  • Hoshizaki 73180 - page 1

    Hoshizaki “A Superior Deg re e of Reliability” www .hoshizaki.com Models C-100BAF C-100BAF-DS C-100BAF-AD C-100BAF-ADDS Self-Contained Cubelet Hoshizaki America, Inc. Number: 73180 Issued: 10-6-2010 Revised: 1-9-2012 SE RV ICE MA NU AL ...

  • Hoshizaki 73180 - page 2

    2 W ARNING Only quali ed ser vice technicians should inst all and ser vice the icemak er . T o obtain the name and phone number of y our local Hoshizaki Cer ti ed Ser vice Repr esentativ e, visit www .hoshizaki.com. No ser vice should be under tak en until the technician has thor oughly r ead this Ser vice Manual. F ailure t o ser vice and ma ...

  • Hoshizaki 73180 - page 3

    3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 5 I. Specications ...................................................................................................................... 7 A. C-1 00BAF .................................................... ...

  • Hoshizaki 73180 - page 4

    4 D . Float S witch Check and Cleaning (auxiliary codes A -2 and later) ............................... 28 1 . Float Switch Chec k ................................................................................................. 28 2. Float Switch Cleaning ............................................................................................. ...

  • Hoshizaki 73180 - page 5

    5 Impor tant Safety Inf ormation Throughout this man ual, notices appear to bring y our at tention t o situations which could result in death, serious injur y , damage to the appliance , or damage to pr oper ty . W ARNING Indicates a hazar dous situation which could r esult in death or serious injury . NO TICE Indicates a sit uation which could res ...

  • Hoshizaki 73180 - page 6

    6 W ARNING, continued • This appliance is not intended f or use by per sons (including children) with r educed ph ysical, sensory , or ment al capabilities, or lac k of e xperience and knowledge, unless they ha ve been giv en super vision or instr uction concerning use of the appliance by a person r esponsible f or their safety . • Y oung child ...

  • Hoshizaki 73180 - page 7

    7 I. Specications A. C-1 0 0B AF 1 . A uxiliary Codes A-1 and Ear lier Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAGE 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A mbient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 ...

  • Hoshizaki 73180 - page 8

    8 A. C-1 0 0B AF , continued 2. Auxiliary Codes A-2 and Later Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAG E 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACIT Y 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A m bient W ATER T EMP. (°F) PER 24 HR. Tem p.(°F) 50 70 90 lb ...

  • Hoshizaki 73180 - page 9

    9 B. C-1 0 0B AF-DS 1 . A uxiliary Codes A-1 and Ear lier Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAGE 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A mbient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( k ...

  • Hoshizaki 73180 - page 10

    10 B. C-1 0 0B AF-DS, continued 2. Auxiliary Codes A-2 and Later Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAG E 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACIT Y 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A m bient W ATER T EMP. (°F) PER 24 HR. Tem p.(°F) 50 70 90 ...

  • Hoshizaki 73180 - page 11

    11 C. C-1 0 0B AF-AD 1 . A uxiliary Codes A-1 and Ear lier Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAGE 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A mbient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( ...

  • Hoshizaki 73180 - page 12

    12 C. C-1 0 0B AF-AD , continued 2. Auxiliary Codes A-2 and Later Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAG E 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACIT Y 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A m bient W ATER T EMP. (°F) PER 24 HR. Tem p.(°F) 50 70 9 ...

  • Hoshizaki 73180 - page 13

    13 D . C-1 0 0B AF-ADDS 1 . A uxiliary Codes A-1 and Ear lier Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAGE 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACITY 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A mbient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ...

  • Hoshizaki 73180 - page 14

    14 D . C-1 0 0B AF-ADDS, continued 2. Auxiliary Codes A-2 and Later Note: We r eser ve the right to mak e changes in specications and design without pr ior notice. AC SUPPLY VOLTAG E 115/60/1 AMPERAGE 4.0 A MINIMUM CIRCUIT AMPACIT Y 15 A MAXIMUM FUSE SIZE 15 A A PPROXIMATE ICE PRODUCTION A m bient W ATER T EMP. (°F) PER 24 HR. Tem p.(°F) 50 70 ...

