Manual Enerco HST45

24 pages 1.16 mb
Download

Go to site of 24

Summary
  • Enerco HST45 - page 1

    0 1/05 R evi sio n L1 #0 28 5 3 Ene rco G roup, Inc., 4560 W. 1 6 0TH ST . , CLEV EL AND, O HIO 4 4 1 3 5 • 2 1 6-9 1 6-300 0 I m pr o p e r i n st a l l at i o n , a d ju s t me nt , al t e ra ti o n , s e rv ic e or ma in t e na nc e ca n c a u se in ju ry or pr op erty da ma ge . R e f er to th is ma nu al . F or a s s i st a nc e or a d d i t ...

  • Enerco HST45 - page 2

    2 | G as-F ired L ow-Intens ity Infrar ed Heater Ope r ating In stru cti ons an d Owne r’s Ma nual W AR N I NG : FIRE, BURN, INHAL A TION, AND EXPL OSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH A S BUILDING MA TER IALS, P AP ER OR CARDBO A RD, A S A FE DIS- T ANCE A W A Y FR OM THE HEA TER AS RE C OMMEN DED B Y THE INSTR UCTIONS NEVER USE THE HEA T ...

  • Enerco HST45 - page 3

    3 Ope ra ting Instr ucti ons and Own er’s Manual | Gas-F ired L ow-Intensi ty Infrared Heater B E FO RE Y OU BE G I N R ead this manual carefully befor e installing or servicing this equipme n t. Improper installa tion, ser vicing or maintenance will cause death, injur y or proper ty dama ge. Check the min imum requir ed safe distances from combu ...

  • Enerco HST45 - page 4

    4 En erco G roup, Inc., | Gas-F ired L ow-I n tens ity Infrar ed Heater Ope ra ting Instr ucti ons and Own er’s Manual - R ea r V ie w - R ear Movable Hange r He at E x ch ange r R e flecto r Fr ont Fixed Ha nger A b ou t T he H e a te r B urner Bo x Co ntrol Si de Acces s B urner Box Con tains the electrical componen ts (i.e. blow er mot or , po ...

  • Enerco HST45 - page 5

    5 Ope ra ting Instr ucti ons and Own er’s Manual | G as-F ired L ow-Intensit y Infrared Hea ter Leading Particulars Model No. B TU /h r W eigh t Leng th MH T - 4 5 4 5 , 00 0 96 lbs. 1 0’ T e c h ni ca l S p e ci fi c a t i on s: - S id e V ie w - - E nd V i ew - R efl ector He a t Ex changer S uspension P oints 1" Max. 1 1 1/2 " B ur ...

  • Enerco HST45 - page 6

    6 | Gas-Fi red Lo w-Intens ity Infrar ed He ater Operating In stru ctio ns and Owne r’s Ma nual W h er e c an t h e he at e r b e i ns ta l l e d? The MHT/HST tube heater is intended for installation in the following areas : • R esidential applications, such as: — garages — greenhouses — workshops • Light industrial/commercial applicati ...

  • Enerco HST45 - page 7

    7 Ope ra ting Instr ucti ons and Own er’s Manual | G as-F ired L ow-Intensit y Infrared Hea ter A T TENTI ON Risq u e d e m ono xyde d e carbo ne L echapp ement du r adi a teur doit s’ef fectuer a l’e x terieur . Utillisez le ma teriel fourni. L e non-respect de ces co nsignes pe ut entr ain er mor t ou blessur es. V enting Codes The location ...

  • Enerco HST45 - page 8

    8 | Gas-Fi red Lo w-Intens ity Infrar ed He ater Operating In stru ctio ns and Owne r’s Ma nual S e ct io n 3 IN ST AL L A TI ON W ARNI NG Sev er a l steps are in volv ed in the inst alla tion of the hea t er . DO NO T a t t empt to opera te th e hea t er until ALL st eps of the inst alla tion hav e be en a ccomplis hed. F a ilure to f ollow this ...

  • Enerco HST45 - page 9

    9 Ope ra ting Instr ucti ons and Own er’s Manual | Gas-Fi red L ow-I n tens ity Infrared Heater It is important to keep the minimum required safe distances from combustibles at all tim es to av oid death, pe rsona l in jur y or proper ty d amage. Clearances fr om vehicles park ed beneath hea ters must be mai n tained. Signs should be posted to id ...

