Manual Osburn HYBRID-45 MF

27 pages 1.31 mb
Download

Go to site of 27

Summary
  • Osburn HYBRID-45 MF - page 1

    PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufacture d by: Stove Builder International Inc. Quebec City (Quebec) CANADA 45165 • Warning: If your a ppliance is not properly installed a house fire ma y result. For your safety, follow the installatio n directions. Conta ct local buil ding or fir e officials about rest rictions and installa ti ...

  • Osburn HYBRID-45 MF - page 2

    Thank you for purchasing the HYBRID-45 MF pe llet stove. You are now prepared to burn wood in the most efficient, conv enient way possible. To achieve the safest, most efficient and most enjoyable performance from y our stove, you must do three th ings: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of th ...

  • Osburn HYBRID-45 MF - page 3

    • Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. • Keep foreign objects out of the hopper. • Never use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such liquids well away from ...

  • Osburn HYBRID-45 MF - page 4

    INTRODUCTION -------------------------------------------------------------------------------- ------------- 2 SAFETY PRECAUTIONS -------------------------------------------------------------------------------- -- 3 SPECIFICATIONS -------------------------------------------------------------------------------- ----------- 5 INSTALLATION ------------ ...

  • Osburn HYBRID-45 MF - page 5

    OSBURN HYBRID-45 MF FREESTANDING PELLET STOVE Width: 27” Height: 30 1/2” Depth: 24 5” Weight: 230 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 70 lbs. (This can vary widely depending on pellet size, length, and diameter) EPA status: exempt Burn rate: 1 lb. to 5.5 lbs. per hour BTU range: 8,200 to 45,000 Electrical consumption: 3.5 Amps ...

  • Osburn HYBRID-45 MF - page 6

    COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 3” ins ide diameter metallic pipe, either flexible or rigid, may be atta ched to the inlet at the stove’s rear (refer to figures 4, 5 & 6). A rodent guard (minim um ¼” wire mesh) must be used at the terminus (refer t ...

  • Osburn HYBRID-45 MF - page 7

    Equivalent Vent Length (EVL) The longer the run of pipe in your installation, the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equivalent Vent Length (EVL). • Horizontal runs shall not exceed 10 feet of EVL. • To calculate EVL, use the fo llowing conv ...

  • Osburn HYBRID-45 MF - page 8

    A. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9 & 10 for basement installation) NOTE: Follow L-Vent chimney manufacturer’s instructions. OPTION: To achieve a center vertical installation, a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove. OPTION: Install L-Vent elb ...

  • Osburn HYBRID-45 MF - page 9

    C. VERTICALLY INTO EXISTING M ASONRY FIREPLACE NOTE: Follow L-Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combus tion air is to be used, you wil ...

  • Osburn HYBRID-45 MF - page 10

    OPTIONAL LOG SET INSTALLATION To install the optional log set, you first need to rem ove the four screws indicated on figure 14a. Keep the screws. Locate t he two fixation brackets figure 14b that cam e with your owner’s manual. Fix the two brackets using the same scr ews y ou have removed. Lay the log set inside the firebox as shown on figure 14 ...

  • Osburn HYBRID-45 MF - page 11

    PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETI ZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not per mitted. It will violate the building c ...

  • Osburn HYBRID-45 MF - page 12

    a. MODE SWITCH • When the mode switch is pressed, the stove will automatically ignite. If the manual mode is selected, the heat level must be selected manually to adjust the stove’s heat output to the desired level. If the thermostat mode is selected, the stove will automatica lly modulate between the lowest heat level and the heat level select ...

  • Osburn HYBRID-45 MF - page 13

    IF THE STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blo wers will run unt il the stove cools down. This will take a few minutes. After the stove’s components stop running, an error message will appear . To restart, press the “RESET” button, refill the hopper , and press the “FUEL FEED” button until pellets begin to ...

  • Osburn HYBRID-45 MF - page 14

    OPERATING THE STOVE USING A THERMOSTAT A thermostat may help you maintain a constant house temperature automatically. A milli volt thermostat or 24 Volt thermostat is required. A fixed wall mount or hand held model can be used. The control panel can be set up two ways to operate your stove in thermostatic mode. THERMOSTAT INSTALLATION • Unplug th ...

  • Osburn HYBRID-45 MF - page 15

    OPERATING SAFETY PREC AUTIONS PLEASE READ THIS! a. If y ou notice a smoldering fire (burnpot full but no visible flam e) AND a he avy smoke buildup in firebox , immediately TURN OFF the stov e, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stov e. Wait until smoke inside the firebox clears ...

  • Osburn HYBRID-45 MF - page 16

    FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged. If so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal c ontainer with a tight-fitting lid. The closed container or as hes should ...

  • Osburn HYBRID-45 MF - page 17

    VACCUM USE If a vacuum is used to clean y our stove, we suggest using a vacuum designed for ashes. Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage. CLEANING a. Heat Exchange Tubes – Your Osburn Hybrid-45 MF stove is designed with a built-in hea ...

  • Osburn HYBRID-45 MF - page 18

    CHIMNEY CLEANING a. Creoso te Formation – When an y wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapo rs condense in the r ela tively cool chimney flue or a n ewly started fire or from a s low- burning fire. As a result, creosote residue accumulates on the flu ...

