    Operating Manual Internal GPIB Interface for XPD Series Programmable DC Power Supply GPIB-XPD ...

  • Xantrex GPIB-XPD - page 2

    ...

  • Xantrex GPIB-XPD - page 3

    Operating Manual for Internal GPIB Interface for XPD 500 Watt Series Programmable DC Power Supply ...

  • Xantrex GPIB-XPD - page 4

    ii Operating Manual for GPIB for XPD Series Power Supply Limited W arranty What does this warranty cover and how long do es it last? This Limited W arranty is pro vided by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your GPIB Interfac e Card . This warranty lasts for a W arranty Period of 5 years fr ...

  • Xantrex GPIB-XPD - page 5

    Release 1.2 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy describ ed in your pr oduct manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantre x or check our website to see if your product can be repaired at one of these facilities. In any warrant ...

  • Xantrex GPIB-XPD - page 6

    iv Operating Manual for GPIB for XPD Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE PERMIT TED BY LA W , IN LIEU OF ALL OTHER W ARRANT IES, CONDITIONS, GUARANTEES, REPRESENT A TIONS, OBLI GA TIONS AND LIABILITIES, EXPRES S O ...

  • Xantrex GPIB-XPD - page 7

    Release 1.2 v Information WITHOUT LIMITING THE GENERA LITY OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED T O BY IT IN WRI TING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR O THER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b. A ...

  • Xantrex GPIB-XPD - page 8

    vi Operating Manual for GPIB for XPD Ser ies Power Supply Power Supply Safety W arnings, Cautions, and Notes W arnings, cautions, and notes are defined and formatted in this manual as shown below . W ARNING—High Ener gy and High V olt age Exercise caution when using and calibrating a power supply . High energy levels can be stored at the output v ...

  • Xantrex GPIB-XPD - page 9

    Release 1.2 vii About This Manual This technical manual is for the internal GPIB interface, a microprocessor-controlled option card for XPD Series DC outpu t power supplies. This manual provides you with descriptions and specif ications, user options, and co nfiguration instructions, in addition to a command set wh ich enables you to manage the pow ...

  • Xantrex GPIB-XPD - page 10

    About This Manu al viii Operating Manual for GPIB for XPD Series Power Supply ...

  • Xantrex GPIB-XPD - page 11

    Release 1.2 ix Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specificati ons Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features and Functions . . . . . ...

  • Xantrex GPIB-XPD - page 12

    Content s x Operating Manual for GPIB for XPD Series Power Supply Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Diagnostic LEDs . . . . . . . . ...

  • Xantrex GPIB-XPD - page 13

    Release 1.2 11 Section 1. Features and S pecifications Description The internal GPIB interface card allows you to operate your power supply from a computer controller via the IEEE-488 commun ications bus. See Figure 1.1, “Sample Configuration using GPIB Interface”. The GPIB interface allows co mplete remote programmin g of your po wer supply , ...

  • Xantrex GPIB-XPD - page 14

    Features and Specifications Features and Functions 12 Operating Manual for GPIB for XPD Series Power Supply Features and Functions Features • 16-bit programming and read back of voltage an d current • Programmable soft limits for voltage and current • Programmable over volta ge protection with reset • Easy-to-use, self-docum enting command ...

  • Xantrex GPIB-XPD - page 15

    Features and Specifications Specifications Release 1.2 13 Specifications The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice. T a ble 1.1 S pecifications for XPD 500 W Series Su pply wit h GPIB Interface I nstalled Models 7.5-67 18-30 33-16 60-9 120-4.5 ...

  • Xantrex GPIB-XPD - page 16

    Features and Specifications Specifications 14 Operating Manual for GPIB for XPD Series Power Supply ...

  • Xantrex GPIB-XPD - page 17

    Release 1.2 15 Section 2. Inst allation and Configuration Introduction T o use this product, you must have the following equ ipment: • a compatible model of DC output power su pply • IEEE-488 connector and cable • computer with an IEEE-488 interface • Computer-based communications software package W e usually install the GPIB interfa ce in ...

