Manual TANDBERG D13192

40 pages 0.73 mb
Download

Go to site of 40

Summary
  • TANDBERG D13192 - page 1

    Technical Description of TANDBER G Ga teway with software v ersion G2 TANDBER G D1319 2 Rev. 02 ...

  • TANDBERG D13192 - page 2

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 2 Table of contents 1 INTRODU CTION ......... .... ....... ....... ....... ....... ...... ....... ....... ....... ....... ...... ....... ....... ....... ....... .... ....... ....... ....... ...... 4 2 PRODUCT D ESCRIPTION ...... ....... ..... ...... ....... ...... ...

  • TANDBERG D13192 - page 3

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 3 4.5 .2 Teleph ony ...... ...... ....... ....... ..... ...... ....... ....... ....... ....... ....... ...... ....... ....... ....... ....... ...... ....... ....... ....... ....... .... 24 4.5 .3 Aud io Compressio n Algori thms ... ....... ..... ....... ...... ... ...

  • TANDBERG D13192 - page 4

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 4 1 Introduction The TANDBERG Gateway is designed to connect up to 8 videoconferencin g calls and 8 telepho ne calls simultaneously betwee n IS DN and I P Networks. The TANDBERG Gateway supports th e I TU-T H.32 0 standard and a combinatio n of H.22 1 and BONDI NG ...

  • TANDBERG D13192 - page 5

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 5 • Dual Stream - support s Duo Vide o TF on ISDN and IP, and People+Co ntent on ISDN. • Secure Access - Suppor ts XML /SOAP over H TTPS • Suppor t for TANDBERG S cheduler and TANDBERG Managem ent Suite - (Optional) • I SDN Hotl ine • Terminal Control Se ...

  • TANDBERG D13192 - page 6

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 6 4 TANDBERG Gatew ay Int erfaces & Fe atures Ext ensive use of industr y standard interfaces and connectors ensur e effortless integration o f extern al equipment with the TANDBERG Gateway . These interfaces can easily be contro lled via the web u ser interfa ...

  • TANDBERG D13192 - page 7

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 7 4.1.2 PR I E1/T1 ISDN 4.1.2.1 I SDN num ber plan The TANDBERG Gateway’s PRI lines may use one or m ore numbers for d ial in. If more than one n umber is u sed, the numbers m ust be conse cutive. 4.1.2.2 P RI Trunk Grou ping When using more than one PRI line, t ...

  • TANDBERG D13192 - page 8

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 8 Pinout of PRI E1/T1 I nterfac e: 4 NOTE: TANDBERG recommends always using category 5 cabling. PRI T1 (US onl y): Networ k Service Facility (NSF) can be c onfig ured as blan k/no value (i.e . NSF not used – default) o r any value between 0 and 31 , to describe ...

  • TANDBERG D13192 - page 9

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 9 4.1.3 Dial In Services 4.1.3.1 Direct Inwards Dialing (DID) By enabling this feature, it is possible to mak e a dire ct mapping between ISDN numbers and H323 aliases. T his requires that the PRI lines connected to the TANDBERG Gateway are configured with a range ...

  • TANDBERG D13192 - page 10

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 10 4.1.3.4 Ho tline When calling the Hotl ine number spe cified in the TAN DBE RG Gateway, the call is automatically transferred to a predefin ed H.323 alias. This feature can be used w hen an operator or helpdesk is needed. All ISDN Dial In features (DID, IVR, TC ...

  • TANDBERG D13192 - page 11

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 11 which packets to send first and which to throw away. Some information/traffic is time critical while ot her is not, and classification is used to differentiate this traffic. One may set separate I P precede nce fo r Signalling, Audio, Video a nd Data (va lues 1 ...

  • TANDBERG D13192 - page 12

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 12 An example of this is automa tic adjustment of tota l bandwidth used when DuoVide o i s opened. 4.1.5.3 Dynamic playou t buff ering Shapes the inc oming da ta for be tter play out and re-se quenc ing of pa cket de livere d out of order. This ensures better li p ...

  • TANDBERG D13192 - page 13

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 13 4.1.5.7 Laye r 4 Ports used in H.323 The following tables describe s which lay er 4 ports are being used by the TANDBERG Gateway when a call is made on an H.323 network. TANDBERG Gateway meetings + Duo Video Function Port Type Gatekeeper Discovery (RAS) 1719 UD ...

  • TANDBERG D13192 - page 14

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 14 4.1.5.9 In telligent Packet L oss Recovery (IPLR) I PLR is an ITU standards based pack et loss compensation fo r H.323 that i mproves received video into the TAN DBERG Gatew ay . IPL R suppo rts all video protoc ols and resolution s that TANDBERG Gateway alread ...

  • TANDBERG D13192 - page 15

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 15 4.1.6 LEDs Description The TANDBERG Gateway has 24 LEDs (L ight Em itting Diodes) on the front p anel. Each giving various in formation, a s shown be low. 4.1.6.1 D escript ion of PRI Alarms A PRI cable consists of four wires (2 pairs of wires): One pair for Tr ...

