    UNVENTED (VENT -FREE) GAS LOG HEA TER OWNER’S OPERA TION AND INST ALLA TION MANU AL Biltmore Split Oak, Seasonal Oak and Smoky Mountain Oak Logs V ariable Manually-Controlled Models Also Design-Certied As V ented Decorative Appliances 18", 24" AND 30" V ARIAbLE MANU ALL y -CONTROLLED MODELS CRL2718P A/NA CRL3124P A/NA 18", ...

  • Desa Tech CRL3124PA/NA - page 2

    www .desatech.com 1 13097-01L 2 SAFETy W ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam - age. Refer to this manual for correct installation and operational proce - dures. For assistance or additional information consult a qualified in - staller , service agency or the gas supplier . W ...

  • Desa Tech CRL3124PA/NA - page 3

    www .desatech.com 1 13097-01L 3 W ARNING: This product c o n t a i n s a n d / o r g e n e r a t e s chemicals known to the state of California to cause cancer or birth defects or other reproduc - tive harm. IMPORT ANT : Read this owner ’ s man ual carefu lly and co mple tel y b e f o r e t r y i n g t o a s s e m b l e , operate or service this ...

  • Desa Tech CRL3124PA/NA - page 4

    www .desatech.com 1 13097-01L 4 1. This appli ance is only fo r use with the ty pe of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supp ly ta nk(s ) out door s (p ropa ne/L P u nits only). 3. T o prevent performance pr ...

  • Desa Tech CRL3124PA/NA - page 5

    www .desatech.com 1 13097-01L 5 Figure 1 - V ent-Free Gas Log Heater (Logs May V ary by Model, Seasonal Oak Single Burner Model Shown) Base Grate Log Set Control Knob Burner Piezo Ignitor PRODUCT IDENTIFICA TION State of Massachusetts: The installa - tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers ...

  • Desa Tech CRL3124PA/NA - page 6

    www .desatech.com 1 13097-01L 6 Unusually tight construction is dened as construction where: a. wall s and ceilin gs expos ed to the out - side atmosphere have a continuous wa te r vapo r ret ar de r w it h a ra ti ng o f o ne perm (6x10 - 11 kg per pa-sec-m 2 ) o r les s with openings gasketed or sealed and b. weather stripping has been added o ...

  • Desa Tech CRL3124PA/NA - page 7

    www .desatech.com 1 13097-01L 7 Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2,560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Mul ti pl y the sp ac e volu me by 20 to de te rm in e the ...

  • Desa Tech CRL3124PA/NA - page 8

    www .desatech.com 1 13097-01L 8 INST ALLA TION W ARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creo - sote, ashes and loose paint by a qualified chimney cleaner . Creosote will ignite if highly heated. A dirt y chimney ue may create and distribute soot within house. Insp ect ...

  • Desa Tech CRL3124PA/NA - page 9

    www .desatech.com 1 13097-01L 9 INST ALLA TION AND CLEARANCES (V ent-Free Operation Only) W ARNING: Maintain the min imu m clea ran ces . If you can, pro vid e gr eat er clear anc es f rom oor , ceiling and adjoining wall. MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MA TERIALS Side W all 16", Ceiling 42" LOG SIZING REQUIREMENTS Minimum ...

  • Desa Tech CRL3124PA/NA - page 10

    www .desatech.com 1 13097-01L 10 INST ALLA TION Continued Noncombus - tible Material Distance (A) Requirements for Safe Installation 12" or more Noncombustible material okay . Between 8" and 12" 24" Models: Install replace hood accessory (GA6050, GA6052 or GA6053 see Accessories, page 38). 18" Model: Noncombustible mater ...

  • Desa Tech CRL3124PA/NA - page 11

    www .desatech.com 1 13097-01L 11 NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. W alls and mantels above the firebox may become hot to the touch. If installed properly , these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual. Figure 6 - Mi ...

  • Desa Tech CRL3124PA/NA - page 12

    www .desatech.com 1 13097-01L 12 INST ALLA TION Continued INST ALLING HEA TER BASE ASSEMBL Y CAUTI ON: Do not remo ve the da ta plat es att ac he d to the he ate r base assembly . The data plates contain important warranty and safety information. W ARNING: Y ou must secure this heater to replace oor . If not, heater will move when you adjust ...

  • Desa Tech CRL3124PA/NA - page 13

    www .desatech.com 1 13097-01L 13 INST ALLA TION Continued IMPORT ANT : Make sure the heater burners are level. If heater is not level, heater will not work properly . For thermostat models, avoid damage to ther mostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to o ...

  • Desa Tech CRL3124PA/NA - page 14

    www .desatech.com 1 13097-01L 14 CAUTION: Never connect heater direc tly to the propane/LP supply . This heater requires an ex ter na l re gu la to r (n ot sup pl ied ). Install the external regulator be- tween the heater and propane/ LP supply . W ARNING: Never connect natural gas replace to private (non-utility) gas wells . This gas is commonl ...

