Manual Rinnai RL94E

60 pages 1.34 mb
Download

Go to site of 60

Summary
  • Rinnai RL94E - page 1

    — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of th is or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical s witch; do not use any phone in your building. • Immediately call y our gas supp lier from a neighbor’s phone. Follow the ...

  • Rinnai RL94E - page 2

    2 VB Series Outdoor LS Manual Specifications ..................................................... 3 Consumer Safety Information Safety Definitions ............................................. 4 Safety Behaviors and Practices ....................... 4 Safety Features ............................................... 4 Description of Operation ...... ...

  • Rinnai RL94E - page 3

    VB Series Outdoor LS Manual 3 Specifications Model RL75e RL94e R98LSe R98LSe-ASME Minimum Gas Consumption Btu/h 9,900 (NG) 10,300 (LPG) 19,000 Maximum Gas Consumption Btu/h 180,000 199,000 237,000 Hot water capacity (Min - Max) * 0.4 - 7.5 GPM (1.5 - 28.5 L/min) 0.4 - 9.4 GPM (1.5 - 35.5 L/min) 0.6 - 9.8 GPM (2.3 - 37 L/min) Hot water capacity (45? ...

  • Rinnai RL94E - page 4

    4 VB Series Outdoor LS Manual W ARNING Safety Behavior and Practices • Keep the area around the appliance clear and free from combustible materials, gasolin e, and other flammable vapors and liquids. • Do not use this appliance if any part has been u nder water. Immediately call a qualified service technician to inspect the applian ce and to re ...

  • Rinnai RL94E - page 5

    VB Series Outdoor LS Manual 5 The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous supply of hot water at a preset temperature. This appliance is a direct vent appliance where air is brought in from the outside and com bustion gases are exhausted to the outside. While electricity, water, and gas sup ...

  • Rinnai RL94E - page 6

    6 VB Series Outdoor LS Manual T emperature Controller MC-91-1US & MCC-91-1US The MC-91 controller is the standard temperature controller that is supplied with the water heater. On indo or models it is integrated into the front panel . The MCC-91 controller is for commercial and hydronic applications requiring higher temperatu res. When the MCC- ...

  • Rinnai RL94E - page 7

    VB Series Outdoor LS Manual 7 How to Set the T emperature DANGER Hot water can be dangero us, especially for infants or children, the elderly, or infirm. There is hot water scald pote ntial if the thermostat is set too high. Water temperatures over 125º F (51 º C) can cause se vere burns or scalding resulting in death. Hot water can cause first d ...

  • Rinnai RL94E - page 8

    8 VB Series Outdoor LS Manual Setting the Sound V olume (V oice Prompt) BC-100V Press the “Sound Vol.” button to adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the button cycles through the volume levels in the order below. MC-100V Press the “Function” button to adjust the voice prompt vo ...

  • Rinnai RL94E - page 9

    VB Series Outdoor LS Manual 9 Using the Water Smart / Bath Fill Function Overview This function is exclusive to the BC-100V temperatu re controller. The bath fill f unction allows the consumer to fill a tub with a preset volume of water at a preset temperature. This is done by pressing the bath fill button on the BC-100V cont roller while no hot wa ...

  • Rinnai RL94E - page 10

    10 VB Series Outdoor LS Manual Setting Controller to Mute To eliminate the beeps wh en keys are pressed or to turn the beeps back on, pre ss and hold both the ▲ and ▼ buttons until a beep is heard (approxim ately 5 seconds). Models MC-91 and MCC-91 Filling the Tub Using the Water Smart / Bath Fill Function Setting the Clock MC-100V Press the ? ...

  • Rinnai RL94E - page 11

    VB Series Outdoor LS Manual 11 W ARNING Turn off the electrical power sup ply, the manual gas valve and the manual water control valve whenever servicing the unit. Repairs and maintenance should be p erformed by a qualified service technician. The appliance should be inspected annually by a qualified service technicia n. Verify proper operation aft ...

