  • York F3EH090 - page 1

    GENERAL These completely assembled indoor units include a well- insulated cabinet, a copper tube/aluminum fin coil, throw - away filters, a centrifugal blower , a blower motor , an adjust - able V -belt drive, a blower motor contactor and a small holding charge of an inert gas. They also include a filter- drier , an expansion valve and a distributo ...

  • York F3EH090 - page 2

    035-09651-001-A-0304 2 Unitary Products Group T ABLE OF CONTENTS GENERAL ............................................................................. 1 REFERENCE ............................................................................. 1 INSPECTION ............................................................................. 1 NOMENCLATURE ... ...

  • York F3EH090 - page 3

    rate request for inspection by the carrier's agent should be made in writing. LIMIT ATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply , installation must conform with the appropriate national codes. Units are de - signed to meet National Safety Code S tandards. If components ar ...

  • York F3EH090 - page 4

    035-09651-001-A-0304 4 Unitary Products Group FIG . 1 - UNIT SUSPENSION MOUNTING (Horizontal Application) Model Power Supply V oltage V ariation 1 Supply Air CFM Entering Air T emperatures, ° F Cooling - wb Heating - db Min. Max. Min. Max. Min. Max. Min. Max. F3EH090 208/230-3-60 187 252 2400 3600 57 72 50 2 80 460-3-60 414 506 380/415-3-50 342 45 ...

  • York F3EH090 - page 5

    WARNING: Do not permit overhanging structures or shrubs to obstruct air discharge. Additional height may be required for snow clearance if winter operation is expected. VERTICAL / HORIZONT AL INST ALLATION These indoor units are shipped for vertical installation with ver - tical air discharge as shown in Figure 2(A) but may be con - verted for hori ...

  • York F3EH090 - page 6

    Form 035-16650-001 – Supply Air Plenum Form 035-16621-001 – Return Air Grille Form 035-16632-001 – Base The supply air plenum and the return air grille should be used in lieu of ductwork only when a free blow/free return application is practical. REFRIGERANT MAINS Many service problems can be avoided by taking adequate precautions to provide ...

  • York F3EH090 - page 7

    A 7/8" OD drain connection extends through right hand side of cabinet. Refer to Fig. 7 for recommended drain piping. The drain connection is located on the same side of the unit as the refrigerant connections. The line should be insulated where moisture drippage will be objectionable or cause damage to the area. The 3" dimension must equa ...

  • York F3EH090 - page 8

    035-09651-001-A-0304 8 Unitary Products Group FIG . 9 - HOLE LOCA TIONS FOR PRESSURE DROP READINGS FIG . 10 - PRESSURE DROP ACROSS A DRY INDOOR COIL VS. SUPPL Y AIR CFM RPM CFM ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW F3EH090 (60 Hz) 2400 2700 3000 3300 3600 600 0.30 0.62 0.79 0.21 0.70 0.76 0.09 0.78 0.89 ------ 655 0.43 0. ...

  • York F3EH090 - page 9

    035-09651-001-A-0304 Unitary Products Group 9 Model Accessory S tatic Resistance, IWG BLOWER CFM 2400 2700 3000 3300 3600 F3EH090 Electric Heat 10 KW 0.01 0.01 0.01 0.02 0.02 16 KW 0.01 0.02 0.02 0.03 0.04 26 KW 0.03 0.04 0.05 0.06 0.07 36 KW 0.05 0.07 0.08 0.10 0.1 1 Supply Air Plenum 0.03 0.03 0.04 0.05 0.06 Return Air Grille 0.02 0.03 0.04 0.05 ...

  • York F3EH090 - page 10

    POWER AND CONTROL WIRING Install electrical wiring in accordance with the latest National Electrical Code (NFP A S tandard No. 70) and/or local regula - tions. The unit should be grounded in accordance with these codes. Route the power wires into the unit through the 1-3/8” knockout in the rear panel, and connect them to the terminals on blower m ...

  • York F3EH090 - page 11

    035-09651-001-A-0304 Unitary Products Group 11 FIG .12 - UNIT DIMENSIONS & CLEARANCES (F3EH090 & F4EH120) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4" to unit height when used. • SUPPL Y AIR PLENUM - Add 27-1 ...

  • York F3EH090 - page 12

    SECURE OWNER'S APPROV AL: When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat. T each him how to start and stop the unit, how to adjust temperature settings within the limitations of the system, how the defrost cycle is controlled and how the anti-cycle ...

Manufacturer York Category Heat Pump

Documents that we receive from a manufacturer of a York F3EH090 can be divided into several groups. They are, among others:
- York technical drawings
- F3EH090 manuals
- York product data sheets
- information booklets
- or energy labels York F3EH090
All of them are important, but the most important information from the point of view of use of the device are in the user manual York F3EH090.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York F3EH090, service manual, brief instructions and user manuals York F3EH090. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York F3EH090.

Similar manuals

A complete manual for the device York F3EH090, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York F3EH090 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York F3EH090.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York F3EH090 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York F3EH090, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York F3EH090, that we can find in the current document
3. Tips how to use the basic functions of the device York F3EH090 - which should help us in our first steps of using York F3EH090
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York F3EH090
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York F3EH090 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York F3EH090?

Use the form below

If you did not solve your problem by using a manual York F3EH090, ask a question using the form below. If a user had a similar problem with York F3EH090 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)