  • Hoshizaki 73180 - page 15

    15 II. General Inf ormation A. Construction 1 . Icemaker R ear Float-Operat ed W ater V alve Air -Cooled Condenser and Condenser F an Motor F ront Contr ol Bo x W ater Reservoir Ev aporator Assembl y Upper Rear P anel Suction T emperature Saf et y Bin Contr ol Ther mostat F ig. 1 F ront P anel Louv er T op Panel P ower S witch Gear Motor P rotect o ...

  • Hoshizaki 73180 - page 16

    16 2. Icemaking Unit Sock et Head Cap Scre w Gear Motor Spline Coupling Housing and Lower Bearing O-Ring Mechanical Seal C ylinder A uger Extruding Head and Upper Bearing Cut ter (motionless) Insulation Sock et Head C ap Scre w with W asher He x Head Bolt with W asher F ig. 2 Ev aporator Flange ...

  • Hoshizaki 73180 - page 17

    17 B. Sequence of Operation 1 . A uxiliary Codes A-1 and Ear lier Af ter the po wer s witch is placed in the "ON" position, the steps in the sequence are as outlined below . a) F reeze Cy cle BCH, GM, FM, CR, and Comp ener gize. NOTICE! Some units contain a stic ker that states: "The bin control heater has been disconnect ed. DO NO T ...

  • Hoshizaki 73180 - page 18

    18 3. Shutdown 2. F reeze Cycle Bin F ull P ower S witch "ON" BC open BCH continues Comp de-energized FM de-energized GM de-energized WV de-energized BC closed BC closed LF/S closed UF/S closed BCH continues Comp energized FM energized GM energized WV de-energized BC closed UF/S open LF/S open FT starts (90 sec.) BCH continues Comp contin ...

  • Hoshizaki 73180 - page 19

    19 III. T echnical Infor mation A. W ater Cir cuit and Refr ig er ation Circuit 1 . A uxiliary Codes A-1 and Ear lier Drier Condenser F an Motor Condenser Compr essor Float-Operat ed Inlet W ater V alv e W ater Reservoir W ater Le vel Suction T emperature Saf et y Gear Motor Ev aporator Assembl y W ater Inlet W ater Supply F ig. 3a C apillar y T ub ...

  • Hoshizaki 73180 - page 20

    20 Drier Condenser F an Motor Condenser Compr essor Float S witch W ater Reservoir W ater Le vel Gear Motor Ev aporator Assembl y W ater Inlet W ater Supply C apillar y T ube Over ow Hoses Suction Discharge Inlet W ater V alv e 2. Auxiliary Codes A-2 and Later F ig. 3b ...

  • Hoshizaki 73180 - page 21

    21 B. W iring Diagram 1 . Icemaker a) Auxiliary Codes A-1 and Earlier (3W) (ext ernal protect or 2.4~3.0A) b) Auxiliary Codes A-2 and L ater C-1 00BAF Series (3W) (internal protect or) (ext ernal protect or) (90-second ll timer (low wat er safety)) WIRE COLOR CODE WIRE COLOR CODE (ext ernal protect or) (internal protect or) (ext ernal protect or ...

  • Hoshizaki 73180 - page 22

    22 (90-second ll timer (low wat er safety)) 2. Icemaker with Optional Dr ain Pump HS-0248 Optional Drain P ump HS-0248 Safety Shutdown: If the water le vel in the dr ain pump reservoir rises high enough to close the dr ain pump upper  oat s witch, the drain pump saf ety interrupts power t o the icemaker . When the w ater le vel lo wers enough ...

  • Hoshizaki 73180 - page 23

    23 70/21 92 42 89 40 84 38 80/27 81 37 71 32 66 30 90/32 66 30 62 28 57 26 lbs./day kg./day 100/38 55 25 54 24 49 22 70/21 80/27 90/32 watts 100/38 70/21 11 0.04 11 0.04 10 0.04 80/27 10 0.04 9 0.03 8 0.03 90/32 8 0.03 8 0.03 7 0.08 gal./day m 3 /day 100/38 7 0.03 6 0.02 6 0.02 70/21 23 -5 23 -5 23 -5 80/27 23 -5 28 -2 28 -2 90/32 28 -2 28 -2 34 1 ...