  • Rinnai RL94E - page 12

    12 VB Series Outdoor LS Manual Error Codes The Rinnai water heater has the ability to check its o wn op eration continuously. If a fault occurs, an error cod e will flash on the display of the temperature controller. This assists with diagno sing the fault and may enable you to overcome a problem wit hout a service call. Please i dentify the code d ...

  • Rinnai RL94E - page 13

    VB Series Outdoor LS Manual 13 Error Codes Code Fault Remedy 16 Over Temperature Warning Check for restrictions in air flow around unit and vent terminal. Check for low water flow in a circul ating sy stem causing short-cycling. Check for foreign materials in com bustion chamber and/or exhaust piping. Check for clogged heat exchanger. 32 Outgoing W ...

  • Rinnai RL94E - page 14

    14 VB Series Outdoor LS Manual T rouble Shooting for Common Issues I don’t have any hot w a ter when I open the tap. Make sure there is gas, water, and ele c tricity to the Rinnai water heater (powe r is turn ed on and the gas is turned on). When I was using the hot w a ter, the water got cold. If you adjusted the flow from the tap to lessen it, ...

  • Rinnai RL94E - page 15

    VB Series Outdoor LS Manual 15 Wa ter Hea ter Pressure R el ief Valve 3/4" Ball Valve 3/4" Union Check Valve S Pressure Regulator Circulatin g Pump Solenoi d Valve Boiler Dr ain Valve KEY G a s S u p p l y V1 V3 V2 V4 H1 H2 H3 Circulating Pump C o l d W a t e r L i n e H o t W a t e r L i n e n - l i n e F i l t e r I Rinnai Flushing the ...

  • Rinnai RL94E - page 16

    16 VB Series Outdoor LS Manual Only properly trained and q ualified installers should install this appliance. The warran ty may be voided due to improper installation or installation by a non-qualified installer. Rinnai highly recommends all installers a ttend a product knowledge cla ss. For information on a Rinn ai Training Course or for questions ...

  • Rinnai RL94E - page 17

    VB Series Outdoor LS Manual 17 Clearances from Appliance 1. Identify the installati on lo cation and confirm that the installation will meet all required clea rances. 2. Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachmen ...

  • Rinnai RL94E - page 18

    18 VB Series Outdoor LS Manual G a s P i p i n g General Instructions • A manual gas control valve must be placed in the gas supply line to the Rinnai water heat er. A union can be used on the connection ab ove the shut off valve for the future servicing or disconnection of the unit. • Check the type of gas and the gas inlet pressu re before co ...

  • Rinnai RL94E - page 19

    VB Series Outdoor LS Manual 19 Pipe Sizing Procedure - Example Pipe Size (inches) 3/4 1 1 1/4 1 1/2 10 273 514 1060 1580 20 188 353 726 1090 30 151 284 583 873 40 129 243 499 747 50 114 215 442 662 60 104 195 400 600 70 95 179 368 552 80 89 167 343 514 90 83 157 322 482 100 79 148 304 455 125 70 131 269 403 150 63 119 244 366 175 58 109 224 336 200 ...

  • Rinnai RL94E - page 20

    20 VB Series Outdoor LS Manual Isolation Valves and Pressure Relief Valve (RL75e and RL94e) W ater Piping The isolation valves provid e the ability to isolate the water heater from the stru cture’s plumbing and allow quick access to flush the heat exchanger. Che ck with local codes to determine if a pressure an d temperature relief valve is requi ...

  • Rinnai RL94E - page 21

    VB Series Outdoor LS Manual 21 The freeze protection features inclu de electrical heating elements. Freeze protection may be disabled if electricity is not suppli ed, or if there is an error preventing the water heater from functioning. Loss of freeze protection may result in water da mage from a burst heat exchanger or water lines. The installatio ...

  • Rinnai RL94E - page 22

    22 VB Series Outdoor LS Manual If the water heater is not going to be used duri ng a period of possible freezing weather, it is recomme nded that the water inside the water heat er be drained. Freeze Protection Manual draining of the water heater W ARNING To avoid burns, wait until the equipment cool s do wn before draining the water. The water in ...

