Manual IPSO 120

18 pages 0.59 mb
Download

Go to site of 18

Summary
  • IPSO 120 - page 1

    Refer to Inst allation manual for full instr uctions. 4-08-45R4 June 201 1 On-Pr emise Laundr y Planning Handbook 120 and 170 P ound T umbler s T hr ough Serial No . 0907000048 TMB1268C TMB1268C ...

  • IPSO 120 - page 2

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT © Published by pe rmission of the copyrig ht owner . All rights reserved. No part of the cont ents of this book may be reproduced or transmitted in any form or by any means without the expressed writte n consent of the publisher . 4-08-45 1 T a ble of Contents Tumblers – 12 ...

  • IPSO 120 - page 3

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT 2 4-08-45 T umbler s – 120 and 170 Introduction Model Identification Includes models with the follow ing control suffixes : TMB1268C TMB1268C Gas Stea m/Thermal Oil 120 Pound IPD120G2-IT120L IPD120G2-IT120N IPD120S2-IT1 20S IPD120S2-IT120T 170 Pound IPD170G2-IT170L IPD170G2- ...

  • IPSO 120 - page 4

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 3 TMB1298N 1 Serial Plate TMB1298N 120 POUND TUMBLER 1 1 170 POUND TUMBLER Conversion T able Multiply By T o Obt ain Multiply By T o Obt ain Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm Inch 25.4 ...

  • IPSO 120 - page 5

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 4 4-08-45 S pecifications and Dimensions N/A = Not Applicable Specifica tions 120 Pound 170 Pound Noise level measured during operation at operator position of 3.3 fe et (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor . 66 dBA 66 d ...

  • IPSO 120 - page 6

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 5 120 Pound T umbler Dimensions and Exhaust Outlet Locations Refer to Position and Level the T umbler to temporarily reduce th e he ights of these models. TMB2333N TMB2333N A B C D U V X H F Z Y I W TOP VIEW OF EXHAUST DUCT E G Cabinet Dimens ...

  • IPSO 120 - page 7

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 6 4-08-45 170 Pound T umbler Dimensions and Exhaust Outlet Locations Refer to Position and Level the T umbler to temporarily reduce the heights of these models. TMB2334N A B C D W H F Y X V TOP VI EW OF EXHAUST DUCT E G I Cabinet Dimensions M o d e l ...

  • IPSO 120 - page 8

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 7 Electric and Gas Connection Locations for Gas Models NOTE: These figures ar e approximate dimensions only . TMB1301N A C C A B D B D 120L/N 170L/N Models Electrical Co nnection Gas Connection ABCD D i a m e t e r Non-CE 120L/N 27.63 i n. (7 ...

  • IPSO 120 - page 9

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 8 4-08-45 Electric and Steam C onnection Locations for Steam Models TMB1461N A1 B1 120S 170S A2 B2 D E F A1 B1 B2 A2 D E F C C Models Ste am I nl et Diameter A1 A2 F 120S 3/4 in. NPT 35.875 in. (91 1 mm) 13.375 in. (340 mm) 82.75 in. (2102 mm) 170S 3 ...

  • IPSO 120 - page 10

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 9 Inst allation Pre-Inst allation Inspection Upon delivery , visually insp ect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have th e carrier n ...

  • IPSO 120 - page 11

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 10 4-08-45 T umbler Enclosure Figure 1 TMB2020N NOTE: Shaded areas indic ate adjacent structure. 1 0.5 in. (13 mm) re commended between machines for remo val or installation. 2 Allow 2-4 in. (51-102 mm) ope ning at top of machine to aid in removal or ...

  • IPSO 120 - page 12

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 11 Exhaust Requirement s Layout Whenever possible, install tumblers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Elbows and long vents tend to increase dryi ng time. Construction mu ...

  • IPSO 120 - page 13

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 12 4-08-45 NOTE: Exhaust ducts must be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in str ength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195 inch es (0.495 mm) th ...

  • IPSO 120 - page 14

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 13 Figure 2 NOTE: Do not install wire mesh or scr een in exhaust duct opening to avoid lint build-up or impacting proper discharge of air fr om tumblers. NOTE: Where exhaust duct pier ces a combustible wall or ceiling, the opening must be siz ...

  • IPSO 120 - page 15

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 14 4-08-45 Manifold V e nting While it is preferable to ex haust tumblers individually to the outdoors, a main collect or duct may be u sed if it is sized according to Figur e 4 and Figur e 5 . This illustration indicates minimum diameters, which sho ...

  • IPSO 120 - page 16

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 15 Figure 4 TMB2019N 1 NOTE: Where th e exhaust duct pierces a combustible wall or ce iling, the opening MUST be sized per local codes. 2 Outlet Duct Diameter 3 45° T ypical LK J I HG F E DC B A 3 1 2 ONE MANIFOLD ASSEMBLY Duct Stat io n 120 ...

  • IPSO 120 - page 17

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 an d 170 16 4-08-45 Figure 5 TMB2018N 1 NOTE: Where th e exhaust duct pierces a combustible wall or ce iling, the opening MUST be sized per local codes. 2 Outlet Duct Diameter 3 45° T ypical TMB2018N 1 2 3 LK J I L K J I CONTINUE TO A CONTINUE TO A TWO MANIF ...

  • IPSO 120 - page 18

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – 120 a nd 170 4-08-45 17 Electrical Requirement s Refer to T abl e 5 . NOTE: Minimum wire sizes ar e obtained from Canadian Electrical C ode and are in tended for use as a guideline only . Electrical connections should be made only by a qualified electrical contra ...

Manufacturer IPSO Category Washer

Documents that we receive from a manufacturer of a IPSO 120 can be divided into several groups. They are, among others:
- IPSO technical drawings
- 120 manuals
- IPSO product data sheets
- information booklets
- or energy labels IPSO 120
All of them are important, but the most important information from the point of view of use of the device are in the user manual IPSO 120.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IPSO 120, service manual, brief instructions and user manuals IPSO 120. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IPSO 120.

Similar manuals

A complete manual for the device IPSO 120, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IPSO 120 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IPSO 120.

A complete IPSO manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual IPSO 120 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IPSO 120, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IPSO 120, that we can find in the current document
3. Tips how to use the basic functions of the device IPSO 120 - which should help us in our first steps of using IPSO 120
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IPSO 120
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of IPSO 120 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning IPSO 120?

Use the form below

If you did not solve your problem by using a manual IPSO 120, ask a question using the form below. If a user had a similar problem with IPSO 120 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)