    1 Pub. 988-0151-182 Addendum I LMS-480M, LMS-480DF & GlobalMap 4800M This addendum addresses new items pa cked with your unit, changes to installation procedures, and NMEA 2000 upgrades not documented in the LMS 480M, LMS-480cDF and GlobalMap 4800M manuals. Your unit now packs with a 2-foot (61 cm) blue-to-red adapter cable, 15- foot (4.6 m) ex ...

  • Lowrance electronic LMS-480DF - page 2

    2 Power Connections Your unit comes with a power/data cable that splits into three branches, each with several exposed wires. The thicker three-wire cable (white, red and black) is the power supply for your display unit. This cable has no label. The thinner branch with three wires (red, black and shield) is the power cable for a NMEA 2000 network. ...

  • Lowrance electronic LMS-480DF - page 3

    3 Powering Your Display Unit The display unit works from a 12-volt DC battery system. Attach the display power cable (with provided 3-amp fuse) to an accessory switch or power bus. If this results in elec trical interference, connect direct to a battery but install an in-line switch on the cable. Caution: We strongly recommend that you shut off the ...

  • Lowrance electronic LMS-480DF - page 4

    4 For example, if you have to extend the power cable to the power bus or battery, attach one end of the fuse holder directly to the power bus or battery. This will protect both the unit and the power cable in the event of a short. This unit has reverse polarity protec tion. No damage will occur if the power wires are reversed. However, the unit wil ...

  • Lowrance electronic LMS-480DF - page 5

    5 Powering a NMEA 2000 Network Bus A NMEA 2000 bus must be connected to a power source to operate. NMEA 2000 devices, including GPS mo dules, draw their power from the ne two rk bus . If you have a pre-existing NMEA 2000 network instal- lation, it may already be connected to another power source. If you are not sure about a network's power st ...

  • Lowrance electronic LMS-480DF - page 6

    6 when not in use. Failure to connect to and use a power switch will drain your boat battery, which could stop your boat's operation. GPS Antenna/Receiver Module Your unit packs with the LGC-3000 GP S module. This device contains the unit's external antenna and rece iver for GPS and WAAS signals. The antenna/receiver module comes with a 1 ...

  • Lowrance electronic LMS-480DF - page 7

    7 the telephone wiring in a house. If yo u pick up a phone in your living room, you can hear someone talking into the phone in the bedroom. Lowrance and LEI provide all the cables you will need to create a NMEA 2000 network. Lowrance provides T co nnectors and extension cables so you can add devices along the backbone wherever you want. Once you ha ...

  • Lowrance electronic LMS-480DF - page 8

    8 Cable connections for LMS-480M and LMS-480DF. Netw ork socket Pow er/Data socket Display unit pow er cable Sonar socket Transducer NMEA-2000 Pow er cable Speed sensor Data cable LGC-3000 120 ohm terminator 120 ohm terminator Extension cable Double T connector Blue-to-red adapter cable ...

  • Lowrance electronic LMS-480DF - page 9

    9 Cable connections for the GlobalMap 4800M. Netw ork socket Pow er/Data socket NMEA-2000 Pow er cable Data cable LGC-3000 120 ohm terminator Double T connector Blue-to-red adapter cable 120 ohm terminator Extension cable Display unit pow er cable ...

  • Lowrance electronic LMS-480DF - page 10

    10 NMEA 2000 Device Configuration The NMEA 2000 menu on your display unit's main menu allows you to configure, calibrate and monitor devices on a NMEA 2000 network. The NMEA 2000 menu provides access to the Bus Setup, Fuel Management and NMEA 2000 Alarms. You also can turn on/off Waypoint Sharing and Backlight Synchronization from the NMEA 200 ...

  • Lowrance electronic LMS-480DF - page 11

    11 The NMEA Diagnostics page displays information about the perform - ance of the network bus, keeping you updated on bus status, mode, er- rors and bus traffic. The Ethernet Diagnostics page keeps you updated on the performance of an Ethernet connection (if applicable) supplying information ranging from IP Addre ss to upload and download rates (by ...

  • Lowrance electronic LMS-480DF - page 12

    12 Tank Select The Tank Select menu allows you to choose from up to three tanks (Port, Center and Starboard), depe nding on the Engine-tank configura- tion that has been selected. This allows you to set up each tank indi- vidually. Tank Size The Tank Size menu allows you to inpu t the size of a selected tank in gallons. After selecting the desired ...

  • Lowrance electronic LMS-480DF - page 13

    13 7. Use ↓ ↑ , ← → to input the capacity (gallons) of the tank you chose from the Tank Select menu and press ENT . 8. Repeat Steps 5-7 for each remaining tank. 9. When all tanks have been configured, press the S ET C ONFIGURATION but- ton. The following confirmation message will appear: Are you sure you wish to change the bus configuration ...