  • Rinnai RL94E - page 23

    VB Series Outdoor LS Manual 23 Pressure Relief Valve 3/4" Ball Valve 3/4" Union Check Valve S Pressure Regula tor Circulating Pump Solenoid Valve Boiler Drain Va lve KEY G a s S u p p l y M i n i m u m 3 / 4 " C o l d W a t e r S u p p l y L i n e Minim um 3 /4" H ot Wat er Supply Line S 1/2" Minimum Normally Open Solenoid ...

  • Rinnai RL94E - page 24

    24 VB Series Outdoor LS Manual Recommended Piping for Basic Installation G a s S u p p l y 3 / 4 " C o l d W a t e r S u p p l y L i n e 3/4" Ho t Wat e r Su pply Line Rinnai Water Hea ter Rinna i Equipment Lis t Rinna i Wate r Heat ers RIK-KIT ( Optional) (3/ 4" F i tti ng s Inc l ude: 2 Union s, 2 Ball Val ves, 2D r a i n V a l v e ...

  • Rinnai RL94E - page 25

    VB Series Outdoor LS Manual 25 Recommended Piping for Circulation Systems Pressure R elief Valve 3/4" Ball Va lve 3/4" Union Check Valve S Pressure Regula tor Circu lating Pump Soleno id Valve Boiler Drain Va lve KEY Minimum 3/4" Cold Water Supply Line Electric Water Heate r Build ing Fixture s Buildi ng Supp ly E x p a n s i o n T a ...

  • Rinnai RL94E - page 26

    26 VB Series Outdoor LS Manual Flue T erminal Clearances ( ANS Z21.10.3, CSA 4.3) FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B I M C F B B E D L G A H K VENT TERMINAL AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED ...

  • Rinnai RL94E - page 27

    VB Series Outdoor LS Manual 27 Ref Description Canadian Installations US Installations A Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) B Clearance to window or door that may be opened 36 inches (91 cm) 12 inches (30 cm) C Clearance to permanently closed window * * D Vertical clearance to ventilated soff ...

  • Rinnai RL94E - page 28

    28 VB Series Outdoor LS Manual Additional Clearances Local codes supersede the se clearances. • Avoid termination locations near a dryer vent. • Avoid termination locations near commercial cooking exhaust. 2" 36" 12" INSIDE CORNER * (0.30 m) to an inside corner (50 mm) between Rinnai terminal s at same level (0.91 m) to ventilate ...

  • Rinnai RL94E - page 29

    VB Series Outdoor LS Manual 29 High Altitude Installations 0-2000 ft (0-610 m) 2001-5200 ft (610-1585 m) 5201-7700 ft (1585-2347 m) 7701-10200 ft (2347-3109 m) Switch No. 2 OFF OFF ON ON Switch No. 3 OFF ON OFF ON Set dip switches 2 and 3 to the values shown in table below for your altitude. The default setting for the appliance is 0-2000 ft (0-610 ...

  • Rinnai RL94E - page 30

    30 VB Series Outdoor LS Manual The conversion shall be carried out by a manufacturer’s authorized rep - resentative, in ac cordance with the requirements of the manufa cturer, provincial or territorial authorities having jurisdiction and in accord ance with the requirements of the CAN/ CGA-B149.1 or CAN/CGA-B149.2 Installation Codes / La conversi ...

  • Rinnai RL94E - page 31

    VB Series Outdoor LS Manual 31 T emperature Controller Installation • The controller should be out of reach of small children. • Avoid locations where the controller may become hot (near the oven or radiant heater). • Avoid locations in direct sunlight. The digital display may be difficult to read in direct sunlight. • Avoid locations where ...

  • Rinnai RL94E - page 32

    32 VB Series Outdoor LS Manual T emperature Controller Installation 1. Determine a suitable location for the controller. 2. Make three holes in the wall as shown. 3. Run the cable between the controller and the Rinnai water heater or the controlle r and the other controller. 4. Remove the face plate from the temperature controller using a screwd ri ...

  • Rinnai RL94E - page 33

    VB Series Outdoor LS Manual 33 Operating Instructions FOR YOUR SAFETY READ BEFORE OPERA TING A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the bur ner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the flo ...

