  • Regency U38-NG - page 1

    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity ...

  • Regency U38-NG - page 2

    2 Regency U38 ULTIMATE Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models U38 ...

  • Regency U38-NG - page 3

    Regency U38 ULTIMATE Freestanding Gas Heater 3 T ABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ............................................. 14 Lighting Instructions ................................................ 14 Shutdown Instructions ............................................. 14 First Fire ....................... ...

  • Regency U38-NG - page 4

    4 Regency U38 ULTIMATE Freestanding Gas Stove This is a copy of the label that accompanies each ULTIMATE Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door. NOTE: Regency units are constantly being improved. Check the label on the unit and if ...

  • Regency U38-NG - page 5

    Regency U38 ULTIMATE Freestanding Gas Heater 5 INST ALLA TION BEFORE YOU ST ART Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following: IMPORT ANT : SA VE THESE INSTRUCTIONS The ULTIMATE Freestanding Gas Stove must be in ...

  • Regency U38-NG - page 6

    6 Regency U38 ULTIMATE Freestanding Gas Stove Side View Rear View Outside Air Through Rear of Pedestal Remove the blanking plate from the rear of the pedestal cover plate and bend the two tabs out 90 degrees. Pipe fresh air into the pedestal area by using duct pipe with a mesh grill at the outside termination. Attach the pipe to the tabs with screw ...

  • Regency U38-NG - page 7

    Regency U38 ULTIMATE Freestanding Gas Heater 7 INST ALLA TION VENTING This heater is a vented appliance and must be connected to a chimney/flue in accordance with the installation codes. Note: The rear pedestal cover plate is only required when outside air is being used. If using room air for combustion, remove this plate from the back of the pedes ...

  • Regency U38-NG - page 8

    8 Regency U38 ULTIMATE Freestanding Gas Stove 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. 6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should b ...

  • Regency U38-NG - page 9

    Regency U38 ULTIMATE Freestanding Gas Heater 9 INST ALLA TION Installer Notice: These instructions must be left with the appliance. Burner Orifice CONVERSION FROM NA TUAL GAS T O PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 730-969 Contains: Qty. Part # Description 1 910-018 ...

  • Regency U38-NG - page 10

    10 Regency U38 ULTIMATE Freestanding Gas Stove LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit contains the following: a) 02-65 Rear Log 902-267 b) 02-56 Middle Left Log 902-230 ...

  • Regency U38-NG - page 11

    Regency U38 ULTIMATE Freestanding Gas Heater 11 INST ALLA TION C)02-44 Pins on Rear Log Support A)02-65 B)02-56 3) Place Rear Log A)02-65 on the two pins on the rear log support. 4) Place the Middle Left Log B)02-56 on the two pins as shown. 5) Sprinkle some lava rock just in front of B) 02-56 on the burner holes. lava rock B)02-56 6) Place Front L ...

  • Regency U38-NG - page 12

    12 Regency U38 ULTIMATE Freestanding Gas Stove OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length: Note: Preferable if the thermostat is in- stalled on a ...

  • Regency U38-NG - page 13

    Regency U38 ULTIMATE Freestanding Gas Heater 13 WIRING This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to op- erate. However, a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not tou ...

  • Regency U38-NG - page 14

    14 Regency U38 ULTIMATE Freestanding Gas Stove OPERA TING INSTRUCTIONS 3) Wait five minutes to allow gas, that may have accumulated in the main burner com- partment, to escape. If you smell gas, fol- low the instructions on the front of this manual. If you don't smell gas continue on to the next step. 4) Turn the PILOT knob counterclockwise to ...

  • Regency U38-NG - page 15

    Regency U38 ULTIMATE Freestanding Gas Heater 15 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS ...

  • Regency U38-NG - page 16

    16 Regency U38 ULTIMATE Freestanding Gas Stove NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly nor- mal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are nor- mal operating sounds and ...

  • Regency U38-NG - page 17

    Regency U38 ULTIMATE Freestanding Gas Heater 17 MAINTENANCE 4) Remove the door catch plate. 5) Remove glass retainers on sides first (3 each side) then remove two center retain- ers. Note: Center glass retainers are glued to center glass. 6) Remove glass from extrusions. When re- moving center glass, leave white insulation in place. CLOTHING OR OTH ...

  • Regency U38-NG - page 18

    18 Regency U38 ULTIMATE Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the access panel on the rear wall of the firebox. Note: The unit MUST NOT be operated without the fan access panel se- curely in place and correctly sealed. IMPORTANT: These fans collect a lot of ...

  • Regency U38-NG - page 19

    Regency U38 ULTIMATE Freestanding Gas Heater 19 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. REMOVING VAL VE If your valve requires maintenance or replace- ment, follow these instructions: NOTE: Always shut off the gas supply before removing the valve. 1) Open front pedestal door and unhook chain. You ...

  • Regency U38-NG - page 20

    20 Regency U38 ULTIMATE Freestanding Gas Stove P ARTS LIST 24) 948-255 Door Latch c/w Hook 25) 910-250 Spill Switch 27) 910-233 Thermodisc - Fan Auto/On/Off 28) * Mounting Bracket - Fan Thermodisc 30) 750-010 Rear Panel 32) 730-565 Firebox Baffle 33) 560-535 False Top Assembly 34) 590-273 Flue Attachement Bracket 35) 590-930 Ult. 6" Flue Colla ...

  • Regency U38-NG - page 21

    Regency U38 ULTIMATE Freestanding Gas Heater 21 U38 BURNER & LOG ASSEMBL Y 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob - Fan Control Switch 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control Panel Decal 57) 650-220 Control Panel Plate 58) 910-330 Fan Sp ...

  • Regency U38-NG - page 22

    22 Regency U38 ULTIMATE Freestanding Gas Stove U38 DOOR ASSEMBLIES PARTS LIST 730-921 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic Paper 106) 940-323/P Side Glass 107) 936-2 ...

  • Regency U38-NG - page 23

    Regency U38 ULTIMATE Freestanding Gas Heater 23 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warran ...

  • Regency U38-NG - page 24

    Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date ...

Manufacturer Regency Category Stove

Documents that we receive from a manufacturer of a Regency U38-NG can be divided into several groups. They are, among others:
- Regency technical drawings
- U38-NG manuals
- Regency product data sheets
- information booklets
- or energy labels Regency U38-NG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Regency U38-NG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Regency U38-NG, service manual, brief instructions and user manuals Regency U38-NG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Regency U38-NG.

Similar manuals

A complete manual for the device Regency U38-NG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Regency U38-NG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Regency U38-NG.

A complete Regency manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Regency U38-NG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Regency U38-NG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Regency U38-NG, that we can find in the current document
3. Tips how to use the basic functions of the device Regency U38-NG - which should help us in our first steps of using Regency U38-NG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Regency U38-NG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Regency U38-NG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Regency U38-NG?

Use the form below

If you did not solve your problem by using a manual Regency U38-NG, ask a question using the form below. If a user had a similar problem with Regency U38-NG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)