    CPG Signals 2519 4 th Ave., P.O. Box 590, Moline, IL 61265 (800) 577-5758 / (309) 7 62-0731 / FAX (309) 762-8215 www.cpglifesafety.com CPG #2561255 Rev. A 0209 OPERATING MANUAL F IRE L ARM 2500 4 ZONE FIRE ALARM CONTROL PANEL ...

  • CPG CPG #2561255 - page 2

    CPG #2561255 F IRE L ARM 2500 Operating Manual Warranty CPG products are cove red by a limited warranty. See CPG’s warranty statement for more information (document #780-0762 ). ...

  • CPG CPG #2561255 - page 3

    D C B A 5 4 3 2 1 CPG #2561255 F IRE L ARM 2500 Operating Manual i Contents Contents 1 Overview ............................................................................... 1-1 1.1 General de scription ........................................................................................................ ........... 1-1 1.2 System featur es ... ...

  • CPG CPG #2561255 - page 4

    Contents CPG #2561255 F IRE L ARM 2500 Operating Manual ii 4.1.1 B1 St robe de vice ......................................................................................................... ............. 4-1 4.1.2 B1 Tem poral pa ttern ...................................................................................................... .......... ...

  • CPG CPG #2561255 - page 5

    E D C B 2 3 4 5 A 1 CPG #2561255 F IRE L ARM 2500 Operating Manual 1-1 1 Overview 1.1 General description The F IRE L ARM 2500 is an economical, conventional Fire Alarm Control Panel (FACP) with an e xtensive list of features. When installed with an appropriate battery backup supply, the FireLarm 2500 provides a complete fire alarm control system f ...

  • CPG CPG #2561255 - page 6

    Contents 1 CPG #2561255 F IRE L ARM 2500 Operating Manual 1-2 1.3 Specifications 1.3.1 Electrical specifications Primary (AC) power: Accessory (battery ) voltage 120VAC, 60 Hz, 1.5A max 24VDC; (charging current, 1.0A) Control Unit Requirements: Standby current Alarm current 110mA, 24VDC (not including auxiliary device s and modules)200mA, 24VDC ...

  • CPG CPG #2561255 - page 7

    E D C B 2 3 4 5 A 1 CPG #2561255 F IRE L ARM 2500 Operating Manual 1-3 • Size 18-½" x 14-¼" x 3-¾" • Finish Red. • Knockouts Combination ½" / ¾", 2 on each side, top and back. • Option Bezel trim for semi-flush mounting. 1.3.3 Service use: NFPA-72 • Local • Auxiliary (PPU) • Remote Station (PPU) • Centr ...

  • CPG CPG #2561255 - page 8

    Contents 1 CPG #2561255 F IRE L ARM 2500 Operating Manual 1-4 ...

  • CPG CPG #2561255 - page 9

    E D C B 3 4 5 A 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-1 2 Operation 2.1 Touchpad The touchpad provides user cont rol over the operation of the panel. It is readily accessible wh en the cover is open. Primary Function Primary Function Description  Resets all alarm circuit s if condition has been corre cted, removes power from init ia ...

  • CPG CPG #2561255 - page 10

    1 Contents 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-2 Secondary Function Secondary Function Description  (DELETE) Deletes the value at the cursor location whe n entering numeric val ues.  Num e r i c entry of 1.  Num e r i c entry of 2.  Num e r i c entry of 3.  Num e r i c entry of 4.  Num e r i c entry of 5.  Num e ...

  • CPG CPG #2561255 - page 11

    E D C B 3 4 5 A 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-3 2.3 Normal Standby Condition  The AC LED indicator is on with all other LED’s off.  The fire alarm system is constantly monito ring all circuits for alarm signals, faults and remote communication.  The panel optional LCD will display SYSTEM NORMAL when the system is ope ...

  • CPG CPG #2561255 - page 12

    1 Contents 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-4 2.5.3 NAC trouble / silence Notification appliance circuit: An increase of current to approximately 3.5mA when not in alarm or a decrease in current to approximately 1.5mA on the notification applianc e circuit will result in the following:  Operation of the bell trouble LED.  Op ...

