    12822-2-0903 Page 1 WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr op- erty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS • Do not try ...

  • Empire Comfort Systems RH-65C-1 - page 2

    Page 2 12822-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas ......................................................................................... ............ 4 Introduction .......... ...

  • Empire Comfort Systems RH-65C-1 - page 3

    12822-2-0903 Page 3 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in ...

  • Empire Comfort Systems RH-65C-1 - page 4

    Page 4 12822-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area ma ...

  • Empire Comfort Systems RH-65C-1 - page 5

    12822-2-0903 Page 5 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty ca ...

  • Empire Comfort Systems RH-65C-1 - page 6

    Page 6 12822-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.3 cm 1.3 cm 1.6 cm 1.3 cm 40-100 1/2" 1/2" 3/4" 1/2" 1. ...

  • Empire Comfort Systems RH-65C-1 - page 7

    12822-2-0903 Page 7 CLEARANCES Clearances: When facing the front of the room heater the minimum clearances to combustible construction (material) are the following: Left side 6 inches (152mm). Right side 6 inches (152mm). Recommend 18 inches ((457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above heat ...

  • Empire Comfort Systems RH-65C-1 - page 8

    Page 8 12822-2-0903 VENT SAFETY SHUT OFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system, can result in carbon mono ...

  • Empire Comfort Systems RH-65C-1 - page 9

    12822-2-0903 Page 9 1. STOP! Read the safety information above on this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any gas. T ...

  • Empire Comfort Systems RH-65C-1 - page 10

    Page 10 12822-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting whe ...

  • Empire Comfort Systems RH-65C-1 - page 11

    12822-2-0903 Page 11 Cleaning Pilot Burner After use, cleaning of the pilot burner may be required for the proper flame. The pilot orifice can be cleaned with high pressure air or by placing under running water. Pilot orifice must be dry before replacement. Use a pipe cleaner to clean inside the pilot after the pilot orifice has been removed. Remov ...

  • Empire Comfort Systems RH-65C-1 - page 12

    Page 12 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 23 11713 Pilot Tubing (RH-65-6) 24 RH-457 Air Shutter Bracket 25 P-267 Manifold Assembly (RH-50-6) 25 P-268 Manifold Assembly (RH-65-6) 26 P86-3.7mm Main Burner Orifice (RH-65-6 Nat) 26 P86-3.1mm Main Burner Orifice (RH-50-6 Nat) ...

  • Empire Comfort Systems RH-65C-1 - page 13

    12822-2-0903 Page 13 P AR TS VIEW RH-50 & RH-65 ...

  • Empire Comfort Systems RH-65C-1 - page 14

    Page 14 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 18 R-6126 Electrode and Wire Assembly 19 11712 Pilot Tubing (RH-50C-1) 19 11713 Pilot Tubing (RH-65C-1) 20 RH-457 Air Shutter Bracket 21 P-267 Manifold Assembly (RH-50C/CB-1) 21 P-268 Manifold Assembly (RH-65C-1) 22 P86-3.7mm Mai ...

  • Empire Comfort Systems RH-65C-1 - page 15

    12822-2-0903 Page 15 P AR TS VIEW RH-50C & RH-65C ...

  • Empire Comfort Systems RH-65C-1 - page 16

    Page 16 12822-2-0903 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward. 3. Align blower housing with blower cushion and use two, #10 x 1/2" (13mm )hex-he ...

  • Empire Comfort Systems RH-65C-1 - page 17

    12822-2-0903 Page 17 Attention : Wiring harness on blower is factory assembled and installed. If wiring harness becomes disassembled use the following steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly. 2. Attach (1) pin terminal from ...

  • Empire Comfort Systems RH-65C-1 - page 18

    Page 18 12822-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeb urg A v e. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: inf o@empirecomf ort.com WEB SITE: www .empirecomfort.com ...

Manufacturer Empire Comfort Systems Category Electric Heater

Documents that we receive from a manufacturer of a Empire Comfort Systems RH-65C-1 can be divided into several groups. They are, among others:
- Empire Comfort Systems technical drawings
- RH-65C-1 manuals
- Empire Comfort Systems product data sheets
- information booklets
- or energy labels Empire Comfort Systems RH-65C-1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Empire Comfort Systems RH-65C-1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Empire Comfort Systems RH-65C-1, service manual, brief instructions and user manuals Empire Comfort Systems RH-65C-1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Empire Comfort Systems RH-65C-1.

A complete manual for the device Empire Comfort Systems RH-65C-1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Empire Comfort Systems RH-65C-1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Empire Comfort Systems RH-65C-1.

A complete Empire Comfort Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Empire Comfort Systems RH-65C-1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Empire Comfort Systems RH-65C-1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Empire Comfort Systems RH-65C-1, that we can find in the current document
3. Tips how to use the basic functions of the device Empire Comfort Systems RH-65C-1 - which should help us in our first steps of using Empire Comfort Systems RH-65C-1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Empire Comfort Systems RH-65C-1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Empire Comfort Systems RH-65C-1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Empire Comfort Systems RH-65C-1?

Use the form below

If you did not solve your problem by using a manual Empire Comfort Systems RH-65C-1, ask a question using the form below. If a user had a similar problem with Empire Comfort Systems RH-65C-1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)