  • Rinnai RL94E - page 34

    34 VB Series Outdoor LS Manual 0 10 20 30 40 50 60 70 80 90 100 0 5 10 15 20 25 30 35 40 45 0 2 4 6 8 10 12 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 0 2 55 07 5 1 0 0 1 2 5 1 5 0 T echnical Data Pressure Drop Curve Outlet Flow Data R98LSe RL94e RL75e Pressure Loss (psi) Water Flow (gpm) delta T - Temperature Rise (ºF) Pressure Loss (ft head) R ...

  • Rinnai RL94E - page 35

    VB Series Outdoor LS Manual 35 Space Heating If the water heater is to be used for both water (potable) heating and space heati ng then the following apply. • The piping and components co nnected to the water heat er shall be suitable for use with potable water. • Toxic chemicals, such as used for boiler treatment, shall not be introduced into ...

  • Rinnai RL94E - page 36

    36 VB Series Outdoor LS Manual D i m e n s i o n s DIM DESCRIPTION RL75e RL94e in (mm) R98LSe R98L Se-ASME in (mm) A Width 14 (35 5.6) 18.5 (470) B Depth 9.9 (251.1) 9.3 (230.5) C Height - Unit 22.9 (582) 23.6 (600) D Height - with brackets 25.0 (634.2) 25.2 (640) E Hot Water Outlet - from wall 3.8 (97.6) 4.5 (115) F Hot Water Outlet - from center ...

  • Rinnai RL94E - page 37

    VB Series Outdoor LS Manual 37 Ladder Diagram (for RL75e and RL94e) ...

  • Rinnai RL94E - page 38

    38 VB Series Outdoor LS Manual Ladder Diagram (for R98LSe and R98LSe-ASME) RELAY 1 IG FROST SENSI NG SWI TCH ANT I- FR OST HEA TER IG N IT ION COMB USTI ON FA N 3A ( F U SE ) HOT NE UTR AL VA R I S TOR DC1 2.6V SOLENO ID D R IV IN G CI RC U I T CP U CENT RAL PR OC ES SIN G UNIT FA N REMOTE CONTROLLER POV FA N CONTROL CI RCUI T BY - PASS FLO W CONTR ...

  • Rinnai RL94E - page 39

    VB Series Outdoor LS Manual 39 What is covered? This Warranty covers any defects in materials or w orkmanship when the product is insta lled and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warrant y document . This Warranty appl ies only to products that are installed correctly. Improper ...

  • Rinnai RL94E - page 40

    40 VB Series Outdoor LS Manual What will Rinnai do? Rinnai will repair or replace the covere d product or any part or co mponent that is defective in materials or workmanship as set forth. Rinnai will pay reasonable l abor charges associated with t he repair or replacement of any such part or component. All repair parts must be genuine Rinnai parts ...

  • Rinnai RL94E - page 41

    VB Series Outdoor LS Manual 41 NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or lice nsed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must no t install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5. 00) For all side wall horizon ...

  • Rinnai RL94E - page 42

    42 Manuel – Chauffe-eau d’ex térieur série VB LS — Ne pas entreposer ni utiliser d'essence ou ni d'autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil. — QUE F AIRE SI VOUS SENTEZ UNE ODEUR DE GAZ • Ne pas tenter d'allumer d'appareil. • Ne touchez à aucun interrupteur ; ...

  • Rinnai RL94E - page 43

    Manuel – Chauffe-eau d’ex térieur série VB LS 43 Comportements et pratiques de sécurité Réglage de température Instructions d'utilisation A VERTISSEMENT • Gardez la zone autour de l’ap pareil dégagée et exempte de matériaux combustibles, essence et a utres vapeurs et liquides inflammables. • N’utilisez pas cet appareil s? ...

  • Rinnai RL94E - page 44

    44 Manuel – Chauffe-eau d’ex térieur série VB LS Plages de température avec un contrôleur de température Ce chauffe-eau va tenter de fournir de l'ea u chaude à températur e stable malgré les variations de débit ou qu and plus d'un robinet est ouvert. La chauffe-eau ne pe ut délivrer de l'eau qu'à une seule tempér ...

