    MILLENNIUM Oxygen Gas Detector User Manual Models: MLP-A/AR/AD-ST1400-25 & (all available options) Part Number: MAN-0 060 Rev 04 August 2008 ...

  • Millennium Enterprises MLP-A/AR - page 2

    ...

  • Millennium Enterprises MLP-A/AR - page 3

    Net Safety Monitoring Inc I MPORTANT I NFOR MATION This ma nual is f or infor mational pu rposes only . Altho ugh every e ffor t has bee n made to ens ure the c orrec tness of t he infor mation, tec hnical inaccur acies may occur and pe riodic ch anges may be made without not ice. Net Saf ety Monitori ng Inc., assumes no r esponsibi lity for any er ...

  • Millennium Enterprises MLP-A/AR - page 4

    Net Safety Monitoring Inc T ABLE OF C ONTENTS Impo rta nt Inf orm ati on Warranty Contact Information Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 The Product ....................... ........................... .................. ........................... ....... 1 The Sensor ...... .... ...

  • Millennium Enterprises MLP-A/AR - page 5

    Net Safety Monitoring Inc Outputs ... ........................... .................. ........................... .................. .............. 18 Relays - Optional ........................ ............ ................ ............ ................. ........... ..... 18 Modbus ........... ........... ............ ................. ........... . ...

  • Millennium Enterprises MLP-A/AR - page 6

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 1 I NTR ODUCTI ON The Millenni um series is Net Sa fety's la test innov ation in a lin e of continuous ly evolvin g industria l gas detector s and sensors. The micr ocontrol ler based syst em provide s fast, accur ate and co ntinuous mon itoring of g ases in ex treme environ ments. T HE P RODUCT ...

  • Millennium Enterprises MLP-A/AR - page 7

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 2 STEP 1 — P LAN L OCATE C ONTROLLER /S ENSOR Prior t o the inst allation p rocess, a location plan f or placi ng the Contr oller and Sensor shoul d be developed. Althoug h there are no absolute ru les for determi ning the qu antity an d locati on of a sensor or controller , the following points s h ...

  • Millennium Enterprises MLP-A/AR - page 8

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 3 Figur e 2: Dimensional Drawings STEP 2 — I NSTALL U NPACK Carefully r emove all components f rom the pack aging. Check components against th e enclosed pac king list and inspe ct all compone nts for obvious damage such as broken or loose pa rts. If you f ind any compon ents missing o r damaged, n ...

  • Millennium Enterprises MLP-A/AR - page 9

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 4 Mount The Controll er is usually mounte d near eye-level an d be easily accessi ble for calibr ation and maintenanc e purposes . The Sensor s hould be plac ed where O2 may build up or where o ther gase s are li kely to bui ld up and di splace O2. Ensure al l device s are sec urely mo unted, taking i ...

  • Millennium Enterprises MLP-A/AR - page 10

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 5 Board Assembly There ar e three dif fer ent fixed boards, two optional relay boa rds and an o ptional Modb us board which mak e up the PCB Ass embly . Depending up on requir e ments, either a El ectromech anical or Solid S tate Re lay Board modu le can be u sed. Boards a re fiel d replaceabl e. Sim ...

  • Millennium Enterprises MLP-A/AR - page 11

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 6 Figur e 5: Wiring—Controlle r and Senso r Note: If the 4-20 mA signal is not used, connect a jumper betwe en the 4-20 term inal and th e COM ter mina l on the T e rmin al Boar d. S ENSOR AND C ONTROLLER WA R N I N G : Power to the unit must be OFF before wiring. Note: The Sensor may be fact ory in ...

  • Millennium Enterprises MLP-A/AR - page 12

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 7 S ENSOR S EPARATION Figur e 6: Wi ri ng — Sensor Separati on As the Sen sor must be l ocated in one location and the Con troller in a loca tion where it can be ea sily rea ched, it is often necessar y to “sepa rate” th e Controller and Sensor . The Sensor separat ion kit ( SEP) is composed o f ...