  • Xantrex GPIB-XPD - page 18

    Inst allation and Configuration Initial Inspection 16 Operating Manual for GPIB for XPD Series Power Supply Figure 2.1 Power Supply Front Panel wit h GPIB Interface Installed ! CAUTION Use proper static control techniques to av oid dama ge to static-sensitive compo nents on the printed circuit board. Service Request L ED (SRQ) Comes on at power up ...

  • Xantrex GPIB-XPD - page 19

    Inst allation and Configuration Initial Inspectio n Release 1.2 17 Figure 2.2 GPIB Interf ace Subplate (Located on Power Supply Rear Pane l) ! CAUTION Use proper static control techniques to av oid dama ge to static-sensitive compo nents on the printed circuit board S1 Switch 1 Remote/Local S tartup 2 Power On Servi ce Reques (Enable/Disabl e) 3 No ...

  • Xantrex GPIB-XPD - page 20

    Inst allation and Configuration Initial Inspection 18 Operating Manual for GPIB for XPD Series Power Supply Figure 2.3 GPIB Interface PCB JUMPER SELECTION J2 Local OVP control selection [closed] [default]. See page 23. [open] Front Panel OVP Control. J3 User TTL shutdown (S/D) selection [1-2] User TTL S/D line active low . See page 27. [2-3] [defau ...

  • Xantrex GPIB-XPD - page 21

    Inst allation and Configuration Basic Setup Procedure Release 1.2 19 Basic Setup Procedure This procedure can be used as a quick reference for those familiar with the configuration requirements for the GPIB interface as installed in the DC power supply . For those who want mo re information, each step refers to more detailed procedures located in s ...

  • Xantrex GPIB-XPD - page 22

    Inst allation and Configuration IEEE-488 Primary Address Selection 20 Operating Manual for GPIB for XPD Series Power Supply IEEE-488 Primary Address Selection 1. Assign a primary address to each power su pply: Choose a number between 0 and 30 which is unique to your IEEE-48 8 bus, that is, different from other device addresses on the same bus. 2. L ...

  • Xantrex GPIB-XPD - page 23

    Inst allation and Configuration Power On Service Request (PON SRQ) Release 1.2 21 Power On Service Request (PON SRQ) The Power ON Service Request (SRQ) switch is located on the GP IB subplate rear panel S1 switch. Enabling the SRQ switch caus es the power supply to send a service request to the computer cont roller wh en the power supply is turned ...

  • Xantrex GPIB-XPD - page 24

    Inst allation and Configuration Remote/Local Operation 22 Operating Manual for GPIB for XPD Series Power Supply If the rear panel PON REM switch is set to 1, the power supply will power up in local mode. Power supply co ntrol is at the front panel. During an operating session, you can toggle between local mode and remote mode by sending commands as ...

  • Xantrex GPIB-XPD - page 25

    Inst allation and Configuration IEEE-488 Controller Connection Release 1.2 23 T o return to remote mode, ensure that the REN line is asserted and then send any valid GPIB or device-depen dent command. Local Mode Operation In local mode operation, the voltage and current output levels and the OVP trip level are set with controls located on the front ...

  • Xantrex GPIB-XPD - page 26

    Inst allation and Configuration Internal PCB Jum per Selections 24 Operating Manual for GPIB for XPD Series Power Supply the front panel LOCAL switch, control of the OVP trip level changes from software control to the front panel OVP po tentiometer . The default OVP trip level is set as 1 10% of the power supply's rated output voltage. See T a ...

  • Xantrex GPIB-XPD - page 27

    Inst allation and Configuration User Signals Release 1.2 25 T a ble 2.7 Switch Settings for TTL Shut down Circuit Logic User Signals Connector J21 User Signals Auxiliary connector J21, loca ted on the GPIB interface rear panel, provides several signals to increase your operating cont rol of the supply . These signals are dependent o n the operator& ...