  • CPG CPG #2561255 - page 13

    E D C B 3 4 5 A 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-5  With the exception of the loss of the AC-ON LED and transfe r of the auxiliary trouble relay cont acts, none of the trouble indicators will operate on loss of AC unless an ade quately charged battery i s connected to the proper terminals. 2.5.8 Auxiliary power output condition ...

  • CPG CPG #2561255 - page 14

    1 Contents 2 CPG #2561255 F IRE L ARM 2500 Operating Manual 2-6 ...

  • CPG CPG #2561255 - page 15

    E D C B 4 5 A 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-1 3 Installation 3.1 Safety message to installers People's lives depend on your safe installation of our products. It is important to read, understand, and fo llow all instructions ship ped with this product. The Facilities Engineer and the Safe ty Engineer should make selection ...

  • CPG CPG #2561255 - page 16

    Contents 1 2 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-2 3.2.5 Requirements for Centra l Station Fire Alarm Systems • Connect both phone lines t o the optional ZDACT and OPLCD and prog ram the telephone numbers for the reporting station. • Set the AC trouble report delay from 6 to 12 hours. 3.3 Installing the cabinet (and optional beze ...

  • CPG CPG #2561255 - page 17

    E D C B 4 5 A 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-3 3.4 Wiring Refer to Figures 3-5 through 3-7 for wirin g information. 1. Install all required conduits, external wiring. With the AC power turned off at the circuit breaker panel, connect the 120VAC hot (black), neutral (white) an d ground (green) wire to the panel as shown on the po ...

  • CPG CPG #2561255 - page 18

    Contents 1 2 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-4 Table 3-1: Current Requirements. Module/Device Standby mA Alarm mA 2500 with LCD display 2500 without LCD display CAM (Class A module) RALCD (Remote Annunciator) ZDACT (Digital Alarm Communicator) MBM module PAM-1 or PAM-2 Relay 170 105 0 95 30 30 15 310* 250 25 115 50 15 (250 moment ...

  • CPG CPG #2561255 - page 19

    E D C B 4 5 A 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-5 Figure 3-5. Four-wire detector connections ( St y le B, Class B cuircuit 4-WIRE DETECT ORS N.O . N.O. N.O . ZONE TERMINALS ALL CONT ACTS SHOWN IN NORMAL ST ANDBY CONDITION 290-0007 42 43 OUT IN OUT IN OUT IN EOL RESIST OR 5.1K OHM UL LISTED RELA Y SEE APPENDIX D FOR MODEL NUMBERS Fi ...

  • CPG CPG #2561255 - page 20

    Contents 1 2 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-6 PO WER RA TING 120V A C - 60 HZ (2) 12V , 6.5 AH min. batteries are required. Maximum battery charge current: 1A The battery set must be replaced every 4 years or earlier if capacity is excessiv ely reduced. The batteries should be checked at least twice a year , or more often if req ...

  • CPG CPG #2561255 - page 21

    E D C B 4 5 A 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-7 3.8 Notification Appliance Circuits Connections The control panel has two Style Y (Class B) notificati on appliance circuits whi ch can be upgraded to Style Z (class A) by the addition of a model CAM (Class A M odule). One module is required for each circuit that is to be upgraded. ...

  • CPG CPG #2561255 - page 22

    Contents 1 2 3 CPG #2561255 F IRE L ARM 2500 Operating Manual 3-8 ...

  • CPG CPG #2561255 - page 23

    E D C B 5 A 4 CPG #2561255 F IRE L ARM 2500 Operating Manual 4-1 4 Configurati on and Programming 4.1 Selecting connected devi ce options (DIP switches) A series of DIP switches are use d to configure dev ices connected to the fire alarm control panel. DIP switches are located in the lower rig ht corner of the panel. DIP Switch 9 Description of Dis ...

  • CPG CPG #2561255 - page 24

    1 2 3 Contents 4 CPG #2561255 F IRE L ARM 2500 Operating Manual 4-2 4.1.3 Reverse polarity circuits configuration This panel is equipped with two pola rity reversal-typ e outputs. This permits alarm and trouble signal s to be transmitted to one location and supervisory and tro uble signals to be transmitted to a secon d location. If trouble signals ...

