Manual Omron HEM-SOLAR

39 pages 1.16 mb
Download

Go to site of 39

Summary
  • Omron HEM-SOLAR - page 1

    Solar Charging Manual Inflation Blood Pressure Monitor Model H EM-SOLAR • Instru ction M anual • Mod e d’empl oi • Gebrauch sanweisu ng • Manual e di is truzi oni • Manual de ins truccio nes • Gebruiks aanwi jzing • РУК ОВОДСТ ВО ПО ЭКСПЛУ А Т АЦИИ EN FR DE IT ES NL RU IM-HEM- 4500-SO LE-01-0 3/09 5322504 -1 ...

  • Omron HEM-SOLAR - page 2

    2 Content s Content s Before using t he unit Introdu ction ..... .... .... ....... .... .... ...... ..... ...... .... .... ....... .... .... ...... ..... ... 3 Import ant Saf ety In formati on ......... .... ...... .... .... ....... .... .... ...... ..... . 4 1. Ove rview ... ...... .... ..... ...... .... ...... ..... .... ...... .... ..... ...... ...

  • Omron HEM-SOLAR - page 3

    3 Introducti on EN Introduction Thank you for purchasing the O MRON HEM-S OLAR Upper Arm Blood Pressure Monitor . The OMRON HEM-SO LAR is a manual inflati on blood pressure monitor , operating on the oscillometric principle. It measures y our blood pressure and pulse rate simply and quickly . The OMRON HEM-SOLAR also recharges the bat tery using So ...

  • Omron HEM-SOLAR - page 4

    4 Importan t Safety Infor mation Important Safety Information Consult your doc tor during pregnancy , arrhythmia and art eriosclerosis. Please read this section carefully before using the uni t. Wa r n i n g : Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . (General Usage) • Always cons ...

  • Omron HEM-SOLAR - page 5

    5 Importa nt Safety Inform ation EN (Battery Usage for “AAA” batteries only) • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water . • Use only two “AAA” size batteries with this unit. Do not use ot her types of batteries. • Do not insert the batteries with their pol arities incorrectly a ...

  • Omron HEM-SOLAR - page 6

    6 Importan t Safety Infor mation • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the T echnical Dat a Section. • Read and follow the “ Correct Disposal of This Product” in the T echnical Data Section when dispos ing of the device and any used accessories or optional parts. HEM-4500-SOLE_ma ...

  • Omron HEM-SOLAR - page 7

    7 1.O verview EN 1. Overv iew Main unit A. Display B. I/O butto n (Power switc h) C. Air connect or cap for cuf f D. Air connect or for cuff E. Air connector f or inflation bulb F . Air connect or cap for inflat ion bulb G . AC Adapt er jack H. AC Adapter jac k cap I. Battery compart ment J. Sola r pane l A B I J D C E F G H HEM-4500-SOLE_mai n.boo ...

  • Omron HEM-SOLAR - page 8

    8 1.Over view Arm Cuff Inflation Bul b K. Arm cuf f (Mediu m cuff: ar m circumfer ence 22- 32 cm) L. Air T ube M. Air Plug N. Air Release Button O. Air T ube P . Air In flati on Bul b Q. Air Pl ug L K M O P N Q HEM-4500-SOLE_mai n.book Page 8 Tuesday, February 3, 2009 1:30 PM ...

  • Omron HEM-SOLAR - page 9

    9 1.O verview EN Display R. Systolic bloo d pressure S. Diastolic blood pre ssure T . Deflation symbo l U. Reinfl ation symbol V . Recha rgeable ba ttery ind icato r W . Heartb eat symbo l 1. Flashes during measurem ent 2. If flashing after measureme nt complete d, indicates b lood pressure out of recommend ed range* X. Pulse dis play Y . Battery l ...

  • Omron HEM-SOLAR - page 10

    10 1.Over view Pack age con tents (o ther s) Z. S tor age case AA. AC adapt er AB. Recha rgeable batt ery • Instructio n manual • G uar antee car d • Blood pressure pas s AA AB Z HEM-4500-SOLE_main.boo k Page 10 Tuesday, February 3, 2009 1:30 PM ...

