Manual Metrologic IS4225 Scanner

36 pages 2.15 mb
Download

Go to site of 36

Summary
  • Metrologic IS4225 Scanner - page 1

    METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove ® Laser Bar Code Scanner Inst allation and User ’ s Guide 00-02258B_Front_Cover.qxd 5/30/2007 3:43 PM Page 1 ...

  • Metrologic IS4225 Scanner - page 2

    Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior w ritten consent, except by review er, w ho may quote brief passages in a review, or provided for in the Copy right Act of 1976. Trademarks Metrologic is a registered tradema ...

  • Metrologic IS4225 Scanner - page 3

    ii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and Acce ssories ..................................................................................... 1 Scanner Insta llation ..................................................................... ...

  • Metrologic IS4225 Scanner - page 4

    ...

  • Metrologic IS4225 Scanner - page 5

    1 I NTRODUCTION The IS4225 ScanGlove ® is a fully automatic single-line laser barcode scanner. The ScanGlove is designed to be used as a “hands-free” wearable scanner or a stationary desktop scanner. Every ScanGlove is equipped w ith ScanQuest ® , a patented activation technology that allows the scanner to read bar codes automatically as the ...

  • Metrologic IS4225 Scanner - page 6

    2 S CANNER I NSTALLATION 1. Turn off power to the host system. 2. Connect the communication cable to the proper port on the host device. 3. Turn on power to the host system. When the IS4225 first receives power , the red LED w ill flash, the green LED will flash, and t hen the scanner w ill beep once. See power source caution stat ement on page 10 ...

  • Metrologic IS4225 Scanner - page 7

    3 S CANNER C ONFIGURATION TO THE H OST S YSTEM The IS4225 is shipped from the factory pre-configured to a set of default parameters. It may be necessary to c hange the default parameters to match the host system’s requirements or to enable additional scanner functions. For a list of possible parameter settings, refer to the Default Settings secti ...

  • Metrologic IS4225 Scanner - page 8

    4 P ARTS OF THE S CANNER Figure 1. Scanner Parts Item No. Description  Green LED When a bar code is read successfully, the green LED will flash.  Red LED When the red LED is illuminat ed, the laser is on.  Red Output Window (Laser A perture)  Infrared Sensor (IR) If a specified time has elapsed without any scanning, the unit will enter ...

  • Metrologic IS4225 Scanner - page 9

    5 V ISUAL I NDICATORS There is a red and a green LED located on the top of the scanner. When the scanner is on, the flashing or constant, illumination of the LEDs indicates the status of the curr ent scan and the scanner. No Red LED Illumination of the LEDs will not occur if the scanner has remained dormant for a specif ied time and the scanner is ...

  • Metrologic IS4225 Scanner - page 10

    6 S IGNAUX O PTIQUES Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous inform ent sur l'état de palpage et de scanner. Ni la diode rouge, ni la diode v erte n'est allumée I l existe deux raisons possible ...

  • Metrologic IS4225 Scanner - page 11

    7 O PTISCHE A NZEIGEN Auf der Oberseite des Scanners befinden sich eine rote und eine grüne Leuchtdiodenanzeige. Ist der Scanner eingeschaltet, so geben Ihnen die blinkenden oder feststehenden Leuchtdiodenanz eigen Aufschluß über den Abtast und Scannerstatus. Weder rote oder noch grüne Leuchtanzeige Es gibt zwei mögliche Gründe, w eshalb die ...

  • Metrologic IS4225 Scanner - page 12

    8 S EGNALI O TTICI Sulla parte superiore dello scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando lo scanner è inserito, i diodi luminosi, che possono o essere accesi in continuazione o lampeggiare, Vi informano sullo stato della scansione e dell’apparecchio. Né il diodo luminoso rosso né quello v erde sono accesi Vi sono due ...

  • Metrologic IS4225 Scanner - page 13

    9 A UDIBLE I NDICATORS The scanner provides sounds to signal certain conditions. To change the volume (four settings are available) or turn the beeper off, refer to Scanner Operation: Beeper Options in the MetroSelect Single-Line Configuration Guide ( MLPN 00- 02544). One Beep When the scanner first receives power, the red LED w ill flash, followed ...

