Manual Cabletron Systems KBU64 Rackmount

26 pages 0.1 mb
Download

Go to site of 26

Summary
  • Cabletron Systems KBU64 Rackmount - page 1

    KBU64 Rackmount User Manual Fivemere Ltd. Cabletron Systems Ltd. Fivemere House Network House 161 High Street Newbury Business Park Aldershot London Road, Newbury Hampshire, England Berkshire, England GU11 1TT RG13 2PZ Telephone: [44] (0) 1635 580000 Fax: [44] (0)1635 44578 ...

  • Cabletron Systems KBU64 Rackmount - page 2

    KBU64 Rackmount User Manual 80-10100001-09 ii Publication — 80-10100001-09 Publication Notice: Thi s manual has been compi l ed and checked f or ac curacy. Howev er the inf or mat ion c ontai ned in t his m anual does not consti tut e a warranty of perf orm ance. Cablet ron System s Ltd. reserv es the ri ght t o rev i se this publi cat ion f rom ...

  • Cabletron Systems KBU64 Rackmount - page 3

    KBU64 Rackmount User Manual 80-10100001-09 iii History Sheet 80-10100001-09 Issued separatel y f or the R/ M due to USA requirements 21 January 1998 ...

  • Cabletron Systems KBU64 Rackmount - page 4

    KBU64 Rackmount User Manual 80-10100001-09 iv TABLE OF CONTENTS 1 KBU 64 RACKMOUNT SPECIFICATION 1–1 1.1 I NTRODUCTION 1–1 2 FRONT AND REAR PANELS AND INTERFACES 2–1 2.1 F RONT P ANEL 2–1 2.2 R EAR I NTERFACE C ARDS 2–1 2.2.1 L INK S ETTINGS 2–3 2.2.2 C OMMAND P ORT - KBU 64 R EAR I NTERFACE C ARDS 2–4 2.2.3 V35 R EAR I NTERFACE C ARD ...

  • Cabletron Systems KBU64 Rackmount - page 5

    KBU 64 Rackmount Specification 80-10100001-09 1–1 1 KBU 64 Rackmount S pecification 1.1 Intr oduction Thi s m anual des c ribes the Rackmount v ersi on of the KBU64. The standalone K BU 64 has its own manual , Publ i cati on 80- 10100000. F or inf or mat ion on t he com m and menus and param eter s in the rack mount version, you will need to refe ...

  • Cabletron Systems KBU64 Rackmount - page 6

    KBU64 Rackmount User Manual 80-10100001-09 1–2 Fiv em ere Fivem ere Figure 1.1 The KBU 64 Rackmount Version Up to 13 KBU 64 card pai rs m ay be f it ted wit h eit her one or two power suppli es f or resil ience. The 1st car d s l ot i s f or t he Manager Card which contr ols all c ards w i thi n the r ack v i a the K BU 64 poll ed m anagem ent sy ...

  • Cabletron Systems KBU64 Rackmount - page 7

    KBU 64 Rackmount Specification 80-10100001-09 1–3 The rackm ount v ersi on of the KBU 64 i s func ti onall y the sam e as the standalone i n m ost respects, as it uses the sam e soft w are. Ther ef ore m ost of the secti ons of y our K BU64 M anual m anual (Publ ic ati on 80- 10100000) relating to KBU 64's operation are relevant. The rackmou ...

  • Cabletron Systems KBU64 Rackmount - page 8

    Front and Rear Panels and Interfaces 80-10100001-09 2–1 2 Front and R ear Panels and Inter faces 2.1 Fr ont Panel See the KBU64 standalone m anual (Publ ic ati on 80-10100000) f or t he description of operation. 2.2 Rear Interface Car ds W i th all 3 c ard types t he USER port s are conf igur ed as phys ic al DCEs, the LINK ports as DTEs. T he US ...

  • Cabletron Systems KBU64 Rackmount - page 9

    KBU64 Rackmount User Manual 80-10100001-09 2–2 T 10 3 R 104 C 108 I 1 0 7 S 114 11 5 10 5 10 9 BACKUP USE R 1 Fr ont Rear ( X. 21) Rear ( V. 35) USE R 2 T 10 3 R 104 C 108 I 1 0 7 S 114 11 5 10 5 10 9 BACKUP B 1 IN US E B1 B ACKUP B 2 IN US E B2 B ACKUP AL AR M 1 AL AR M 2 USER 1 LI N K 1 USER 2 LI N K 2 COM MA ND IS D N LI N K 1 USER 2 LI N K 2 ...