  • Millennium Enterprises MLP-A/AR - page 13

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 8 N ON -I SOLATED /I SOLATED W IR ING T ermi nal C onnection Figur e 7: Non-isolat ed T erminal Conne ction Figur e 8: Isolated T erminal Conne ction Current Outpu t T o set an isolated current output, sim ply move the Ju mper (sho rting j ack) t o the isolated c urrent po sition ( refer t o Figure 9, ...

  • Millennium Enterprises MLP-A/AR - page 14

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 9 R EMOTE R ESET The Mille nnium can be s et for r emote rese t. A normally ope n Push Button Switch must be connected bet ween the RST and the COM terminal s on the T erminal Boa rd and the Relay Option Latch S tatus mus t be set to Latching . Figur e 10: Remote Reset MODBUS T ERMINATION Devices a re ...

  • Millennium Enterprises MLP-A/AR - page 15

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 10 STEP 4 — O PERATE The Controll er faceplate c ontains most functi onal elements of the us er interface. Be low is a descripti on of that function ality . Figur e 12: Controll er Functional ity Status Red Slow Flash: Gas present Flast flash : Cal or Fault Solid: Overrange Pull Here Green Short Bl ...

  • Millennium Enterprises MLP-A/AR - page 16

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 11 RT U R eg i s t e r s Register 40001 = % output (read only) Register 40002 = R TU Statu s (read only) Register 40 101 = Reset l atched r elays (writ e) Calibration Button The Calibr ation Button p rovide s access to t he Millennium’ s Main Menu , which in turn allows ca librati on and options to ...

  • Millennium Enterprises MLP-A/AR - page 17

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 12 Magnetic R eed Sw itch The Magneti c Reed Switc h is provided to avoid opening the H ousing in a n environ ment where gas m ay be presen t. The Magnet ic Reed Switc h functions in the same manne r as the Cali bration Button but in a non- intrusi ve manner . Refer to Figure 12 , "Contr oller Fu ...

  • Millennium Enterprises MLP-A/AR - page 18

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 13 STEP 5 — C ALIBRATE C ALIBRATION P ROCEDUR E W ARNING: The calibra tion procedu re requir es about 5 minutes to c omplete. If gas is not ap plied at th e appropriat e time, a calib ration failure may occur (ref er to "Calibrat ion Failure" on page 14 for speci fic informati on). For ac ...

  • Millennium Enterprises MLP-A/AR - page 19

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 14 Calibrat ion Fail ure If the calibrat ion proce dure fails , the di splay shows Fai l Cal , the Stat us LED alter nates Red an d Green fl ashes and t he analog o utput changes bac k and fo rth from 3.0 to 3.3 mA. The unit remains in a failed st ate unti l manually reset. Aft er the Manu al Rese t, ...

  • Millennium Enterprises MLP-A/AR - page 20

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 15 R ELAY O PTIONS Use to se t the ala rm level, co il status and latch status f or the Low an d High relay s (Fau lt Ala rm is fi xed). The followin g table descri bes the default set tings for the sen sor . Ta b l e 4 : Default Re lay Settings Setting Relay Options There ar e two setting s for Rela ...

  • Millennium Enterprises MLP-A/AR - page 21

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 16 M ODBUS O PTIONS The digital RS- 485 Modbus R TU protocol is used. There are two Modbus options : Node Addres s and Baud Rat e. Node Address Each devi ce connect ed to the chai n must be as signed a u nique node a ddress (1 - 255). The last number in the add ress is selected firs t. St e p 1 : When ...

  • Millennium Enterprises MLP-A/AR - page 22

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 17 S ELECT D ISPLAY L ANGUAGE St e p 1 : After t he Restrict ed Menu the opt ion Select Disp lay Lan guage YES? displ ays. Press t he Calibra tion Button or use the Re ed Switch to select. The flas hing YES confir ms the select ion. St e p 2 : When the require d language displa ys ( Englis h , Espan ...