  • Metrologic IS4225 Scanner - page 14

    10 L ABELS Each IS4225 has a serial number label and a laser class label on the bottom of the unit. These labels provide important information like; date and location of manufacture, model number, serial number, caution statements and laser class. There is also text molded into the top of the case near the window that says, “AVOID EXPOSURE - lase ...

  • Metrologic IS4225 Scanner - page 15

    11 M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window w ill need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently w ipe the output window . ...

  • Metrologic IS4225 Scanner - page 16

    12 I NFRARED (IR) O BJECT S ENSOR An infrared (IR) device located behind t he window initiates the scanning process. The IR sensor is active as long as power is applied to the unit. When the IR sensor detects an object, the green LED w ill flash. When the laser decodes a bar code, the scanner transmits the data to the host system and emits a beep t ...

  • Metrologic IS4225 Scanner - page 17

    13 Scan Field The depth of field for the scanner is 12.7 mm to 203 mm (.5" to 8") from the face of the output window for .33 mm (13 mil) Bar Codes. Figure 3. Scan Field for .33 mm (13 mil) Bar Codes Specifications are subjec t to change without notice. ...

  • Metrologic IS4225 Scanner - page 18

    14 S PECIFICATIONS IS4225 S PECIFICATIONS O PERATIONAL Light Source: 650 nm ± 10nm VLD Depth of Field: 12.7 mm to 203 mm (.5" to 8") for .33 mm (13 mil) bar code Width of Scan Field: 28.6 mm (1.125”) @ face; 102 mm (4”) @ 76.2 mm (3”) Scan Speed: 52 scans lines per second Scan Pattern: Single scan line Min Bar Width: 0.173 mm (6.8 ...

  • Metrologic IS4225 Scanner - page 19

    15 D EFAULT S ETTINGS Many functions of the scanner can be "configured", that is enabled or disabled. The scanner is shipped from the factory c onfigured to a set of default conditions. All factory default parameters have an asteri sk ( * ) in the default column of the charts on the following pages . If an asteri sk is not in the default ...

  • Metrologic IS4225 Scanner - page 20

    16 D EFAULT S ETTINGS P ARAM E T ER D EFAULT RS232 L IGHT P EN K EYBOARD W EDGE USB ACK/NAK  XON/XOFF *  No Intercharacter Delay    1 Millisecond Intercharacter Delay    5 Millisecond Intercharacter Delay   10 Millisecond Intercharacter Delay  25 Millisecond Intercharacter Delay   100 Millisecond Intercharacte ...

  • Metrologic IS4225 Scanner - page 21

    17 D EFAULT S ETTINGS P ARAM E T ER D EFAULT RS232 L IGHT P EN K EYBOARD W EDGE USB RSS Limited ID “]e0” *     RSS Limited App ID “01” *     RSS Limited Check Digit *     Full ASCII code 39     Code 39 *     Codabar     Code 128 *     Code 93 *    ? ...

  • Metrologic IS4225 Scanner - page 22

    18 D EFAULT S ETTINGS P ARAM E T ER D EFAULT RS232 L IGHT P EN K EYBOARD W EDGE USB Mod 43 Check Digit Code 39     Transmit Mod 43 Check Digit Code 39 *     Transmit Start/Stop Code 39     CLSI Editing (Enable)     ITF Check Digit     Transmit MOD 10 ITF Check Digit     I 2 of ...

  • Metrologic IS4225 Scanner - page 23

    19 D EFAULT S ETTINGS P ARAM E T ER D EFAULT RS232 L IGHT P EN K EYBOARD W EDGE USB BIO DATA Mode   Golden Bountiful Formatting   Intermec Polling Mode D (limited function)   Enable Sineko Mode   Enable Caps Lock Mode (for MI951 keyboard wedge)   Enable French Wyse 120 PC Term   Rochford Tompson Mode    ...