  • Enerco HST45 - page 10

    10 | Gas-Fi red Lo w-Intens ity Infrar ed He ater Operating In stru ctio ns and Owne r’s Ma nual H a ng th e H ea te r R esi dential garages come in a variet y of sizes, shapes, style s and methods of con struc tion . B ecause of all the se v aria bles, it is not possible to i nclud e mou n ting hardware with the MHT / HST he a ter . Although woo ...

  • Enerco HST45 - page 11

    11 Ope ra ting In str ucti ons and Own er’s Manual | Gas-F ired L ow-Intensi ty Infrared H eater M H T / H S T HE A TE R A SS EM B L Y IN ST RU C TI ON S 1 . Place gaske ts fr om Gasket kit (0 2 88 5) on each side of the burner box. Use the four mounting studs around each of the three-inch holes for location. 2. Slide the tube flanges o v er the ...

  • Enerco HST45 - page 12

    12 Ene r co Gr oup , Inc. , | Gas-Fired Lo w-Intensi ty Infrare d Heater Ope r ating In stru cti ons an d Owne r’s Ma nual Ca na di an In stal la tio ns 1 US In st al la tio ns 2 A= Clearance ab ov e g rade, 1 2 inch es (30 c m) 1 2 in ches (30 cm ) veranda, po r ch, dec k o r balco ny B= Cl earance to w indow o r do or 6 in ches (1 5 cm) for ap ...

  • Enerco HST45 - page 13

    13 Ope ra ting In str ucti ons and Own er’s Manual | G as-F ired L ow-Intensit y Infrared Hea ter The seams along the length of the piping and the joints between sections of piping should be sealed to prevent a potential lea k age of f lue gas into bui lding. Use 1 00% RTV S ilicone R ubber A dhesive sealant su itable f or 500°F . 6. All por tio ...

  • Enerco HST45 - page 14

    14 Ene r co Gr oup , Inc. , | Gas-Fired Lo w-Intensi ty Infrar ed Heater Operating Ins tru ctio ns and Owner ’s Man ual MINIMUM HEIGHT FROM R OOF T O L OWEST DISCHARGE OPENING R oof Pitch H (Min ) Fl at to 6/1 2 1 .0 Feet Over 6 /1 2 to 8/ 1 2 1 .5 Fee t Over 8/ 1 2 to 1 0 /1 2 2.5 F eet Over 1 0/1 2 to 1 2/1 2 4.0 F eet Over 1 2/1 2 to 1 6 /1 2 ...

  • Enerco HST45 - page 15

    15 Opera ting Instructions and Owner’s Manual | G as-F ired L ow-Intensit y Infrared Hea ter Double W all Double wall ven t r un a nd Double wall terminal end V erti ca l V ent in g a) Three (3") inc h O. D. f lue pipe , ma ximum twenty five (2 5') feet in length may be used as shown with approv ed vent ca p. b) An i nsulated thim ble m ...

  • Enerco HST45 - page 16

    16 | Gas-Fi red Lo w-Intens ity Infrar ed H eater Operating Instr ucti ons an d Owne r’s Manual Non-Pressurized Outside Air Supply Duct O u ts id e C om b u s ti on Ai r S up p l y The MHT / H S T tube heater is approved for installation with an outside air supply system. Some compounds such as halogenated hydrocarbons or other corrosive chemical ...

  • Enerco HST45 - page 17

    17 Ope ra ting In str ucti ons and Own er’s Manual | G as-F ired L ow-Intensi ty Infrared He a ter C A UTION Label all wires prior to disconnection when ser vi cing controls. wir ing errors can cause i mproper and danger ous oper ation. V erify pr oper opera tion after ser vicing. The appliance, when installed, must be electrically grounded in a ...

  • Enerco HST45 - page 18

    18 | Gas-Fi red Lo w-Intens ity Infrar ed He ater Operating In stru ctio ns and Owne r’s Ma nual S e ct io n 5 OP E R A TI ON Supplied by oth ers He a ter Flex Pipe when such use is in compliance with local codes. All pipe, tube and fi tt ings shou ld be n ew and free from defects . C arefully ream the pipe and tube ends to r emov e obstructions ...