  • Rinnai RL94E - page 45

    Manuel – Chauffe-eau d’ex térieur série VB LS 45 A VERTISSEMENT Coupez l'alimentation électriq ue, et fermez l'arrivée de gaz et d'eau à leur vanne de co up ure manuelle avant toute intervention sur l'unité. Les réparations ne doivent êt re effectuées que par un technicien de service qual ifié. Cet appareil doit ê ...

  • Rinnai RL94E - page 46

    46 Manuel – Chauffe-eau d’ex térieur série VB LS Seuls des installateurs qualifié s avec une formation adéquate peuvent instal ler cet appareil. La garantie peut être annulée suite à une i nstallation incorrecte ou réalisée par un installate ur non qualifié. Rinnai recommande fortement que les installateurs suivent une classe pour la ...

  • Rinnai RL94E - page 47

    Manuel – Chauffe-eau d’ex térieur série VB LS 47 Écartements par rapport à l'appareil 1. Identifiez l'emplacement d'installation et confirmez que là les espacements requis seront respectés. 2. Fixez bien le chauffe-eau au mur en utilisant n'importe lesquels des trous de s supports d'installation murale placé s en ...

  • Rinnai RL94E - page 48

    48 Manuel – Chauffe-eau d’ex térieur série VB LS Raccordement électrique Le chauffe-eau doit être électriqueme nt relié à la terre en conformité avec les normes locale s et, en leur absence, avec la plus récente édition de la norme électrique américaine, ANS I/NFPA 70. Au Canada tout câblage électrique doi t être en conformité a ...

  • Rinnai RL94E - page 49

    Manuel – Chauffe-eau d’ex térieur série VB LS 49 Installations à haute altitude Micro-commutateur 0-2000 ft (0-610 m) 2001-5200 ft (610-1585 m) 5201-7700 ft (1585-2347 m) 7701-10200 ft (2347-3109 m) N° 2 OFF OFF ON ON N° 3 OFF ON OFF ON Switch No. F O F 8 5 7 6 4 3 ON 1 2 Switch No. F O F 8 5 7 6 4 3 ON 1 2 Switch No. F O F 8 5 7 6 4 3 ON ...

  • Rinnai RL94E - page 50

    50 Manuel – Chauffe-eau d’ex térieur série VB LS T uyauterie d'eau Valve à Bille / Valve de dégagement de pression (RL75e, RL94e) Les soupapes d'isolement offrent la poss ibilité d'isoler le chauffe-eau de la structure plomberie et de permettre un accès rapide à vider l'échange ur de chaleur. Vérifiez auprès des co ...

  • Rinnai RL94E - page 51

    Manuel – Chauffe-eau d’ex térieur série VB LS 51 T uyauterie d'eau • Une vanne manuelle d e coupure d'eau doit intercalée sur la conduite en amont sur l'arri vée d'eau au chauffe-eau Rinnai. Des raccords union peuve nt s'utiliser sur les conduites d'eau froide et d'eau chaude p our faciliter les interven ...

  • Rinnai RL94E - page 52

    52 Manuel – Chauffe-eau d’ex térieur série VB LS Espacements pour terminaisons de chemi née (ANS Z21.10.3, CSA 4.3) FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B I M C F B B E D L G A H K TERMINAISON DE VENTILATION ENTRÉE D'ALIMENTATION EN AIR ZONE NON AUTORISÉE DÉTAIL D'ANGLE INTÉRIEUR FERMETURE PERMANENTE FERMETURE ...

  • Rinnai RL94E - page 53

    Manuel – Chauffe-eau d’ex térieur série VB LS 53 Réf. Description Installations Canada Installations USA A Dégagement au-dessus de niveau, véranda, porche, plate-forme ou balcon 12 po (30 cm ) 12 po (30 cm ) B Dégagement par rapport à porte ou fenêtre pouvant être ouverte 36 po (91 cm ) 12 po (30 cm ) C Dégagement par rapport à fenê ...