  • Desa Tech CRL3124PA/NA - page 15

    www .desatech.com 1 13097-01L 15 CAUTION: A void damage to reg ulato r . H old g as r egula tor with wrench when connecting it to gas piping and/or ttings. Figure 15 - Gas Connection * P urch ase the option al CSA de sig n-ce rti ed equipment shutoff valve from your dealer. ** Minimu m inlet pre ssure for purpose of input adjustment. 3" ...

  • Desa Tech CRL3124PA/NA - page 16

    www .desatech.com 1 13097-01L 16 INST ALLING LOGS CAUTION: After installa - tion and periodically thereafter , check to ensure that no ame comes in contact with any log. With the heater set to HI, check to see if ame s cont act any log. If so, reposition logs according to the log installation instructions in this manual. Flames contact - ing ...

  • Desa Tech CRL3124PA/NA - page 17

    www .desatech.com 1 13097-01L 17 INST ALLA TION Continued Figure 20 - Installing Middle Log #2 (CCL3924PT A/NT A Shown) Figure 21 - Installing Rear Log #3 (CCL3924PT A/NT A Shown) Middle Log (#2) T ab Burner U-Shaped Slot Hole in Grate Base Pins Burner Rear Log (#3) Figure 22 - Installing Crossover Log #4 (CCL3924PT A/NT A Shown) Middle Log (#2) Ba ...

  • Desa Tech CRL3124PA/NA - page 18

    www .desatech.com 1 13097-01L 18 INST ALLA TION Continued Single Burner Seasonal Oak Models CRL2718P A/NA, CRL3124P A/NA W ARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specically approved with this heater may result in property damage o r personal injury . The Seasonal Oak Log Set is a re ...

  • Desa Tech CRL3124PA/NA - page 19

    www .desatech.com 1 13097-01L 19 OPERA TION MANU ALL y -CONTROLLED MODELS LIGHTING INSTRUCTIONS W ARNING • If replace has glass doors, never operate this heater with glass doors closed. If you op - era te heate r wit h doo rs close d, heat buildup inside replace will cause glass to burst . Make sure there a re no obstruction s across openin ...

  • Desa Tech CRL3124PA/NA - page 20

    www .desatech.com 1 13097-01L 20 5. Slightly press and turn control knob coun - terclockwise to the PI LOT posit ion . Press in control knob for ve (5) seconds (see Figure 29). Note: Y ou may be running this heater for the rst time after hooking up to gas supply . If so, the control knob may need to be pressed in for 30 seconds or more. This ...

  • Desa Tech CRL3124PA/NA - page 21

    www .desatech.com 1 13097-01L 21 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a re or explosion may result causing property damage, per - sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting t he p il ot , f ol l ow t he se i ns t ru ct io n ...

  • Desa Tech CRL3124PA/NA - page 22

    www .desatech.com 1 13097-01L 22 5 . T urn control knob counterclockwise to the PILOT position. Press in control knob for ve (5) seconds (see Figure 31). Note: Y ou may be running this heater for the rst time after hooking up to gas supply . If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed ...

  • Desa Tech CRL3124PA/NA - page 23

    www .desatech.com 1 13097-01L 23 INSPECTING b URNERS • turn heater off (see T o T urn Off Gas to Appliance , page 2 0 [ manually -controll ed models] or page 22 [thermostat-controlled models]) • see T roubleshooting , page 25 Note: The pilot ame on natural gas units will have a slight curve, but ame should be blue and have no yellow or or ...

  • Desa Tech CRL3124PA/NA - page 24

    www .desatech.com 1 13097-01L 24 1. Shut off unit, including pilot. Allow unit to cool for at least thirty minutes. 2. Inspect burner , pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 35). 3. Blow air through the ports/slots and holes in the burner . 4. Check the injector holder located at the end of the burner tu ...

  • Desa Tech CRL3124PA/NA - page 25

    www .desatech.com 1 13097-01L 25 TROUbLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualied service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. POSS ...

  • Desa Tech CRL3124PA/NA - page 26

    www .desatech.com 1 13097-01L 26 TROUbLESHOO TING Continued POSSIBLE CAUSE 1 . Control knob not fully pressed in 2. Control kno b not press ed in long enough 3. Equi pme nt s huto f f va lve not fully open 4. P i l ot f l am e n o t t o u c hi n g thermocouple, which al - lows thermocouple to cool, causing pilot ame to go out. This problem could ...

  • Desa Tech CRL3124PA/NA - page 27

    www .desatech.com 1 13097-01L 27 TROUbLESHOO TING Continued POSSIBLE CAUSE 1 . Not enough combustion/ ventilation air 1. Turning control knob to HI or positi on 5 when burn er is cold 2. Air in gas line 3. Air passageways on heater blocked 4. Dirty or partially clogged burner orice 1. When heated, vapors from furni ture polish, wa x, carp et cle ...

