    Operating and assembly instructions AH 600-190 Extractor hood 0 0 1 2 3 ...

  • Gaggenau AH 600-190 - page 2

    AH 600-190 1 Preface 1. Important notes Page 3-4 1.1 F or your safety Page 3 1.2 Operating for the first time Page 4 1.3 About use Page 4 2. Structure and operating principle Page 5-6 2.1 Structure of the appliance Page 5 2.2 Accessories/special accessories Page 5 2.3 Operating principle Page 6 3. Operation Page 7-8 3.1 Switching on and off Page 7 ...

  • Gaggenau AH 600-190 - page 3

    2 Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages : – effective extraction thanks to the so-called “Coanda effect” – low operating noise T o ensure that you will be able to use this appli - ance in all its diversity , read through the operating and assembly ...

  • Gaggenau AH 600-190 - page 4

    3 1. Important notes 1.1 F or your safety – Damaged appliances must not be operated. – The appliance must only be connected by an authorised specialist , paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – Connecting cables must not com ...

  • Gaggenau AH 600-190 - page 5

    1.2 Operating for the first time Before operating the appliance for the first time, please pay attention to the following notes: – The appliance must be installed and connected by a specialist before it is operated for the first time. – The rating plate for this appliance is included with the instructions on a separate sheet. Store the rating p ...

  • Gaggenau AH 600-190 - page 6

    5 2. Structure and operating principle 2.1 Structure of the appliance 2.2 Accessories/special accessories Y ou can order the following special accessories: – Activated charcoal filter: KF 600-090 – Back draught flap RK 040-150: Back draught flap for insertion in the extractor ’s blow-out opening – Flexible aluminium pipe AR 040-150: DN 150 ...

  • Gaggenau AH 600-190 - page 7

    2.3 Operating principle This extractor hood swiftly and silently extracts all odours produced while cooking. Y ou can set different intensity levels depending on the intensity of odours. The exhaust air first passes through the integrated grease filter . The grease filter intercepts and traps the grease and odour particles in the air . In the exhau ...

  • Gaggenau AH 600-190 - page 8

    3.1 Switching on and off Switching on – T urn the “V entilation level” control knob to the ventilation level you require (Fig. 7). – The set level is displayed. Switching off – T urn the “V entilation level” control knob to the 0 position (Fig. 8). – The set level 0 is displayed for a few seconds. Note: The light can be switched on ...

  • Gaggenau AH 600-190 - page 9

    8 3.2 Special functions Intensive level Y ou should select the intensive level when browning and frying in an open pan. Switching on: (Fig. 10) – T urn the control knob to a ventilation level (1-3). – Press the intensive level key . The intensive level symbol appears on the display . The previously selected ventilation level flashes on the disp ...

  • Gaggenau AH 600-190 - page 10

    Cleaning the grease filters: The (Grease filter saturation) symbol flashes on the display after an operating time of 30 hours. Flashing of this symbol signals to you that the grease filters have to be cleaned. The grease filters can be cleaned at any time, even if the (Grease filter saturation) symbol does not flash. The metal filters can be remove ...

  • Gaggenau AH 600-190 - page 11

    Air recirculation If, when purchasing the extractor hood, you have decided in favour of the air recirculation mode, the activated charcoal filter KF 600-090 must be replaced after a certain amount of hood operation. Note: The activated charcoal filter is not included in the scope of delivery of the hood. Activated charcoal filters do not contain an ...

  • Gaggenau AH 600-190 - page 12

    11 First disconnect the appliance from the mains before carrying out any repairs . In the event of malfunctions , first of all check the household fuses. If the power supply is in proper working order , but the appliance is nevertheless not functioning, then please contact your specialist dealer or your responsible Gaggenau after -sales service. Sp ...

  • Gaggenau AH 600-190 - page 13

    12 6.1 T echnical data W eight: 28 kg Dimensions: 898 x 520 mm Electrical connection Pay attention to the rating plate data. The mains connecting cable must at least correspond to the type H 05 VV -F G 0,75. When replacing the mains cable, you must dismantle the tubular connection piece (undo 2 screws). The appliance must only be connected by an au ...

  • Gaggenau AH 600-190 - page 14

    Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the pipes are no ...

  • Gaggenau AH 600-190 - page 15

    Proceed as follows: Exhaust air operation: – From the bottom edge of the hood, mark a center line on the wall. – With the aid of the drilling template, mark the positions of the screws on the wall. Mark the contour of the hook-in area. This will make it easier to hook in the hood (Fig. 18). – Pay attention to the minimum clearance of 600 mm f ...

  • Gaggenau AH 600-190 - page 16

    – Secure the hood to the wall using the 4 screws b with shims c (Fig. 20). – Establish the pipe connection. – Establish the electrical connection. – Extract the protective file from the chimney paneling. Note: A void damaging the sensitive stainless steel surfaces. – Join the chimney shoe with the chimney base using the 6 screws (3.5 x 9. ...

  • Gaggenau AH 600-190 - page 17

    Recirculation air operation – From the bottom edge of the hood, mark a center line on the wall. – With the aid of the drilling template, mark the positions of the screws on the wall. Mark the contour of the hook-in area. This will make it easier to hook in the hood (Fig. 23). – Pay attention to the minimum clearance of 600 mm for electric coo ...

  • Gaggenau AH 600-190 - page 18

    – Screw together the air guidance housing and screw it onto the two retaining brackets (Fig. 25). – Establish the pipe connection between the air connection piece and the air guidance housing. – Establish the electrical connection. – Stick the included sealing strips (8 strips) around the air slots on the top chimney paneling. – Remove th ...

  • Gaggenau AH 600-190 - page 19

    GAGGENAU HAUSGERÄTE GMBH P.O. BOX 12 60 · D-76568 GAGGENAU , GERMANY Y (0 72 25) 9 67- 0 · FAX (0 72 25) 9 67-190 Y (0 1 8 0 1) 1 1 22 1 1 (KUNDENDIENST) · Y (0 1 8 0 1) 33 53 04 (ERSATZTEILE) www.gaggenau.com GAGGENAU HAUSGERÄTE GMBH P.O. BOX 10 02 50 · D - 80076 MÜNCHEN Y (0 89) 45 90-01 FAX (0 89) 45 90-23 47 ...

Manufacturer Gaggenau Category Ventilation Hood

Documents that we receive from a manufacturer of a Gaggenau AH 600-190 can be divided into several groups. They are, among others:
- Gaggenau technical drawings
- AH 600-190 manuals
- Gaggenau product data sheets
- information booklets
- or energy labels Gaggenau AH 600-190
All of them are important, but the most important information from the point of view of use of the device are in the user manual Gaggenau AH 600-190.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Gaggenau AH 600-190, service manual, brief instructions and user manuals Gaggenau AH 600-190. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Gaggenau AH 600-190.

A complete manual for the device Gaggenau AH 600-190, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Gaggenau AH 600-190 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Gaggenau AH 600-190.

A complete Gaggenau manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Gaggenau AH 600-190 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Gaggenau AH 600-190, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Gaggenau AH 600-190, that we can find in the current document
3. Tips how to use the basic functions of the device Gaggenau AH 600-190 - which should help us in our first steps of using Gaggenau AH 600-190
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Gaggenau AH 600-190
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Gaggenau AH 600-190 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Gaggenau AH 600-190?

Use the form below

If you did not solve your problem by using a manual Gaggenau AH 600-190, ask a question using the form below. If a user had a similar problem with Gaggenau AH 600-190 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)