Manual Vermont Casting IRHEDV32

27 pages 0.63 mb
Download

Go to site of 27

Summary
  • Vermont Casting IRHEDV32 - page 1

    1 10003929 10003929 01/02 Rev. 0 * Installation and service must be performed by a qualified installer, service agency or your gas supplier. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHA T T O DO IF YOU SMELL GAS: * Do not try to light any appliance. * Do not ...

  • Vermont Casting IRHEDV32 - page 2

    2 10003929 T ABLE OF CONTENTS Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulations on your purchase of a Irving Oil fireplace. IMPORTANT - READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE STARTING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A POSSIBLE FIRE HAZAR ...

  • Vermont Casting IRHEDV32 - page 3

    3 10003929 When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for these clearances. The underside of the mantel will become warm. Use only finishes which are ...

  • Vermont Casting IRHEDV32 - page 4

    4 10003929 FIREPLACE & TRIM DIMENSIONS R T Q U S V R - Fireplace opening width Q - Fireplace opening height S - Depth of insert T - Firebox width at insert depth(S) U - Firebox depth at insert back height (V) V - Insert back height MINIMUM FIREPLACE INSERT OPENING 1= SS or SSD Trim 2= SL or SLD Trim 3= SXL Trim 4= BSL Trim 5= BXL Trim T R I M F ...

  • Vermont Casting IRHEDV32 - page 5

    5 10003929 Do not use this appliance if any part of it has been under water. Immediately call a quali- fied service technician to inspect the unit and replace any part of the control which has been under water. When purging the gas line, the front glass must be removed. The gas pipeline can be brought into the fireplace base from the right side. It ...

  • Vermont Casting IRHEDV32 - page 6

    6 10003929 INSTALLATION OF TRIM SWITCH FOR RP GAS VALVES 1. Thread wire through openings on the right side of fireplace. Do not cut wire or insulation on metal edges. 2. Slide switch assembly from the back, between subframe and trim, then fasten the screw. (Fig. 3) 3. For left side installation reverse switch position in bracket and repeat Step 2 ( ...

  • Vermont Casting IRHEDV32 - page 7

    7 10003929 Under no circumstances should insulation be put between the damper and the top of the unit. This may cause condensation and overheating of the unit. LINER INSTALLATION - Fig. 6 VENTING DIAGRAM Secure with clamp and three screws Flue gas exits through the vent termination rain cap 1) Attach flexible pipe to rain cap 2) Secure with clamp 3 ...

  • Vermont Casting IRHEDV32 - page 8

    8 10003929 FLUE COLLAR PLATE MOVE BACK CABINET TOP FIG .4 FASTENER PLATE MAKE SURE THE FLUE COLLAR PLATE IS IN CONTACT WITH THE BACK EDGE OF THE CABINET TOP PLATE FLUE COLLAR CABINET TOP FIG.5 FASTENER PLATE MACHINE SCREW AFTER FASTENED Fig. 8 Fig. 9 Fig. 10 Fig. 11 FAN KIT Should this fan require servicing, the power supply must be disconnected. F ...

  • Vermont Casting IRHEDV32 - page 9

    9 10003929 GLASS FRAME W OPERA TING INSTRUCTIONS GENERAL GLASS INFORMATION Only ceramic glass approved by Vermont Castings Majestic Products Company may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this ap ...

  • Vermont Casting IRHEDV32 - page 10

    10 10003929 CERAMIC REFRACTORY INSTALLATION 1. Remove front glass. 2. Remove logs from unit. 3. Remove refractory from package Refractory are fragile and must be han- dled with care. Where at all possible, two hands should be used when handling. 4. Take centre refractory and tilt so bottom edge slides into support angle in back of fireplace. Fig. 1 ...

  • Vermont Casting IRHEDV32 - page 11

    11 10003929 L O H I Turn counterclockwise to decrease flame height. Turn clockwise to increase flame height. Fig. 18 FLAME ADJUSTMENT Flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 18) It is important to periodically perform a visual check of the pilot and the burner flames. ...

  • Vermont Casting IRHEDV32 - page 12

    12 10003929 1. STOP! Read the safety information above on this label. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clock ...

  • Vermont Casting IRHEDV32 - page 13

    13 10003929 SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off pilot and electrode at pilot. push the red button again. If pilot will not light - check gap at electrode and pilot-should be 1/8" to have a strong spark. B. Defective ignitor (P ...

  • Vermont Casting IRHEDV32 - page 14

    14 10003929 • GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED. • ALL WIRING CONNECTIONS • REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES • THERMOPILE NEEDS A MINIMUM 325m ...

  • Vermont Casting IRHEDV32 - page 15

    15 10003929 REPLACEMENT P ARTS IRHEDV32 35 30 31 32 27 29 28 25 26 3 2 33 34 22 24 15 L O H I PILOT ADJ PILOT ON OFF 23 a/b 21 20 19 14 12 16 8 a/b 9 a/b 13 18 17 11 a/b 18 10a/b ...

  • Vermont Casting IRHEDV32 - page 16

    16 10003929 REPLACEMENT P ARTS LIST Description IRHEDV32 1 Log Set Complete 57896 1a Log Ember Front KR1 1b Log Front Left KR2 1c Log Front Right KR3 1d Log Rear KR4 1e Log Top Left KR5 1f Log Top Right KR6 2 Lava Rock (Package) 10001454 3 Burner Lava Rock (Package) 57897 4a Burner Complete With Tiles (Nat.) 10000198 4b Burner Complete With Tiles ( ...

