    VISTA-10 SE N7227V5 5/97 Installation Instructions • Installation Instructions • Installation Instructions Security System THIS ISSUE INCLUDES THE NEW “QED” (QUICK ENROLLMENT OF DEVICES) PROCEDURE FOR 5800 SERIES TRANSMITTERS ...

  • ADEMCO N7227V5 - page 2

    – 2 – RECOMMENDATIONS FOR PROPER PROTECTION The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in ...

  • ADEMCO N7227V5 - page 3

    – 3 – TABLE OF CONTENTS Section 1. GENERAL DESCRIPTION ................................ ................................ ............................ 9 Section 2. INSTALLING THE CONTROL ................................ ................................ ................... 11 Mounting the Cabinet ................................ ................. ...

  • ADEMCO N7227V5 - page 4

    – 4 – Section 5. WIRELESS (RF) ZONE EXPANSION (5700 & 5800 RF SYSTEMS), CONT’D To Either Temporarily or Permanently Remove a Zone From the System (5800 System) ................................ ................................ ................................ ............ 37 Deleting a Transmitter Serial Number From a Zone in ✱ 56 Mode ( ...

  • ADEMCO N7227V5 - page 5

    – 5 – Section 13. SEQUENTIAL MODE (For 5800 Series Wireless Transmitters) ................................ ............................ 61 Section 14. SYSTEM COMMUNICATION ................................ ................................ .................... 64 Report Code Formats ................................ ............................... ...

  • ADEMCO N7227V5 - page 6

    – 6 – LIST OF FIGURES Figure 1. Installing the Cabinet Lock ................................ ................................ ............. 11 Figure 2. Installing The PC Board Alone, or (if used), With a 4204 Relay Unit ............. 12 Figure 3. Installing the PC Board & RF Receiver Together in the Cabinet .................. 12 Figure 4. ...

  • ADEMCO N7227V5 - page 7

    – 7 – HOW TO USE THIS MANUAL This manual is written to accommodate both the new and the experienced installer of Ademco products. A general description of the entire system is located in the first section of this manual. This includes the various features available and the optional peripheral devices that the system can support. This manual is ...

  • ADEMCO N7227V5 - page 8

    – 8 – CONVENTIONS USED IN THIS MANUAL MAIN SECTION TITLES ARE SHOWN IN REVERSE TYPE U L These notes include specific information which must be followed if you are installing this system for a UL Listed application. These notes include information that you should be aware of before continuing with the installation, and which, if not observed, co ...

  • ADEMCO N7227V5 - page 9

    – 9 – Section 1. GENERAL DESCRIPTION The VISTA–10SE is a control that supports up to 22 zones, using basic hard-wired, and/or wireless, plus remote keypads. Basic Hardwired Zones (1–6) Provides 6 basic hardwired zones having the following characteristics: • Zones 1-6 response time is 300–500 milliseconds. • Zone 3 programmable High Sp ...

  • ADEMCO N7227V5 - page 10

    – 10 – Optional Output Relays • Up to 4 relays using one 4204 Relay Module . • Actions programmable to respond to zone activity or manual keypad entries. Optional Phone module • Supports the Ademco 4285 Phone module . • Provides access to the system via on premises or off-premises phones for arming, disarming, etc., plus control of rela ...

  • ADEMCO N7227V5 - page 11

    – 11 – Section 2. INSTALLING THE CONTROL This section provides instructions for mounting the control cabinet, and installing the cabinet lock (if used). Also included in this section are instructions for the following: • Installing the main PC board (and 4204 Relay Unit, if used). • Mounting the RF Receiver board (if used) in the cabinet. ? ...

  • ADEMCO N7227V5 - page 12

    – 12 – 4204 Relay Unit (if installed in cabinet) 1 . Insert self-tapping screws (provided) in two adjacent raised cabinet tabs. Leave the heads projecting 1/8". 2 . Hang the unit on the screw heads via two of the slotted holes at the rear of its housing, as shown in Figure 2. 3 . The 4204's cover can be left off if the unit's DIP ...

  • ADEMCO N7227V5 - page 13

    – 13 – Installing the Control and RF Receiver Circuit Boards Together in the Cabinet 1 . Hang two short (black) mount ing clips (provided with receiver) on the raised cabinet tabs, as shown in Detail B in Figure 3. 2 . Insert the top of the receiver board (removed from its own case as de - scribed in its in struc tions) into the slots at the to ...