  • Lowrance electronic LMS-480DF - page 14

    14 The Device Data for an EP-10 Fuel Flow includes F uel Rate (amount of fuel burned per hour), Fuel Used, Trip Fuel Used and Seasonal Fuel Used. NOTE: If, as in the graphic above, you do not have a Suzuki Engine Inter- face, EP-15 Fluid Level or EP-10 Fuel Flow on the network, the Engine & Configuration menu, Tank Select menu, Tank Size dialog ...

  • Lowrance electronic LMS-480DF - page 15

    15 A dd Fuel After entering the amount of fuel added to a tank in the Fuel Added dialog, the Add Fuel command finalizes the entry of the data. L ike the Fuel Added dialog, the Add Fuel command will only be used when an amount of fuel is added that does not fill up the tank. Fill Tank You will use the Fill Tank command when calibrating a fuel flow a ...

  • Lowrance electronic LMS-480DF - page 16

    16 To Reset Calibration: Choosing the Reset Calibration command will switch fuel flow calibra- tion settings back to factory defaults. 1. Press MENU | MENU , select NMEA 2000 and press ENT . 2. Highlight F UEL M AN AGE M EN T and press ENT . The Fuel Management menu will appear. 3. Highlight to E NGINE S ELECT and press ENT . Select the desired eng ...

  • Lowrance electronic LMS-480DF - page 17

    17 The second tab at the top of the NMEA 2000 Alarms page is the Alarm Status Tab. When an alarm has been set for a device, the alarm and its current status will be shown on the Alarm Status window. To view the Alarm Status window, highlight the Alarm Status tab and press ENT . To set NMEA 2000 A larm: 1. Press MENU | MENU , select NMEA 2000 and pr ...

  • Lowrance electronic LMS-480DF - page 18

    18 Configuring EP Sensors All configurable devices are configured through their Device Configura- tion menus, which may be accessed th rough the network devices list on the Bus Configuration menu. EP-35 Temperature Configuration To input Devic e Name: 1. Press MENU | MENU , use ↑ ↓ to select NMEA 2000 and press ENT . The NMEA 2000 menu will app ...

  • Lowrance electronic LMS-480DF - page 19

    19 Instance The Instance command is intended for use only by experienced NMEA 2000 network technicians. Instance a llows network technicians to re- solve certain electronic probe conflicts. This is most likely to occur if the network includes LMF-200 or LMF-400 digital gauges, which support the display of fewer electronic probes than your GPS or so ...

  • Lowrance electronic LMS-480DF - page 20

    20 3. Select the fuel flow you want to rename and press ENT . The Device Configuration menu will appear with the Device Name dialog box high- lighted. 4. Press ENTER and use ↑ ↓ , ← → to input the desired name for the fuel flow. Press ENT . Press EXIT repeatedly to get back to the main display. To select a Location: 1. Press MENU| MENU , us ...

  • Lowrance electronic LMS-480DF - page 21

    21 To restore default se ttings: 1. Press MENU| MENU , use ↑ ↓ t o s e l e c t NMEA 2000 and press ENT . The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Man- agement, NMEA 2000 Alarms, Waypoint Sharing and Backlight Syn- chronization. 2. Highlight B US S ETUP and press ENT , which will open the Bus Configu- ration menu. A list ...

  • Lowrance electronic LMS-480DF - page 22

    22 5. Select the desired Tank Instance (location) and press ENT . The fol- lowing confirmation message will appear: Are you sure you wish to change this device's configuration? 6. Highlight Y ES and press ENT . Press EXIT repeatedly to get back to the main display. To select Fluid Ty pe: 1. Press MENU| MENU , use ↑ ↓ to select NMEA 2000 an ...

  • Lowrance electronic LMS-480DF - page 23

    23 Instance The Instance command is intended for use only by experienced NMEA 2000 network technicians. Instance a llows network technicians to re- solve certain electronic probe conflicts. This is most likely to occur if the network includes LMF-200 or LMF-400 digital gauges, which support the display of fewer electronic probes than your GPS or so ...

  • Lowrance electronic LMS-480DF - page 24

    24 Suzuki Engine Interface Configuration To input Devic e Name: 1. Press MENU| MENU , use ↑ ↓ to select NMEA 2000 and press ENT . The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Man- agement, NMEA 2000 Alarms, Waypoint Sharing and Backlight Syn- chronization. 2. Highlight B US S ETUP and press ENT , which will open the Bus Con ...

  • Lowrance electronic LMS-480DF - page 25

    25 5. Select your engine type and press ENT . The following message will appear : Are you sure you wish to change this device's configuration? 6. Highlight Y ES and press ENT . Press EXIT repeatedly to get back to the main display. Advanced Options menu The Engine Interface Advanced Options menu contains three catego- ries: Instance, Restore D ...

  • Lowrance electronic LMS-480DF - page 26

    26 NOTE: The Suzuki Engine Interface Devi ce Configuration menu contains two Engine Trim calibration commands, which will be addressed in the next segment of this section, Calibrating EP Sensors. Calibrating EP Sensors The factory calibration settings for the EP-10 Fuel Flow, EP-15 Fluid Level and Suzuki Engine Interface sh ould be adequate for the ...

