    Model AD1202 MCS Coax Controller Installation and Operating Instructions This manual describes the installation and operating procedures for the AD1202 MCS Coax Pan/Tilt and Lens Controller. The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site. Each camera can be individually controlled ...

  • American Dynamics AD1202 - page 2

    The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished ...

  • American Dynamics AD1202 - page 3

    The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture. AMERICAN DYNAMICS CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMO ...

  • American Dynamics AD1202 - page 4

    ...

  • American Dynamics AD1202 - page 5

    CONTENTS Page DESCRIPTION................................................................................................. 1 FEA TURES ....................................................................................................... 1 INST ALLA TION .............................................................................................. ...

  • American Dynamics AD1202 - page 6

    ...

  • American Dynamics AD1202 - page 7

    DESCRIPTION The AD1202 MCS Coax Controller is a compact Pan/Tilt, Lens, Preset Scene, and Auxiliary controller for four color or monochrome cameras. The AD1202 provides coax control of four cameras via the video line connection to the camera site. Additionally, AD Manchester Control Code outputs are available for control of non-coax camera Receiver ...

  • American Dynamics AD1202 - page 8

    CONNECTIONS All connections to the AD1202 Coax Controller are made on the unit’s rear panel, illustrated in Figure 2. Typical AD1202 connections with other AD units are illustrated in the Typical System Connections section at the end of this manual. Camera Video Inputs The AD1202 provides four video input connections on the rear panel for video s ...

  • American Dynamics AD1202 - page 9

    EXTERNAL Connector A 24-pin connector on the rear panel, labeled EXTERNAL, provides pins for external alarm inputs and control signals. A mating 24-pin plug-in connector with flying leads is provided. EXTERNAL Connector Pinouts Pin Function Pin Function 1 Channel SEL 1 13 Alarm Input 3 2 Channel SEL 2 14 Alarm Input 4 3 Channel SEL 3 15 Alarm Out 4 ...

  • American Dynamics AD1202 - page 10

    EXTERNAL Connector (Continued) AD MANCHESTER CONTROL CODE OUTPUTS The EXTERNAL connector provides two sets of AD Manchester Control Code lines (Code 1 - pins 5 - 7, and Code 2 - pins 8 - 10) for output of camera control commands (camera pan/tilt/lens/preset/aux) to AD Manchester Control Code units, such as camera site Receivers. 1. Connect the Blac ...

  • American Dynamics AD1202 - page 11

    FRONT PANEL CONTROLS The following front panel controls are provided for operator control of a camera site (see Figure 5). The use of these controls is described in the SETUP and OPERATION sections of this manual, pages 6 through 9. Channel Select Group 1, 2, 3, and 4 - Selects either a camera (site) to control, a preset scene to set or call, or an ...

  • American Dynamics AD1202 - page 12

    SETUP Factory Reset The AD1202 can be reset to factory default settings which are as follows: • resets the programmed AD1202 camera inputs (see Camera Programming) to cameras 1 through 4, respectively, • cancels front panel programming block, if enabled (see Front Panel Controls, page 5), and • disables all presets To reset the AD1202 to fact ...

  • American Dynamics AD1202 - page 13

    To program a specific camera select button for a switcher camera number: 1. Press the front panel PGM button on the AD1202. The PGM LED illuminates steadily, and the Channel Select button 1 LED flashes repeatedly. 2. Press the desired AD1202 Channel Select button for the specific camera input to be programmed. The associated Channel Select LED flas ...

  • American Dynamics AD1202 - page 14

    If an input is set as unterminated, that input must be looped to a terminated video device using the lower BNC connector (see Looping Video Outputs, page 2). Coax Code Selection The AD1202 provides two different types of code output for coax control to a camera Receiver: Standard or Enhanced UTC code. The selected code is transmitted to the camera ...

  • American Dynamics AD1202 - page 15

    9 Calling a Preset Camera Scene A suitably equipped AD Receiver can store a maximum of 72 preset scenes. The AD1202 can call any of the first four preset scenes using the front panel PRESET buttons. See Preset Scene Programming, page 7, to program preset scenes. To call a preset scene: 1. Select the desired camera (manual or external selection). 2. ...

  • American Dynamics AD1202 - page 16

    ...

  • American Dynamics AD1202 - page 17

    Appendix ...

  • American Dynamics AD1202 - page 18

    BUILT-IN TEST The AD1202 has a built-in test procedure that provides a verification of AD1202 front panel controls. To operate the built-in test: 1. Remove power from the AD1202, and remove the cover from the unit. 2. Press the TEST button on the PCB while applying power to the unit. See Figure A-1 for location of the TEST button. Each of the front ...

  • American Dynamics AD1202 - page 19

    T ypical System Connections ...