  • ADEMCO N7227V5 - page 14

    – 14 – Wiring The AC Transformer No. 1321 Wire the No. 1321 transformer to terminals 1 and 2 on the control board. See wiring table below for wire gauge to use. WIRING TABLE Distance of Transformer Wire Gauge From the Control Panel To Use Up to 50 feet # 2 0 50–100 feet # 18 100–250 feet # 1 6 Wiring to the AC Transformer must not exceed 25 ...

  • ADEMCO N7227V5 - page 15

    – 15 – Section 3. INSTALLING REMOTE KEYPADS This section lists the wired keypads that may be used and provides instructions for wiring and mounting the keypads. A preliminary check-out procedure is also provided to ensure that the connected keypads are functioning properly in the system. Keypads That May Be Used • Fixed-Word Display: 4127, 41 ...

  • ADEMCO N7227V5 - page 16

    – 16 – KEYPADS BLACK RED GREEN YELLOW 4 5 6 CONTROL TERMINALS KEYPAD CONNECTOR CABLE ↓ 7 Figure 5. Keypad Connections To The Control Board Mounting the Keypads 1. Make sure addressable type keypads ( 4137AD, 5137AD, 6128, 6137 , 6138, and 6139) are set to non-addressable mode (address 31), which is the factory default setting. Refer to the in ...

  • ADEMCO N7227V5 - page 17

    – 17 – SUPPLEMENT ARY POWER SUPPL Y + – CONTROL TERMINAL STRIP AUX AUX. DA T A DA T A – + IN OUT 45 6 7 IMPORT ANT : MAKE THESE CONNECTIONS DIRECTL Y TO SCREW TERMINALS AS SHOWN. TO KEYP AD RED WIRE TO KEYP AD BLK WIRE TO KEYP AD YEL WIRE TO KEYP AD GRN WIRE TO KEYP AD BLK WIRE TO KEYP AD RED WIRE TO KEYP AD GRN WIRE TO KEYP AD YEL WIRE Fig ...

  • ADEMCO N7227V5 - page 18

    – 18 – Section 4. BASIC HARD-WIRED ZONES 1–6 This section provides general information for the hard-wired zones in the system, plus specific instructions for installing 4-wire smoke/combustion detectors. Also included is a procedure for programming the hard-wired zones. Installing the Hard-Wired Zones Common Characteristics for Zones 1–6 ? ...

  • ADEMCO N7227V5 - page 19

    – 19 – Compatible System Sensor 4-Wire Smoke/Combustion Detectors 1412 4-wire ionization products of combustion detector. 2412 4-wire photoelectric smoke detector. 2412TH 4-wire photoelectric smoke detector w/135 ° F (57 ° C) heat detector. A77–716B EOL relay module (supervisory module for wired 4-wire fire zone). 2112/24T Low-profile 4-wir ...

  • ADEMCO N7227V5 - page 20

    – 20 – Zone Types 00 = Zone Not Used 01 = Entry/Exit #1 02 = not used 03 = Perimeter 04 = Interior Follower 05 = Trouble Day/Alarm Night 06 = 24 Hr Silent 07 = 24 Hr Audible 08 = 24 Hr Aux 09 = Fire 10 = Interior w/Delay 20 = Arm Stay* 21 = Arm-Away* 22 = Disarm* 23 = No Alarm Response * 5800 RF Systems only When the display shows the zone type ...

  • ADEMCO N7227V5 - page 21

    – 21 – When you have programmed all the hard-wired zones and Panic keys satisfactorily, exit ✱ 56 interactive mode at the Enter Zn Num . prompt by entering [ 0 ] [ 0 ] as the next zone number. Then exit the programming mode by keying ✱ 99 . See the special notes below, then proceed to the check-out procedure that follows. Special Notes on Z ...

  • ADEMCO N7227V5 - page 22

    – 22 – Section 5. WIRELESS (RF) ZONE EXPANSION (5700 AND 5800 RF SYSTEMS) This section provides the following information: • Wireless systems available. • Installing the wireless receiver. • Installing the 5800TM Module. • Programming for the wireless receiver. • Setup and installation of the wireless transmitters (5700 or 5800 series ...

  • ADEMCO N7227V5 - page 23

    – 23 – The supervision for a particular transmitter in the 5800 system may be turned off by entering it as a "UR" (unsupervised RF) type, as described later. 5800 series transmitters have built-in tamper protection and will cause a “CHECK” condition to be annunciated if covers are removed. Each transmitter is also supervised for l ...

