  • Spectra Watermakers CF-0.5-10 - page 1

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 24 REPLACEMENT PARTS Model Replacement Part SF-MT-0.5-10 .5 micron MicroTec™ Sediment Filter CF-0.5-10 .5 micron Carbon Block Pre-Filter MEM-90,150 90 or150 gpd Membrane (2) 150gpd membranes make 300 GPD FR-90 Flow Restrictor fo ...

  • Spectra Watermakers CF-0.5-10 - page 2

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 2 No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of Spectr ...

  • Spectra Watermakers CF-0.5-10 - page 3

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 22 Membrane Output Calculation Example What is the expected GPD from a 75 GPD System at 40 psi pressure and 60°F water temperature? PCF = 40 ÷ 60 = 0.666 TCF = 0.754 (from Table 1) Expected GPD = 75 × 0.666 × 0.754 = 37.7 GPD ...

  • Spectra Watermakers CF-0.5-10 - page 4

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 4 SYSTEM SPECIFICATIONS Sediment Pre-Filter 0.5 micron MicroTec™ sediment pre-filter Carbon Filter 0.5 micron carbon block pre-filter RO Membrane Type Thin-Film Composite (TFC) DI Cartridges M AX C AP DI ™ SilicaBuster™ DI R ...

  • Spectra Watermakers CF-0.5-10 - page 5

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 20 CHOOSING A MOUNTING LOCATION When considering a location for the installation of the RO System, consider the following factors: Light Sources 1. Most of the components of this system are plastic and are subject to damage by ult ...

  • Spectra Watermakers CF-0.5-10 - page 6

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 6 METERING AND DIAGNOSITCS This SpectraPure purification system has been fully equipped with sufficient instrumentation to make monitoring and troubleshooting an easy process. The provided pressure gauge is used to determine the t ...

  • Spectra Watermakers CF-0.5-10 - page 7

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 18 TROUBLESHOOTING GUIDE FOR RO/DI SYSTEMS 1. Low production rate: a. plugged pre-filters. i. Replace pre-filters. b. low water temperature. ii. Heat feed water OR use higher GPD membrane. c. low line pressure. iii. Use booster pu ...

  • Spectra Watermakers CF-0.5-10 - page 8

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 8 1. IMPORTANT: During the initial rinse-up of the M AX C AP RO/DI ™, a large ionic load is presented to the downstream DI cartridges. Be sure to rinse up all new MAXCAP DI ™ with the downstream cartridge removed. This rinsing ...

  • Spectra Watermakers CF-0.5-10 - page 9

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 16 RO MEMBRANE REPLACEMENT 1. Turn off the water supply to the RO system. Place the system where the membrane housing is easily accessible. 2. Remove the black tubing from the membrane feed push-fitting by depressing the collar on ...

  • Spectra Watermakers CF-0.5-10 - page 10

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 10 Fig. B: Flow Restrictor Tables (For 4:1 Concentrate to Product Ratio) FR - 90 ml./min. gpd in. cm. 269 102 1 2.5 233 88 2 5.1 213 81 3 7.6 198 75 4 10.2 183 69 5 12.7 175 67 6 15.2 164 62 7 17.8 154 58 8 20.3 148 56 9 22.9 141 ...

  • Spectra Watermakers CF-0.5-10 - page 11

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 14 M AX C AP RO/DI ™ MAINTENANCE AND REPLACEMENT Procedure: 1. When the reading on the right-hand TDS meter (set to “IN”) displays 75% of the reading on the left-hand TDS meter (set to “OUT”), it is time to replace the M ...

  • Spectra Watermakers CF-0.5-10 - page 12

    SpectraPure SpectraPure®Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281 ® 12 6. Re-insert the yellow tubing into its push-fitting in the RO membrane as follows: a.) Moisten the O-ring seal inside the concentrate outlet fitting by dripping a few drops of clean water into the fitting. b.) Grasp the yellow ...

Manufacturer Spectra Watermakers Category Water System

Documents that we receive from a manufacturer of a Spectra Watermakers CF-0.5-10 can be divided into several groups. They are, among others:
- Spectra Watermakers technical drawings
- CF-0.5-10 manuals
- Spectra Watermakers product data sheets
- information booklets
- or energy labels Spectra Watermakers CF-0.5-10
All of them are important, but the most important information from the point of view of use of the device are in the user manual Spectra Watermakers CF-0.5-10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Spectra Watermakers CF-0.5-10, service manual, brief instructions and user manuals Spectra Watermakers CF-0.5-10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Spectra Watermakers CF-0.5-10.

A complete manual for the device Spectra Watermakers CF-0.5-10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Spectra Watermakers CF-0.5-10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Spectra Watermakers CF-0.5-10.

A complete Spectra Watermakers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Spectra Watermakers CF-0.5-10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Spectra Watermakers CF-0.5-10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Spectra Watermakers CF-0.5-10, that we can find in the current document
3. Tips how to use the basic functions of the device Spectra Watermakers CF-0.5-10 - which should help us in our first steps of using Spectra Watermakers CF-0.5-10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Spectra Watermakers CF-0.5-10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Spectra Watermakers CF-0.5-10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Spectra Watermakers CF-0.5-10?

Use the form below

If you did not solve your problem by using a manual Spectra Watermakers CF-0.5-10, ask a question using the form below. If a user had a similar problem with Spectra Watermakers CF-0.5-10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)