  • Wasp WWS500 - page 1

    W asp Barcode T echnologies 1400 10th Street Plano, TX 75074 www .waspbar code.com 1007US WWS500 Programming Guide Barcode Scanning Made Easy ...

  • Wasp WWS500 - page 2

    T able of Contents Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Chapter 2. Bar code Symbologies . . . . . . . . . . . . . . . . . . .3 Chapter 3. Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chapter 4. WWS500 Setup & Configuration . . . . . . . .6-28 1. Setup & Configuration . . . . ...

  • Wasp WWS500 - page 3

    Chapter 1 2 Introduction Bar coding is the most common Automated Data Collection (ADC) technology providing timely , error -free information that can be used to increase productivity , accuracy , and efficiency in the workplace. Virtually every type of industr y is using bar codes to replace keyboard data entr y . Studies have shown that a proficie ...

  • Wasp WWS500 - page 4

    Chapter 2 3 Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commer cial products. The bars and spaces in each symbol are grouped in such a way to represent a specific ASCII character or function. The interpretation of these groups is based on a particular set of rules cal ...

  • Wasp WWS500 - page 5

    Chapter 3 4 Quick Start 1. Unpack Open the box and remove all the pieces from their protective packaging. 2. Charging the WWS500 Y ou must charge the scanner for 4 hours before first using it. T o charge the scanner plug the power supply in to the bottom of the scanner . 3. Setting up the Bluetooth Adaptor If you already have Bluetooth setup on you ...

  • Wasp WWS500 - page 6

    Chapter 3 5 The following screens are Microsoft’ s standard Bluetooth wizard. *Most Bluetooth wizards will have similar steps.   Check the “My device is setup and ready to be found.” and click Next. The scanner will show up in the list of Bluetooth devices found. Select the WASP_HID and click Next. * If WASP_HID does not show up in the ...

  • Wasp WWS500 - page 7

    Chapter 4 6 In order to configure Wasp WWS500 Freedom Scanner , you must familiarize yourself with the setup procedures on the following pages. The default settings of the scanners are identified on each page and clearly marked using an asterisk (*). The default settings have been preprogrammed for the most common barcode configurations. Use the se ...

  • Wasp WWS500 - page 8

    Chapter 4 7 F ACTOR Y DEF AUL T & KEYBOARD CONNECTION Use the Factory Default barcode to reset the scanner to the Default settings. Factor y Default Autosense Flash Mode Enable Scan this Autosense Stand Mode bar code to enable the hands-free autosense feature of the WWS500 Freedom Scanner . If you desire to turn this mode “off,” please scan ...

  • Wasp WWS500 - page 9

    Chapter 4 8 BEEP AND DELA Y The 'Beep and Delay' configuration supports the general control options for the Wasp WWS500 Freedom Scanner . These options include the volume, inter character delay , and interblock delay . Interblock delay is the minimum time interval between two adjacent scans. If the processing speed of your host device is ...

  • Wasp WWS500 - page 10

    Chapter 4 9 BEEP AND DELA Y 0ms * 10ms 50ms 100ms 200ms 140us * 500us 1ms 4ms 16ms 500ms Interblock Delay Intercharacter Delay *Default ...

  • Wasp WWS500 - page 11

    Chapter 4 10 UPPER/LOWER CASE • Caps Lock Auto (For PC XT/A T only): In Auto mode, the scanner will keep track of the Caps Lock status automatically . For some PCs, the scanning per formance may be compromised because of the auto tracing. If the scanning per formance is poor (or cannot scan) or the scanner cannot output the upper/lower case chara ...

  • Wasp WWS500 - page 12

    Chapter 4 11 KEYBOARD LANGUAGE U.S. * German French Spanish Italian The ‘Keyboard Language’ setting controls the key codes for your keyboard’ s language. *Default ...

  • Wasp WWS500 - page 13

    Chapter 4 12 PREAMBLE/POST AMBLE CONFIGURA TION The ‘Preamble/Postamble’ configuration is used to add a prefix or suffix set of characters to the bar code value. Up to 8 characters may be added for each option separately . Preamble and postamble characters can function concurrently , but need to be configured separately . T o add preamble or po ...

  • Wasp WWS500 - page 14

    Chapter 4 13 TERMINA TOR/CODE ID O - MSI/Plessey T - EAN 128 S - EAN 8 K - Code 128 E - UPC E N - Codabar A - UPC A D - Full ASCII Code 39 F - EAN 13 M - Std. Code 39 L - Code 93 I - Interleaved 2 of 5 T erminator CR * None Code ID Code ID On Code ID Off * LF CR + LF Ta b Space ESC The ‘T erminator’ option is used to specify the end-of-text mes ...

  • Wasp WWS500 - page 15

    Chapter 4 14 ENABLE/DISABLE BARCODE SYMBOLOGIES Enable Disable Enable All MSI Plessey Interleaved 2 of 5 * Code 128 * Codabar * Code 39 * Disable All MSI Plessey * Interleaved 2 of 5 Code 128 Codabar Code 39 *Default ...