  • Lowrance electronic LMS-480DF - page 27

    27 To calibrate an EP-10 Fuel Flow : 10. If calibration is necessary, press MENU | MENU , select NMEA 2000 and press ENT . 11. Highlight F UEL M AN AGE ME NT and press ENT . 12. Select T ANK L OCATION and press ENT to choose the location of the tank connected to selected fuel flow. Press ENT . 13. Highlight F ILL T AN K and press ENT . The followin ...

  • Lowrance electronic LMS-480DF - page 28

    28 3. Select the EP-15 Fluid Level and press ENT . 4. Press ↓ to select C A LIBRATE and press ENT . The Device Calibration menu will appear. Instructions on Calibration will be listed at the top of the menu. 5. Highlight N UM P TS , press ENT and select 2. Press ENT . 6. Select F LUID L EVEL , press ENT , then select E MPTY L EVEL and press ENT . ...

  • Lowrance electronic LMS-480DF - page 29

    29 4. Press ↓ to select C A LIBRATE and press ENT . The Device Calibration menu will appear. 5. Highlight N UM P TS , press ENT and select 3 . Press ENT . 6. Make sure your tank is empty, then highlight F LUID L EVEL and press ENT . Select E MPTY LEVEL and press ENT . 7. Select C A LIBRATE and press ENT . The following message will appear: Empty ...

  • Lowrance electronic LMS-480DF - page 30

    30 1. Press MENU| MENU , use ↓ ↑ to select NMEA 2000 and press ENT . 2. Highlight B US S ETUP and press ENT , which will open the Bus Configu- ration menu. A list of network devices will be at the top of the page. 3. Select the desired EP -15 Fluid Level and press ENT . 4. Press ↓ to select C A LIBRATE and press ENT . The Device Calibration m ...

  • Lowrance electronic LMS-480DF - page 31

    31 1. After selecting Fuel Used as overlay data, fill up your tank and press MENU | MENU . 2. Select NMEA 2000 and press ENT . 3. Highlight F UEL M ANAG EM E NT and press ENT . Select T ANK L OCATION and press ENT . 4. Use ↑ ↓ to select the location (Port, Center or Starboard) of the en- gine interface you want to calibrate and press ENT . 5. H ...

  • Lowrance electronic LMS-480DF - page 32

    32 3. Highlight C ALIBRA TE T RI M and press ENT . The Device Calibration win- dow will appear with a list of Calibration Instructions. 4. Highlight S TART C ALIBRATION and press ENT . The following message will appear: Please fully raise the Engine Trim. 5. After engine trim has been fully raised, press ENT . The following message will appear: Ple ...

  • Lowrance electronic LMS-480DF - page 33

    33 Reset Calibration highlighted (left) . Reset Calibration confirmation window (right). To Reset Calibration: 1. Press MENU | MENU , select NMEA 2000 and press ENT . 2. Highlight F UEL M AN AGE ME NT and press ENT . 3. Highlight E NGINE S ELECT and press ENT . The Engine Select menu will appear with up to four options: All Engines, Port, Center an ...

  • Lowrance electronic LMS-480DF - page 34

    34 Notes ...

  • Lowrance electronic LMS-480DF - page 35

    35 Notes ...

  • Lowrance electronic LMS-480DF - page 36

    36 Visit our web site: Lowrance Pub. 988-0151-182 © Copyright 2006 All Rights Reserved Printed in USA 122206 Lowrance Electronics, In c. ...

Manufacturer Lowrance electronic Category GPS Receiver

Documents that we receive from a manufacturer of a Lowrance electronic LMS-480DF can be divided into several groups. They are, among others:
- Lowrance electronic technical drawings
- LMS-480DF manuals
- Lowrance electronic product data sheets
- information booklets
- or energy labels Lowrance electronic LMS-480DF
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lowrance electronic LMS-480DF.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lowrance electronic LMS-480DF, service manual, brief instructions and user manuals Lowrance electronic LMS-480DF. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lowrance electronic LMS-480DF.

A complete manual for the device Lowrance electronic LMS-480DF, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lowrance electronic LMS-480DF by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lowrance electronic LMS-480DF.

A complete Lowrance electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lowrance electronic LMS-480DF - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lowrance electronic LMS-480DF, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lowrance electronic LMS-480DF, that we can find in the current document
3. Tips how to use the basic functions of the device Lowrance electronic LMS-480DF - which should help us in our first steps of using Lowrance electronic LMS-480DF
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lowrance electronic LMS-480DF
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lowrance electronic LMS-480DF in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lowrance electronic LMS-480DF?

Use the form below

If you did not solve your problem by using a manual Lowrance electronic LMS-480DF, ask a question using the form below. If a user had a similar problem with Lowrance electronic LMS-480DF it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)