  • Desa Tech CRL3124PA/NA - page 28

    www .desatech.com 1 13097-01L 28 TROUbLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Fol - low the gas supplier ’ s instructions. • ...

  • Desa Tech CRL3124PA/NA - page 29

    www .desatech.com 1 13097-01L 29 OPTIONAL POSITIONING OF THERMOST A T SENSING bULb Thermostat Sensing Bulb Gas V alve Assembly Mounting Bracket Figure 37 - Location of Gas V alve Assembly and Thermostat Sensing Bulb Figure 38 - Adhesive-backed Mounting Clip Figure 39 - Removing Thermostat Sensing Bulb Thermostat Screw Retaining Clamp Thermostat Sen ...

  • Desa Tech CRL3124PA/NA - page 30

    www .desatech.com 1 13097-01L 30 thoroughly . Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 43). Slide the thermostat sensing bulb into the clip. IMPORT ANT : Do not crimp capilla ...

  • Desa Tech CRL3124PA/NA - page 31

    www .desatech.com 1 13097-01L 31 FIREPLACE HOOD GA6050 (Black) GA6052 (Brass) GA6053 (Antique Brass) For all models. Helps deect heat away from mantel or wall above replace. P ARTS CENTRAL These Parts Centrals are privately owned businesses. They have agreed to support our customer ’ s needs by providing original replacement parts and acces ...

  • Desa Tech CRL3124PA/NA - page 32

    www .desatech.com 1 13097-01L 32 P ARTS THERMOST A TICALL Y -CONTROLLED BIL TMORE SPLIT OAK MODELS CCL3018PT A, CCL3018NT A, CCL3924PT A AND CCL3924NT A 9 23 23 23 10 8 13 14 15 4 5 1 2 Peg positions vary according to model. 1 1 12 19 21 21 24 22 20 6 7 25 18 23 17 16 7 ...

  • Desa Tech CRL3124PA/NA - page 33

    www .desatech.com 1 13097-01L 33 P ARTS THERMOST A TICALL Y -CONTROLLED BIL TMORE SPLIT OAK MODELS This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 35 of this manual KEY NO. P ART NO. DESCRIPTION QTY . 1 1 1 1340-02 Front Log (#1) • • 1 1 1 1340-03 Fro ...

  • Desa Tech CRL3124PA/NA - page 34

    www .desatech.com 1 13097-01L 34 P ARTS V ARIABLE MANUALL Y -CONTROLLED SEASONAL OAK MODELS CRL2718P A, CRL2718NA, CRL3124P A AND CRL3124NA 4 12 6 10 11 6 7 6 5 1 8 9 15 14 16 19 21 18 13 19 17 20 18 2 3B 3A ...

  • Desa Tech CRL3124PA/NA - page 35

    www .desatech.com 1 13097-01L 35 P ARTS V ARIABLE MANUALL Y -CONTROLLED SEASONAL OAK MODELS This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts, below . KEY NO. P ART NUMBER DESCRIPTION QTY . CRL2718P A CRL2718NA CRL3124P A CRL3124NA 1 1 13551-01 1 13551-01 1 13551-0 ...

  • Desa Tech CRL3124PA/NA - page 36

    1 13097-01 Rev . L 09/08 NOT A UPC 113097 01 DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www .desatech.com 1-866-672-6040 WARRANTy kEEP THIS WARRANTy DESA HEA TING, LLC LIMITED WARRANTIES New Products Standard W arranty: DESA Heating, LLC warrants this new product and any parts thereof to be free from defects in material and wor ...

Manufacturer Desa Tech Category Heating System

Documents that we receive from a manufacturer of a Desa Tech CRL3124PA/NA can be divided into several groups. They are, among others:
- Desa Tech technical drawings
- CRL3124PA/NA manuals
- Desa Tech product data sheets
- information booklets
- or energy labels Desa Tech CRL3124PA/NA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa Tech CRL3124PA/NA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa Tech CRL3124PA/NA, service manual, brief instructions and user manuals Desa Tech CRL3124PA/NA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa Tech CRL3124PA/NA.

A complete manual for the device Desa Tech CRL3124PA/NA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa Tech CRL3124PA/NA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa Tech CRL3124PA/NA.

A complete Desa Tech manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa Tech CRL3124PA/NA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa Tech CRL3124PA/NA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa Tech CRL3124PA/NA, that we can find in the current document
3. Tips how to use the basic functions of the device Desa Tech CRL3124PA/NA - which should help us in our first steps of using Desa Tech CRL3124PA/NA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa Tech CRL3124PA/NA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa Tech CRL3124PA/NA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa Tech CRL3124PA/NA?

Use the form below

If you did not solve your problem by using a manual Desa Tech CRL3124PA/NA, ask a question using the form below. If a user had a similar problem with Desa Tech CRL3124PA/NA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)