Manual Lennox Hearth MPDR-3328CNE-B

42 pages 5.25 mb
Download

Go to site of 42

Summary
  • Lennox Hearth MPDR-3328CNE-B - page 1

    MODELS OTL Report No. 116-F-13-4 US Portland This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a ...

  • Lennox Hearth MPDR-3328CNE-B - page 2

    2 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS P ACKAGING The assembled vented gas fireplace heater is packaged with: • (1 set) Logs (packaged in a carton inside the firebox). • (1 bag) Glowing Embers (in bottom compart- ment). • Literature Kit (envelope in bottom com- ...

  • Lennox Hearth MPDR-3328CNE-B - page 3

    3 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injur y or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , ser vice agency o ...

  • Lennox Hearth MPDR-3328CNE-B - page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T est gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side). The control val ...

  • Lennox Hearth MPDR-3328CNE-B - page 5

    5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS HORIZONT AL VENT (Rear Vent Application with a chase) HORIZONT AL VENT (T op Vent Application) VERTICAL VENT (T op Vent Application) (Rear Vent Application) VERTICAL VENT (Rear ...

  • Lennox Hearth MPDR-3328CNE-B - page 6

    6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINA TION HEIGHTS FOR VENTS ABOVE FL ...

  • Lennox Hearth MPDR-3328CNE-B - page 7

    7 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS Figure 7 V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted ...

  • Lennox Hearth MPDR-3328CNE-B - page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Models Combustible Shelf Height - Inches (millimeters) T op Vent - With One 90 Degree Elbow Rear Vent - Straight Out The Back Se c ur e Ve nt Se c ur e Fle x Se c ur e Ve nt Se ...

  • Lennox Hearth MPDR-3328CNE-B - page 9

    9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 9: Minimum Mantel Clearances Figure 10: Min imum Dis tan ce t o Si de Wa ll Combust ible materials may project beyond one side of the fireplace opening as long as they a ...

  • Lennox Hearth MPDR-3328CNE-B - page 10

    Pressure Relief Plates 10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Side Framing Unit Nailing Flange (No clearance to combustible framing is required .) Unit Secured to Framing by Nailing Flange Header Spacing Top Standof ...

  • Lennox Hearth MPDR-3328CNE-B - page 11

    11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS G H Top View (Louvered Front Model Shown) Concentric Flue: Flue 4-1/2" (114 mm); Combustion Air 7-1/2" (190 mm). See Notes [1] and [2]. Rear/Side Framing Spacers Note ...

  • Lennox Hearth MPDR-3328CNE-B - page 12

    12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS FIREPLACE FRAMING SPECIFICA TIONS Schedule 40 Black Iron Pipe Inside Diameter (Inches) Sc hed ul e 40 Pi p e Le ngt h (f e et ) Na tur al Ga s P ro p a n e G as 0-10 1/2 3/8 10 ...

  • Lennox Hearth MPDR-3328CNE-B - page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Us e onl y ap pr ove d ve nt co mp on en ts (s ee Ap pr ove d V en t Co mpo ne nt s on Pa ge 2 ). These fireplaces must be vented directly to the outside. The vent system may ...

  • Lennox Hearth MPDR-3328CNE-B - page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.4 Centimeters (cm) = Inches x 2.54 Meters (M) = Inches x .0254 T R A H C H T ...

  • Lennox Hearth MPDR-3328CNE-B - page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Min. 10-1/2" (267 mm) Min. 10-1/2" (267 mm) First Vent Component Align the dimple (four places) with the opening of the locking incline channel on appliance collar . ...

  • Lennox Hearth MPDR-3328CNE-B - page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Framing Dimensions for Roof Pitch C D 0/12 10-1/2 in. 10-1/2 in. (267 mm) (267 mm) 6/12 10-1/2 in. 12 in. (267 mm) (305 mm) 12/12 10-1/2 in. 17-3/4 in. (267 mm) (451 mm) Figure ...

  • Lennox Hearth MPDR-3328CNE-B - page 17

    17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 31: Rear Vent - ONE 90-DEGREE ELBOW Figure 30: T op Vent - STRAIGHT Figure 32: T op Vent - TWO 90-DEGREE ELBOWS VERTICAL VENT FIGURES/T ABLES Note: It is ver y important ...