  • Xantrex GPIB-XPD - page 28

    Inst allation and Configuration User Signals 26 Operating Manual for GPIB for XPD Series Power Supply Figure 2.4 User Signals J21 Connector J21-1 External TTL shutdo wn input signal (See “TTL Shutdown”) J21-2 Polarity signal, open collector (asserted by VSET -x) J21-3 Isolation signal, open collector (asserted by OUT OFF) J21-4 Fault signal, op ...

  • Xantrex GPIB-XPD - page 29

    Inst allation and Configuration User Signals Release 1.2 27 Figure 2.5 J21 User Signal Connector Circuit Block Diagram J21 Cable Connection Use a standard 8-position telephone jack an d data cable to connect to J21. Add a ferrite block to reduce radiated emission . The one inch square ferrite block with built-in housing clip is pack aged and shippe ...

  • Xantrex GPIB-XPD - page 30

    Inst allation and Configuration User Signals 28 Operating Manual for GPIB for XPD Series Power Supply Figure 2.6 J21 User Cable with Ferrite Block J21 User Cable Ferrite Block T o User Custom Interface T o J21 Connector ...

  • Xantrex GPIB-XPD - page 31

    Release 1.2 29 Section 3. Operation Introduction This section covers GPIB interface progra mming, st arting with IEEE-488 functions, continuing with an extensive set of de vice-dep endent commands, and, finally , providing error codes, and status and fault register information. GPIB Operation A GPIB interface controller card enables yo u to control ...

  • Xantrex GPIB-XPD - page 32

    Operation GPIB Operation 30 Operating Manual for GPIB for XPD Series Power Supply Ta b l e 3 . 1 IEEE-488.1 Interface F unctions Implemented Multiline Control Functions The GPIB interface a nd the computer cont roller implement the Acceptor Handshake, Source Handshake, Listener , and T alker fu nctions. No user actio n is required. The unit's ...

  • Xantrex GPIB-XPD - page 33

    Operation GPIB Operation Release 1.2 31 Device T rigger Device T rigger will implement t he most recently programmed values whether the unit is in local or remote co ntrol. If the power supply is in local mode, the new values will be implemented when it is switched from local to remote control. Device T rigger is typically used to synchronize the o ...

  • Xantrex GPIB-XPD - page 34

    Operation GPIB Operation 32 Operating Manual for GPIB for XPD Series Power Supply Serial Poll In a serial poll, the controlle r polls each device. Example: The power supply responds with a 8- bit status byte defined as follows: T a ble 3.2 Serial Poll S tatus Register ibrsp Return serial poll byte. Bit Position Decimal Wei g h t Description Reset B ...

  • Xantrex GPIB-XPD - page 35

    Operation Command Syntax Release 1.2 33 Command Synt ax Manual Conventions The manual uses these conven tions when displayi ng command information. These characters are not part of the command but are used to denote parameters used with the comma nd. Command Format and Parameters The device-dependent language for the GPIB Interface consists of comm ...

  • Xantrex GPIB-XPD - page 36

    Operation Command Syntax 34 Operating Manual for GPIB for XPD Series Power Supply • Use commas between parameters in th ose commands with more than one parameter , and between mnemonic para meters as in the MASK and UNMASK commands. Only one comma is allowed and it may be preceded or followed by any number of spaces. Example: MASK CV , OV , FOLD ...

  • Xantrex GPIB-XPD - page 37

    Operation Command Syntax Release 1.2 35 Command Strings If you send more than one command line, separate the commands with a semicolon. The semicolon may be preceded or followed by spaces. Example: Command T erminators T erminators indicate the end of a command string and tell the power supply to execute the command. The termina tion character is L ...

  • Xantrex GPIB-XPD - page 38

    Operation Command Summary 36 Operating Manual for GPIB for XPD Series Power Supply Command Summary Use these commands to control the opera tion of the supply . They are listed here in order of function such as PROGRAMMING , QUER Y , CALIBRA TION, and ST A TUS commands. See “Command Refe rence” on page 39 for more detailed information about each ...

  • Xantrex GPIB-XPD - page 39

    Operation Command Summary Release 1.2 37 T a ble 3.6 Query Commands Command Description AUXA? Asks for the state of the set value for the AUXA command AUXB? Asks for the state of the set value for the AUXB command CMODE? Asks for the power supply’ s calibration mode st atus. DL Y? Asks for the programmable time delay setting before the supply rep ...

