  • Chicago Electric 97677 - page 1

    WET/DR Y V ACUUM 13 GAL. CAP ACITY Model 97677 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2008 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any a ...

  • Chicago Electric 97677 - page 2

    Page 2 SKU 97677 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s seria l numbe r in the back of the manual near the assembly diagram (or month and year of purchase if product ...

  • Chicago Electric 97677 - page 3

    Page 3 SKU 97677 For technical questions, please call 1-800-444-3353. outlets will reduce risk of electric shock. Avoid body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded. Do not expose power tools to rain c. or wet conditions. Water enteri ...

  • Chicago Electric 97677 - page 4

    Page 4 SKU 97677 For technical questions, please call 1-800-444-3353. power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools. Use the power tool and its f. accessories in accordance with these instructions and in the manner intended for this particular type of power ...

  • Chicago Electric 97677 - page 5

    Page 5 SKU 97677 For technical questions, please call 1-800-444-3353. activities, contains chemicals known [to the State of California] to cause cancer , birth defects or other reproductive harm. Some examples of these chemicals are:  ? ...

  • Chicago Electric 97677 - page 6

    Page 6 SKU 97677 For technical questions, please call 1-800-444-3353. of electric shock. (See 3-Prong Plug and Outlet.) The grounding prong in the plug is 2. connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never ...

  • Chicago Electric 97677 - page 7

    Page 7 SKU 97677 For technical questions, please call 1-800-444-3353. Protect the extension cords from 8. sharp objects, excessive heat, and damp or wet areas. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.1 – 3 ...

  • Chicago Electric 97677 - page 8

    Page 8 SKU 97677 For technical questions, please call 1-800-444-3353. Product Features See Figure A. 1. Suction Hose (50). a. T elescopic Suction T ube (82). b. Drain Hose (29). c. Upper Handle (18). d. Switch Knob (80). e. Upper Cover (9). f. Handle Pipe (19) g. Lower Handle (20). h. Intake Port (49). i. T ank (35). j. Wheel Cover (36). k. Wheel ( ...

  • Chicago Electric 97677 - page 9

    Page 9 SKU 97677 For technical questions, please call 1-800-444-3353. General Operation Instructions Dry V acuuming:  1.  Cover (9). ( ...

  • Chicago Electric 97677 - page 10

    Page 10 SKU 97677 For technical questions, please call 1-800-444-3353. Wet V acuuming:  1.  Cover (9). (See Figure A, and Assy . Diagr ...

  • Chicago Electric 97677 - page 11

    Page 1 1 SKU 97677 For technical questions, please call 1-800-444-3353. MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch Knob (80) of the Wet/Dry V acuum to its “OFF” position and unpl ...

  • Chicago Electric 97677 - page 12

    Page 12 SKU 97677 For technical questions, please call 1-800-444-3353. TROUBLESHOOTING Problem Possible Causes Likely Solutions V acuum will not start. No power at outlet. 1. Cord not connected. 2.  3. Check power at outlet. 1. Check that cord is plugged in ...

  • Chicago Electric 97677 - page 13

    Page 13 SKU 97677 For technical questions, please call 1-800-444-3353. Part # Description Qty . Part # Description Qty . 1 Decorative Cover 1 45 Caster (55mm) 2 2A Screw (ST4.2x16-F) 24 46 Base 1 3 Upper Cover Pressing Plate 2 47 Intake Bracket 1 4A Screw (ST3.5x16-F) 3 48 Intake Seal 1 5A Screw (ST2.9x8-F) 4 49 Intake Port 1 6 T ool Interface 1 50 ...

  • Chicago Electric 97677 - page 14

    Page 14 SKU 97677 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM REV 10c For the following parts, see page 8, Figure A: T elescopic Suction T ube (82) Wet & Dry Brush (83) Filter Cage (84) Foam Filter (85) Crevice Nozzle (86) Furniture Brush (87) Dust Bag (88) Suction Hose (50) A A A A A A A 37A A A A A ...

  • Chicago Electric 97677 - page 15

    Page 15 SKU 97677 For technical questions, please call 1-800-444-3353. LIMITED 1 YEAR / 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor , the belt ...

Manufacturer Chicago Electric Category Vacuum Cleaner

Documents that we receive from a manufacturer of a Chicago Electric 97677 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 97677 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 97677
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 97677.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 97677, service manual, brief instructions and user manuals Chicago Electric 97677. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 97677.

A complete manual for the device Chicago Electric 97677, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 97677 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 97677.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 97677 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 97677, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 97677, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 97677 - which should help us in our first steps of using Chicago Electric 97677
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 97677
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 97677 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 97677?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 97677, ask a question using the form below. If a user had a similar problem with Chicago Electric 97677 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)