  • Lennox Hearth MPDR-3328CNE-B - page 18

    18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T A BL E C H + H 1 Ma xim um H Ma xim um V Mi nim um fe et fe et fe et 5 (1 .52 4) 2 ( 0. 6 10 ) 1 ( 0. 3 05 ) 10 ( 3.0 48 ) 4 (1 . 21 9 ) 2 (0 . 61 0) 15 ( 4.5 72 ) 6 (1 . 82 ...

  • Lennox Hearth MPDR-3328CNE-B - page 19

    19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 35 The unitized design of the Secure Vent compo- nents will engage and seal both the inner and outer pipe elements with the same procedure. Sealant and securing screws a ...

  • Lennox Hearth MPDR-3328CNE-B - page 20

    20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS IMPORT ANT : The vent termination is hot while in operation and for a period of time following the use of the fireplace. T o prevent contact with hot surfaces, we recommend th ...

  • Lennox Hearth MPDR-3328CNE-B - page 21

    21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS H Max im um V Min imu m fe et fe et 5 (1 .52 4) 1 ( 0. 3 05 ) 10 ( 3.0 48 ) 2 (0 .61 0) 15 ( 4.5 72 ) 3 (0 .91 4) 20 ( 6.0 96 ) 4 (1 .21 9) V + H = 4 0 fe et (12 . 2 m ) Ma x. ...

  • Lennox Hearth MPDR-3328CNE-B - page 22

    22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T ABL E H H + H 1 Ma xim um H Ma xi mu m V M ini mum fe et f ee t f ee t 5 (1 .5 24 ) 2 ( 0. 610 ) 1 (0 .3 05 ) 10 ( 3. 04 8 ) 4 (1 .21 9) 2 (0 . 61 0 ) 15 ( 4. 57 2 ) 6 (1 .82 ...

  • Lennox Hearth MPDR-3328CNE-B - page 23

    23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 44: T op Vent - THREE 90-DEGREE ELBOWS Figure 43: Rear Vent - THREE 90-DEGREE ELBOWS See T able 8 on page 21 as an aid in venting component selection for a particular ra ...

  • Lennox Hearth MPDR-3328CNE-B - page 24

    24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 5" (127 mm) Radius Minimum Flexible Vent Section E. Attach Flex Vent to T ermination - Secure Flex components can be pur chased separately and attached to bulk lengths of ...

  • Lennox Hearth MPDR-3328CNE-B - page 25

    25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 5. FIELD WIRING TP-TH TP TH APPLIANCE- MOUNTED ON/OFF SWITCH (OPTIONAL) BK/W(1) BK/W(1) WALL-MOUNTED ON/OFF SWITCH (OPTIONAL) THERMOST A T (OPTIONAL) JUNCTION BOX BLACK W ...

  • Lennox Hearth MPDR-3328CNE-B - page 26

    26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way for ward and completely to the left or right against the cor ...

  • Lennox Hearth MPDR-3328CNE-B - page 27

    27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS B. Br ush al l jo in t s a nd co n ne cti ons wi t h t he ga s le ak tes t so lu t io n to che ck f or le a ks . If b ub ble s ar e fo rme d, or gas od or is det ect ed, tur n ...

  • Lennox Hearth MPDR-3328CNE-B - page 28

    28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 9. INST ALL VOLCANIC STONE, GLOWING EMBERS AND LOGS NOTE: T urn off all electricity to the appliance before you install volcanic stone, embers and logs. DO NOT attempt to ...

  • Lennox Hearth MPDR-3328CNE-B - page 29

    29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 1 Log Number Description (Stamped #) 1 Log, Rear (39-12) 2 Log, Left (39-1) 3 Log, Right (39-2) 4 Log, T op Center (39-13) 5 Log, T op/Left (39-3 ) 6 Log, T op/Right (39-4) Pos ...

  • Lennox Hearth MPDR-3328CNE-B - page 30

    30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 58 MPD-3530 LOG PLACEMENT Catalog Number for the entire log set: 24M22 Log Number Description (Stamped #) 1 Log, Rear (39-5) 2 Log, Left (39-1) 3 Log, Right (39-2) 4 Log ...