  • Cabletron Systems KBU64 Rackmount - page 10

    Front and Rear Panels and Interfaces 80-10100001-09 2–3 2.2.1 Link Settings For al l 3 ty pes of Rear Int erf ace Car d t he com m and port j um per setti ngs are as follows: Without Manager Card With Manager Card Link Normal Polled Polled Only JP8 IN IN X JP9 OUT OUT X JP10 OUT IN X JP11 IN O UT X JP12 IN IN O UT JP13 IN IN O UT JP14 IN IN O UT ...

  • Cabletron Systems KBU64 Rackmount - page 11

    KBU64 Rackmount User Manual 80-10100001-09 2–4 2.2.2 Command Port - KBU 64 Rear Interface Cards The com m and por t on each of t he Rear I nterf ac e Card types is a f em al e 15 way 'D' type and uses the same V 28 lev el ci rcui ts as t he standal one KBU 64. You can only us e thi s com mand por t w hen a Manager Card i s not fitted in ...

  • Cabletron Systems KBU64 Rackmount - page 12

    Front and Rear Panels and Interfaces 80-10100001-09 2–5 2.2.3 V35 Rear Interface Card The User and Link connectors are both 34 way female MRAC. The pin assignments are as follows: Pin No. Circuit No. Signal Name As su m ing con f igured as DTE A 101 Chassis Earth Common return B 102 Signal Ground/Chassis Earth Common return P 103A Transmit Data A ...

  • Cabletron Systems KBU64 Rackmount - page 13

    KBU64 Rackmount User Manual 80-10100001-09 2–6 2.2.4 X21 Rear Interface Card The User and Link connectors are both 15 way 'D'. The pin assignments are as follows: Pin No. Circuit No. Signal Name As su m ing con f igured as DTE 1 Ground Chassis Earth Common return 8 G Signal Ground/Chassis Earth Common return 2 Ta Transmit Data A Generat ...

  • Cabletron Systems KBU64 Rackmount - page 14

    Manager Card 80-10100001-09 3–1 3 Ma nager Car d 3.1 Intr oduction The KB U 64 Manager Card i s a discrete c ard f or use with only rackm ount KBU 64 cards. Li ke the rac km ount KBU 64, the Manager Card al so cons ists of a card pai r. The rear card prov ides a com m and port for management of all KBU 64 cards within its rack. The Manager Card m ...

  • Cabletron Systems KBU64 Rackmount - page 15

    KBU64 Rackmount User Manual 80-10100001-09 3–2 Fr ont RXD TX D R ear C OMMA ND 1 OFF 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF 7 OFF 8 OFF 9 OFF 10 OFF 12 OFF 13 OFF 11 OFF PW R 1 PW R 2 Figure 3.1 Front and Rear Panels of the Manager Card ...

  • Cabletron Systems KBU64 Rackmount - page 16

    Manager Card 80-10100001-09 3–3 3.2 Fr ont Panel The f ront panel of t he Manager Card has the f oll owing c ontrol s and indicators: • Transm i t and rec eiv e data LE D’s for the com m and ter m inal data li nes. These LED’s displ ay dat a acti v i ty on both the tr ansm it and receive data circuits. • AC power indi cati on f or each of ...

  • Cabletron Systems KBU64 Rackmount - page 17

    KBU64 Rackmount User Manual 80-10100001-09 3–4 The pin assignments are as follows: Pin No. Circuit No. Signal Name 1 101 Chassis Earth 2 103 Transmit Data 3 104 Receive Data 4 105 Request to Send 5 106 Clear to Send 6 107 Data Set Ready 7 102 Signal Ground/Chassis Earth 8 109 Data Carrier Detect 15 114 Transmit clock 17 11 5 Receive clock 20 108 ...

  • Cabletron Systems KBU64 Rackmount - page 18

    Card Installation 80-10100001-09 4–1 4 Card Installation Each KB U 64 ‘f ront’ car d must be associat ed with an appropri ate (V. 24, X.21, or V .35) rear i nterf ace c ard i.e. they shoul d always be instal led i n pairs (although no damage will result in partial installation) If the KBU 64s are to be m anaged indi v i dual ly v i a thei r r ...

  • Cabletron Systems KBU64 Rackmount - page 19

    KBU64 Rackmount User Manual 80-10100001-09 4–2 4.2 Confi guration Us ing a Manager Car d W i th the Manager Card pai r and all KBU card pai rs fi tt ed the f irst t as k i s to set the indi v i dual K BU 64 poll num bers. Onc e all the uni ts are instal l ed and a suitabl e term i nal c onnected to the rack m anager card com m and port, the lock ...

