Panasonic PC8 - page 1
Building Block Video Ltd 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU, UK Tel: + 44 (0) 1323 842727 Fax: + 44 (0) 1323 842728 Support: + 44 (0) 1323 444600 www.bbvcctv.com Installation Guide PC8 Panasonic Protocol Converter ...
-
Panasonic PC8 - page 2
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 2/16 1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES UNPACKING Check packaging - Upon taking delivery of the unit, in spect the packaging for signs of damage. If damage has occurred, advise the ca rriers and/or the suppliers immediately. Check contents - Upon taking delivery of the unit, unpa ...
-
Panasonic PC8 - page 3
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 3/16 Overloading - Do not overload outlets and extension cord s, as this can result in fire or electric shock. Object and liquid entry - Never push objects of any kind in to the unit, as they may touch dangerous voltage points or short out parts that could result in fire or electric shock. Nev ...
-
Panasonic PC8 - page 4
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 4/16 Technical Specification Power Requirements 9Vdc 500mA Input 2 or 4 wire RS485 (switch selectable, SW3/8) Panasonic RS485 9600,N,8,1 or 19200,N,8,1 Outputs 8 * RS485, either 2 or 4 wire Maximum cable run approx 4000 Feet/1200m Facilities LED as power and data indication Other Outputs RS232 ...
-
Panasonic PC8 - page 5
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 5/16 2. INTRODUCTION GENERAL The unit is designed to allow control of 3 rd party domes from a Panasonic control system. It can be configured for either 2 wire, half duplex or 4 wire, full duplex telemetry. Site communications must be set to either 9600 or 19200 Baud, No parity, 8 data bits and ...
-
Panasonic PC8 - page 6
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 6/16 Internal view showing switches V12 Software Data IN 2 WIRE TRA TA TRB TB 4 WIRE TRA RA TRB RB RA TA RB TB Data OUT TRA = A/+ TRB = B/- SW5 Camera Ra nge RS232 DIAGNOSTICS PORT 12 34 56 78 VCL - 9600,N,8,1 SW4 Output Protocol 12 34 56 78 PELCO P – 9600,N,8,1 12 34 56 78 PELCO P – 4800, ...
-
Panasonic PC8 - page 7
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 7/16 Switch details main Starcard PCB Starcard PCB Switch es SW1 - RS485 line termination for outputs 1 - 4 ON = terminat ion ON (Default) SW1/1 & 1/2 = Output 1 termination SW1/3 & 1/4 = Output 2 termination SW1/5 & 1/6 = Output 3 termination SW1/7 & 1/8 = Output 4 termination ...
-
Panasonic PC8 - page 8
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 8/16 VCL TP protocol Function Panasonic Procedure Program preset 1 – 32 As normal Goto preset 1 – 32 As normal Enable Privacy zone 100 – 127 Program preset 64 Followed by goto preset 1 – 28 (1 = zone 100) Disable Privacy zone 100 – 127 Program preset 63 Followed by goto preset 1 – ...
-
Panasonic PC8 - page 9
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 9/16 Privacy Zones The dome’s 28 privacy zones can be set or cleared as follows: To SET a zone 1. Move the camera to show the scene that is to be blanked. 2. PROGRAM PRESET 64 : SET PRIVACY COMMAND 3. GOTO PRESET 1-28 : PRIVACY ZONE TO USE The screen will now be blank showing that t he priva ...
-
Panasonic PC8 - page 10
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 10/16 Pelco P specific functionality Manual proportional control of pan/tilt and zoom/focus/iris Support for preset 1 – 64 (preset 33 should not be used as this is a special Pelco preset) The dome menu can be displayed using the conventional key strokes used to access dome menus from the Pan ...
-
Panasonic PC8 - page 11
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 11/16 DENNARD protocol Function Panasonic Procedure Program preset 1 – 32 As normal – refer to Panasonic Manual Goto preset 1 – 32 As normal – refer to Panasonic Manual Display Menu As normal – refer to Panasonic Manual Use the Joystick to move the dome cursor and either the joystick ...
-
Panasonic PC8 - page 12
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 12/16 VICON protocol (4800 or 9600 baud) Function Panasonic Procedure Program preset 1 – 32 As normal – refer to Panasonic Manual Goto preset 1 – 32 As normal – refer to Panasonic Manual Display Menu As normal – refer to Panasonic Manual Use the Joystick to move t he dome cursor and ...
-
Panasonic PC8 - page 13
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 13/16 – blank for your notes – ...
-
Panasonic PC8 - page 14
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 14/16 – blank for your notes – ...
-
Panasonic PC8 - page 15
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 15/16 – blank for your notes – ...
-
Panasonic PC8 - page 16
Panasonic Protocol Converter M anual V10.2 5Mar 09 Page 16/16 Other products in the Panasonic range: PC8 Panasonic Protocol Converter – Designed to control 3 r d party domes from a Panasonic control system. RX550 Panasonic RS485 receiver – Controls 24V dc high/variable speed heads from a Panasonic RS485 telemetry control system. RX450 Panasonic ...