  • Vermont Casting IRHEDV32 - page 17

    10003929 A-TRIM OPTIONS FOR RHEDV32 17 FRAME ASSEMBLY 1. Lay Trim Top Facing and Trim Side Facings, face down on to an even surface such as a table or floor. Be sure not to scratch the painted surfaces. 2. Install the nuts and bolts (Fig. 21). Fig. 21 A1) RHESS, RHESL, RHESSD, RHESLD & RHESXL TRIMS RHESS, RHESL, RHESSD, RHESLD and RHESXL TRIM A ...

  • Vermont Casting IRHEDV32 - page 18

    10003929 Fit Decorative Frame to the fireplace and fasten (Fig. 25). Plastic on the trim must be removed before mounting onto the fireplace. Glass must be tightly pressed against the front of the frame in order to prevent screws from damaging glass edges. Fig. 25 AS SHOWN FROM FRONT SCREWS FRAME MOUNTING GENERAL INFORMATION The Decorative Front Fra ...

  • Vermont Casting IRHEDV32 - page 19

    10003929 KEY DESCRIPTION RHESS (2) RHESL (3) RHESSD (3) RHESLD (3) RHESXL (4) 1 Trim Frame Top, Flat Black 57929 57932 57929 57932 57935 2 Trim Frame Left, Flat Black 57927 57930 57927 57930 57933 3 Trim Frame Right, Flat Black 57928 57931 57928 57931 57934 4 Trim Top Deflector (1) 17634 17634 17634 17634 17634 5 Trim Top Channel (1) 50586 50587 17 ...

  • Vermont Casting IRHEDV32 - page 20

    10003929 TRIM ASSEMBLY 1. Install trim channels (left and right sides). Use two screws to assemble each piece. 2. Slide on the trim top channel and fasten it from the back side. 3. Install the trim top deflector and use two screws to fasten it. (Fig. 26) 4. Remove ALL plastic protective covering from brass trim. RHEBSL Fig. 26 To install the kit yo ...

  • Vermont Casting IRHEDV32 - page 21

    10003929 A3) RHEF A and RHEFP TRIMS Glass Frame Louvre Note: Position brass trim top as shown (small end up) to prevent heat discolouration Fig. 27 Fig. 28 1. Remove the front glass (see "Glass Frame Re- moval" section). 2. Install support window trim channel, top and bottom brass trim by using the shortest black screw. (Fig. 43 & 44) ...

  • Vermont Casting IRHEDV32 - page 22

    10003929 A4) HEBTKP , HESBTKP , HECBTK, HECBTKMB & HEBT A TRIMS HECBTK - Cast bay window and grills in classic black trim kit HECBKMB - Cast bay window and grills in midnight black porcelain enamel trim kit HESBTKP - Steel bay window with polished brass and cast grills in classic black trim kit HEBTKP - Steel bay window and bay louvres with pol ...

  • Vermont Casting IRHEDV32 - page 23

    10003929 1) Reposition controls. a) Remove the Fan Speed Control Box (Fig. 33). b) Attach the Fan Speed Control Box to the Bracket (Fig. 34) and install the Bracket into the Cabinet. Only for RN/RP VALVE units. c) Install the Control Knobs Extensions onto the appropriate Control Valve Knobs (Fig. 34). On units fitted with a Honeywell brand control ...

  • Vermont Casting IRHEDV32 - page 24

    10003929 Fig. 39. Attach magnets and brass trim to the steel frame. Fig. 40. Bracket for HEBTKP. Fig. 37. Hang the Window Grille or the Steel Frame onto the lower tabs of the Hanging Brackets. Fig. 38. Engage the slots in the Upper Grille Top Louvre with the upper tabs of the Hang- ing Brackets. 24 ...

  • Vermont Casting IRHEDV32 - page 25

    10003929 (1) With magnets. IMPORTANT: Only Trim Panel Assemblies Approved by Vermont Castings Majestic Products Company Can Be Used on These Products. ALL repair parts will be available from your local dealer. When ordering, always give the following information: Model and serial number, part description with finish and part number; 11 12 15 14 16 ...

  • Vermont Casting IRHEDV32 - page 26

    10003929 26 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim (Fig. 58). 5. Fasten the trim with the same two (2) screws removed on step 3. Note: The riser kit should only be used wi ...

  • Vermont Casting IRHEDV32 - page 27

    10003929 8" x 12" VENT TERMINATION KIT Model: HEDVT (8" x 12") (Fit Typical 8" x 12" and 9" x 13" flue Tile) Kit Includes: A - 8" x 12" Vent Termination (x1) B - Stainless Steel Clamps 3"-3.5" (x4) C - Hardware Package (x1) D - High Temperature Sealant (x1) FLEX VENT KIT Model: HEDVK25 Inc ...

Manufacturer Vermont Casting Category Ventilation Hood

Documents that we receive from a manufacturer of a Vermont Casting IRHEDV32 can be divided into several groups. They are, among others:
- Vermont Casting technical drawings
- IRHEDV32 manuals
- Vermont Casting product data sheets
- information booklets
- or energy labels Vermont Casting IRHEDV32
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vermont Casting IRHEDV32.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vermont Casting IRHEDV32, service manual, brief instructions and user manuals Vermont Casting IRHEDV32. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vermont Casting IRHEDV32.

A complete manual for the device Vermont Casting IRHEDV32, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vermont Casting IRHEDV32 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vermont Casting IRHEDV32.

A complete Vermont Casting manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vermont Casting IRHEDV32 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vermont Casting IRHEDV32, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vermont Casting IRHEDV32, that we can find in the current document
3. Tips how to use the basic functions of the device Vermont Casting IRHEDV32 - which should help us in our first steps of using Vermont Casting IRHEDV32
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vermont Casting IRHEDV32
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vermont Casting IRHEDV32 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vermont Casting IRHEDV32?

Use the form below

If you did not solve your problem by using a manual Vermont Casting IRHEDV32, ask a question using the form below. If a user had a similar problem with Vermont Casting IRHEDV32 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)