  • ADEMCO N7227V5 - page 24

    – 24 – 4 3 2 1 ON OFF ▲ ▲ MOUNTING HOLES INTERFERENCE INDICA TOR LED CIRCUIT BOARD DIP SWITCH PLUG & SOCKET INSERT IN RIGHT -HAND TERMINALS ANTENNAS YELLOW RED BLACK GREEN } TO CONTROL ’S REMOTE KEYP AD CONNECTION POINTS. EACH RECEIVER MUST BE ON INDIVIDUAL HOME RUN. WIRING OPENING KNOCKOUT AREA FOR SURF ACE WIRING 5882 LOCA TION { TO ...

  • ADEMCO N7227V5 - page 25

    – 25 – Setting the DIP Switches on 5700 Series Transmitters Set the DIP switches on each 5700 series transmitter to the appropriate zone/ID number and House ID. Refer to the Compatible 5700 Series Transmitters table on a following page in this section for zone numbers and programming information for each particular transmitter. Refer also to DI ...

  • ADEMCO N7227V5 - page 26

    – 26 – DIP SWITCH T ABLES FOR 5700 RF SYSTEM WIRELESS DEVICES HOUSE ID (1 SHOWN) HOUSE ID (1 SHOWN) HOUSE ID (1 SHOWN) 1 2 345 6 UP DN 1 2 345 UP DN 1 2 345 6 7 8 UP DN 1 2 345 6 7 8 9 1 0 UP DN 5706/5707 SMOKE DETECTORTRANSMITTER 5775 PIR DETECTOR/TRANSMITTER HOUSE ID SWITCH SETTING FOR ALL DEVICES EXCEPT 5716 5727 KEYP AD DEVICE ID DIP SWITCH ...

  • ADEMCO N7227V5 - page 27

    – 27 – Compatible 5700 Series Transmitters Model Product Zone/ID # Description 5701 Panic Transmitter 62 or 63 • Programmable for either silent or audible 24-hour alarm. 5706 Photoelectric Smoke 48–55 • One-piece smoke detector with Detector built-in transmitter . • Built-in UL Listed 85dB piezo electric alarm sounder and audible low ba ...

  • ADEMCO N7227V5 - page 28

    – 28 – Programming the Control For a 5700 Wireless System 1 . With at least one two-line Custom English keypad wired and set to address 31 (default), power up the system temporarily by plugging the AC transformer (previously wired to the control) into a 120VAC outlet. 2 . Enter data field programming mode: Installer Code + 8 + 0 . 3 Set data fi ...

  • ADEMCO N7227V5 - page 29

    – 29 – Data field ✱ 22 RF SYSTEM TYPE, must have been programmed for a 5700 RF system (“1”). Also, the House ID should have been entered in field ✱ 24, and all 5700 transmitters set to the same House ID. 4. Press ✱ 56. (Zone Programming Mode) Use this mode to program zone numbers, zone types, and alarm report codes for all 5700 wirele ...

  • ADEMCO N7227V5 - page 30

    – 30 – 1 0 . Mark the zone number on the transmitter. 1 1 . After the transmitter has been entered into the system, press [ ✱ ] to continue. Typical summary display Zn ZT – RC In: L 20 03 – 3 C RF: – A summary of the programmed values for the selected zone will now be displayed If all is okay, press [ ✱ ] for the next display. P r ogr ...

  • ADEMCO N7227V5 - page 31

    – 31 – • If the keypad does not beep, re-orient or move the transmitter to another location. Usually a few inches in either direction is all that is required. 3 . Mount the transmitter according to the instructions provided with the transmitter. 4 . Exit the GO/NO GO test mode by entering Installer Code + ( OFF ). You should now proceed to ? ...

  • ADEMCO N7227V5 - page 32

    – 32 – Compatible 5800 Series Transmitters Enter As Input Model Product Device Type Description 5801 Wireless Panic UR or RF • Has four pushbuttons, each with a Transmitter unique input (loop) code. • Programmable responses (e.g., Panic, Arm–Stay, Arm–Away, Disarm, etc. 5802 Pendant BR Only • Has single pushbutton. (Personal Emergency ...