  • Rinnai RL94E - page 54

    54 Manuel – Chauffe-eau d’ex térieur série VB LS T uyauterie recommandée pour installation de base G a s S u p p l y 3 / 4 " C o l d W a t e r S u p p l y L i n e 3/4" Ho t Wa te r Supp ly Line Rinnai Water Heater Rinna i Equipment Lis t Rinnai Wa ter Heat ers RIK-K IT ( Op tional) (3 /4" F itting s Inc l ude : 2 Union s, 2 Ba ...

  • Rinnai RL94E - page 55

    Manuel – Chauffe-eau d’ex térieur série VB LS 55 Instructions d'utilisation À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ A. Cet appareil ne comporte pas de veilleuse. Il est muni d’un dispositif d’allumage qui allume automatiquement le brûleur. Ne tentez pas d’allumer le brûleur manuellement. B. AVANT DE FAIRE FONCTIONN ...

  • Rinnai RL94E - page 56

    56 Manuel – Chauffe-eau d’ex térieur série VB LS Diagramme en escalier (RL75e, RL94e) PHASE NEUTRE CONTACT DE DÉTECTION DE GEL FUSIBLE 3 A (intérieur) FUSIBLE 5 A (extérieur) ANTI-FOUDRE ANTI-FOUDRE TERRE VARISTOR VARISTOR RELAIS 1 ALLUMAGE ALIMENTATI ON À DÉCOUPAGE 12 V CC 170 V CC 40 V CC 12,6 V 5 V CC DÉTECTEUR D'ÉCOULEMENT ÉL ...

  • Rinnai RL94E - page 57

    Manuel – Chauffe-eau d’ex térieur série VB LS 57 Diagramme en escalier (R98LSe, R98LSeASME) RELA Y 1 IG FROST SENSING SWITCH ANTI - FROST HEA TER IGN ITION COMBUSTION FA N 3A (F US E ) HO T NE UTR AL VA R I S TOR DC1 2 .6V SOLENO ID DRI VI NG CI RC U I T CPU CENTRAL P R OCESSI N G UNIT FA N REMOTE CONT ROLLER POV FA N CONT ROL CI RCUI T BY- P ...

  • Rinnai RL94E - page 58

    58 Manuel – Chauffe-eau d’ex térieur série VB LS Support à la clientèle Qu'est-ce qui est couvert ? Cette garantie couvre tous défauts dus aux matériaux et à la ma in d'œuvre quand le produit a été i nstallé et utilisé en suivant les instructions écrites d'install ation de Rinnai, dans les term es décrits dans ce do ...

  • Rinnai RL94E - page 59

    Manuel – Chauffe-eau d’ex térieur série VB LS 59 Que fait Rinnai pour exercer la garantie ? Rinnai va réparer ou remplacer le prod uit, ou toute partie ou t out composant défectueux pour caus e de matériaux ou de main d'œuvre, dans les conditions définies pl us loin. Rinnai remboursera des charges de main d'œuvre raison nables ...

  • Rinnai RL94E - page 60

    U2 87- 1 93 2 (00) Pr i nt e d i n Japan VB 2528 W VB 2735 W VA 3237 W 060 0001 2 3066 0 6 ...

Manufacturer Rinnai Category Water Heater

Documents that we receive from a manufacturer of a Rinnai RL94E can be divided into several groups. They are, among others:
- Rinnai technical drawings
- RL94E manuals
- Rinnai product data sheets
- information booklets
- or energy labels Rinnai RL94E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rinnai RL94E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rinnai RL94E, service manual, brief instructions and user manuals Rinnai RL94E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rinnai RL94E.

Similar manuals

A complete manual for the device Rinnai RL94E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rinnai RL94E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rinnai RL94E.

A complete Rinnai manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rinnai RL94E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rinnai RL94E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rinnai RL94E, that we can find in the current document
3. Tips how to use the basic functions of the device Rinnai RL94E - which should help us in our first steps of using Rinnai RL94E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rinnai RL94E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rinnai RL94E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rinnai RL94E?

Use the form below

If you did not solve your problem by using a manual Rinnai RL94E, ask a question using the form below. If a user had a similar problem with Rinnai RL94E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)