  • Omron HEM-SOLAR - page 11

    11 2.P repar at ion EN 2. Preparation 2.1 Connecting/Replacing/Chargin g the Batteries T o make use of the Charging function, fi rst insert the Recha rgeable battery , attach the AC adapter , then charge up the battery . Connec ting the Re chargeab le Battery 1. T urn the main unit upside down. 2. Slide the battery cover in the direction of the arr ...

  • Omron HEM-SOLAR - page 12

    12 2.Prepa ration 4. Put the battery cover back in place. Slide the battery cover as indicated, until it clicks into place. 5. Insert the AC adapter plug into the AC adapter jack, then plug the AC ad apter into an electrical outlet. 6. After the battery is fully charged, remove the AC adapter plug from the monitor and close the AC adapter jack cap. ...

  • Omron HEM-SOLAR - page 13

    13 2.P repar at ion EN Recharg eable ba ttery Life & Charging The Rechargeable battery life can be confirmed in the bo ttom left corner of the display . Notes: • Charge the Rec hargeable battery as soon as the Rechargeab le battery indicator shows low . • When the Rechargeable battery indicat or goes out, the Rechargeable battery is empty o ...

  • Omron HEM-SOLAR - page 14

    14 2.Prepa ration How to Charg e the Battery When the Rechargeable battery indicator shows re maining power is low ( ) on the display , charge the battery . 1. Open the window and face the Solar panel to the sunlight near the window. 2. The orange LED is lit while the battery is being charged by solar power . Cautio n: • When charging the battery ...

  • Omron HEM-SOLAR - page 15

    15 2.P repar at ion EN Charging time and the Capacity of the Rechargeable battery T o charge the battery the following conditions are needed. Note: The capacity might change depending upon the weather situation. Weather Lu x T o fully charg e the batt ery 4 hours continu ous charge wit h a sout hern exposure Clear more tha n 80000l ux 35 ho urs con ...

  • Omron HEM-SOLAR - page 16

    16 2.Prepa ration Inst alling /Replacing the “AAA” size Batteries 1. T urn the main unit upside down. 2. Slide the battery cover in the direction of the arrow while pressing the ribbed part of t he cove r . 3. Install or replace two “AAA” size batteries so that the + (positive) an d - (negative) polarities match the po larities indicated on ...

  • Omron HEM-SOLAR - page 17

    17 3.Using t he Unit EN 3. Using t he U nit 3.1 How to Sit Correctly Wh en T aking a Measurement Correct posture du ring measurement is necess ary to get accurate results. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not t oo hot or too cold. • Avoid eating, d ...

  • Omron HEM-SOLAR - page 18

    18 3.Using the Unit Incorrect Posture These situations could lead to higher blood pressure values due to strain or the arm cuff being lower than the heart. If the arm cuff is at a lower position t han your heart use cushions etc., to adjust the height of your arm. • Arched back (leaning forwards) • Sitting cross-legged • Sitting on a sofa or ...

  • Omron HEM-SOLAR - page 19

    19 3.Using t he Unit EN 3.2 Applying t he Arm Cuff Notes: • Be sure to w rap the arm cuff correctly so t hat you get accurate res ults. • Measurements can be taken in light clothing. However , please remove thick clothes, such as sweaters, before taking a reading. • Y ou can take a measurement on either your lef t or right arm. The blood pres ...

  • Omron HEM-SOLAR - page 20

    20 3.Using the Unit 2. Put your left arm through the cuf f loop. Note: If the cuff i s not assembled, pass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Position the arm correctly . 4. When the c uff is positioned correct ly , close the fabric f as ...

  • Omron HEM-SOLAR - page 21

    21 3.Using t he Unit EN T aking measure ment s on the right arm Apply the cuff so that the air tube is at the side of your elbow . • Be ca refu l not to rest y our ar m on the air tube, or ot herwise restrict the flow of air to the cuff. • The cuff should be 1 to 2 cm above the elbow . 1 to 2 cm HEM-4500-SOLE_main.boo k Page 21 Tuesday, Februar ...

