  • Graco Inc. 223451 - page 1

    308018 Rev . W 06615 NOTE: Any modification of genuine Graco parts or replacement of parts with non-Graco parts will void agency approvals. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Model PRO 3500hc  Electrostatic Air Spray Gun 65 kV , HIGH CONDUCTIVITY , MANUAL GU ...

  • Graco Inc. 223451 - page 2

    2 308018 ...

  • Graco Inc. 223451 - page 3

    308018 3 T able of Contents W arnings 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How the Electrostatic Air Spray Gun W orks 6 . . . . Converting a P ...

  • Graco Inc. 223451 - page 4

    4 308018 W ARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in a fire, explosion, or electric shock.  Electrostatic equipment must be used only by trained, qualified personnel who understand the requirements stated in this instruction man ...

  • Graco Inc. 223451 - page 5

    308018 5 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause a serious injury .  Do not point the spray gun at anyone or any part of the body .  Do not stop or deflect fluid leaks with your hand, body , glove, or rag.  Follow the Pressure Relief ...

  • Graco Inc. 223451 - page 6

    6 308018 Introduction How the Electrostatic Air Spray Gun Works The air hose supplies air to the spray gun. Part of the air operates the turbine and the rest of the air atomizes the fluid being sprayed. The turbine generates power , which is converted by the power cartridge, to supply high voltage current to the gun ’ s ionizing electrode. The pu ...

  • Graco Inc. 223451 - page 7

    308018 7 Converting a PRO 3500sc Gun to a PRO 3500hc Gun 06616 Fig. A A B F G H J K L M C D E 06618 Fig. B 10 12 06619 Fig. C 06617 G H J 28 D E F 10 12 12a 12b Fig. D L M ...

  • Graco Inc. 223451 - page 8

    8 308018 Installation KEY A Main Air Supply Line B* V entilation Fan Interlock Solenoid V alve C* Main Air Supply Shutoff V alve (bleed-type) D Air & Water Separator E* Pump Air Supply Shutoff V alve (bleed-type) F Air Line Lubricator G Air Pressure Regulator H Pump J* Pump Ground Wire K Fluid Filter L Fluid Supply Line Shutoff V alve M Fluid P ...

  • Graco Inc. 223451 - page 9

    308018 9 Installation Installing the System W ARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Installing and servicing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly .  Do not install or service this equip- ment unless you are trained and qualified.  Be sure y ...

  • Graco Inc. 223451 - page 10

    10 308018 Installation Connect the Exhaust T ube Press the exhaust tube (provided) onto the barbed adapter on the bottom of the gun handle. Secure the tube with the clamp provided. Refer to page 36. Connect the Fluid Line (Refer to Fig. 1) 1. Before connecting the fluid line (N), blow it out with air and flush it with solvent. Use solvent which is ...

  • Graco Inc. 223451 - page 11

    308018 1 1 Installation Check the Electrical Grounding (See Fig. 2) W ARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Megohmmeter P/N 241079 (AA-see Fig. 2) is not approved for use in a hazard- ous area. T o reduce the risk of sparking, do not use the megohmmeter to check electrical grounding unless:  The gun has been removed from the hazardou ...

  • Graco Inc. 223451 - page 12

    12 308018 Notes ...

  • Graco Inc. 223451 - page 13

    308018 13 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally . T o reduce the risk of an injury from electric shock, accidental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure ...

  • Graco Inc. 223451 - page 14

    14 308018 Operation 05151A Fig. 4 06615 20 1 26 45 43 31 DD Selecting a Fluid Nozzle and Air Cap W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of an injury , follow the Pressure Relief Procedure on page 13 before removing or installing a fluid nozzle and/or air cap. The gun is supplied with a 0.059 in. (1.5 mm) fluid nozzle, P/N 185158, ...

  • Graco Inc. 223451 - page 15

    308018 15 Operation Operating the Spray Gun (continued) 1. Follow the Operating Checklist on page 13. 2. T o adjust the air cap for a vertical or horizontal spray pattern, first make sure the pressure is relieved. Then loosen the air cap retaining nut, and rotate the air cap as directed in Fig. 5. T ighten the retaining nut until the air cap is hel ...