  • Cabletron Systems KBU64 Rackmount - page 20

    Installation and Power Supply Requirements 80-10100001-09 5–1 5 Installati on and Power Supply Requirem ents Safety Warning: Before connecting the mains supply to the unit check the supply voltage as detailed below. The product i s a high densit y rack mount ed unit designed to si t i n a 19" com muni cati ons cabi net, i t has f our f ix in ...

  • Cabletron Systems KBU64 Rackmount - page 21

    KBU64 Rackmount User Manual 80-10100001-09 5–2 should be rem ov ed and t he cabl e re-wired t o the corr ect type of plug. The use of adaptors is not recommended. The w ir es in the supply cord are col oured i n accordanc e w it h the following code:- Green and Yellow Earth Blue Neutral Brown Live As these colour s may not correspond with t he te ...

  • Cabletron Systems KBU64 Rackmount - page 22

    Installation and Power Supply Requirements 80-10100001-09 5–3 20m m x 5m m , 3. 15AH,250V A nti -surge (T) t ype f or 110V t o 120V ratings. If any problem s ar e encounter ed w it h f uses conti nual ly bl owing the following alternative ratings maybe used: 20m m x 5m m , 3. 15AH,250V A nti -surge (T) t ype f or 220V t o 240V ratings. 20m m x 5m ...

  • Cabletron Systems KBU64 Rackmount - page 23

    Rack Specifications 80-10100001-09 6–1 6 Rack Specifications Dimensions 482mm W; 400mm H (9U); 370mm D Mains Voltage 93-132V (110-120V nominal) 187-264V (220-240V nominal) Consumption 200VA max. Frequency 50/60Hz nominal Mains Rear Panel Fuses 1.6 or 3. 15AH, 250V Anti -Surge (T) 20x5mm (220-240V range) 3.15 or 6. 3AH, 250V Anti -Surge (T) 20x5mm ...

  • Cabletron Systems KBU64 Rackmount - page 24

    KBU64 Rackmount User Manual 80-10100001-09 6–2 Environment Ambient temperature: Operating 0 ° C to 30 ° C Storage -20 ° C to 70 ° C Atm ospheri c pressure: 86.0kP a to 106.0kPa Relat iv e Hum idi ty : 5% to 95% non-condensing ...

  • Cabletron Systems KBU64 Rackmount - page 25

    Regulatory Requirements 80-10100001-09 7–1 7 Regulator y R equir ements 7.1 Uni ted Kingdom and Eur ope Users based in the Unit ed Ki ngdom and Europe m ust pay parti cul ar at tent i on to the information contained in sections 7.1 and 7.2 . B.A.B.T. Pan European Approval number AA6046512. 1. The KB U 64 Rackm ount i s approv ed f or connec ti on ...

  • Cabletron Systems KBU64 Rackmount - page 26

    KBU64 Rackmount User Manual 80-10100001-09 7–2 3. The KB U 64 Rac k m ount i s approv ed f or di rect c onnec t ion to the X.21 and X.21 bis (V. 35) or X.21 bis (V.28) Ki l ostream  prov i ded by Bri ti sh Tel ecom PLC or any sim il ar serv i ce prov i ded by other B rit ish Tel ecom m unicat ions operat ors, or a rel ev ant branch system f or ...

Manufacturer Cabletron Systems Category Network Card

Documents that we receive from a manufacturer of a Cabletron Systems KBU64 Rackmount can be divided into several groups. They are, among others:
- Cabletron Systems technical drawings
- KBU64 Rackmount manuals
- Cabletron Systems product data sheets
- information booklets
- or energy labels Cabletron Systems KBU64 Rackmount
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cabletron Systems KBU64 Rackmount.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cabletron Systems KBU64 Rackmount, service manual, brief instructions and user manuals Cabletron Systems KBU64 Rackmount. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cabletron Systems KBU64 Rackmount.

A complete manual for the device Cabletron Systems KBU64 Rackmount, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cabletron Systems KBU64 Rackmount by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cabletron Systems KBU64 Rackmount.

A complete Cabletron Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cabletron Systems KBU64 Rackmount - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cabletron Systems KBU64 Rackmount, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cabletron Systems KBU64 Rackmount, that we can find in the current document
3. Tips how to use the basic functions of the device Cabletron Systems KBU64 Rackmount - which should help us in our first steps of using Cabletron Systems KBU64 Rackmount
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cabletron Systems KBU64 Rackmount
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cabletron Systems KBU64 Rackmount in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cabletron Systems KBU64 Rackmount?

Use the form below

If you did not solve your problem by using a manual Cabletron Systems KBU64 Rackmount, ask a question using the form below. If a user had a similar problem with Cabletron Systems KBU64 Rackmount it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)