  • Wasp WWS500 - page 16

    Chapter 4 15 ENABLE/DISABLE BARCODE SYMBOLOGIES Enable Disable UPC A * UPC E * EAN 8 * EAN 13 * Code 93 UPC A UPC E EAN 8 EAN 13 Code 93 * *Default ...

  • Wasp WWS500 - page 17

    Chapter 4 16 CODE 39 SETTINGS Enable Code 39 * Enable Code 39 Full ASCII * Check Digit Do Not Calculate * Check Digit Calculate But Do Not Send * Minimum Length (1 *) Disable Code 39 Disable Code 39 Full ASCII Check Digit Calculate And Send Maximum Length (48 *) Code 39 is variable length and is the most frequently used symbology in industrial bar ...

  • Wasp WWS500 - page 18

    Chapter 4 17 INTERLEA VED 2 OF 5 AND CODE 93 SETTINGS Enable Code 93 Disable Code 93 * Enable Interleaved 2 of 5 * Check Digit Do Not Calculate * Check Digit Calculate But Do Not Send Minimum Length (6 *) Maximum Length (48 *) Disable Interleaved 2 of 5 Check Digit Calculate And Send Interleaved 2 of 5 is a variable length, even numbered, numeric b ...

  • Wasp WWS500 - page 19

    Chapter 4 18 CODE 128 AND UCC/EAN 128 SETTINGS Code 128 is the most flexible of all the common linear symbologies. It supports alpha and numeric characters easily , has the highest number of characters per inch, and is variable length. See page 6 for information on setting the minimum and maximum lengths. T o Define UCC/EAN 128 Group Separator: 1 . ...

  • Wasp WWS500 - page 20

    Chapter 4 19 MSI PLESSEY SETTINGS MSI Plessey is a variable length numeric symbology and is primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code. See page 6 for information on setting the minimum and maximum lengths. En ...

  • Wasp WWS500 - page 21

    Chapter 4 20 CODABAR SETTINGS Codabar is a variable length symbology capable of encoding six special alphanumeric characters, capital letters A through D, T , N, *, E, and all numeric digits. Codabar is one of the oldest bar code symbologies and is still used in some library applications. It should not be considered for new applications except unde ...

  • Wasp WWS500 - page 22

    Chapter 4 21 UPC-A SETTINGS UPC-A (Universal Product Code-A) is fixed length and is the most common UPC bar code for retail product labeling. It is seen in most grocery stores across the United States. The symbology encodes a 12-digit number . The first six digits are assigned from the Uniform Code Council (UCC). The next five digits are assigned b ...

  • Wasp WWS500 - page 23

    Chapter 4 22 UPC-A SUPPLEMENT SETTINGS / UPC-A TO EAN-13 This option enables the two and five digit supplements for the UPC and EAN/JAN bar code symbologies. 5 Digit Supplement Enable 2 Digit Supplement Enable T ransmit if Present 5 Digit Supplement Disable * This option expands the UPC-A bar code to EAN-13. UPC-A to EAN-13 Enable UPC-A to EAN-13 D ...

  • Wasp WWS500 - page 24

    Chapter 4 23 UPC-E SETTINGS UPC-E (Universal Product Code-E) is fixed length and is a compressed six digit code used for marking small packages, including magazines and paperback books. UPC-E symbols are UPC-A symbols that have been zero suppressed (i.e. consecutive zeros are not included in the symbol). The printed value of the UPC-E code is a twe ...

  • Wasp WWS500 - page 25

    Chapter 4 24 UPC-E SUPPLEMENT SETTINGS This option enables the two and five digit supplements for the UPC and EAN/JAN bar code symbologies. 5 Digit Supplement Enable 2 Digit Supplement Enable T ransmit if Present 5 Digit Supplement Disable * 2 Digit Supplement Disable * Must Be Present * *Default ...

  • Wasp WWS500 - page 26

    Chapter 4 25 EAN-8 SETTINGS The EAN/JAN-8 is fixed length and is similar to the UPC-E code, but includes two more digits for the country code. The nominal height for the EAN/JAN-8 bar code is one inch. The reduced size is 80% of the nominal size. EAN-8 Enable * Send Leading Digit * Send Check Digit * EAN-8 Disable Do Not Send Leading Digit Do Not S ...

  • Wasp WWS500 - page 27

    Chapter 4 26 EAN-8 SUPPLEMENT SETTINGS This option enables the two and five digit supplements for the UPC and EAN/JAN bar code symbologies. 5 Digit Supplement Enable 2 Digit Supplement Enable T ransmit if Present 5 Digit Supplement Disable * 2 Digit Supplement Disable * Must Be Present * *Default ...

  • Wasp WWS500 - page 28

    Chapter 4 27 EAN-13 SETTINGS The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology , but encodes a 13th digit. The nominal height for the EAN/JAN-8 bar code is one inch. The reduced size is 80% of the nominal size. EAN-13 Enable * Send Leading Digit * Send Check Digit * EAN-13 Disable ...