  • CPG CPG #2561255 - page 25

    E D C B 5 A 4 CPG #2561255 F IRE L ARM 2500 Operating Manual Order of characters ←  key  key → ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? ~ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { l } ← → (space) 4-3 To enter the c ...

  • CPG CPG #2561255 - page 26

    1 2 3 Contents 4 CPG #2561255 F IRE L ARM 2500 Operating Manual Order of characters ←  key  key → ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? ~ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { l } ← → (space) 4-4 4.2.1 ZDACT ...

  • CPG CPG #2561255 - page 27

    E D C B 5 A 4 CPG #2561255 F IRE L ARM 2500 Operating Manual Order of characters ←  key  key → ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? ~ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { l } ← → (space) 4-5 AC DELAY (HR)? ...

  • CPG CPG #2561255 - page 28

    1 2 3 Contents 4 CPG #2561255 F IRE L ARM 2500 Operating Manual Order of characters ←  key  key → ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? ~ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { l } ← → (space) 4-6 4.2.2 Passw ...

  • CPG CPG #2561255 - page 29

    E D C B A 5 CPG #2561255 F IRE L ARM 2500 Operating Manual 5-1 5 Maintenance Most modern control units do not require perio dic adju stment or field repair other than re placement of a module or printed circuit board assem bly. Defective printed circuit board assemblies o r modules can best be serviced at the manufacturer’ s plant or at their aut ...

  • CPG CPG #2561255 - page 30

    1 2 3 4 Contents 5 CPG #2561255 F IRE L ARM 2500 Operating Manual 5-2 7. Press  . All audible and visual indicators on the panel and NAC out puts should operate. Restore AC power and ve rify panel is in normal standby conditio n. 8. Press  to enter auto reset mode. 9. Operate each initiating device on all zones. All audible and visual notific ...

  • CPG CPG #2561255 - page 31

    E D C B A CPG #2561255 F IRE L ARM 2500 Operating Manual A-1 Appendix A. Optional Accessories A.1 Remote Annunciator with Liqu id Crystal Display (2500-RALCD) Part # 2500-RALCD UL Listed: For use with the FireLarm 2500 Dimensions: 4 ½” W X 4 ½” H X 7/8” D (approximate) Weight: 5.5 OZ. Enclosure: Stainless steel plate. Mounts on st and ard d ...

  • CPG CPG #2561255 - page 32

    1 2 3 4 5 Contents A CPG #2561255 F IRE L ARM 2500 Operating Manual A-2 A.2 Zonal Digital Alarm Communicat or Transmitter (2500-ZDACT) UL LISTED: For use with the FireLarm 2500 Transient protected Power requirements: Input current Standby: 50mA Alarm current: 90mA max. Part # 2500-ZDACT: The ZDACT is used for off-premises monitoring of the fire ala ...

  • CPG CPG #2561255 - page 33

    E D C B A CPG #2561255 F IRE L ARM 2500 Operating Manual A-3 A.3 Style Z (Class A) Module for NAC circuits (CAM) UL LISTED: For use with the FireLarm 2500 Part No. 345-0234 TRANSIENT PROTECTED BUILT IN 5.1K END OF LINE RESISTOR POWER REQUIREMENTS IN ALARM: Approx. 25mA @ 24VDC from control panel notification appliance circuit The Model CAM Style Z ...

  • CPG CPG #2561255 - page 34

    1 2 3 4 5 Contents A CPG #2561255 F IRE L ARM 2500 Operating Manual A-4 A.4 Master Box Module (Model MBM) UL LISTED: For use with the FireLarm 2500 Part No. 345-0235 Power requirements: Standby: 30mA Max @24VDC Alarm: 300 mA Max @24VCD Master Box Coil Resistance: 14.5 ohms Trouble output: Positive 2.5 V goes low in trouble and SPDT contacts tra nsf ...

  • CPG CPG #2561255 - page 35

    E D C B A CPG #2561255 F IRE L ARM 2500 Operating Manual A-5 INSTALLATION Mount the snap track with the double-si ded tape provi ded and secure with two #6 sh eet metal screws. This module may be installed in a separate hou sing (HSI #327-0089) that is adjacent to and clo se- nippled to the fire alarm control panel. CAUTION: This module must be ins ...