  • ADEMCO N7227V5 - page 33

    – 33 – Compatible 5800 Series Transmitters (Continued) Enter As Input Model Product Device Type Description 5819 Shock Processor RF • Connects to externally mounted Transmitter inertia-type shock detector (not supplied). • Has built-in tampered cover switch. • Has 3 unique input (loop) codes: Loop 1: Terminals for a wired, N.C. sensor loo ...

  • ADEMCO N7227V5 - page 34

    – 34 – 3. ✱ 24 . RF HOUSE ID CODE The House ID identifies a 5827 or 5827BD Wireless keypad if it is used (enter 01–31). The wireless keypads should be set to the same ID. If no wireless keypad is to be used, leave as “00”. Enrolling 5800 Transmitters Into The System There are two methods that may be used to enroll transmitters. The firs ...

  • ADEMCO N7227V5 - page 35

    – 35 – ZN ZT – R C In: L 10 00 – 00 R F: 1 5 . A display will appear, showing a summary of that zone's programming. If the zone is not programmed, the display will appear as shown here. If checking a zone's programming, and it is programmed satisfactorily, press [#] to back up one step and enter another zone number, if desired. Ot ...

  • ADEMCO N7227V5 - page 36

    – 36 – 10 Input S/N: L A002-4064 1 The system will enroll the serial number of the first transmitter heard, add the loop number entered to this serial number, display the serial and loop numbers, and cause the keypad to beep twice. If the serial and loop number combination is already present in the system, a single long beep will be heard from ...

  • ADEMCO N7227V5 - page 37

    – 37 – To Either Temporarily Or Permanently Remove A Zone From The System (5800 System). 1 . Enter the programming mode: Key Installer Code + 8 + 0 and press [ ✱ ][5][6]. 2 . Enter the zone number and press [ ✱ ]. A summary display will appear. 3. Press [ ✱ ] again. 20 Z o ne T y p e No t Use d 0 0 4 . The “ Zone Type ” prompt will ap ...

  • ADEMCO N7227V5 - page 38

    – 38 – Go/No Go Test (5700/5800 RF Systems) Before mounting transmitters permanently, conduct Go/No Go tests to verify adequate signal strength and reorient or relocate transmitters if necessary. During this mode, wireless receiver gain is reduced by 50%. Testing in this mode assists in determining good mounting locations for the transmitters a ...

  • ADEMCO N7227V5 - page 39

    – 39 – Section 6. RELAY OUTPUT DEVICES Relay Device Basics Relays are programmable switches that can be used to perform many different functions. They can be used to turn lights on and off, control sounders, or for status indications. In this system, each relay must be programmed as to how to act (ACTION), when to activate (START), and when to ...

  • ADEMCO N7227V5 - page 40

    – 40 – The letter(s) in parentheses after each function described below, such as (A) after ACTION, are those that appear in the various summary displays of programmed data during programming. ACTION (A) The "ACTION" of the relay is how the relay will respond when it is activated by the "START" programming. You may want the r ...

  • ADEMCO N7227V5 - page 41

    – 41 – STOP (STP): The "STOP" programming determines when and under what conditions the relay will be de-activated. The following options are available: A) 1. RESTORE ZONE LIST (ZL) . If a "ZONE LIST" is used as the “Stop” event, the relay will de-activate when all the zones in that list restore from a previous fault, tr ...

  • ADEMCO N7227V5 - page 42

    – 42 – Output Relay Displays Enter Relay No. (00 = Quit) 01 Upon pressing ✱ 80, this screen will appear. Enter the Relay Number 01, 02, 03, or 04 for a 4204 (or 00 to end these entries). Press the [ ✱ ] key to continue. The [ ✱ ] key is used to accept an entry and advance to the next prompt. The [#] key is used to revert back to the last ...

  • ADEMCO N7227V5 - page 43

    – 43 – The display then returns again to the first screen so that the next relay number to be programmed can be entered, or enter [0][0] to end relay programming. Previously entered data can be reviewed by pressing [#] [8] [0]. After the relay number is chosen, press [ ✱ ] to go to the next screens. This is a review mode only, and data cannot ...

  • ADEMCO N7227V5 - page 44

    – 44 – Section 7. 4285 PHONE MODULE This section provides instructions for mounting the 4285 Phone module , wiring the Phone module and for programming the system for phone access via the Phone module. Installing the Phone module General Information The 4285 Phone module is an add-on accessory for the VISTA–10SE that permits access to the sec ...