  • Enerco HST45 - page 19

    19 Ope ra ting In str ucti ons and Own er’s Manual | G as-Fi red L o w-Intens ity Infrared Heater O p er a ti o n o f t h e H ea te r CHILDERN AND ADUL TS SHOULD BE ALER TED T O THE HAZARDS OF HI GH SU RF A CE TE MPER A TU RES A ND SH OULD ST A Y A W A Y T O A V OID BURNS OR CL O THING IGNITION. Y OUNG CHILDERN SHO ULD BE CAREFULL Y SUPER VISED W ...

  • Enerco HST45 - page 20

    20 | Gas-Fi red Lo w-Intens ity Infrar ed He ater Operating In stru ctio ns and Owne r’s Ma nual S e ct io n 7 TR OU BL ES H O O T I N G General This tr oubleshooting quide has been designed to assist you in locating and correcting minor problems that ma y occur with the MH T / HS T B L O W E R DO ES N O T CO ME ON Possibl e Cause T r y Thi s…. ...

  • Enerco HST45 - page 21

    21 Ope ra ting In str ucti ons and Own er’s Manual | G as-Fi red L o w-Intens ity Infrared Heater B U RN ER D O ES N O T L I G HT Possible Cause Air i n th e g as line. Imp roper gas in let p ressure. Gas valve does not op en. L ow gas out let p ressure. B U RN ER DO ES NO T S T A Y L IT Possibl e Cause D amaged wires be tween DSI module and elec ...

  • Enerco HST45 - page 22

    22 | Gas-Fir ed L o w-In tensity Infrar ed Heater Operating In stru ctio ns and Owner ’s Ma nual S e ct io n 8 IL L U S TR A TE D P ART S Illustra ted P ar ts This section pro vides the par t numbers and pictorials for compone nts of the MH T / H S T tub e heater . Callou t let ters on t he illus trat ions are keyed to the assoc iated par ts l is ...

  • Enerco HST45 - page 23

    23 Ope ra ting In str ucti ons and Own er’s Manual | Ga s-Fi red L ow-I n tens ity Infrared Heater AL L W AR RA NTY C L AI MS RE QUI R E P R OOF OF PU R CH AS E REF.# ITEM# DESCRIPTION A F 2 0 2 8 5 0 MHT-4 5NG B urner Box for (F2 088 50) F 2 0 2 8 5 1 MHT-4 5LP Burner Bo x for (F2 0 8 8 5 1) B F 1 06 2 5 0 MHT / H ST - 4 5 Tube Set C 0 6 0 1 4 H ...

  • Enerco HST45 - page 24

    24 | G as-F ired L ow-Intens ity Infrar e d Heater Operating Instr ucti ons an d Owne r’s Manual W A R N I N G : USE ONL Y MANUF A CTURER’S REPL A CEMENT P AR TS. USE OF ANY OTHER P ARTS COULD CA US E INJUR Y OR DEA T H. REPL A CEM ENT P ARTS ARE ONL Y A V AIL AB LE DIRECT FR OM THE F A CTOR Y AND MUST BE INST AL LED B Y A Q U ALIFIED SER V ICE ...

Manufacturer Enerco Category Water Heater

Documents that we receive from a manufacturer of a Enerco HST45 can be divided into several groups. They are, among others:
- Enerco technical drawings
- HST45 manuals
- Enerco product data sheets
- information booklets
- or energy labels Enerco HST45
All of them are important, but the most important information from the point of view of use of the device are in the user manual Enerco HST45.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Enerco HST45, service manual, brief instructions and user manuals Enerco HST45. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Enerco HST45.

Similar manuals

A complete manual for the device Enerco HST45, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Enerco HST45 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Enerco HST45.

A complete Enerco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Enerco HST45 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Enerco HST45, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Enerco HST45, that we can find in the current document
3. Tips how to use the basic functions of the device Enerco HST45 - which should help us in our first steps of using Enerco HST45
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Enerco HST45
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Enerco HST45 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Enerco HST45?

Use the form below

If you did not solve your problem by using a manual Enerco HST45, ask a question using the form below. If a user had a similar problem with Enerco HST45 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)