  • TANDBERG D13192 - page 16

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 16 Scenario: TANDBERG Gateway is connected v ia a CSU (i.e. a NT ‘Network Termination’) as follows : TANDBER G Gateway –cableA–CSU–cab leB–Network I f a CS U loses framing/sync from the net work (exampl e: a bad cable B), i t shall no l onger send vali ...

  • TANDBERG D13192 - page 17

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 17 4.1.8 TANDBERG G ateway Capacity The tot al capacity of the TANDBERG Gateway is defin ed by the followi ng rules. I. Maxi mum 8 video c alls and 8 teleph ones calls. II. T otal system bandwidth (IP + ISDN) of the TANDBERG Gateway i s 7680 k bps. The maximum ban ...

  • TANDBERG D13192 - page 18

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 18 4.1.8.1 TAND BERG Gateway Capa ci ty – typica l scenarios for 4Mb Option I n t he table below some typical capacity scenarios are li sted (they can be derived by the calculation abo ve): Band width Non -e ncry pted (Max. no . of vi deo calls + telephone calls ...

  • TANDBERG D13192 - page 19

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 19 which encry pts "the session key s". Wh en the session are coll ected by th e remote end, en cry ption of the audio, video and data channels c an start. The encry pt ion will be established automatically when both endpoints in the conference supports ...

  • TANDBERG D13192 - page 20

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 20 4.2 Aggregation Stan dards ISD N Aggregation H.221 Frame Structu re from 64 (56 * ) k bps to 12 8 kbps ISO 13871 BOND ING , Mode 1 from 64 (56 * ) kbps t o 2 Mbps H0 O ne 38 4 kbps channel 4.2.1 BONDING • I SO 13871, B O NDI NG Mode 1 for bit rate s from 56 k ...

  • TANDBERG D13192 - page 21

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 21 4.3 RS232 Interface/Application Progra m m able Interface (API) Data Sta ndards Data TANDBERG Dynamic Da ta Channel (DDC) Modem Standard modem comm ands Data I nterfaces 1 x Data port, R S-232 (9-pin D-s ub), Up t o 115200 Baud for Dat a & Co ntrol The RS2 ...

  • TANDBERG D13192 - page 22

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 22 4.4 Video Features The TANDBERG Gateway supports the ITU video standards H.26 1, H.263, H .263+ and H .264. 4.4.1 Optim ised Video Com pression The I TU standard H.264 provides: • Optimised comp ression and decompr ession of video at lower ban dwidths. • A ...

  • TANDBERG D13192 - page 23

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 23 4.4.4 Duo Video The TANDBERG Gateway is capable of receiving/transmitting two si multaneous video signals from/t o the connected sites 7 on all call rates fr om 128kbps and a bove. When one of the sites requests for Du o Video, th e TANDBERG Gateway will open D ...

  • TANDBERG D13192 - page 24

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 24 4.5 Audio Fe atures 4.5.1 Custom Sounds The TANDBERG Gateway has a variety of sounds that may b e changed by storing new f iles on the FTP fil e sy stem of the TA NDBERG Gateway. Ref. C h.5.2 for details. 4.5.1.1. 1 Gateway Welcome When en dpoints are enterin g ...

  • TANDBERG D13192 - page 25

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 25 4.6 System Manage m ent TANDBERG provi des a comprehensive set o f management too ls, and is committ ed to the use o f standard s-based tools. The TANDBERG Gateway can be managed in many way s :  The int ernal web server al lows for remo te control of the TA ...

  • TANDBERG D13192 - page 26

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 26 operating sy stems), wh ich includes t he necessary pro grams such as: • An FTP clien t (please see ‘Upgrading so ftware in TANDBERG Videoconferencing units’- doc ument D102 38 - for deta ils) • A web-browser (please see ‘TANDBERG Gateway User Manual? ...

  • TANDBERG D13192 - page 27

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 27 remotely . Loc al mana geme nt, control and sof tware upgra de facilities are also availa ble throug h a standard RS232 interface. 4.6.4 System Managem ent F u nctionality 4.6.4.1 R emote software up grades using F TP: This serv ice is provided by the standar d ...

  • TANDBERG D13192 - page 28

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 28 • SSL Secure Sockets L ay er, protocol develop ed by Netscape for transmitting private documents via the Internet. SSL works by using a private key to encrypt data that is transfe rred ove r the SSL conne ction. • HTTPS - Web pag es that require an SSL conn ...

  • TANDBERG D13192 - page 29

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 29 I t is also important to understand that only the password is protected with this service. The actual connectio n is not en cry pted, and can be sniffed as for a normal teln et connection. 4.6.5.3 D isable Ser vices There is n o router in side the sy stem that ...