  • Hoshizaki 73180 - page 24

    24 IV . Ser vice Diagnosis W ARNING • This unit should be diagnosed and repair ed only b y quali ed ser vice personnel t o reduce the risk of death, electric shock, serious injur y , or re. • Risk of electric shock. Use extr eme caution and ex ercise saf e electr ical practices . • Moving par ts (e .g., f an blade) can crush and cut. Ke ...

  • Hoshizaki 73180 - page 25

    25 6) F reeze Cyc le – BCH, GM, FM, CR, and Comp ener gize. NOTICE! Some units contain a stick er that states: "The bin control heat er has been disconnected. DO NO T reconnect the bin contr ol heater ." In this case , leav e BCH disconnected or replace BC assemb ly with 3A2561A03. Ice production star ts 4 t o 6minut es af ter Comp e ...

  • Hoshizaki 73180 - page 26

    26 2. Auxiliary Codes A-2 and Later This diagnostic procedur e is a sequence check that allo ws you t o diagnose the electr ical sy stem and components . Bef ore pr oceeding, chec k f or correct inst allation, adequate wat er pressur e (7 to 1 1 3PSIG), and proper v oltage per unit nameplat e. When checking v oltage (1 1 5V A C), alw ay s choose ...

  • Hoshizaki 73180 - page 27

    27 Diagnosis – Chec k that UF/S and LF/S open, WCR de-energiz es, and WV energiz es. If UF/S and/or LF/S do not open, see "IV .D . Float Switch Chec k and Cleaning." If WV does not energiz e, check WCR ter minal #2 (GY wir e) to a neutr al (Wwire) f or 1 1 5V AC . If 1 1 5V A C is not present, r eplace WCR. If 1 1 5V A C is present, ...

  • Hoshizaki 73180 - page 28

    28 D . Float S witch Chec k and Cleaning (auxiliar y codes A-2 and lat er) 1 . Float S witch Chec k 1) Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet. 2) Remo ve the upper r ear panel. See Fig . 4. 3) Remo ve the clamp securing the drain plug , then lower the dr ain hose into a cont ainer . ...

  • Hoshizaki 73180 - page 29

    29 UF/S (R wire) Common (BK wir e) LF/S (DBU wir e) Upper Float (blue) Magnet (to war ds top) Magnet (to war ds top) Low er Float (white) Plastic Ret ainer Clip Spring Retainer Clip F ig. 5 2. Float Switc h Cleaning Depending on local wat er conditions, scale ma y build up on F/S . Scale on F/S can cause inconsistent oper ation of UF/S and LF/S. In ...

  • Hoshizaki 73180 - page 30

    30 E. Optional Drain P ump HS-0248 1 . O verview As ice melts, w ater dr ains from the st orage bin into DP . When DP's LF/S closes , DP energiz es and pumps out the water . If wat er cannot be pumped out of DP due to a bloc ked dischar ge hose, bad chec k val ve , or bad DP motor , the wat er lev el r ises and UF/S closes. When UF/S closes , ...

  • Hoshizaki 73180 - page 31

    31 5) If wat er pumps out properly and DP then de-ener gizes , proceed t o step 6. If wat er does not pump out properl y and/or DP does not de-energiz e, f ollow the st eps below t o pr ime D P. Pr iming Instructions a. Disconnect the icemaker's pow er cord fr om the electr ical outlet, then r econnect to the electrical outlet. W ARNING! T o r ...

  • Hoshizaki 73180 - page 32

    32 3. Float Switc h Cleaning Depending on local wat er conditions, scale ma y build up on F/S . Scale on F/S can cause  oat to stic k. In this case, F/S should be cleaned and chec ked. 1) Mov e the power s witch to the "OFF" position, then unplug the icemak er from the electrical outlet. W ARNING! Moving the po wer switc h to the " ...