  • Lennox Hearth MPDR-3328CNE-B - page 31

    31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 59 MPD-4035 AND MPD-4540 LOG PLACEMENT Catalog Number for the entire log set: 24M25 1 Log Number Description (Stamped #) 1 Log, Center (39-8) 2 Log, Rear (138) 3 Log, Ri ...

  • Lennox Hearth MPDR-3328CNE-B - page 32

    32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 10. REMOVING AND INST ALLING THE GLASS DOOR Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If a ir s hu tt er i s cl os ed t oo ...

  • Lennox Hearth MPDR-3328CNE-B - page 33

    33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNINGS • Air shutter adjustment should only be performed by a quali- fied profes sion al servic e tech- nician. • Ensure front glass panel are in place and sealed durin ...

  • Lennox Hearth MPDR-3328CNE-B - page 34

    LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 64 Combustible Finished Wall Materials Min. 1" (25 mm) This area must remain clear of combustible materials. Combustible material may touch top of appliance. Combus ...

  • Lennox Hearth MPDR-3328CNE-B - page 35

    LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A TT ACHING SAFETY -IN-OPERA TION WARNINGS It is required that the safety instruction labels furnished with the fireplace be affixed to the op- eration and control point of t ...

  • Lennox Hearth MPDR-3328CNE-B - page 36

    36 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Vent™ Components Cat. No. Model Description 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.5L12 12 Inch (305 mm) 77L72 SV4.5L24 24 Inch (610 mm) 77L73 SV4.5L36 36 Inch ...

  • Lennox Hearth MPDR-3328CNE-B - page 37

    37 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Flex™ Components Cat. # Model Description H1969 SF4.5HT -2 Horizontal Square T ermina- tion for flex (without flex vent) 77L87 SFKIT12S Square T erm. for fle ...

  • Lennox Hearth MPDR-3328CNE-B - page 38

    38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. MPDT/R-3328 H2010 MPD-3530 H2012 MPD-4035 H2014 MPD-4540 H2016 Millivolt SIT Systems Natural ...

  • Lennox Hearth MPDR-3328CNE-B - page 39

    39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Burner Assembly Gas Valve Assembly Orifice Figure 67 Millivolt Appliances Step 4. SIT Systems - Refer to Figure 68 and the instructions provided with the kit. Using a T orx T20 ...

  • Lennox Hearth MPDR-3328CNE-B - page 40

    40 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Retaining Clip Ignitor Assembly Pilot Assembly Pilot Orifice Flare Nut See Figure 71 and replace the pilot orifice as follows: Remove the ignitor assembly retainer clip, and c ...

  • Lennox Hearth MPDR-3328CNE-B - page 41

    41 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTES ...

  • Lennox Hearth MPDR-3328CNE-B - page 42

    42 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, and prices, and also to discontinue colors, styles ...

Manufacturer Lennox Hearth Category Indoor Fireplace

Documents that we receive from a manufacturer of a Lennox Hearth MPDR-3328CNE-B can be divided into several groups. They are, among others:
- Lennox Hearth technical drawings
- MPDR-3328CNE-B manuals
- Lennox Hearth product data sheets
- information booklets
- or energy labels Lennox Hearth MPDR-3328CNE-B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lennox Hearth MPDR-3328CNE-B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lennox Hearth MPDR-3328CNE-B, service manual, brief instructions and user manuals Lennox Hearth MPDR-3328CNE-B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lennox Hearth MPDR-3328CNE-B.

A complete manual for the device Lennox Hearth MPDR-3328CNE-B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lennox Hearth MPDR-3328CNE-B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lennox Hearth MPDR-3328CNE-B.

A complete Lennox Hearth manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lennox Hearth MPDR-3328CNE-B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lennox Hearth MPDR-3328CNE-B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lennox Hearth MPDR-3328CNE-B, that we can find in the current document
3. Tips how to use the basic functions of the device Lennox Hearth MPDR-3328CNE-B - which should help us in our first steps of using Lennox Hearth MPDR-3328CNE-B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lennox Hearth MPDR-3328CNE-B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lennox Hearth MPDR-3328CNE-B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lennox Hearth MPDR-3328CNE-B?

Use the form below

If you did not solve your problem by using a manual Lennox Hearth MPDR-3328CNE-B, ask a question using the form below. If a user had a similar problem with Lennox Hearth MPDR-3328CNE-B it is likely that he will want to share the way to solve it.

Copy the text from the picture