  • Omron HEM-SOLAR - page 22

    22 3.Using the Unit 3.3 T akin g a Reading 1. Preparation 1) Press the air release button to release any air in the arm cuf f. 2) Press the I /O button to turn the unit on. 3) All items in the dis play will be di splayed briefly . 4) The deflati on symbo l will fl ash. 5) Finally , the heartbeat symbol will appear and 0 is displayed. Note: If the d ...

  • Omron HEM-SOLAR - page 23

    23 3.Using t he Unit EN Notes: • If the reinflation symbol ( ) appears, squeeze the inflation bulb to re-inflate the arm cuff. • Do not inflate the arm cuff more than necessary . 3. Measurement starts. Measurement starts automatically after you s top inflating the arm cuff . Decreasing numbers appear on the display and the heartbeat symbol flas ...

  • Omron HEM-SOLAR - page 24

    24 3.Using the Unit 5. Check the measurement resu lt s. Note: Wait 2-3 minutes before taking another blood pressure measurement. Waiting bet ween readings allows the arteries to return to the condition prior to t aking the blood pressure measurement. 6. Undo the fast ener and remove the arm cu ff . 7. Press the I/O button to turn the unit off. Note ...

  • Omron HEM-SOLAR - page 25

    25 3.Using t he Unit EN Import an t: • If your sy stolic or diastolic pres sure is outside the standard range, the heartbeat symbol will blink when the measurement result is di splayed. Recent res earch suggests that the following values can be used as a gui de to high blood pressur e for measur ements taken at home. This criteria is for home blo ...

  • Omron HEM-SOLAR - page 26

    26 4.Quick Reference G uide 4. Quick R efere nce Guide Use this as a quick reference guide only . If you are using this device for the first time, please rea d carefully Chapter 3 of this Instruction Manual. T o help ensure a reliable reading, avoid eating, drinking alcohol, smoking, or exercising for at least 30 minutes before taking a measurement ...

  • Omron HEM-SOLAR - page 27

    27 5.Handlin g Error s and Pro blems EN 5. Ha ndling Errors and Problems 5.1 Error Messages Error D isplay Cause Remedy Cuff is und er inflat ed. Press air release button an d rest a rt th e me asur emen t wit h a higher inflation level. Carefu lly read s teps under se ction 3.3. Move ment durin g meas urement Repeat measurem ent. Rema in still and ...

  • Omron HEM-SOLAR - page 28

    28 5.Handlin g Error s and Pr oblems Pressure is too low. Press the inflation bu lb to inflate t he arm cuff un til the reinflatio n symbol goes out. Or, deflate the arm cuff and r epeat measurem ent after che cking that the h eartbeat symbol ( ) has been displayed . Refer to se ction 3.3. Error D isplay Cause Remedy HEM-4500-SOLE_main.boo k Page 2 ...

  • Omron HEM-SOLAR - page 29

    29 5.Handlin g Error s and Pro blems EN 5.2 T roubleshooting Prob lem Cau se Remed y The read ing is extremely l ow (or high). Arm cu ff not applied correctly . Apply the arm cuff correctly . Refer to sec tion 3.2 . Move ment o r t alkin g duri ng me asur emen t. Remain still and do not talk during measurem ent. Refer to sec tion 3.3 . Clothing is ...

  • Omron HEM-SOLAR - page 30

    30 5.Handlin g Error s and Pr oblems The unit loses power during mea surement . The batter ies are empty . Charge the batter y or re plac e the A AA si ze batterie s with ne w ones. Refer to sec tion 2.1 . Nothing h appens when you press the buttons . The batter ies are empty . Charge the batter y or re plac e the A AA si ze batterie s with ne w on ...

  • Omron HEM-SOLAR - page 31

    31 6.Maint enance an d Storag e EN 6. Maintenance and Stora ge T o protect your unit from damage, please obs erve the following: • Do not subject the main unit, cuf f and inflation bulb to extreme temperatures, humidity or moisture. • Do not fold the cuf f or tubing tightly . • Do not disassemble the unit. • Do not carry out repairs of any ...

  • Omron HEM-SOLAR - page 32

    32 6.Main tenance an d Storage Sto r a g e Keep the unit in its storage case when not in use. 1. Unplug the air tube from the ai r connector . 2. Gently fold the air tube into the arm cuff. Note: Do not bend the air tube excessively . 3. Place the arm cuff, inflation bulb and main unit in the storage case. Calibration a nd Service • The accuracy ...