  • Xantrex GPIB-XPD - page 40

    Operation Command Summary 38 Operating Manual for GPIB for XPD Series Power Supply T a ble 3.7 Calibration Commands T a ble 3.8 S tatus Commands Command Description CMODE Places the supply into calibration mode. IDA T A Calculates the slope and intercept for current programming. IHI Sets the current output to the high calibration point. ILO Sets th ...

  • Xantrex GPIB-XPD - page 41

    Operation Command Reference Release 1.2 39 Command Reference T a ble 3.9 Command Refe rence Command Description ASTS? Asks for the supply’s accumulate d status register . The accumulated status register stores any bit that was entered in the status register since the accumulated status query command (ASTS?) was last used, regard less of whether t ...

  • Xantrex GPIB-XPD - page 42

    Operation Command Reference 40 Operating Manual for GPIB for XPD Series Power Supply Command Description DL Y <seconds> Sets a programmable time delay employed by the supply before reporting fault conditions. The power supply uses the time delay after receiving a new output voltage or current setting via VSET or ISET , or after receiving RST ...

  • Xantrex GPIB-XPD - page 43

    Operation Command Reference Release 1.2 41 Command Description FOLD? Asks for the supply’s present foldback setting. Response: FOLD <mode> where mode is: 0 (OFF) or 1 (CV or Const ant V oltage mode) or 2 (CC or Const ant Current mode) HOLD <1/ON>,<0/OFF> Enables or disables voltage/current setting hold mode for the supply . When ...

  • Xantrex GPIB-XPD - page 44

    Operation Command Reference 42 Operating Manual for GPIB for XPD Series Power Supply Command Description IRDA T <Ilo>,<Ihi> Calculates and records the slope and of fset for readback volt age using IRLO and IRHI data. Set CMODE ON before using this command. See also the calibration procedures in Section 4. <Ilo> and <Ihi> are ...

  • Xantrex GPIB-XPD - page 45

    Operation Command Reference Release 1.2 43 Command Description OVCAL Causes the master controller to perform automatic calibration of the supply’s over volt age protection circuitry . Set CMODE O N before using this command. Ensure jumper J2 on the GPIB Interface PCB is connected for remote operation. OVSET <voltage> Sets the supply’ s ov ...

  • Xantrex GPIB-XPD - page 46

    Operation Command Reference 44 Operating Manual for GPIB for XPD Series Power Supply Command Description TRG Implements programmed volt age and current settings which had been in hold mode. The supply operates with previous values until the TRG (trigger) command is sent. UNMASK <mnemonics> Enables you to select the s upply operating condition ...

  • Xantrex GPIB-XPD - page 47

    Operation Command Reference Release 1.2 45 Command Description VMAX <voltage> Sets an upper sof t limit on the supply’s programmed output volt age. If the soft limit is exceeded, or if the sof t limit value is lower than the present output voltage setting, the supply will ignore the command, turn on the ERR LED, and set the ERR bit in the a ...

  • Xantrex GPIB-XPD - page 48

    Operation Accumulated Status, S tatus, and Fault Registers 46 Operating Manual for GPIB for XPD Series Power Supply Accumulated S t atus, S t atus, and Fault Registers The GPIB option card uses three separate registe rs which are always active. They are the accumulated status, status, and fault registers. Y ou can use the status commands shown in T ...

  • Xantrex GPIB-XPD - page 49

    Operation Error Codes Release 1.2 47 Error Codes If the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an error number which corresponds to an event described in the following table. The ERR? query will a lso clear the ERR bit in the register . T a ble 3.1 1 Error Codes ERROR # E RROR IDENTIFICA ...

  • Xantrex GPIB-XPD - page 50

    Operation T roubleshooting 48 Operating Manual for GPIB for XPD Series Power Supply T roubleshooting Diagnostic LEDs This section describes the diagnostic LEDs found on the GPIB interface. Computer Operating Prope rly (COP) LEDs The GPIB interface provides three diagnostic LEDs, located at D5 , D4, and D1 on its PCB. Refer to Figure 2.3, ‘GPIB In ...