  • American Dynamics AD1202 - page 20

    TYPICAL SYSTEM CONNECTIONS AD1202 with four AD1641U Coax Receivers and Alarms REMOTE ALARM CONTACT 3 REMOTE ALARM CONTACT 4 C-2 AD1202 LOOPING VIDEO OUPUTS, ALL INPUTS UNTERMINATED REMOTE ALARM CONTACT 2 REMOTE ALARM CONTACT 1 AD1641U COAX RECEIVER 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 LOCAL MONITOR AD1641U COAX RECEIVER AD ...

  • American Dynamics AD1202 - page 21

    TYPICAL SYSTEM CONNECTION AD1202 with two AD1641U Coax and two AD1641M Control Code Receivers CAMERA 4 CAMERA 3 AD1202 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 * 120-Ohm Termination W B C-3 ALL INPUTS TERMINATED IN 75 Ω LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER AD1641M RECEIVER W B S * AD1641M RECEIVER W B S ...

  • American Dynamics AD1202 - page 22

    TYPICAL SYSTEM CONNECTION AD1202 with two AD1240 Series P/Ts and two AD1641U Coax Receivers CAMERA 4 AD1202 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 W B C-4 ALL INPUTS TERMINATED IN 75 Ω LOCAL MONITOR AD1641U COAX RECEIVER AD1641U COAX RECEIVER NOTE: AD1641 Series Receivers shown for illustration. Any AD Receiver with Coax o ...

  • American Dynamics AD1202 - page 23

    C-5 TYPICAL SYSTEM CONNECTIONS Two AD1202 Controllers with AD1408A Switcher AD1408A AUX Connector: Pin 1 - Camera ID, bit 0 Pin 2 - Camera ID, bit 1 Pin 3 - Camera ID, bit 2 Pin 4 - Ground AD1408A AD1202 AD1202 SWITCHER MONITOR 1 2 3 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 ADDITIONAL COAX RECEIVERS AD1641U COAX RECEIVER AD164 ...

  • American Dynamics AD1202 - page 24

    ...

  • American Dynamics AD1202 - page 25

    Index ...

  • American Dynamics AD1202 - page 26

    ...

  • American Dynamics AD1202 - page 27

    AD Manchester Control Code Outputs . . . . . . . . . . . . . . . . 4 Alarm Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Arrow Buttons, Front Panel ...

  • American Dynamics AD1202 - page 28

    ...

  • American Dynamics AD1202 - page 29

    Problem Possible Causes Suggested Action Operating Problems Cannot program camera numbers or Programming Blocking feature enabled Check and enable front panel controls (page 5) preset scenes No AD1202 indicators illuminate No power to AD1202 Check AC power cord, connection, and source LEDabove select button 1 is Two or more buttons are pressed at P ...

  • American Dynamics AD1202 - page 30

    ...

  • American Dynamics AD1202 - page 31

    Declaration of Conformity Manufacturer: Sensormatic CCTV Systems Division Manufacturer’s Address: Sensormatic CCTV Systems Division Sensormatic CCTV Systems Division 1 Blue Hill Plaza 600 Bradley Hill Road Pearl River, New York, 10965 USA Blauvel t, NY 10913 USA Sensormatic Electronics Corporation Sensormatic Electronics Corporation (IRL) LTD Sta ...

  • American Dynamics AD1202 - page 32

    SPECIFICATIONS Electrical Ratings: AD1202: 120 VAC, 50/60 Hz, 9 W ADS1202X: 230 VAC, 50/60 Hz, 50 mA Video Signal: AD1202 - EIA RS-170/NTSC Video, 525 lines @ 60 Hz ADS1202X - CCIR/PAL Video, 625 lines @ 50 Hz Video Inputs: Four input BNC's, 1 Vp-p composite video, selectable termination for each input Four looping output BNC's, 75-ohm Vi ...

Manufacturer American Dynamics Category MCS Coax Controller

Documents that we receive from a manufacturer of a American Dynamics AD1202 can be divided into several groups. They are, among others:
- American Dynamics technical drawings
- AD1202 manuals
- American Dynamics product data sheets
- information booklets
- or energy labels American Dynamics AD1202
All of them are important, but the most important information from the point of view of use of the device are in the user manual American Dynamics AD1202.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals American Dynamics AD1202, service manual, brief instructions and user manuals American Dynamics AD1202. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product American Dynamics AD1202.

A complete manual for the device American Dynamics AD1202, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use American Dynamics AD1202 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of American Dynamics AD1202.

A complete American Dynamics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual American Dynamics AD1202 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the American Dynamics AD1202, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the American Dynamics AD1202, that we can find in the current document
3. Tips how to use the basic functions of the device American Dynamics AD1202 - which should help us in our first steps of using American Dynamics AD1202
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with American Dynamics AD1202
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of American Dynamics AD1202 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning American Dynamics AD1202?

Use the form below

If you did not solve your problem by using a manual American Dynamics AD1202, ask a question using the form below. If a user had a similar problem with American Dynamics AD1202 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)