    VERTICAL FLOA T SUMP PUMP Model Model Model 95591 - .75 HP 95592 - 1 HP 95593 - 1.5 HP SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed exclusively by Harbor Freight T ools ® . 3491 Missi ...

  • Chicago Electric 95591-.75 HP - page 2

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 2 SPECIFICA TIONS Model 95591 Model 95592 Model 95593 Motor 1 15 V~ / 60 Hz / 4 A / 3/4 HP 1 15 V~ / 60 Hz / 5.5 A / 1 HP 1 15 V~ / 60 Hz / 6 A / 1.5 HP Power Switch T ype Automatic Float Switch Power Plug T ype 3-Prong / Grounded Self Priming Y es Maximum Pumping Capac ...

  • Chicago Electric 95591-.75 HP - page 3

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 3 ELECTRICAL SAFETY Grounded tools must be plugged into a GFCI (Ground Fault Circuit Interrupt- 1. er) outlet, properly installed, and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way . Do not use any a ...

  • Chicago Electric 95591-.75 HP - page 4

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 4 Store idle equipment out of reach of children and other untrained persons. 2. Electrically-powered products are dangerous in the hands of untrained users. Check for misalignment or binding of moving parts, breakage of parts, and 3. any other condition that may affect ...

  • Chicago Electric 95591-.75 HP - page 5

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 5 This Pump is designed to move clean or dirty water only . Do not pump water hotter than 95 degrees Fahrenheit. Make sure the discharge pipe 7. (not included) is secured to a solid surface to ensure the stability of the Pump. Make sure to position the Pump on a at, ...

  • Chicago Electric 95591-.75 HP - page 6

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 6 GROUNDING TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualied electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the g ...

  • Chicago Electric 95591-.75 HP - page 7

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 7 Double insulated tools may be used 2. in either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.) Extension Cords Grounded 1. tools require a three wire extension cord. Double Insulated tools can use either a two or three wir ...

  • Chicago Electric 95591-.75 HP - page 8

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 8 UNP ACKING When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight T ools at the number shown on the cover of this manual as soon as possible. ASSEMBL Y AND OPERA ...

  • Chicago Electric 95591-.75 HP - page 9

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 9 TO 1 15 VOL T , GROUNDED GFCI OUTLET 1/8” AIR BLEED HOLE BASE (25) DISCHARGE PIPE (NOT INCLUDED) CHECK V AL VE OR UNION (NOT INCLUDED) FIGURE E o 1-1/4” OR 1-1/2” NPT PVC 3. Connect the Discharge Pipe to the Base (25). NOTE: Make sure the Discharge Pipe is secur ...

  • Chicago Electric 95591-.75 HP - page 10

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 10 INSPECTION, MAINTENANCE, AND CLEANING W ARNING! Always shut off the electrical power to the GFCI outlet rst. Then, dis - connect the Pump’s Power Cord & Plug from the GFCI outlet prior to performing any inspection, maintenance, or cleaning procedures. Before ...

  • Chicago Electric 95591-.75 HP - page 11

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 1 1 T o clean the Impeller Cover and Impeller: 2. A clogged or dirty Impeller Cover or Impeller (28) will greatly reduce performance of the Pump. T o clean the Impel- ler Cover (31), spray the Cover with clean water . T o clean the Impeller , remove the nine Screws (32) ...

  • Chicago Electric 95591-.75 HP - page 12

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 12 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE T OOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR W ARRANTY OF ANY KIND TO TH ...

  • Chicago Electric 95591-.75 HP - page 13

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 13 ASSEMBL Y DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 31 Power Cord/Plug not shown. Note: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts. *Intern ...

  • Chicago Electric 95591-.75 HP - page 14

    SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 P AGE 14 LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod- uct is free from defects in materials and workmanship for the period ...

Manufacturer Chicago Electric Category Water Pump

Documents that we receive from a manufacturer of a Chicago Electric 95591-.75 HP can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 95591-.75 HP manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 95591-.75 HP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 95591-.75 HP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 95591-.75 HP, service manual, brief instructions and user manuals Chicago Electric 95591-.75 HP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 95591-.75 HP.

A complete manual for the device Chicago Electric 95591-.75 HP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 95591-.75 HP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 95591-.75 HP.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 95591-.75 HP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 95591-.75 HP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 95591-.75 HP, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 95591-.75 HP - which should help us in our first steps of using Chicago Electric 95591-.75 HP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 95591-.75 HP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 95591-.75 HP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 95591-.75 HP?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 95591-.75 HP, ask a question using the form below. If a user had a similar problem with Chicago Electric 95591-.75 HP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)