  • Osburn HYBRID-45 MF - page 19

    When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money b y enablin g you to solve simple problems yourself. Problems can be c aused by to only five factors: 1) poor fuel; 2) poor operat ion or maintenance; 3) po or installation; 4) component failure; 5) factory defect. You can us ually s ...

  • Osburn HYBRID-45 MF - page 20

    STOVE SHUTS OFF AND APPEA RS ON THE CO NTROL BOA RD Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is out of pellets. Refill the hopper. 2. The air damper is too far open f or a low feed setting. If burning on the low setting, you may need to close the damper all the way blowers have sleeve bearings that are pe ...

  • Osburn HYBRID-45 MF - page 21

    STOVE FEEDS PELLETS, BUT W ILL NOT IGNITE AND APPEARS ON THE CONTROL BOARD Possible Causes: Possible Remedies: 1. Air damper open too far for ignition. Turn the air supply knob toward the minimum setting for startup. In some situations, it may be necessary to have the damper completely closed for ignition to take place. After there is a flame, the ...

  • Osburn HYBRID-45 MF - page 22

    STOVE STOPS FEEDING PELLETS AND APPEARS ON THE CONTROL BO ARD Possible Causes: Possible Remedies: 1. The L-250 automatic high temperature switch has tripped. The L-250 automatic high temperature switch is located on the auger housing and will send a signal to the control board if the auger housing overheats. Wait until the stove cools down. YOU NEE ...

  • Osburn HYBRID-45 MF - page 23

    • GL AS S “ S O OT ’ S ” UP AT A V E R Y F AS T R AT E • FLAME IS LAZY, DARK, AND HAS BL ACK TIPS • AFTER STOVE HA S BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which restricts airflow through the burn pot. Follow all cleaning procedure in the maintenance section of the ...

  • Osburn HYBRID-45 MF - page 24

    ALARM CODES CHART MESSAGE CORRESPONDING ERROR Pressure switch error. L-250 automatic high temperature switch, located under the auger. L-250 manual reset high temperature s wit ch, located beside convection blower. Hopper is empty Lighting error. Hopper lid stay open more than 3 minutes. Inverted polarity in power outlet. Power outage Igniter fuse ...

  • Osburn HYBRID-45 MF - page 25

    L2(LINE COMMON) L1(LINE HOT) L1(LINE NO CONNECTED) FRAME GROUND L-250 RESET N.C. F-140 N.O. AIR FLOW PRESSURE SWITCH N.O. L-250 N.C. F-160 N.O. ELECTRONIC BOARD IGNITER AUGER MOTOR COMBUSTION/EXHAUS T BLOWER HOPPER LID SWITCH N.O. THERMOSTAT TERMINALS N.O. CONVECTION BLOWER CONVECTION BLOWER AIR SUPPLY KNOB HIGH TEMPERA TURE SWITCH F- 160 HIGH TEMP ...

  • Osburn HYBRID-45 MF - page 26

    Contact an Authorized OSBURN D ealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM PART # Airflow Pressure Switch 44029 Air Switch Hose 49004 Auger Motor 44038 Burn Pot PL52545 Control Board 44032 Combustion/Exhaust Blower Assembly 44039 Convection Blo ...

  • Osburn HYBRID-45 MF - page 27

    1700, rue Léon-Harmel, Québec (Québec) G 1N 4R9 tel. : (418) 527- 3060 fax : (418) 527-4311 e-mail : tech@sbi-international.com w eb site : www .osburn-mfg.com LIMITED LIFETIME WARRANTY The Osburn warranty extends only to the original consum er purchaser and is no t transferable. This warranty covers brand new pro ducts only, which have not been ...

Manufacturer Osburn Category Electric Heater

Documents that we receive from a manufacturer of a Osburn HYBRID-45 MF can be divided into several groups. They are, among others:
- Osburn technical drawings
- HYBRID-45 MF manuals
- Osburn product data sheets
- information booklets
- or energy labels Osburn HYBRID-45 MF
All of them are important, but the most important information from the point of view of use of the device are in the user manual Osburn HYBRID-45 MF.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Osburn HYBRID-45 MF, service manual, brief instructions and user manuals Osburn HYBRID-45 MF. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Osburn HYBRID-45 MF.

A complete manual for the device Osburn HYBRID-45 MF, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Osburn HYBRID-45 MF by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Osburn HYBRID-45 MF.

A complete Osburn manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Osburn HYBRID-45 MF - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Osburn HYBRID-45 MF, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Osburn HYBRID-45 MF, that we can find in the current document
3. Tips how to use the basic functions of the device Osburn HYBRID-45 MF - which should help us in our first steps of using Osburn HYBRID-45 MF
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Osburn HYBRID-45 MF
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Osburn HYBRID-45 MF in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Osburn HYBRID-45 MF?

Use the form below

If you did not solve your problem by using a manual Osburn HYBRID-45 MF, ask a question using the form below. If a user had a similar problem with Osburn HYBRID-45 MF it is likely that he will want to share the way to solve it.

Copy the text from the picture