  • Wasp WWS500 - page 29

    Chapter 4 28 EAN-13 SUPPLEMENT SETTINGS This option enables the two and five digit supplements for the UPC and EAN/JAN bar code symbologies. 5 Digit Supplement Enable 2 Digit Supplement Enable T ransmit if Present 5 Digit Supplement Disable * 2 Digit Supplement Disable * Must Be Present * *Default ...

  • Wasp WWS500 - page 30

    Chapter 5 29 BLUETOOTH SETTINGS See Chapter 3 for step-by-step setup instructions. Scan the “Set Connection” bar code before pairing up the WWS500 Freedom Scanner and the Bluetooth dongle/internal Bluetooth adaptor . Connect and Disconnect 1 Minute Bluetooth Power Off Settings Set Connection 5 Minutes 3 Minutes 10 Minutes Scan the “Disconnect ...

  • Wasp WWS500 - page 31

    Appendix A 30 BARCODE TEST SYMBOLS Code 39* Interleaved 2 of 5 * Codabar * Code 128* MSI/Plessey Code 93 Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan. Use the 'Barcode Symbologies' configuration beginning on page 14 to enable specific symbologies. *Default ...

  • Wasp WWS500 - page 32

    Appendix A 31 BARCODE TEST SYMBOLS UPC-A* UPC-E* UPC-E w/5 digit supplement UPC-E w/2 digit supplement UPC-A w/2 digit supplement UPC-A w/5 digit supplement *Default ...

  • Wasp WWS500 - page 33

    Appendix A 32 BARCODE TEST SYMBOLS EAN/JAN-8* EAN/JAN-8 w/5 digit supplement EAN/JAN-8 w/2 digit supplement EAN/JAN-13* EAN/JAN-13 w/2 digit supplement EAN/JAN-13 w/5 digit supplement *Default ...

  • Wasp WWS500 - page 34

    Appendix B 33 ASCII T ABLE Use this ASCII T able to add preamble and postamble characters to your bar code value. Please refer to the appropriate configuration section for the number of characters that can be configured. NUL SOH STX ETX EO T ENQ AC K BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK CAN SUB FS SYN EM ESC GS ETB ...

  • Wasp WWS500 - page 35

    Appendix B 34 ASCII T ABLE ! # % ' ) + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > SP " $ & ( * RS US ...

  • Wasp WWS500 - page 36

    Appendix B 35 ASCII T ABLE H I J K L M N O P Q R S T U V W B C D E F G ? @ A X Y [ ] _ ^ Z ...

  • Wasp WWS500 - page 37

    x y z { | } ~ DEL n o p q r s t u v w a c e g i k m ` b d f h j l Appendix B 36 ASCII T ABLE ...

  • Wasp WWS500 - page 38

    Appendix C 37 FUNCTION CODE FOR PC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Cursor Right Cursor Left Cursor Up Cursor Down P age Up P age Do wn Ta b Bac k T ab Esc Enter End Ins Home Bac k Space Del ...

  • Wasp WWS500 - page 39

    38 MODEL WWS500 OPTICAL Object / Image Path 135mm + 5mm Depth of Field 50 ~ 120 mm (Code 39, 5 mil) Width of Field 120 mm (40 mil) Scan Rate 230 scans / second ELECTRICAL Light Sour ce 625 ~ 660 nm visible red LED Sensor 2088 Element linear imager Operating Current <230 mA Standby Current <120 mA Battery Charger (AC Adaptor) 3.7 VDC Battery T ...

  • Wasp WWS500 - page 40

    39 Wasp Bar code T echnologies products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at Wasp Bar code T echnologies option, with reasonab ...

  • Wasp WWS500 - page 41

    40 Q: How do I change the terminator to a T ab? A: Scan the “T ab” barcode on page 13. Q: How do I remove the terminator? A: Scan the “None” bar code on page 13. Q: How do I enable the Full ASCII character set for the Code 39 bar code symbology? A: Scan the “Enable Code 39 Full ASCII” bar code on page 16. Q: If my PC is Bluetooth HID en ...

  • Wasp WWS500 - page 42

    W asp Barcode T echnologies 1400 10th Street Plano, TX 75074 www .waspbarcode.com 1007US WWS500 Programming Guide Barcode Scanning Made Easy ...

Manufacturer Wasp Category Scanner

Documents that we receive from a manufacturer of a Wasp WWS500 can be divided into several groups. They are, among others:
- Wasp technical drawings
- WWS500 manuals
- Wasp product data sheets
- information booklets
- or energy labels Wasp WWS500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Wasp WWS500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Wasp WWS500, service manual, brief instructions and user manuals Wasp WWS500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Wasp WWS500.

Similar manuals

A complete manual for the device Wasp WWS500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Wasp WWS500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Wasp WWS500.

A complete Wasp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Wasp WWS500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Wasp WWS500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Wasp WWS500, that we can find in the current document
3. Tips how to use the basic functions of the device Wasp WWS500 - which should help us in our first steps of using Wasp WWS500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Wasp WWS500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Wasp WWS500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Wasp WWS500?

Use the form below

If you did not solve your problem by using a manual Wasp WWS500, ask a question using the form below. If a user had a similar problem with Wasp WWS500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)