  • ADEMCO N7227V5 - page 45

    – 45 – 1 . Make 12V (+) and (–) and data in and data out connections from the Phone module to the control, using the connector cable supplied with the Phone module (see Figure 10). Color Lead Terminal On Control * GREEN DATA IN (terminal 6) BLACK AUX – (terminal 4) R E D AUX + (terminal 5) YELLOW DATA OUT (terminal 7) * These are the same c ...

  • ADEMCO N7227V5 - page 46

    – 46 – 4285 WIRING NOTES: 1 . Wire the 4285 Phone module exactly as shown, using a direct-connect cord and RJ31X jack. 2 . If Touch-tones are not heard when pressing keys following phone access to the security system via an on-premises phone , try reversing the pair of wires connected to terminals 3 & 4 on the 4285, and the pair of wires co ...

  • ADEMCO N7227V5 - page 47

    – 47 – Programming The Control For Phone Access 1 . With at least one addressable keypad (but set to the non-addressable mode, address 31) connected to the keypad terminals on the control, power up the system temporarily. If you had previously connected the AC transformer to the control panel, you need only plug in the transformer (to 120VAC ou ...

  • ADEMCO N7227V5 - page 48

    – 48 – Checking the Operation of the 4285 Phone module To Check Phone module Operation From an On-Premises Phone 1 . Pick up phone and enter the programmed 2-digit phone code (entered in field ✱ 26, VOICE (PHONE) MODULE ACCESS CODE) . Annunciation of a system status report should automatically start. See the User’s Guide accompanying the Ph ...

  • ADEMCO N7227V5 - page 49

    – 49 – Section 8. EXTERNAL SOUNDERS This section provides a list of compatible sounders , connection information for an external sounder and programming procedures for those options that affect the operation of external sounders . Compatible Sounders Ademco AB-12M 10” Motorized Bell & Box Motor bell & box. UL Grade A. 100mA current dr ...

  • ADEMCO N7227V5 - page 50

    – 50 – This control complies with NFPA requirements for temporal pulse sounding o f fire notification appliances. Temporal pulse sounding for a fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . . repeated. Sounder Connections The VISTA–10SE provides a 12 VDC output which can power external alarm s ...

  • ADEMCO N7227V5 - page 51

    – 51 – Section 9. LONG RANGE RADIO General Information Check availability of Model 7720PLUS or 7820 long range radio. If output to long range radio is selected, all messages that are programmed to go to the primary telephone line receiver will also be sent to the 7720PLUS or 7820 long range radio. These messages will be in Contact ID format (no ...

  • ADEMCO N7227V5 - page 52

    – 52 – Section 10. AUDIO ALARM VERIFICATION (AAV) UNIT General Information An Audio Alarm Verification (AAV) module, such as the Eagle 1241 , is an add - on accessory that permits voice dialog between an operator at a central station and a person at the alarm installation, for the purpose of alarm verification. Alarm reports must be programmed ...

  • ADEMCO N7227V5 - page 53

    – 53 – TERMINALS ON CONTROL EARTH GROUND 17 18 19 20 ➡ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PREMISES ANSWERING MACHINE AND PHONES ANSWERING MACHINE ▲ TIP RING RJ31X JACK PLUG DIRECT CONNECT CORD ➧ TIP RING (TIP) (RING) ▲ ▲▲ INCOMING TELCO LINE BROWN (TIP) GRA Y (RING) ▲ ON MODEL EAGLE SECURITY 1241 GND V+ GND 1 2 3 RELA Y 1, SHO ...

  • ADEMCO N7227V5 - page 54

    – 54 – Section 11. FINAL POWER UP In previous sections, you made temporary power connections for the purpose of programming and testing. This section provides information about final power-up procedures and battery size calculations. Earth Ground Connections The designated earth ground terminal (21) must be terminated in a good earth ground for ...

  • ADEMCO N7227V5 - page 55

    – 55 – Making the Battery Connections 1 . Use the battery standby formula (shown on previous page) to select the appropriate battery for the installation. Remember, when calculating the battery size needed, you must add the 100mA drawn by the control itself to the total Auxiliary current draw in the worksheet below. Do not connect the battery u ...

  • ADEMCO N7227V5 - page 56

    – 56 – Section 12. ALPHA DESCRIPTOR PROGRAMMING This section provides instructions for programming Alpha descriptors This is recommended for systems using Alpha keypads, and necessary if a 4285 Phone module is used. Alpha descriptors cannot be displayed on fixed-word keypads. If using a 4285 Phone module, select from those words in the Alpha Vo ...