  • Metrologic IS4225 Scanner - page 24

    20 D EFAULT S ETTINGS P ARAM E T ER D EFAULT RS232 L IGHT P EN K EYBOARD W EDGE USB Alt Mode  Auto Detection or Caps Lock  User-Defined Caps Lock  F0H Break Code Transmission *  800 Microsecond Delay-Enter Scan Code *  15 Millisecond Delay-Enter Scan Code  7-5 Millisecond Delay-Enter Scan Code  ...

  • Metrologic IS4225 Scanner - page 25

    21 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 26. S YMPTOMS P OSSIBLE C AUS E ( S ) S OLUTION No LEDs, beep and there is no visible laser No Power is being supplied to the scanner Make sure the cabl ...

  • Metrologic IS4225 Scanner - page 26

    22 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 2: IEC 60825-1:1993+A1:1997+A2:2001 EN 60825-1:1994+A2:2001+A1:2002 Caution Use of controls or adjustments or performanc e of procedures other than those specified herein may result in hazardous laser light exposure. U nder no circumstances should the customer ...

  • Metrologic IS4225 Scanner - page 27

    23 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class A Dev ices The fo llowing is applicable when the scanner cable is g reater in length ...

  • Metrologic IS4225 Scanner - page 28

    24 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliqu ...

  • Metrologic IS4225 Scanner - page 29

    25 P ATENTS This METROLOGI C product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No. 5,260, 553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,627,359; 5,661,292; 5,742,043; 5,756,982; 5,777,315; 5,789,730; 5,789,731; 5,825,012; 5,874,721; 5,886,337; 5,925,870; 5,925 ...

  • Metrologic IS4225 Scanner - page 30

    26 L IMITED W ARRANTY The IS4225 ScanGlov e ® scanners are manufactured by Metrologic at its B lackwood, New Jersey, U.S.A. facility . The IS4225 scanners have a t wo (2) y ear limited warranty from the date of manufact ure. Metrologic w arrants and represents that all IS 4225 scanners are free of all defects in material, workmanship and design, a ...

  • Metrologic IS4225 Scanner - page 31

    27 I NDEX A applicatio n ..................................... 1 audible ....................................... 5–9 autodiscrimi nates ......................... 14 B bar code .............. 4, 5–9, 11, 12, 21 beep ........................ 5–9, 14, 15, 21 C cable .................................... 1, 4, 14 caution .......................... ...

  • Metrologic IS4225 Scanner - page 32

    28 I NDEX R razzberry t one ......................... 9, 15 red LED ................................. 4, 5–9 rights ............................................ 25 roll, pitch, yaw.............................. 14 RS232 ............................. 14, 15–20 S safety ..................................... 22, 24 scan fiel d .................... ...

  • Metrologic IS4225 Scanner - page 33

    ...

  • Metrologic IS4225 Scanner - page 34

    ...

  • Metrologic IS4225 Scanner - page 35

    ...

  • Metrologic IS4225 Scanner - page 36

    May 2007 Printed in the USA 00 - 02258 C ...

Manufacturer Metrologic Category Scanner

Documents that we receive from a manufacturer of a Metrologic IS4225 Scanner can be divided into several groups. They are, among others:
- Metrologic technical drawings
- IS4225 Scanner manuals
- Metrologic product data sheets
- information booklets
- or energy labels Metrologic IS4225 Scanner
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic IS4225 Scanner.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic IS4225 Scanner, service manual, brief instructions and user manuals Metrologic IS4225 Scanner. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic IS4225 Scanner.

A complete manual for the device Metrologic IS4225 Scanner, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic IS4225 Scanner by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic IS4225 Scanner.

A complete Metrologic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic IS4225 Scanner - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic IS4225 Scanner, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic IS4225 Scanner, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic IS4225 Scanner - which should help us in our first steps of using Metrologic IS4225 Scanner
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic IS4225 Scanner
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic IS4225 Scanner in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic IS4225 Scanner?

Use the form below

If you did not solve your problem by using a manual Metrologic IS4225 Scanner, ask a question using the form below. If a user had a similar problem with Metrologic IS4225 Scanner it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)