    Easy-Fax 90si Secure Facsimile Gateway Reference Guide Virginia, USA Toll Free: 1-877-951-9800 Email: help@gwfs.com http://www.gwfs.com Revision 3.3 7 January 2005 GateWay Fax Systems, Inc. www. .com GWFS ...

  • GateWay Fax Systems Easy-Fax 90si - page 2

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 2/13 CONTENTS 1.0 Configuring your STU-III for the 90si 3 1.1 AT&T Security Plus 3 1.2 AT&T, Lucent and General Dynamics 1100 (*1) 4 1.3 AT&T, Lucent, General Dynamics 1900 SDD (*1) 5 1.4 GE/RCA 2400 6 1.5 GE 9600 7 1.6 Motorola SECTEL 1000/1500 8 1.7 Moto ...

  • GateWay Fax Systems Easy-Fax 90si - page 3

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 3/13 1.0 Configuring your STU-III for the 90si The most common cause of 90si operational problems are attributed to not having the STU-III's Secure Data port configured for "Synchronous" operation. The following sections provide step- by-step instructio ...

  • GateWay Fax Systems Easy-Fax 90si - page 4

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 4/13 1.2 AT&T, Lucent and General Dynamics 1100 Objective: To set Secure Data Mode for 9.6 Kbps, Full Duplex, Synchronous. While On or Off-Hook: Press Display MENU MAIN MENU / Secure Voice NEXT MAIN MENU / Secure Data SELECT Ex. SD:9.6 FDX, ASYNC / 2.4 Full Duplex ...

  • GateWay Fax Systems Easy-Fax 90si - page 5

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 5/13 1.3 AT&T / Lucent / General Dynamics SDD 1900 Objective: To set Secure Data Mode for 9.6 Kbps, Full Duplex, Synchronous, 8 Data Bits. While On or Off-Hook, READY on or off: Press Display MENU MAIN MENU / Secure Data SELECT Ex. SD:9.6 H, ASYNC,8 / 2.4 Full Dup ...

  • GateWay Fax Systems Easy-Fax 90si - page 6

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 6/13 1.4 GE / RCA 2400 Objective: To set Secure Data Mode for 2.4 Kbps, Full Duplex, Synchronous. While On-Hook (to permanently change set-up): Press Display PROGRAM RCA STU-III Type I SET-UP (back of unit) Do You Want To Set term Options? * (YES) Do You Want To Set S ...

  • GateWay Fax Systems Easy-Fax 90si - page 7

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 7/13 1.5 GE 9600 Objective: To set Secure Data Mode for 9.6 Kbps, Full Duplex, Synchronous. While On-Hook (to permanently change set-up): Press Display MENU / DELETE GE STU-III Type I (then...) View KSD or ID? # (NO) Configure Terminal? * (YES) Control is Local/Change ...

  • GateWay Fax Systems Easy-Fax 90si - page 8

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 8/13 1.6 Motorola SECTEL 1000 / 1500 Objective: To set Secure Data Mode for 2.4/9.6 Kbps, Full Duplex, Synchronous. While Off-Hook and in CLEAR mode: Press Display PRGM Ex. DATA = 2400 ASYNC SCROLL (until...) DATA = SYNCHRONOUS PRGM PRGM (current call status displayed ...

  • GateWay Fax Systems Easy-Fax 90si - page 9

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 9/13 1.7 Motorola SECTEL MMT 1500 Objective: To set Secure Data Mode for 9.6 Kbps, Full Duplex, Synchronous. While On-Hook: Press Display PRGM PRGM (enunciator in display) SCROLL (until...) USER OPTIONS # TO SELECT # PRESS SCROLL TO CONTINUE SCROLL (until...) Ex. DATA ...

  • GateWay Fax Systems Easy-Fax 90si - page 10

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 10/13 1.8 L-3 Communications STE Objective: To set Secure Data Mode for 9.6 Kbps, Synchronous. For STE’s with software V2.3 or earlier. While On-Hook: Press Display MODE SECURE DATA: A9.6 (Asynchronous, 9.6 Kbps) CHANGE Secure Data Asynchronous CHANGE Secure Data Sy ...

  • GateWay Fax Systems Easy-Fax 90si - page 11

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 11/13 2.0 90si Status LED's There are two LED's located on the front panel of the 90si. The following three sections explain what the various LED states indicate. 2.1 Power-up Note: Before applying power to the 90si, make sure that all cables are securely co ...

  • GateWay Fax Systems Easy-Fax 90si - page 12

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 12/13 3.0 Glossary of Secure Facsimile Terms Listed below are definitions of words and terms used in the 90si User's and Reference Guides. Broadcast : A signaling option in the Mil-Std-161 mode in which the transmitting device does not look for any acknowledgemen ...

  • GateWay Fax Systems Easy-Fax 90si - page 13

    90si Reference Guide GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 13/13 STU-III : Secure Telephone Unit Generation Three. STU-IIIA : Secure Telephone Unit Generation Three Version A. US Secure telephone that can connect with a STU-IIB. ...

Manufacturer GateWay Fax Systems Category Fax Machine

Documents that we receive from a manufacturer of a GateWay Fax Systems Easy-Fax 90si can be divided into several groups. They are, among others:
- GateWay Fax Systems technical drawings
- Easy-Fax 90si manuals
- GateWay Fax Systems product data sheets
- information booklets
- or energy labels GateWay Fax Systems Easy-Fax 90si
All of them are important, but the most important information from the point of view of use of the device are in the user manual GateWay Fax Systems Easy-Fax 90si.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals GateWay Fax Systems Easy-Fax 90si, service manual, brief instructions and user manuals GateWay Fax Systems Easy-Fax 90si. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product GateWay Fax Systems Easy-Fax 90si.

A complete manual for the device GateWay Fax Systems Easy-Fax 90si, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use GateWay Fax Systems Easy-Fax 90si by users. Manuals are usually written by a technical writer, but in a language understandable to all users of GateWay Fax Systems Easy-Fax 90si.

A complete GateWay Fax Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual GateWay Fax Systems Easy-Fax 90si - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the GateWay Fax Systems Easy-Fax 90si, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the GateWay Fax Systems Easy-Fax 90si, that we can find in the current document
3. Tips how to use the basic functions of the device GateWay Fax Systems Easy-Fax 90si - which should help us in our first steps of using GateWay Fax Systems Easy-Fax 90si
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with GateWay Fax Systems Easy-Fax 90si
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of GateWay Fax Systems Easy-Fax 90si in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning GateWay Fax Systems Easy-Fax 90si?

Use the form below

If you did not solve your problem by using a manual GateWay Fax Systems Easy-Fax 90si, ask a question using the form below. If a user had a similar problem with GateWay Fax Systems Easy-Fax 90si it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)