  • TANDBERG D13192 - page 30

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 30 4.6.6 Layer 4 ports u sed by the system The fol lowing TC P and UDP p orts are relevan t for the TANDBERG Gateway. Function Por t Type Direction Gatekeep er RAS 1719 UDP ⇔ Gatekee per Discove ry 224.0.1. 41:1718 UDP ⇔ Q.931 Call Setup 1720 TCP* ⇔ H.245/Q. ...

  • TANDBERG D13192 - page 31

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 31 5 Miscellaneous features 5.1 Ph one bo ok The TANDBERG Gateway can store up to 1 00 numbers in the phonebook . The phonebook may be edited th rough the web in terface or by editin g the dir.prm file, stored on file sy stem of the TANDBERG Gateway (FTP). It also ...

  • TANDBERG D13192 - page 32

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 32 Directory - dir.prm This file contains the d irectory /phonebook o f the TANDBERG G ateway . ...

  • TANDBERG D13192 - page 33

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 33 6 En vir onme nta l Issue s 6.1 TANDBERG ’s Envi ronme ntal Policy • TANDBERG’s Research and Development i s conti nuously impro ving TANDBERG’s products to wards le ss use of environ mentally hazardous com ponents and substanc es as well as to m ake th ...

  • TANDBERG D13192 - page 34

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 34 7 Product Approvals The prod uct has been appro ved by va rious i nternational ap proval agencies, am ong others: UL, BABT and NEMKO. Accord ing to their Follo w-Up Inspection Scheme, these agencies also perform productio n inspections at a regular basis, for a ...

  • TANDBERG D13192 - page 35

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 35 7.6 NEBS approval This produc t com plies with the standar ds GR-63 -CORE and GR-1 089-CORE an d is NEBS approved by U L . For NEBS compliance, the product should be installed in the following manner : - Use the enclosed rack brackets marked "NEBS". - ...

  • TANDBERG D13192 - page 36

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 36 8 Product Reliability The predicted reliab ility of the TANDBER G Gateway is expressed in th e expected rand om Mean Time Be t we en Failures ( MTBF) for the elec t ronic components base d on the P ow er On Hours (P OH). • The POH fo r the TANDBER G Gateway i ...

  • TANDBERG D13192 - page 37

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 37 9 Technical specification of TANDBERG Gateway 9.1 Mech anical inform ation 10 TANDBERG Gatew ay Height 4.4 cm 1.7 in Width 44.2 cm 17.4 i n Depth 31.8 cm 12.5 in Weight 5 .15 kg 11.3 lbs The TANDBERG Gateway is a standard 19 inch rack mount able with 1U h eight ...

  • TANDBERG D13192 - page 38

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 38 9.3 Operating Temperature and Hum i dity • 0 ° C to 35 ° C (32 ° F t o 95 ° F) ambient temperatu re. • 10% to 90 % Relative Humidity (RH) 9.4 Storage and Transpo rt Tem p erature • -20 ° C to 60 ° C (-4 ° F to 140 ° F) at RH 10-90 % (non- conde ns ...

  • TANDBERG D13192 - page 39

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 39 10 Technical Sp e cification sh eet System Capacity Maximu m n umber of video conferencin g calls: 8 Maxim um nu mber of audio cal ls: 8 Endpoints Supported H.320 con fer encin g en dpoin ts H.323 con fer encin g en dpoin ts Analogue / IP telep hones Bandw idth ...

  • TANDBERG D13192 - page 40

    Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 Rev . 02 40 System Ma nagem ent To tal management via e mbedde d WE B ser ver using HTTP S , S NM P, Tel ne t a nd FTP 1 x RS- 232 for local s oftw are upg rades , local cont rol and d iagnos tics Management usi ng TANDB ERG Ma nagement Suite Call sc heduling via TANDB ERG ...

Manufacturer TANDBERG Category Network Router

Documents that we receive from a manufacturer of a TANDBERG D13192 can be divided into several groups. They are, among others:
- TANDBERG technical drawings
- D13192 manuals
- TANDBERG product data sheets
- information booklets
- or energy labels TANDBERG D13192
All of them are important, but the most important information from the point of view of use of the device are in the user manual TANDBERG D13192.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals TANDBERG D13192, service manual, brief instructions and user manuals TANDBERG D13192. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product TANDBERG D13192.

A complete manual for the device TANDBERG D13192, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use TANDBERG D13192 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of TANDBERG D13192.

A complete TANDBERG manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual TANDBERG D13192 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the TANDBERG D13192, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the TANDBERG D13192, that we can find in the current document
3. Tips how to use the basic functions of the device TANDBERG D13192 - which should help us in our first steps of using TANDBERG D13192
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with TANDBERG D13192
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of TANDBERG D13192 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning TANDBERG D13192?

Use the form below

If you did not solve your problem by using a manual TANDBERG D13192, ask a question using the form below. If a user had a similar problem with TANDBERG D13192 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)