  • Omron HEM-SOLAR - page 33

    33 7.Optional P arts EN 7. Option al Par t s Medium Arm Cuff Arm c ircumf ere nce 22 - 32 c m Large Arm Cuff Arm ci rcumf ere nce 32 - 42 c m Regular bulb Small cuff and bulb combination Arm c ircumf ere nce 17 - 22 cm Small Arm Cuff Arm circumferen ce 17 - 22 cm Rechargeabl e battery AC Adap ter “R” CM1-99 97578-9 CL1- 99967 60-3 4997 965-1 CS ...

  • Omron HEM-SOLAR - page 34

    34 8.Technica l Data 8. T ech nica l Dat a Product Description Manual Inflation B lood Pr essure Mon itor Model OMRON HEM-SOLAR (HEM-4500-SOLE) Display LCD Digital Display Measurement Method Oscillometric m ethod Measurement Range Pressure: 0 mmHg to 2 99 mmHg Pulse: 40 to 180/min. Accuracy Pressure: ± 3 mmHg Pulse: ± 5% of dis pla y re adin g In ...

  • Omron HEM-SOLAR - page 35

    35 8.Tec hnic al D ata EN Note: Subject t o technical m odification without prior n otice. • This device fulfils the previsions of EC directive 93 /42/EEC (Medical Device Directive). • This b lood pressu re monitor is design ed accordi ng to th e European S tandard EN1060, Non-invas ive sphygm omanome ters Part 1 : Gener al Require ments and Pa ...

  • Omron HEM-SOLAR - page 36

    36 8.Technica l Data This mark ing show n on th e product or its literatu re, indicate s that it should not be dispose d of, with o ther househ old waste s at the end of it s wor king lif e. T o preven t po ssi ble ha rm t o the e nvir onm ent or human h ealth fr om uncont rolled wa ste dispo sal, plea se separate th is from other typ es of wastes ...

  • Omron HEM-SOLAR - page 37

    37 9.Some Us eful Info rmation a bout Bloo d Pressur e EN 9. Some Useful Information about Blood Pressure What is Blood Pressu re? Blood pressure is a measure of t he force of blood flowing against the walls of the arteries. Arterial bl ood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle i ...

  • Omron HEM-SOLAR - page 38

    38 9.Some Useful Inf ormation a bout Bloo d Pressu re Classification of Blood Pressure by the World Heath Organization The World Health Organization (WHO) and the I nternational Society of Hypertension (ISH) developed the Blood Pressure Classification shown in this figure. This classification is based on the blood pressure values measured on people ...

  • Omron HEM-SOLAR - page 39

    39 9.Some Us eful Info rmation a bout Bloo d Pressur e EN Made in China Manufa ctur er OMRON HEAL THCARE CO., L T D. 24, Y amanouch i Y a manoshi ta-cho, Ukyo-ku , Kyoto, 615-008 4 Japan EU-r epre sent at ive OMRON HEAL THCARE EUROPE B.V . Kruisweg 577, 2 132 NA Hoo fddorp, T he Nether lands www.omron-healthca re.com Product ion Facilit y OMRON DAL ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron HEM-SOLAR can be divided into several groups. They are, among others:
- Omron technical drawings
- HEM-SOLAR manuals
- Omron product data sheets
- information booklets
- or energy labels Omron HEM-SOLAR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron HEM-SOLAR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron HEM-SOLAR, service manual, brief instructions and user manuals Omron HEM-SOLAR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron HEM-SOLAR.

A complete manual for the device Omron HEM-SOLAR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron HEM-SOLAR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron HEM-SOLAR.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron HEM-SOLAR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron HEM-SOLAR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron HEM-SOLAR, that we can find in the current document
3. Tips how to use the basic functions of the device Omron HEM-SOLAR - which should help us in our first steps of using Omron HEM-SOLAR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron HEM-SOLAR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron HEM-SOLAR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron HEM-SOLAR?

Use the form below

If you did not solve your problem by using a manual Omron HEM-SOLAR, ask a question using the form below. If a user had a similar problem with Omron HEM-SOLAR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)