  • Hoshizaki 73180 - page 33

    33 F . Diagnostic Charts The diagnostic char ts below list possib le reasons f or prob lems with ice production and shutdown. Bef ore consulting the diagnostic charts, check f or correct inst allation, proper v oltage per unit nameplat e, and adequat e wat er supply . 1 . A uxiliary Codes A-1 and Ear lier No Ice Pr oduction - Possib le Cause Startu ...

  • Hoshizaki 73180 - page 34

    34 7. Ev aporator a) Dir ty . b) Damaged or def ective . 8. Condenser a) Dir ty . 9. Refrigerant a) Low char ge or ov ercharged. b) Refrigerant lines or components r estricted. 10 . Wat er Sy stem a) W ater leaks. Shutdown 1. Bin Control Thermostat Assemb ly (with integ rated heat er) NO TICE! Some units contain a stick er that states: "The bi ...

  • Hoshizaki 73180 - page 35

    35 2. Auxiliary Codes A-2 and Later No Ice Pr oduction - Possib le Cause Startup 1. P ower Suppl y a) Unplugged, of f, b lown fuse, or tripped br eaker . b) Not within specications. 2. P ower S witch a) "OFF" position. b) Bad contacts. 3. Bin Control Thermostat Assemb ly (with integ rated heat er) a) Open with bin lled with ice. b) ...

  • Hoshizaki 73180 - page 36

    36 9. Refrigerant a) Low char ge or ov ercharged. b) Refrigerant lines or components r estricted. 10 . Wat er Sy stem a) W ater leaks. Shutdown 1. Bin Control Thermostat Assemb ly (with integ rated heat er) a) Out of position. b) Out of adjustment. See "IV .C. Bin Control Chec k." ...

  • Hoshizaki 73180 - page 37

    37 V . Remo v al and Replacement of Components W ARNING • This unit should be diagnosed and repair ed only b y quali ed ser vice personnel t o reduce the risk of death, electric shock, serious injur y , or re. • Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet befor e ser vicing. ? ...

  • Hoshizaki 73180 - page 38

    38 2. Brazing W ARNING • R-1 34a itself is not ammab le at atmospher ic pr essure and t emperatures up t o 21 2°F (1 00°C). • R-1 34a itself is not explosiv e or poisonous. Howe ver , when e xposed to high temper atures (open  ames), R-1 34a can be decomposed to f or m hy drouoric acid and carbonyl uoride both of which are hazar d ...

  • Hoshizaki 73180 - page 39

    39 5) Disconnect the gauge manif old hose from the v acuum pump and at tach it t o a refrigerant service cylinder . Remember t o loosen the connection and purge the air fr om the hose. See the nameplate f or the requir ed refrigerant charge . Hoshizaki recommends only vir gin refrigerant or r eclaimed refrigerant which meets the r equirements of AR ...

  • Hoshizaki 73180 - page 40

    40 A uger Cut ter (motionless) Extruding Head and Upper Bearing Ev aporator He x Head Bolt with W asher Thumbscre w Housing and Low er Bear ing Gear Motor Spline Coupling Mechanical Seal Spring Retainer Sock et Head C ap Scre w O-Ring F ig. 9 Drain Hose Connection Ev aporator Flange P acking Reservoir Hose Connection Spout Sock et Head C ap Scre w ...

  • Hoshizaki 73180 - page 41

    41 7) Grasp the t op of the auger and mov e the auger to wards y ou and then tr y to inser t a .02" round st ock or pin g auge in bet ween the back side of the auger shaf t and the bearing surface . See Fig . 1 1 . Check se ver al locations around the auger shaf t. If the gauge goes between the shaf t and the bearing at any point or if the bea ...

  • Hoshizaki 73180 - page 42

    42 2. Remo val and R eplacement of Extruding Head 1) Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet. 2) Close the wat er supply line shut-of f val ve . 3) Remo ve all ice fr om the stor age bin. 4) W hile maintaining a hold on the door , remo ve the hinge st op pin from hinge (B). P ull out ...