  • CPG CPG #2561255 - page 36

    1 2 3 4 5 Contents A CPG #2561255 F IRE L ARM 2500 Operating Manual A-6 ...

  • CPG CPG #2561255 - page 37

    E D C B CPG #2561255 F IRE L ARM 2500 Operating Manual B-1 Appendix B. Smoke Detector Compatibility HARRINGTON SIGNA L (MAX. NO. OF DETECTORS PER ZONE IS 25) DET. MODEL IDENTIFIER BASE MODEL IDENTIFIER H511C S10A N/A H511CXT S11A N/A N/A ESL (MAX. NO. OF DETECTORS PER ZONE IS 25) DET. MODEL IDENTIFIER BASE MODEL IDENTIFIER 429C S10A N/A 429CRT S11A ...

  • CPG CPG #2561255 - page 38

    1 2 3 4 5 A Contents B CPG #2561255 F IRE L ARM 2500 Operating Manual B-2 ...

  • CPG CPG #2561255 - page 39

    E D C CPG #2561255 F IRE L ARM 2500 Operating Manual C-1 Appendix C. NAC Compatibility The following devices are comp atible with the FireLarm 2500 . CPG Signals 460 series sounders SPLF, SPAF, SPHP, SPHH, SPHX se ries Powertone® s peakers ASLP, ASHP, ASHH, ASHX series am plified Powertone® speakers MSLP, MSHP series mini speakers 450E series ele ...

  • CPG CPG #2561255 - page 40

    B 1 2 3 4 5 A Contents C CPG #2561255 F IRE L ARM 2500 Operating Manual C-2 4415, 4495 series AC chimes 4765, 4775 series DC chimes 3431, 3436, 4496, 4411, 4416 se ries AC bells 4461, 4464, 4466, 4761, 4764, 4766, 47 71, 4774, 4776 series DC bells ...

  • CPG CPG #2561255 - page 41

    E D CPG #2561255 F IRE L ARM 2500 Operating Manual D-1 Appendix D. Ordering Information Base Components Model No. Description Stock No. 2500-LCD 4 Zone Control Panel (red cabi net) – with LCD 2500-LCD 2500-LED 4 Zone Control Panel (r ed cabinet) – no LCD 2500-LED 2500-MAN FireLarm 2 500 Installation Instruction Manual 2500-MAN 12V6.5AH Battery, ...

  • CPG CPG #2561255 - page 42

    C B 1 2 3 4 5 A Contents D CPG #2561255 F IRE L ARM 2500 Operating Manual D-2 ...

  • CPG CPG #2561255 - page 43

    E CPG #2561255 F IRE L ARM 2500 Operating Manual E-1 Appendix E. Quick Reference Operating Instructions FireLarm 2500 Normal Standby Green AC indicator on. All other indicators off. Alarm Conditions Red zone indicator on . Audible/visual signaling indicator operating To Silence Alarm Do not silence ala rm until it has been determined that an emerge ...

  • CPG CPG #2561255 - page 44

    D C B 1 2 3 4 5 A Contents E CPG #2561255 F IRE L ARM 2500 Operating Manual E-2 ...

Manufacturer CPG Category Smoke Alarm

Documents that we receive from a manufacturer of a CPG CPG #2561255 can be divided into several groups. They are, among others:
- CPG technical drawings
- #2561255 manuals
- CPG product data sheets
- information booklets
- or energy labels CPG CPG #2561255
All of them are important, but the most important information from the point of view of use of the device are in the user manual CPG CPG #2561255.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals CPG CPG #2561255, service manual, brief instructions and user manuals CPG CPG #2561255. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product CPG CPG #2561255.

Similar manuals

A complete manual for the device CPG CPG #2561255, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use CPG CPG #2561255 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of CPG CPG #2561255.

A complete CPG manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual CPG CPG #2561255 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the CPG CPG #2561255, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the CPG CPG #2561255, that we can find in the current document
3. Tips how to use the basic functions of the device CPG CPG #2561255 - which should help us in our first steps of using CPG CPG #2561255
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with CPG CPG #2561255
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of CPG CPG #2561255 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning CPG CPG #2561255?

Use the form below

If you did not solve your problem by using a manual CPG CPG #2561255, ask a question using the form below. If a user had a similar problem with CPG CPG #2561255 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)