  • First Alert SC9120B - page 1

    1 INTRODUCTION Thank you for choosing BRK Brands, Inc. for your Smoke and Carbon Monoxide Alarm needs. Y ou have purchased a state-of-the-art Smoke & CO Alarm designed to pr ovide you with early warning of a fire or Carbon Monoxide. Key featur es include: Smoke & Carbon Monoxide Combination Alar m. One alarm pr otects against two deadly hou ...

  • First Alert SC9120B - page 2

    2 INST ALLA TION WHERE TO INST ALL THIS ALARM Minimum coverage for Smoke Alarms , as recommended by the National Fire Protection Association (NFP A), is one Smoke Alarm on every floor , in every sleeping area, and in every bedroom (See “Regulatory Information For Smoke Alarms” for details on the NFP A recommendations). For CO Alar ms, the Natio ...

  • First Alert SC9120B - page 3

    BEFORE YOU BEGIN INST ALLA TION This unit is designed to be mounted on any standar d wiring junction box up to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Where to Install This Alarm” and “Where This Alarm Should Not Be Installed ” befor e you begin installation. If a junction box is not alr eady in place, install one using ...

  • First Alert SC9120B - page 4

    SPECIAL REQUIREMENTS FOR INTERCONNECTED ALARMS • Failur e to meet any of the above requir ements could damage the units and cause them to malfunction, removing your pr otection. • AC and AC/DC Smoke/CO Alarms can be interconnected. Under AC power , all units will alarm when one senses smoke or CO. When power is interrupted, only the AC/DC units ...

  • First Alert SC9120B - page 5

    The optional locking featur es ar e designed to discourage unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households wher e unauthorized battery or alarm r emoval is not a concern. These Smoke/CO Alarms have two separate locking features: one locks the battery compartment, and the other lock ...

  • First Alert SC9120B - page 6

    1. T est/Silence Button: Press and hold to activate test, or to silence the alarm. 2. POWER Light (GREEN)/ SMOKE ALARM Light (RED) 3. CO ALARM Light (RED) 4. Battery Drawer 5. (Behind the Cover) Alarm Horn: 85dB audible alarm for test, alarm, and unit malfunction war ning. 6 HOW YOUR SMOKE/CO ALARM WORKS THE COVER OF YOUR SMOKE/CO ALARM UNDERST AND ...

  • First Alert SC9120B - page 7

    7 WEEKL Y TESTING • NEVER use an open flame of any kind to test this unit. Y ou might accidentally damage or set fir e to the unit or to your home. The built-in test switch accurately tests the unit’ s operation as r equir ed by Underwriters Laboratories, Inc. (UL). NEVER use vehicle exhaust! Exhaust may cause per - manent damage and voids your ...

  • First Alert SC9120B - page 8

    8 POTENTIAL SOURCES OF CO IN THE HOME Fuel-burning appliances like: portable heater , gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insuf ficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger , blocked or clogged chimney opening. Improp ...

  • First Alert SC9120B - page 9

    REGULA TORY INFORMA TION FOR SMOKE ALARMS RECOMMENDED LOCA TIONS FOR SMOKE ALARMS Installing Smoke Alar ms in Single-Family Residences The National Fir e Pr otection Association (NFP A), recommends one Smoke Alarm on every floor , in every sleeping area, and in every bed- r oom. In new construction, the Smoke Alarms must be AC power ed and inter co ...

  • First Alert SC9120B - page 10

    GENERAL LIMIT A TIONS OF SMOKE/CO ALARMS This Smoke/CO Alarm is intended for residential use. It is not intended for use in industrial applications wher e Occupational Safety and Health Administration (OSHA) r equir ements for Carbon Monoxide Alarms must be met. The Smoke Alarm portion of this device is not intended to alert hearing impair ed r esi ...

  • First Alert SC9120B - page 11

    Printed in Mexico M08-0094-004 K1 10/07 BRK Electronics ® is a r egistered trademark of BRK Brands, Inc. First Alert ® is a r egistered trademark of the First Alert T rust. 11 LIMITED W ARRANTY BRK Brands, Inc., ("BRK") the maker of BRK ® brand and First Alert ® brand pr oducts, warrants that for a period of five years from the date o ...

Manufacturer First Alert Category Smoke Alarm

Documents that we receive from a manufacturer of a First Alert SC9120B can be divided into several groups. They are, among others:
- First Alert technical drawings
- SC9120B manuals
- First Alert product data sheets
- information booklets
- or energy labels First Alert SC9120B
All of them are important, but the most important information from the point of view of use of the device are in the user manual First Alert SC9120B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals First Alert SC9120B, service manual, brief instructions and user manuals First Alert SC9120B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product First Alert SC9120B.

A complete manual for the device First Alert SC9120B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use First Alert SC9120B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of First Alert SC9120B.

A complete First Alert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual First Alert SC9120B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the First Alert SC9120B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the First Alert SC9120B, that we can find in the current document
3. Tips how to use the basic functions of the device First Alert SC9120B - which should help us in our first steps of using First Alert SC9120B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with First Alert SC9120B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of First Alert SC9120B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning First Alert SC9120B?

Use the form below

If you did not solve your problem by using a manual First Alert SC9120B, ask a question using the form below. If a user had a similar problem with First Alert SC9120B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)