  • Graco Inc. 223451 - page 16

    16 308018 Operation Shutdown W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of an injury , follow the Pressure Relief Procedure on page 13 whenever you stop spraying and whenever you are instructed to relieve pressure. 1. Relieve the pressure. 2. Flush and clean the equipment. Follow the instruc- tion in Maintenance . Maintenance Daily C ...

  • Graco Inc. 223451 - page 17

    308018 17 Maintenance Clean the Air Cap and Fluid Nozzle CAUTION Do not use metal tools to clean the air cap or spray tip holes as this could scratch them, and make sure the electrode wire is not damaged. Scratches in the air cap or spray tip or a damaged electrode wire can distort the spray pattern. Equipment needed:  Soft bristle brush  Com ...

  • Graco Inc. 223451 - page 18

    18 308018 T roubleshooting W ARNING ELECTRIC SHOCK HAZARD Installing and servicing this equipment requires access to parts which may cause an electric shock or other serious injury if the work is not performed properly . Do not install or service this equipment unless you are trained and qualified. W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce t ...

  • Graco Inc. 223451 - page 19

    308018 19 T roubleshooting Gun Operation T roubleshooting Problem Cause Solution Fluid leakage from the fluid packing area The needle packings or shaft are worn. Replace the packings or shaft; see page 28. The packing nut is loose Tighten the packing nut; see page 28. Air leakage from the front of the gun The air valve is not seating properly . Cle ...

  • Graco Inc. 223451 - page 20

    20 308018 T roubleshooting Electrical T roubleshooting Problem Cause Solution Poor wrap-around The ES ON-OFF lever is in the OFF (O) position.* Turn the lever to ON (1). The distance between the gun and work- piece is incorrect. Adjust the spraying distance to 8 to 12 inches (203 to 305 mm) The parts are poorly grounded. Clean the workpiece hangers ...

  • Graco Inc. 223451 - page 21

    308018 21 Electrical T ests The performance and safety of the spray gun are directly affected by the condition of the electrical components contained inside the gun. The electrical tests below can be used to determine the condition of the power supply (18) and the resistor stud (22) as well as the continuity of the electrical path between the compo ...

  • Graco Inc. 223451 - page 22

    22 308018 Electrical T ests T est Power Supply Resistance Remove the power cartridge (18) from the gun handle. See Power Cartridge Replacement on page 29. Remove the turbine alternator from the power car- tridge. See T urbine Alternator Removal on page 30. Measure the resistance from the power supply ’ s ground contact point (EE) to the contact s ...

  • Graco Inc. 223451 - page 23

    308018 23 Electrical T ests T est Resistor Stud Resistance (continued) If the resistance is outside the specified range, remove the resistor stud (22). See Air Cap/Nozzle/Resistor Stud Replacement on page 24. Check the resistance between the black resistor stud contact ring (D) and the needle contact ring (E). Refer to Fig. 10. Y ou may have to pre ...

  • Graco Inc. 223451 - page 24

    24 308018 Service Prepare the Gun for Service W ARNING ELECTRIC SHOCK HAZARD Installing and servicing this equipment requires access to parts that may cause electric shock or other serious injury if the work is not performed properly . Do not install or service this equipment unless you are trained and qualified. W ARNING PRESSURIZED EQUIPMENT HAZA ...

  • Graco Inc. 223451 - page 25

    308018 25 Service Air Cap/Nozzle/Resistor Stud Replacement (continued) 6. T rigger the gun while installing the fluid nozzle (21) and resistor stud (22) assembly with the multi-tool (62). Tighten until the fluid nozzle seats in the gun barrel. 7. Install the air cap assembly (1, 2, 8). T est the gun resistance as instructed on page 21. 06449 Fig. 1 ...

  • Graco Inc. 223451 - page 26

    26 308018 Service Barrel Removal 1. Prepare the gun for service as instructed on page 24. 2. Carefully loosen the nut (14) from the bracket/fluid fitting (16). Pull the tube (12) out of the fitting. Make sure both ferrules and the nut stay with the tube. See Fig. 14. 3. Using the wrench (63) supplied, loosen the three socket head cap screws (5). 4. ...

