  • Thermo Products OH6FX072DV4 - page 1

    MO-4 62 ECN 4865-MA MADE IN U SA INSTALLATION AND OPERATION MANUAL FOR 2 – STAGE RIELLO BURNER ADDENDUM TO ( Mo – 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RE ...

  • Thermo Products OH6FX072DV4 - page 2

    2 Riello 2-stage burner specifications and applications: MODEL PART OD6 2-STAGE MTG. PLATE PART NO. 11700 MTG. PLATE GASKET PART NO. 330212 **NOZZLE SIZE .70 X 45 ° W NOZZLE PART NO. 380702 OIL PUMP PRESSURE 130 LOW 170 HIGH BURNER G5D BURNER PART NO. 380529 Table 8: Riello burner application THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOL ...

  • Thermo Products OH6FX072DV4 - page 3

    3 MOUNTING THE 2-STAGE RIELLO BURNER: It is necessary that the insulation gasket be placed between the mounting plate and the burner flange. The insulating gasket has six holes, which, if necessary, can be modified as shown. (see figure 14-1) Figure 14-1: Burner gasket and mounting Figure 14-2: Burner fixing and hinge assembly Verify that the insta ...

  • Thermo Products OH6FX072DV4 - page 4

    4 The setting of the fan output according to the installation should be done only through the air damper. Should you want to adjust the setting of the combustion head, with the burner running, turn the rod (1) with a 6mm wrench (2) as follows: TURN TO THE RIGHT: (SIGN + ) In order to increase the volume of air entering the combustion chamber and th ...

  • Thermo Products OH6FX072DV4 - page 5

    5 Figure 22 1 st STAGE ADJUSTMENT: Adjustment of air shutter: place the small plug (9) of the economizer (10) into the position I (Item A). In this way the burner will remain permanently in the 1 st stage. Loosen the nut (2), turn the screw (3) until the air shutter (1) reaches the position desired. Then lock the nut (2). Pressure regulation: this ...

  • Thermo Products OH6FX072DV4 - page 6

    6 ii. CARBON DIOXIDE (CO 2 ) OR OXYGEN (O 2 ): Take a CO 2 sample from flue passageway. It is possible to achieve readings of up to 14% CO 2 (or 2% O 2 ), but it is better to have a slightly lower CO 2 (or higher O 2 ) reading with zero smoke measured. To achieve a lower CO 2 reading, open the air band, or shutter, on the burner until zero smoke is ...

  • Thermo Products OH6FX072DV4 - page 7

    7 a. With the oil shut off, remove the 1/8 in. NPT threaded pipe pl ug located on the lower rear side of the oil pump, refer to Figure 22. Attach a pressure gage, c apable of measuring pressure in pounds per square inch gage, PSIG, in this opening, on the discharge side, of the oil pump. NOTICE: It may be necessary to remove the oil pump to attach ...

Manufacturer Thermo Products Category Cooktop

Documents that we receive from a manufacturer of a Thermo Products OH6FX072DV4 can be divided into several groups. They are, among others:
- Thermo Products technical drawings
- OH6FX072DV4 manuals
- Thermo Products product data sheets
- information booklets
- or energy labels Thermo Products OH6FX072DV4
All of them are important, but the most important information from the point of view of use of the device are in the user manual Thermo Products OH6FX072DV4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Thermo Products OH6FX072DV4, service manual, brief instructions and user manuals Thermo Products OH6FX072DV4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Thermo Products OH6FX072DV4.

A complete manual for the device Thermo Products OH6FX072DV4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Thermo Products OH6FX072DV4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Thermo Products OH6FX072DV4.

A complete Thermo Products manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Thermo Products OH6FX072DV4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Thermo Products OH6FX072DV4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Thermo Products OH6FX072DV4, that we can find in the current document
3. Tips how to use the basic functions of the device Thermo Products OH6FX072DV4 - which should help us in our first steps of using Thermo Products OH6FX072DV4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Thermo Products OH6FX072DV4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Thermo Products OH6FX072DV4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Thermo Products OH6FX072DV4?

Use the form below

If you did not solve your problem by using a manual Thermo Products OH6FX072DV4, ask a question using the form below. If a user had a similar problem with Thermo Products OH6FX072DV4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)