  • ADEMCO N7227V5 - page 57

    – 57 – 4. Press “0” (No).* The system will then automatically display the default descriptor for zone 1. * The procedure for adding custom words to the built-in vocabulary will be found later under “Adding Custom Words”. Default Descriptor ↓ ✱ Z N 01 Z ON E 01 If a descriptor was not en tered previously for zone 1, the default descr ...

  • ADEMCO N7227V5 - page 58

    – 58 – ✱ Z N 0 1 BAC K D OOR A ↑ Flashing Cursor if “6” is pressed (system ready for next word). 9. Press “6” to accept the selected word. Note: If these are the only words you are using for the descriptor, press “ 8 ” instead of “ 6 ” to save them in memory. 1 0 . The two words in our example have now been entered. Note, ho ...

  • ADEMCO N7227V5 - page 59

    – 59 – 4 . For selection of the next word (e.g., DOOR), repeat step 3, as follows: Press key [3] until the first letter of the next word appears (e.g., "D"). Then press [6] to display the first available word beginning with that letter (e.g. DAUGHTERS). Press [3] repeatedly until the de sired word (e.g., DOOR) appears. To ac cept the ...

  • ADEMCO N7227V5 - page 60

    – 60 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) NOTE : Some rarely-used words appearing in previously published lists have been deleted from the list below. Use only this list for selecting zone descriptors. 000 (Word Space) A • 001 AIR • 002 ALARM 004 ALLEY 005 AMBUSH • 006 AREA • 00 7 APARTMENT • 009 ATTIC 010 AUDIO B ? ...

  • ADEMCO N7227V5 - page 61

    – 61 – Section 13. SEQUENTIAL MODE (for 5800 Series Wireless Transmitters) (Use this mode only after all other zone information has been programmed, including transmitter loop numbers). There are two methods of enrolling – you can enroll each transmitter into the system as you are entering the zone information in field ✱ 56 (the procedure w ...

  • ADEMCO N7227V5 - page 62

    – 62 – 10 Input S/N: L Axxx xxxx 5 . This prompt is displayed when the system has found the next zone which needs to be enrolled. The system will respond to the first serial number transmitted. A serial number may be enrolled by one of two methods: a) Enter the 7 digit serial number printed on the transmitter or b) Activate the transmitter by f ...

  • ADEMCO N7227V5 - page 63

    – 63 – 7 . The system will search for the next zone that does not have a serial number associated with it. If one is found, the prompt in step 5, along with the appropriate zone number, will be displayed. Follow steps 5 and 6 for the remaining wireless zones. En te r Zn Nu m . (00 = Qui t ) 15 8 . After all wireless zones have been displayed, w ...

  • ADEMCO N7227V5 - page 64

    – 6 4 – Section 14. SYSTEM COMMUNICATION This section provides an explanation of formats this system accommodates for reporting alarms and other system conditions to the central station. The process of a successful transmission consists of both the method of communication between the control panel and the central station receiver and the actual ...

  • ADEMCO N7227V5 - page 65

    – 65 – 3+1/4+1 3+1/4+1 Report Standard Expanded 4+2 Alarm SSS(S) A SSS(S) A SSSS AZ AAA(A) Z Trouble SSS(S) T SSS(S) T SSSS Tt TTT(T) t Bypass SSS(S) B SSS(S) B SSSS Bb BBB(B) b AC Loss SSS(S) E SSS(S) E SSSS EA C EEE(E) A C Low Batt SSS(S) L SSS(S) L SSSS LL B LLL(L) L B Open SSS(S) O SSS(S) O SSSS OU OOO(O) U Close SSS(S) C SSS(S) C SSSS CU C ...

  • ADEMCO N7227V5 - page 66

    – 66 – TABLE OF CONTACT ID EVENT CODES Code Definition 1 10 Fire Alarm 12 1 Duress 1 2 2 Alarm, 24-hour Silent 1 23 Alarm, 24-hour Audible Panic 1 31 Alarm, Perimeter, Burg. 1 32 Alarm, Interior, Burg. 1 34 Alarm, Entry/Exit, Burg. 1 35 Alarm, Day/Night, Burg. 1 50 Alarm, 24 Hour Auxiliary 3 01 AC Power 3 02 Low System Battery/Battery Test Fail ...

