Scotsman Ice DB-101 - page 1
SCOTSMAN WOOD FURNACE Model DB - 101 O W N E R ’ S M ANUA L IMPORT ANT READ OWNER’S MANUAL THOROUGHLY BE FORE INSTALLING FURNACE OR LIGHTING FIRE. CONSULT LOCAL AUTHORITIES IF IN DOUBT ABOUT YOUR LOCAL FIRE SAFETY REGULATIONS. ALL INSTALLATIONS MUST BE MADE IN ACCORDANCE WITH LOCAL AND STATE OR PROVINCIAL CODES WHICH MAY DIFFER FROM THIS MANUAL ...
-
Scotsman Ice DB-101 - page 2
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 1 TABLE OF CONTENTS Specifications 2 1.0 Operating Instructions 3 1.1 Introduction 3 1.2 Wood - Burning 3 1.3 Storage of Wood 4 1.4 Maximum Solid - Fuel Charge 5 1.5 Maintenance 5 1.5.1 Cleaning 5 1.5.2 Servicing 6 1.6 Safety 6 1.7 Controls 6 1.8 Electrical Power Failure 7 1.9 Homeown ...
-
Scotsman Ice DB-101 - page 3
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 2 KERR SCOTSMAN Wood Furnace Model DB - 101 - ADD Tested and Listed by: Energy Testing Laborat ory of Maine Certified by the Canadian Standards Association (CSA) Sept. 1981 COSP No. WCP 001 – Free - Standing COSP No. WCP 005 – Add - On Manufactured by: Parrsboro Metal Fabricators ...
-
Scotsman Ice DB-101 - page 4
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 3 1.0 OPERATING INSTRUCTIONS 1.1 INTRODUCTION Congratulations on your purchase of the KERR SCOTSMA N Wood Furnace. Developed in Atlantic Canada, this KERR Furnace has been designed to allow you to heat your home with wood, one of North America’s most abundant fuels. Designed with yo ...
-
Scotsman Ice DB-101 - page 5
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 4 CREOSOTE Wood combustion is never 100% complete. Wood smoke always contains some unburned gases and a mixture of unburned tar - like liquids. A percent age of these materials will condense out on any cool surface, leaving a dark brown or black substance with an unpleasant acrid odor ...
-
Scotsman Ice DB-101 - page 6
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 5 1.4 MAXIMUM SOLID - FUEL CHARGE The maximum level for a solid - fuel charge is the middle of th e loading door, or the level of the handle. DO NOT OVERFILL. The KERR SCOTSMAN Wood Furnace will accept whole or split logs up to 34 in. (865 mm) long, but a 30 in. (765 mm) log length is ...
-
Scotsman Ice DB-101 - page 7
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 6 DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non - combustible floor or on the ground, well away from all combustible materials, p ending final disposal. If the ashes are disposed of by bu ...
-
Scotsman Ice DB-101 - page 8
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 7 1.8 ELECTRICAL POWER FAILURE (Fig S101 - 3) If no one is home during a power failure, the damper will automatically close and some gravity heating will take place. Combustion air will continue to enter through the secondary air holes and a fire should be maintained. IMPORTANT – Th ...
-
Scotsman Ice DB-101 - page 9
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 8 1.9 HOMEOWNER CHECKLIST o Keep area around unit clean and clear of combustibles. o Use only dry wood. DO NOT burn garbage, gasoline or naphtha. o Load carefully. o Remove ashes as directed. o Watch for soot build up in smoke pipe – clean regularly. o Clean furnace heat exchanger r ...
-
Scotsman Ice DB-101 - page 10
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 9 2.2 UNCRATING When you receive your KERR SCOTSMAN Wood Furnace, check it carefully to ensure that all components are pr esent and in good condition. If there has been any damage or loss in transportation, please notify the carrier and retailer at once. Inspect for the following: o F ...
-
Scotsman Ice DB-101 - page 11
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 10 2.4.1 COMBUSTION AIR SUPPLY Air inlets of at least 200 square inches free area (1.5 in 2 /1000Btu) must be provided to the room occupied by the wood fired or oil fired furnace. These fresh air inlets must provide or allow free access of fresh outside air to the furnace. At no time ...
-
Scotsman Ice DB-101 - page 12
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 11 Connect only to a flue or chimney capable of maintaining a negative draft of .05” wc at all times and conditions. WARNING: If this setting is exceeded it could cause a solid fuel fire to burn out of control. We recommend tha t the KERR SCOTSMAN Wood Furnace be connected to its ow ...