  • Hoshizaki 73180 - page 43

    43 3. Remo val and R eplacement of Auger 1) Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet. 2) Close the wat er supply line shut-of f val ve . 3) Remo ve all ice fr om the stor age bin. 4) W hile maintaining a hold on the door , remo ve the hinge st op pin from hinge (B). P ull out the bot ...

  • Hoshizaki 73180 - page 44

    44 4. Remo val and R eplacement of Evapor ator NO TICE • Alw ay s install a ne w drier ev er y time the sealed refrigeration s yst em is opened. Do not replace the drier until af ter all other r epair or replacement has been made. • When brazing , prot ect the drier by using a wet cloth t o pre v ent the dr ier fr om ov erheating. Do not allow ...

  • Hoshizaki 73180 - page 45

    45 1 9) Replace the tap-line v alv e with a proper , per manent access v alv e. 20) Remo ve the drier , then place the new drier in position. 21) Braz e all  t tings while purging with nitr ogen gas  owing at a pr essure of 3 t o 4 PSIG. 22) Use an electronic leak det ector or soap b ubb les to chec k for leaks . Add a trace of refrigerant t ...

  • Hoshizaki 73180 - page 46

    46 1 1) R emov e the sock et head cap scre ws secur ing the e xtr uding head and e vapor ator  ange. Remo ve the e vaporat or ange , then grasp the cut ter and car efully lif t out the cut ter and e xtruding head. Grasp the t op of the auger and carefull y lift out the auger . W hen pulling out the auger , the upper par t of the mechanical se ...

  • Hoshizaki 73180 - page 47

    47 6. Remo val and R eplacement of Gear Motor IMPOR T ANT! Hoshizaki recommends that the gear mot or capacitor be r eplaced at the same time as the gear motor . 1) Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet. 2) Close the wat er supply line shut-of f val ve . 3) Remo ve all ice fr om the ...

  • Hoshizaki 73180 - page 48

    48 VI. Maintenance This icemaker m ust be maintained in accor dance with the instruction manual and labels pro vided with the icemaker . Consult with your local Hoshizaki C er ti ed Ser vice Repr esentativ e about maintenance service. W ARNING • Only quali ed ser vice technicians should service this icemaker . • F ailure t o install, oper ...

  • Hoshizaki 73180 - page 49

    49 A. Maintenance Sc hedule The maintenance schedule belo w is a guideline. More fr equent maintenance ma y be requir ed depending on wat er qualit y , the icemaker's en vironment, and local sanit ation regulations . Maintenance Sc hedule F requency Ar ea T ask W eekly Scoop Clean the scoop using a neutral cleaner . Rinse thoroughl y af ter cl ...

  • Hoshizaki 73180 - page 50

    50 B. Cleaning and Sanitizing Instructions 1 . A uxiliary Codes A-1 and Ear lier Hoshizaki recommends cleaning and sanitizing this unit at least twice a year . More frequent cleaning and sanitizing , howe ver , may be r equired in some w ater conditions . W ARNING • T o pr e vent injury to individuals and damage t o the icemaker , do not use ammo ...

  • Hoshizaki 73180 - page 51

    51 4) Remo ve the 2 scr ews securing the t op panel, then lif t it off . 5) Remo ve all ice fr om the stor age bin. 6) Remo ve the slope fr om the stor age bin by car efully bending it in the cent er and releasing it fr om the 2 slope shaf ts. 7) Remo ve the scoop . Remo ve the 2 thumbscr ews securing the scoop holder , then remo ve it. 8) Remo ve ...

  • Hoshizaki 73180 - page 52

    52 c) Sanitizing Solution Dilute 1 .25  . oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorit e solution (chlorine bleach) with 2.5 g al. (9.5 l) of warm water . This is a minimum amount. Make mor e solution if necessar y . Using a chlorine test strip or other method, conr m that you ha ve a concentration of about 200 ppm. IMPOR T ANT! F or ...

