Manual Zephyr ATI-M90ASX

22 pages 2.06 mb
Download

Go to site of 22

Summary
  • Zephyr ATI-M90ASX - page 1

    ww w .zephyr online.com T ilt A TI-M90ASX A TI-M90ABX RANGE HOOD - Installation instructions ...

  • Zephyr ATI-M90ASX - page 2

    ww w .zephyr online.com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 23 CAMP ANA EXTRACT ORA - Manual de utilización ...Pag. 45 CAPP A ASPIRANTE - istruzioni per l’uso ...Pag . 67 - 2 - ...

  • Zephyr ATI-M90ASX - page 3

    C ontents SAFETY INSTRUCTIONS .................................................................................................. pag. 4 LIST OF MA TERIALS ........................................................................................................... pag. 7 DUCTING CALCULA TION SHEETS .................................................... ...

  • Zephyr ATI-M90ASX - page 4

    ww w .zephyr online.com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspectors use. INST ALLER : Please leave these Instructions with this unit for the owner . OWNER : Please retain these i ...

  • Zephyr ATI-M90ASX - page 5

    settings. B. Always turn hood ON when cooking at high heat or when  ambeing foods ( i.e. Crepes Suz ette, Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans frequently . Grease should not be allowed to accumulate on fan or  lter . D. Use proper pan size . Always use cookware appropriate f or the size of the sur face elem ...

  • Zephyr ATI-M90ASX - page 6

    ww w .zephyr online.com through the  ue (chimney) of fuel burning equipment to prevent back drafting . F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those published by the National F ire Pr otection Association (NFP A), and the American Society for Heating, Refrigeration and Air Conditioning Eng ineers ( ...

  • Zephyr ATI-M90ASX - page 7

    List of Materials Electrical Junction Box T op Cover F ront Panel Decorative Mesh Filt ers Cont rol Light Bulbs TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1/4" x 2-3/4" 6 - 7 - ...

  • Zephyr ATI-M90ASX - page 8

    ww w .zephyr online.com Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air movement, the total duct length should not exceed 100 equivalent f eet. - 8 - ...

  • Zephyr ATI-M90ASX - page 9

    Hood Speci cations front of hood side of hood top of hood - 9 - ...

  • Zephyr ATI-M90ASX - page 10

    ww w .zephyr online.com NO TE! T he device in this v ersion (with internal suction motor) is equipped for rear discharge of e xhaust air . How ever , if required, it is possible to ha ve the exhaust air discharged fr om the top. This can be acc omplished by following the steps indicated in the follo wing paragraphs; upon r eaching step 7, the motor ...

  • Zephyr ATI-M90ASX - page 11

    Installation - In ternal Blow er 6. Remove the 6” round metal knockout pla- te from the blow er plate by using a  at head screwdriv er . See. F ig.4 7. Remove the (10 ) scr ews securing the blo- wer plate to the blo wer housing and remo- ve blow er plate. See. F ig.5 (Note! If air is discharged from the top , do not rotate the plate; pr oceed ...

  • Zephyr ATI-M90ASX - page 12

    ww w .zephyr online.com Installation - In ternal Blow er 13. Secure Green/Y ellow ground wire connected to the cable to the provided capacit or to blower plate. (type A) F ig. 11 14. Attach the 6 pin male molex connector from blower wir e to the 6 pin female molex connector located inside the blower housing . See Fig .12 15. Install the blower and ...

  • Zephyr ATI-M90ASX - page 13

    Installation - External & In-Line Blow er Prepar ation NO TE! T he device in this v ersion (with external motor) is equipped for rear discharge of e xhaust air . How ever , if required, it is possible to ha ve the exhaust air discharged fr om the top. This can be acc omplished by carrying out the steps indicated in the follo w- ing paragraphs; ...

  • Zephyr ATI-M90ASX - page 14

    ww w .zephyr online.com Installation - External & In-Line Blow er Prepar ation 5. Close the front panel while holding it by its external sides until it shuts. 6. Remove the metal motor plat e by striking it with the aid of a slotted screw driver . Fi g. 4 7 . Remo ve the (10) screws securing the blo- wer plate to the blo wer housing and re- mov ...

  • Zephyr ATI-M90ASX - page 15

    Note : Carry out the power supplly con- nection in accordance with the national electric code, ANSI/NFP A 70-1999. Note1 : A cable lock (not included) may be required b y local codes. Please review lo- cal codes for mor e information. 12. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blo- wer housing. See F ig 11 Note2 ...

  • Zephyr ATI-M90ASX - page 16

    ww w .zephyr online.com W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, cra wl spaces, ceiling , attics or garages. All exhaust must be ducted to the outside, unless using the recir culating op - tion. Use single wall rigid Metal ductwork only . F asten all connections with sheet metal screws and tape all jo ...

  • Zephyr ATI-M90ASX - page 17

    Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking sur face. If a connecting duct work composed of two parts is used, the upper par t must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or ...

  • Zephyr ATI-M90ASX - page 18

    ww w .zephyr online.com W ARNING: In order to facilitate their c onnec tion, make sure that the pow er supply conduits are not obstructed by the hood . 3. When the hood has been adjusted tighten the screws t o secure the hood in place. 4. Once the adjustment has been completed ,  x the hood de nitely using another (2 type D) screws. NO TE: Sc ...

  • Zephyr ATI-M90ASX - page 19

    Installation - P o wer Supply C onnection GENERAL • Carefully r ead the following important information regarding installation safety and maintenance . Keep this information booklet accessible for further consultations. POWER SUPPL Y CONNECTION F or connection to the power supply ref er to the following: 1. Remove the pow er supply cover by undoi ...

  • Zephyr ATI-M90ASX - page 20

    ww w .zephyr online.com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior to c ook ing. It is recommended to leave the applianc e in operation for 5 minutes after cooking is completed in order to complet ely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of mai ...

  • Zephyr ATI-M90ASX - page 21

    List of P ar ts and Acc essories DESCRIPTION HOOD P ART# REPLACEMENT P ARTS Light Bulb GU5, 20W (each) A TI Z0B0031 OPTIONAL AC CESSORIES Recirculating Kit A TI ZRC-00HZ Replacement Charc oal Filters A T I Z0F-00AC Short Duc t Cover (8”-9” ceiling) A TI Z1C-00TI Long Duct Cov er (9”-10” c eiling) A TI Z1C-01TI T o order par ts, visit us onl ...

  • Zephyr ATI-M90ASX - page 22

    3LIK0505 ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ATI-M90ASX can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ATI-M90ASX manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ATI-M90ASX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ATI-M90ASX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ATI-M90ASX, service manual, brief instructions and user manuals Zephyr ATI-M90ASX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ATI-M90ASX.

Similar manuals

A complete manual for the device Zephyr ATI-M90ASX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ATI-M90ASX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ATI-M90ASX.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ATI-M90ASX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ATI-M90ASX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ATI-M90ASX, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ATI-M90ASX - which should help us in our first steps of using Zephyr ATI-M90ASX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ATI-M90ASX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ATI-M90ASX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ATI-M90ASX?

Use the form below

If you did not solve your problem by using a manual Zephyr ATI-M90ASX, ask a question using the form below. If a user had a similar problem with Zephyr ATI-M90ASX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)