-
Scotsman Ice DB-101 - page 13
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 12 2.5 CLEARANCES (Fig S101 - 1) The KERR SCOTSMAN Wood Furnace is to be installed in accordance with National Building Code or local regulations. Allowances front and rear must be made for cleaning and servicing. NOTE: Regardless of minimum clearances to combustibles for safet y reas ...
-
Scotsman Ice DB-101 - page 14
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 13 2.6.1 FREE - STANDING (Fig S101 - 9) The KERR SCOTSMAN Wood Furnace in the free standing (stand - alone) system, is the sole source of central heating using an optional blower box kit to circulate the air. In this system connect the ductwork, as you would for any conventional warm ...
-
Scotsman Ice DB-101 - page 15
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 14 The blue h eating wire from the wood fan limit control on high speed. This relay will disconnect the circulation fan low speed switch and connect the high speed to the blower motor when there is a call for heat. Items required : o Switching Relay R4222D 1013 (120 V Co il, 12 amp @ ...
-
Scotsman Ice DB-101 - page 16
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 15 2.7 DUCT CONNECTION (Fig S101 - 5, Fig S101 - 1) See figure S101 - 12 for Approved Furnace Ductwork Configurations. See figure S101 - 13 for Prohibited Furnace Ductwork Configurations. The use of A/C coils is not recommended unless special arrangements are made. Minimum cross - sec ...
-
Scotsman Ice DB-101 - page 17
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 16 Pressure may be corrected by the following m easures: 1) Change blower pulley size (usually decrease) 2) Change blower motor pulley (usually increase) 3) Increase return air duct area (if restricted) CAUTION – Current draw by blower motor should be checked after making any pulley ...
-
Scotsman Ice DB-101 - page 18
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 17 M847 – Damper Motor The damper door lever should be attached to the damper motor wheel with the chain included. Be sure the damper door is fully closed and the dampe r motor is not powered. Connect the chain to the damper door level and to the bottom hole in the damper motor whee ...
-
Scotsman Ice DB-101 - page 19
SCOTSMAN WOOD FURNAC E – INSTRUCTION MANU AL Scotsman Oct - 06 18 ADDENDUM FOR OIL FURN ACES HAVING M ULTI - SPEED BLOWERS WITH CONTINUOUS CIRCUL ATION CAPABILITY . Add - on furnaces such as the Kerr Scotsman and Scotty SS can be installed with oil fired warm air furnaces such as the Kerr KD Gemini that have continuous blower circulation capabili ...
-
Scotsman Ice DB-101 - page 20
...
-
Scotsman Ice DB-101 - page 21
...
-
Scotsman Ice DB-101 - page 22
...
-
Scotsman Ice DB-101 - page 23
...
-
Scotsman Ice DB-101 - page 24
...
-
Scotsman Ice DB-101 - page 25
...
-
Scotsman Ice DB-101 - page 26
...
-
Scotsman Ice DB-101 - page 27
...
-
Scotsman Ice DB-101 - page 28
...
-
Scotsman Ice DB-101 - page 29
...
-
Scotsman Ice DB-101 - page 30
...
-
Scotsman Ice DB-101 - page 31
...
-
Scotsman Ice DB-101 - page 32
...
-
Scotsman Ice DB-101 - page 33
Terms and Conditions of Warranty 1) The warranty is not assignable and rights pursuant to it are given only to the original purchaser of the furnace from an authorized retailer. 2) The warranty is null and void unless the original purchaser fully completes th e warranty registration card and the card is received by Kerr Heating Products within 30 ( ...
-
Scotsman Ice DB-101 - page 34
ATTENTION HEATING CONTRACTOR : THIS WARRANTY IS FOR THE ORIGINAL PURCHASER AND SHOULD BE GIVEN TO HIM/HER OR PLACED IN SIGHT NEAR THE WOOD FURNACE. SCOTSMAN WOOD FURNACE 5 YEAR WARRANTY Subject to the terms and conditions on the reverse side hereof Kerr Heating Products (hereinafter called “Kerr”) warrants as follows: The heat exchanger of the ...
Do you have a question concerning Scotsman Ice DB-101?
Use the form below
If you did not solve your problem by using a manual Scotsman Ice DB-101, ask a question using the form below. If a user had a similar problem with Scotsman Ice DB-101 it is likely that he will want to share the way to solve it.