  • Hoshizaki 73180 - page 53

    53 1 2) Open the wat er supply line shut-of f v alv e. Check f or leaks. 1 3) Plug the unit back in. Mov e the power s witch to the "ON" position and allow the icemaker t o r un. 1 4) Af ter 30 min utes , mov e the power s witch to the "OFF" position. Unplug the unit. 1 5) P our war m w ater int o the storage bin t o melt all of ...

  • Hoshizaki 73180 - page 54

    54 2. Auxiliary Codes A-2 and Later This icemaker m ust be cleaned and sanitized at least t wice a y ear . More frequent cleaning and sanitizing ma y be requir ed in some wat er conditions. W ARNING • T o pr e vent injury to individuals and damage t o the icemaker , do not use ammonia type cleaners. • C arefull y follo w any instructions pro vi ...

  • Hoshizaki 73180 - page 55

    55 5) Remo ve all ice fr om the stor age bin. 6) Remo ve the slope fr om the stor age bin by car efully bending it in the cent er and releasing it fr om the 2 slope shaf ts. 7) Remo ve the scoop . Remo ve the 2 thumbscr ews securing the scoop holder , then remo ve it. 8) Remo ve the scr ews securing the upper r ear panel, then remo v e it. 9) Remo ...

  • Hoshizaki 73180 - page 56

    56 c) Sanitizing Solution Dilute 1 .25  . oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorit e solution (chlorine bleach) with 2.5 g al. (9.5 l) of warm water . This is a minimum amount. Make mor e solution if necessar y . Using a chlorine test strip or other method, conr m that you ha ve a concentration of about 200 ppm. IMPOR T ANT! F or ...

  • Hoshizaki 73180 - page 57

    57 1 2) Open the wat er supply line shut-of f v alv e. 1 3) Plug the unit back in. Mov e the power s witch to the "ON" position and allow the icemaker t o r un. Check f or leaks. 1 4) Af ter 30 min utes , mov e the power s witch to the "OFF" position. Unplug the unit. 1 5) P our war m w ater int o the storage bin t o melt all of ...

  • Hoshizaki 73180 - page 58

    58 D . Condenser Check the condenser once a y ear , and clean if requir ed by f ollowing the st eps below . More fr equent cleaning may be r equired depending on location. W ARNING • Mov e the power s witch to the "OFF" position, then unplug the unit fr om the electrical outlet befor e cleaning the condenser . • T o r educe the r isk ...

  • Hoshizaki 73180 - page 59

    59 VII. Pr eparing the Icemak er f or P eriods of Non-Use During e xtended periods of non-use, e xtended absences , or in sub-freezing temper atures , follo w the instructions below . When the icemak er is not used for t wo or three da ys under normal conditions, it is suf ficient t o mov e the power s witch to the "OFF" position. W ARNIN ...

  • Hoshizaki 73180 - page 60

    60 VIII. Disposal This unit contains r efrigerant and must be disposed of in accor dance with applicable national, stat e, and local codes and r egulations. Refrigerant must be r ecov ered b y properl y cer tied service personnel. ...

Manufacturer Hoshizaki Category Scuba Diving Equipment

Documents that we receive from a manufacturer of a Hoshizaki 73180 can be divided into several groups. They are, among others:
- Hoshizaki technical drawings
- 73180 manuals
- Hoshizaki product data sheets
- information booklets
- or energy labels Hoshizaki 73180
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hoshizaki 73180.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hoshizaki 73180, service manual, brief instructions and user manuals Hoshizaki 73180. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hoshizaki 73180.

Similar manuals

A complete manual for the device Hoshizaki 73180, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hoshizaki 73180 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hoshizaki 73180.

A complete Hoshizaki manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hoshizaki 73180 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hoshizaki 73180, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hoshizaki 73180, that we can find in the current document
3. Tips how to use the basic functions of the device Hoshizaki 73180 - which should help us in our first steps of using Hoshizaki 73180
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hoshizaki 73180
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hoshizaki 73180 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hoshizaki 73180?

Use the form below

If you did not solve your problem by using a manual Hoshizaki 73180, ask a question using the form below. If a user had a similar problem with Hoshizaki 73180 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)