  • Xantrex GPIB-XPD - page 51

    Release 1.2 49 Section 4. Calibration Introduction Y ou can calibrate the GPIB interface by adjusting the signal levels on the interface card so that they correspond to the expected signal levels on the power supply's main assembly . Y ou may need to recalibrate the in terface if you replace parts either on the interface board or on the main p ...

  • Xantrex GPIB-XPD - page 52

    Calibration V oltage Mod e Calibration 50 Operating Manual for GPIB for XPD Series Power Supply V olt age Mode Calibration V oltage Calibration Setup 1. Disconnect the load from the power su pply which is to be calibrated. 2. Connect a voltmeter across the po wer supply’ s output terminals. Figure 4.1 V oltage Calibration Setup V oltage Program C ...

  • Xantrex GPIB-XPD - page 53

    Calibration V oltage Mode Calibration Release 1.2 51 3. Send command VRLO; IRLO to the power supply . W ait for the supply to settle. Measure and record the output shown on the external voltmet er . Send VRLO again. 4. Send VRHI; IRHI to the supply . W ait for the supply to settle. Measure and record the output voltage shown on the external voltmet ...

  • Xantrex GPIB-XPD - page 54

    Calibration Current Mode Calibration 52 Operating Manual for GPIB for XPD Series Power Supply Current Mode Calibration Current Calibration Setup 1. Disconnect the load from the po wer supply to be calibrated. 2. Connect a shunt across the supply's output terminals. 3. Connect a voltmeter across the shunt. Figure 4.2 Current Calibration Setup C ...

  • Xantrex GPIB-XPD - page 55

    Calibration Current Mode Calibration Release 1.2 53 Current Readback Calibration Procedure 1. Connect the curre nt shunt and voltmeter to the power supply as shown in Figure 4.2. 2. Activate calibration mode by sendi ng command CMODE ON or CMODE 1 to the power supply . 3. Send command IRLO; VRLO to the power supply . W ait for the supply to settle. ...

  • Xantrex GPIB-XPD - page 56

    Calibration Over V oltage Protection (OVP) Calibration 54 Operating Manual for GPIB for XPD Series Power Supply Over V oltage Protection (OVP) Calibration W e recommend that you perform OVP ca libration every six mon ths. Connecting a digital voltmeter as in “V oltage Calibration Setu p” is optional. 1. Disconnect all loads from the power suppl ...

  • Xantrex GPIB-XPD - page 57

    ...

  • Xantrex GPIB-XPD - page 58

    Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B 5 604 422 85 95 T el 604 421 30 56 F a x 800 667 8422 T oll Free North America prg.info@xantrex.com www .xantre x.com TM-GPPD-01XN PRINTED IN CANADA ...

Manufacturer Xantrex Category Power Supply

Documents that we receive from a manufacturer of a Xantrex GPIB-XPD can be divided into several groups. They are, among others:
- Xantrex technical drawings
- GPIB-XPD manuals
- Xantrex product data sheets
- information booklets
- or energy labels Xantrex GPIB-XPD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Xantrex GPIB-XPD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Xantrex GPIB-XPD, service manual, brief instructions and user manuals Xantrex GPIB-XPD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Xantrex GPIB-XPD.

Similar manuals

A complete manual for the device Xantrex GPIB-XPD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Xantrex GPIB-XPD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Xantrex GPIB-XPD.

A complete Xantrex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Xantrex GPIB-XPD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Xantrex GPIB-XPD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Xantrex GPIB-XPD, that we can find in the current document
3. Tips how to use the basic functions of the device Xantrex GPIB-XPD - which should help us in our first steps of using Xantrex GPIB-XPD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Xantrex GPIB-XPD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Xantrex GPIB-XPD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Xantrex GPIB-XPD?

Use the form below

If you did not solve your problem by using a manual Xantrex GPIB-XPD, ask a question using the form below. If a user had a similar problem with Xantrex GPIB-XPD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)