  • Graco Inc. 223451 - page 27

    308018 27 Service Fluid Packing Removal 1. Prepare the gun for service as instructed on page 24. 2. Remove the air cap assembly , fluid nozzle and resistor stud, and electrode as instructed on page 25. 3. Loosen the trigger screws (4) far enough to re- move the trigger (13). 4. Remove the packing cartridge and needle assem- bly (28), using the mult ...

  • Graco Inc. 223451 - page 28

    28 308018 Service Fluid Packing and Needle Repair The fluid packings and needle can be replaced as individual parts or as assemblies. The overall assem- bly is pre-adjusted at the factory . NOTE: Before installing the packing and needle as- sembly into the gun barrel, make sure the internal surfaces of the barrel are clean. Remove any residue with ...

  • Graco Inc. 223451 - page 29

    308018 29 Service 06629 Fig. 18 7 35 37a 37b 18b 18c 18a 18 18d 37 F   Apply a very light coat of lubricant  Do not expose to solvents  Power Cartridge Replacement NOTE: The power cartridge consists of the alternator (37), power supply (18) and retaining ring (35). See Fig. 18. 1. Prepare the gun for service as instructed on page 24. 2. ...

  • Graco Inc. 223451 - page 30

    30 308018 Service T urbine Alternator Replacement NOTE: Replace turbine bearings after 2,000 hours of operation. See your authorized Graco distributor . 1. Prepare the gun for service as instructed on page 24. 2. Remove the power cartridge from the gun handle as instructed on page 29. 3. Squeeze the two ends of the retaining ring (35) together and ...

  • Graco Inc. 223451 - page 31

    308018 31 Service Fan Air Adjustment V alve Repair 1. Prepare the gun for service as instructed on page 24. 2. Place a wrench on the flats of the valve housing and remove it from the handle. See Fig. 20. NOTE: The fan air valve (43) can be replaced as an assembly or as individual parts. T o disassemble the fan valve: 3. Remove the retaining ring (4 ...

  • Graco Inc. 223451 - page 32

    32 308018 Service Fluid Adjustment Assembly Repair 1. Prepare the gun for service as instructed on page 24. 2. Using a 14 mm socket wrench, remove the fluid adjustment assembly (45). See Fig. 21. 3. T urn the stem (45a) fully clockwise and remove the sleeve stop (45e). 4. T o completely disassemble the fluid adjustment assembly , the sleeve stop (4 ...

  • Graco Inc. 223451 - page 33

    308018 33 Service Air T rigger V alve Repair 1. Prepare the gun for service as instructed on page 24. 2. Using a 14 mm socket wrench, remove the fluid adjustment assembly (45), o-ring (23) and spring (44). See Fig. 21. CAUTION Clean all parts in non-conductive solvent compatible with the fluid being used, such as xylol or mineral spirits. Use of co ...

  • Graco Inc. 223451 - page 34

    34 308018 Service ES ON-OFF V alve Repair 1. Prepare the gun for service as instructed on page 24. 2. Loosen the set screw (24) with the 2 mm hex key (69) provided. Remove the lever (26) from the valve. See Fig. 23. W ARNING MOVING P ARTS HAZARD T o reduce the risk of eye injury , be sure to wear safety glasses when removing or installing the retai ...

  • Graco Inc. 223451 - page 35

    308018 35 Service T ube and Shroud Removal/Replacement 1. Prepare the gun for service as instructed on page 24. 2. Remove the air cap, nozzle and resistor stud, and electrode as instructed on page 29. 3. Loosen the nut (14) and disconnect the fluid tube (12) from the bracket/fluid fitting (16). See the Parts Drawing on page 36. 4. Remove the trigge ...

  • Graco Inc. 223451 - page 36

    36 308018 Parts 06614 6 7 4 13 3 1 8 2 22 20 21 25 35 34* 44 45d 23* 39 40 42* 66 17 15 19 33 12 10 24 26 36 47 32 31 12d 16 37a* 37b 18a* 18c 18b* 30 5 18d 19* See Detail A 67 28a 43b 43d 43e* 43c 18f 18e 12c REF . 16 12a 12b 12e DET AIL A 28g 28b 28d 28e 28f 28c 28h 46 38 41* 28 Item 12 includes items 12a to 12e Item 18 includes items 18a to 18f ...