  • ADEMCO N7227V5 - page 67

    – 6 7 – Press ✱ 45 PHONE SYSTEM SELECT Enter 1 digit (default = 0) If Central Station Receiver is not on WATS line: 0 = Pulse Dial, 1 = Tone Dial. If Central Station Receiver is on WATS line: 2 = Pulse Dial, 3 = Tone Dial. Press ✱ 46 REPORT FORMAT, PRIMARY/SECONDARY Determines which format is to be used to report to the central station. 0 = ...

  • ADEMCO N7227V5 - page 68

    – 68 – Example 1. Pager displays: 12 3 4 – 911 – 004  This indicates that Subscriber No. 1234’s system is reporting an Alarm (911), due to zone 4 being faulted (004). Example 2. Pager displays: 12 34 – 001 – 005 This indicates that Subscriber No. 1234’s system is reporting an opening (001) by User 5 (005). Note that no restore re ...

  • ADEMCO N7227V5 - page 69

    – 69 – Press ✱ 63 LOW BAT REPORT CODE This will be sent when a low battery condition exists in the system’s standby battery. Note: Connection to the standby battery is checked every 3 minutes (CSFM requirement). Press ✱ 64 TEST REPORT CODE This is sent periodically to test that the communicator and phone lines are operational (frequency o ...

  • ADEMCO N7227V5 - page 70

    – 70 – Press ✱ 74 LOW BAT RESTORE REPORT CODE This is sent when a system low battery condition is restored to normal. Press ✱ 75 RF XMTR. LOW BATTERY RESTORE CODE This is sent when a transmitter that previously sent in a low battery message has sent a message indicating it no longer has a low battery condition. Press ✱ 92 NUMBER OF REPORT ...

  • ADEMCO N7227V5 - page 71

    – 71 – Section 15. TESTING THE SYSTEM Test Procedure After installation is completed, the System should be carefully tested, as follows: 1 . With the System in the disarmed state, check that all zones are intact. If a NOT READY message is displayed, press the [ ✱ ] key to display the faulted zone(s). Restore faulted zone(s) if necessary, so t ...

  • ADEMCO N7227V5 - page 72

    – 72 – To test the wireless part of the system and the RF Receiver, perform the two following tests: Transmitter Sniffer Mode and Go/NoGo Test Mode . TRANSMITTER SNIFFER MODE Make sure the system is disarmed before trying to enter this mode. Key Installer code + # + 3. This initiates a procedure that will check that all 5700 series transmitters ...

  • ADEMCO N7227V5 - page 73

    – 73 – Section 16. SYSTEM OPERATION Security Codes Installer Code The installer programs the 4-digit Installer Code initially as part of the programming procedure. The factory default Installer code is " 4-1-1-1 ", but may be changed in field ✱ 20. Note: The Installer Code is defined as User #1. The Installer code is the only code t ...

  • ADEMCO N7227V5 - page 74

    – 74 – Keypad Functions General Information Note that if you enabled QUICK ARM (field ✱ 21), the [#] key can be pressed instead of entering the security code, for any of the arming procedures (Away, Stay, Instant, Maximum, etc.). The security code is always required, however, when disarming the system. NOTE: The “Quick Arm” feature will f ...

  • ADEMCO N7227V5 - page 75

    – 75 – Panic Keys There are three individual panic keys or, on some keypads, panic key pairs. If programmed, they can be used to manually initiate alarms and send a report to the central station. Each key (or key pair) can be individually programmed for 24-hour Silent, Audible, Personal or Fire Emergency responses. The panic function is activat ...

  • ADEMCO N7227V5 - page 76

    – 76 – • The " EXIT ALARM " display, etc. will also result if an alarm from an exit or interior zone occurs within two minutes after the end of an exit delay. In any of the previous cases, use a second OFF sequence (code plus OFF key) to clear the display. Trouble Conditions (See Troubleshooting Guide also) General Information The w ...

  • ADEMCO N7227V5 - page 77

    – 77 – Section 17. TROUBLESHOOTING GUIDE SYSTEM (including Wireless) SYMPTOM POSSIBLE CAUSE REMEDY 1 . Transmitter signal not received at 4281/5881. 1a. Transmitter or 4281/5881 not properly pow- ered. 1b. If Transmitter is 5827/5827BD , house ID code not set in field ✱ 24, or transmitter not set to same house code set in that field. 1 c. Tra ...

