals Lindy CPU IP Access Switch Plus. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lindy CPU IP Access Switch Plus.

Similar manuals

A complete manual for the device Lindy CPU IP Access Switch Plus, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lindy CPU IP Access Switch Plus by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lindy CPU IP Access Switch Plus.

A complete Lindy manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lindy CPU IP Access Switch Plus - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lindy CPU IP Access Switch Plus, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lindy CPU IP Access Switch Plus, that we can find in the current document
3. Tips how to use the basic functions of the device Lindy CPU IP Access Switch Plus - which should help us in our first steps of using Lindy CPU IP Access Switch Plus
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lindy CPU IP Access Switch Plus
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lindy CPU IP Access Switch Plus in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lindy CPU IP Access Switch Plus?

Use the form below

If you did not solve your problem by using a manual Lindy CPU IP Access Switch Plus, ask a question using the form below. If a user had a similar problem with Lindy CPU IP Access Switch Plus it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)