  • Graco Inc. 223451 - page 37

    308018 37 Parts W ARNING Some PRO 3500hc Gun replacement parts look similar to other PRO Gun parts but are not interchangeable! When servicing, do not mix or use other PRO Gun parts! Use of parts other than those specified in the parts list below could alter the grounding continuity of the gun, cause parts to leak or rupture, or cause the gun to ma ...

  • Graco Inc. 223451 - page 38

    38 308018 Parts Part No. 223451 Conversion Kit Kit must be purchased separately . Ref No. Part No. Description Qty Ref No. Part No. Description Qty 10 186102 SHROUD 1 12 223450 TUBE, fluid Includes items 12a – 12e 1 12a 1 1 1450  O-RING; fluoroelastomer 1 12b 1 10749  O-RING; fluoroelastomer 1 12c 1 10079  NUT , fluid tube 1 12d 1 10077 ...

  • Graco Inc. 223451 - page 39

    308018 39 Accessories Use Only Genuine Graco Parts and Accessories AIR LINE ACCESSORIES Conductive Air Supply Hose; black 100 psi (7 bar , 0.7 MPa) Maximum Working Pressure FM Approved; Color coded black; 0.315 in. (8 mm) ID; 1/4 npsm(f) x 1/4 npsm(f) left-hand thread 220444 6 ft (1.8 m) 218100 15 ft (5 m) 218101 25 ft (8 m) 218102 36 ft (1 1 m) 21 ...

  • Graco Inc. 223451 - page 40

    40 308018 Accessories Use Only Genuine Graco Parts and Accessories FLUID LINE ACCESSORIES Fluid Hose Assemblies (Nylon) 225 psi (14 bar , 1.4 MPa) Maximum Working Pressure FM Approved; 1/4 in. (6.35 mm) ID, 3/8 npsm(fbe) 215637 25 ft (8 m) 215638 50 ft (15 m) Fluid Hose Assemblies (Nylon) 500 psi (35 bar , 3.5 MPa) Maximum Working Pressure FM Appro ...

  • Graco Inc. 223451 - page 41

    308018 41 T echnical Data Category Data Gun Weight 1.89 lb (0.86 kg) Gun Length 9.5 in. (240 mm) Maximum Working Pressure 100 psi (7 bar , 0.7 MPa) Air Pressure Operating Range 0 – 100 psi (0 – 7 bar , 0 – 0.7 MPa) Fluid Pressure Operating Range 0 – 100 psi (0 – 7 bar , 0 – 0.7 MPa) V oltage Output 0 – 65 kV Paint Resistivity Range 3 ...

  • Graco Inc. 223451 - page 42

    42 308018 Notes ...

  • Graco Inc. 223451 - page 43

    308018 43 Notes ...

  • Graco Inc. 223451 - page 44

    44 308018 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended , or limited warranty published by Graco, Graco will, for ...

Manufacturer Graco Inc. Category Paint Sprayer

Documents that we receive from a manufacturer of a Graco Inc. 223451 can be divided into several groups. They are, among others:
- Graco Inc. technical drawings
- 223451 manuals
- Graco Inc. product data sheets
- information booklets
- or energy labels Graco Inc. 223451
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco Inc. 223451.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco Inc. 223451, service manual, brief instructions and user manuals Graco Inc. 223451. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco Inc. 223451.

Similar manuals

A complete manual for the device Graco Inc. 223451, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco Inc. 223451 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco Inc. 223451.

A complete Graco Inc. manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco Inc. 223451 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco Inc. 223451, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco Inc. 223451, that we can find in the current document
3. Tips how to use the basic functions of the device Graco Inc. 223451 - which should help us in our first steps of using Graco Inc. 223451
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco Inc. 223451
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco Inc. 223451 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco Inc. 223451?

Use the form below

If you did not solve your problem by using a manual Graco Inc. 223451, ask a question using the form below. If a user had a similar problem with Graco Inc. 223451 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)