  • ADEMCO N7227V5 - page 78

    – 78 – TROUBLESHOOTING GUIDE (continued) SYMPTOM POSSIBLE CAUSE REMEDY 7 . Intrusion alarm for no ap- parent reason. (continued) 7d. Magnetic contacts improperly connected or wire broken. 7e. Entry door programmed as “Instant” 7 f . Loose fitting door or window being rattled by wind or vibrations. 7d . Check wiring connections. Be sure wire ...

  • ADEMCO N7227V5 - page 79

    – 79 – CONTACTING TECHNICAL SUPPORT PLEASE, Before you call Technical Support , be sure you: • READ THE INSTRUCTIONS! • Check all wiring connections. • Determine that the power supply and/or backup battery are supplying proper voltages. • Verify your programming information where applicable. • Note the proper model number of this prod ...

  • ADEMCO N7227V5 - page 80

    – 80 – Section 18. SPECIFICATIONS & ACCESSORIES Specifications VISTA–10SE SECURITY CONTROL 1. Physical: 12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm) 2. Electrical: VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No. 1321/TF2 (in U.S.A.) RECHARGEABLE BACK-UP BATTERY: 12VDC, 4AH (Gel type). Charging Voltag ...

  • ADEMCO N7227V5 - page 81

    – 81 – 6127 REMOTE KEYPAD 1. Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm). 2. Electrical: Voltage Input: 12VDC; Current Drain: 20mA. 3. Interface Wiring: Same as 4127. 6128 REMOTE KEYPAD 1. Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm). 2. Electrical: Voltage Input: 12VDC; Current Drain ...

  • ADEMCO N7227V5 - page 82

    – 82 – Accessories (Compatible Devices) No. 1321 16.5VAC, 25VA Plug-In Trans former (in U.S.A.) No. 1321CN 16.5VAC, 25VA Plug-In Trans former (in Canada) Sounders Ademco AB-12M 10” Motorized Bell & Box Motor bell & box. UL Grade A. 100mA current draw. Ademco 1011BE12M 10” Motorized Bell & Box Motor bell & box. UL Listed. 100 ...

  • ADEMCO N7227V5 - page 83

    – 83 – REGULATORY AGENCY STATEMENTS FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, th ...

  • ADEMCO N7227V5 - page 84

    – 84 – UL NOTICES 1 . This is a "Grade A" residential system. 2 . The 4285 Phone module and 7720PLUS or 7820 Long Range Radios have not been UL tested and cannot, therefore, be used in a UL installation. 3 . The Entry Delay (field ✱ 38) cannot be greater than 45 seconds for UL installations. 4 . The maximum number of reports per arm ...

  • ADEMCO N7227V5 - page 85

    – 85 – CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to ...

  • ADEMCO N7227V5 - page 86

    – 86 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is sub ject to compromise or failure to warn for a variety of rea sons. For example: • Intrusion d ...

  • ADEMCO N7227V5 - page 87

    – 87 – TO DETERMINE TOTAL STANDBY LOAD ON BATTERY, ADD 100mA TO TOTAL OF AUX. POWER OUTPUT AND REMOTE KEYPAD CURRENTS. USE UL LISTED LIMITED ENERGY CABLE FOR ALL CONNECTIONS CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING JURISDICTION ...

  • ADEMCO N7227V5 - page 88

    N7227V4 5/97 ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workma ...

Manufacturer ADEMCO Category Security Camera

Documents that we receive from a manufacturer of a ADEMCO N7227V5 can be divided into several groups. They are, among others:
- ADEMCO technical drawings
- N7227V5 manuals
- ADEMCO product data sheets
- information booklets
- or energy labels ADEMCO N7227V5
All of them are important, but the most important information from the point of view of use of the device are in the user manual ADEMCO N7227V5.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ADEMCO N7227V5, service manual, brief instructions and user manuals ADEMCO N7227V5. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ADEMCO N7227V5.

A complete manual for the device ADEMCO N7227V5, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ADEMCO N7227V5 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ADEMCO N7227V5.

A complete ADEMCO manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ADEMCO N7227V5 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ADEMCO N7227V5, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ADEMCO N7227V5, that we can find in the current document
3. Tips how to use the basic functions of the device ADEMCO N7227V5 - which should help us in our first steps of using ADEMCO N7227V5
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ADEMCO N7227V5
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ADEMCO N7227V5 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ADEMCO N7227V5?

Use the form below

If you did not solve your problem by using a manual ADEMCO N7227V5, ask a question using the form below. If a user had a similar problem with ADEMCO N7227V5 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)