  • Millennium Enterprises MLP-A/AR - page 23

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 18 O UTP UTS Relays - Optional Note: The fa ult rel ay output i s not use d to acti vate an aut omatic shu tdown procedur e. The faul t output indicate s a potent ial problem wi th the Controll er not an alarm condition. St andard ele ctro-mech anical r elay outpu ts have Form C SPDT con tacts ra ted ...

  • Millennium Enterprises MLP-A/AR - page 24

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 19 H OW TO R ETURN E QUIPMENT A Materia l Return Author ization number is requi red in or der to re turn equipment . Please co ntact Net Safety Monit oring at (403) 219-0688 before return ing equipment or consu lt our Service Departmen t to possibly avoid return ing equipment. If you ar e required to ...

  • Millennium Enterprises MLP-A/AR - page 25

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 20 Rotate PCB Assembly 1. Remove the Control ler ’ s Housing Cover . 2. T urn the power t o the dete ctor of f. 3. Unscrew both the knobs marked "Pull Here ". 4. Lift Contro ller fa ceplate f rom Housing a nd allow to hang from ribbon cable . 5. Unscrew the tw o metal standof fs. 6. Carefu ...

  • Millennium Enterprises MLP-A/AR - page 26

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 21 Appendix B: R ESISTAN CE T ABLE IN OHMS Note: Resis tance sho wn is one way . This figure should be doub led when det ermining clos ed loo p resistance . Distance (F eet) A WG #20 A WG #18 A WG #16 A WG #14 A WG #12 A WG #10 A WG #8 1 0 0 1 . 0 20 . 6 40 . 4 00 . 2 50 . 1 60 . 1 0 0 . 0 6 2 0 0 2 ...

  • Millennium Enterprises MLP-A/AR - page 27

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 22 Appendix C: S PECIFICA TIONS S ENSOR S PECIFICATIONS C ONTROLLER S PECIFICATION SENSOR ELEMENT Oxygen O2 (ST1400 ) Operati ng T emperatur e Range -20°C to + 50°C (-4F to +12 2F) % 5 2 o t 0 n o i t c e t e D f o e g n a R 5 9 T o t s d n o c e s 5 1 < e m i T e s n o p s e R r a e y / s s o l ...

  • Millennium Enterprises MLP-A/AR - page 28

    N et Safety Monito ring Inc., 2 721 Hopewe ll Place NE C algary , Alberta, Canada T1 Y 7J7 T elepho ne: (40 3) 219- 068 8 Fax: (403 ) 219- 0694 E -mail: netsafe@net-safety .com w ww .netsafety .com ...

Manufacturer Millennium Enterprises Category Carbon Monoxide Alarm

Documents that we receive from a manufacturer of a Millennium Enterprises MLP-A/AR can be divided into several groups. They are, among others:
- Millennium Enterprises technical drawings
- MLP-A/AR manuals
- Millennium Enterprises product data sheets
- information booklets
- or energy labels Millennium Enterprises MLP-A/AR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Millennium Enterprises MLP-A/AR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Millennium Enterprises MLP-A/AR, service manual, brief instructions and user manuals Millennium Enterprises MLP-A/AR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Millennium Enterprises MLP-A/AR.

A complete manual for the device Millennium Enterprises MLP-A/AR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Millennium Enterprises MLP-A/AR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Millennium Enterprises MLP-A/AR.

A complete Millennium Enterprises manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Millennium Enterprises MLP-A/AR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Millennium Enterprises MLP-A/AR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Millennium Enterprises MLP-A/AR, that we can find in the current document
3. Tips how to use the basic functions of the device Millennium Enterprises MLP-A/AR - which should help us in our first steps of using Millennium Enterprises MLP-A/AR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Millennium Enterprises MLP-A/AR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Millennium Enterprises MLP-A/AR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Millennium Enterprises MLP-A/AR?

Use the form below

If you did not solve your problem by using a manual Millennium Enterprises MLP-A/AR, ask a question using the form below. If a user had a similar problem with Millennium Enterprises MLP-A/AR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)