Documents that we receive from a manufacturer of a Furuno CSH-5 MARK-2 can be divided into several groups. They are, among others:
- Furuno technical drawings
- CSH-5 MARK-2 manuals
- Furuno product data sheets
- information booklets
- or energy labels Furuno CSH-5 MARK-2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Furuno CSH-5 MARK-2.
- UserManuals.org
- Furuno
- Furuno SONAR
- Furuno CSH-5 MARK-2
Manual Furuno CSH-5 MARK-2
Go to site of 73
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
Summary
-
Furuno CSH-5 MARK-2 - page 1
COLOR SCANNING SONAR CSH-5 MARK-2 ...
-
Furuno CSH-5 MARK-2 - page 2
C 9-52 , Ashi har a-ch o, Ni shinom i ya, Ja pa n T e lephone: 0798- 65 -21 1 1 T e lefax: 0798-65-4200 Y o ur Loc al Ag en t/ Deal er All rights re ser v ed. PUB . No . OM E-12990 CSH-5 MA RK2 ( DAMI ) FIRS T EDITION : NOV . 1995 E : DEC. 6, 2000 Prin ted i n J ap an ...
-
Furuno CSH-5 MARK-2 - page 3
i i i i i i i i i i i i i i SAFETY INSTRUCTIONS WARNING WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment. Continued use of the equipment can cause fire or e ...
-
Furuno CSH-5 MARK-2 - page 4
ii CAUTION CAUTION Do not exceed 18 knots when operating the equipment and do not exceed 16 knots when lowering or raising the transducer. The transducer may become damaged. The zinc block attached near the transducer must be replaced yearly. The junction between the transducer and main shaft may corrode, which can result in loss of the transducer ...
-
Furuno CSH-5 MARK-2 - page 5
iii T ABLE OF CONTENTS 1. FOREWORD _________________________________________ 1 2. SYSTEM CONFIGURA TION _____________________________ 2 3. CONTROLS _________________________________________ 3 Operating Controls .......................................................................................................... 3 Main Panel ................... ...
-
Furuno CSH-5 MARK-2 - page 6
iv 9. W ARNING __________________________________________ 30 Overvoltage W arning ..................................................................................................... 30 Unretracted T ransducer W arning ................................................................................... 30 10. MENU __________________________________ ...
-
Furuno CSH-5 MARK-2 - page 7
1 1. FOREWORD The FURUNO CSH-5 MARK-2 Color Scanning Sonar is a full- circle, multibeam electronic scanning sonar which detects and instan- taneously displays fish schools and underwater conditions in 16 colors on a 14" non-glare, high resolution CR T screen. Its ease of operation, versatility and compact size make it the perfect match for any ...
-
Furuno CSH-5 MARK-2 - page 8
2 2. SYSTEM CONFIGURA TION System Configuration ...
-
Furuno CSH-5 MARK-2 - page 9
3 3. CONTROLS Operating Controls The CSH-5 MARK-2 provides intuitive operation. If you change a control setting you will see the associated reaction on the screen al- most immediately . All operations are carried out from the main panel and the control box. The front panel incorporates mainly controls which do not require frequent adjustment, such ...
-
Furuno CSH-5 MARK-2 - page 10
4 Main Panel 4 6 8 2 0 10 4 6 8 2 0 10 4 6 8 2 0 10 4 6 8 2 0 10 4 6 8 2 0 10 4 6 8 2 0 10 NOISE LIM AGC 2 1 3 OFF VP 2 1 3 OFF IR CONTRAST BRILL DIMMER AUDIO POWER ON OFF AGC suppresses the echo tail of strong targets, e.g., the seabed, for easy recognition of fish schools adjacent to the sea bottom. Position "1" or "2" is the ...
-
Furuno CSH-5 MARK-2 - page 11
5 Control Box Panel GAIN RANGE TRANSDUCER AUTO TIL T SECTOR SCAN F1 EVENT R/B OFF- CENTER F2 EVENT DELETE MENU TX TIL T -+ -+ TRANSDUCER retracts and lower the transducer . The lamp above the switch flickers while the transducer is moving and lights when stopped. TX turns on the transmitter , freeze the display and turns of f the transmitter . The ...
-
Furuno CSH-5 MARK-2 - page 12
6 EVENT displays the latest event mark “ + ” and its position data; i.e., horizontal range, depth and bearing measured from own ship’ s posi- tion. (optional interface board is required to use this function.) T o delete event mark, locate the cursor on a event mark you want to delete and press EVENT DELETE key . R/B draws a straight line, cal ...
-
Furuno CSH-5 MARK-2 - page 13
7 Menu Screen The CSH-5 MARK-2 employs four menu screens; menu-l, menu-2 and system menu. Of the four menus, the menu-2 and system menu contain preset items which do not require setting alteration if they are once set at installation. See page 32 for further details. The menu-l contains items to be set by the operator while using the sonar, taking ...
-
Furuno CSH-5 MARK-2 - page 14
8 T urning Off Scan Menu T o turn of f the scan menu, press the MENU key . Note: Settings for the items shown in r ed ar e locked. T o unlock the settings, call up the system menu. See page 33. List of Scan Menu Items HUE : 1 234 TX OUTPUT :8 PLUSELENGTH : 7 TX CYCLE : 10 TVG NEAR : 6 TVG F AR : 7 AUTO SCN WDTH : ± 10 ° ± 20 ° ± 40 °± 60 ° ...
-
Furuno CSH-5 MARK-2 - page 15
9 N A C S O T U A H T D I W ; h t d i w n a c s e h t s t e S ± , 0 1 ± , 0 2 ± r o 0 4 ± e d i w a e s U . ) s e e r g e d n i ( 0 6 e c n o t i g n i w o r r a n , a e r a n a c s a f o h c r a e s l a r e n e g a t c u d n o c o t h t d i w . d e t c e t e d s i l o o h c s h s i f a H T D I W T L I T O T U A ; ) s e e r g e d n i ( h t d i ...
-
Furuno CSH-5 MARK-2 - page 16
10 4. BASIC OPERA TION General This section provides information necessary for basic operation of the CSH-5 MARK-2, from turning the power on and off to detecting and tracking fish schools. The basic operating procedure is shown below . Basic Operating Procedure 2 / 7 Lower/raise transducer . Location for magnetic function card 4 T urn transmitter ...
-
Furuno CSH-5 MARK-2 - page 17
11 Power Off Press the TRANSDUCER “ ” switch on the control box. W ait until the lamp above the switch lights, and then press the POWER “ OFF ” switch. Note that the transducer automatically retracts into the tank even if the POWER “ OFF ” switch is pressed without raising the transducer (by pressing the TRANSDUCER “ ” switch). Howe ...
-
Furuno CSH-5 MARK-2 - page 18
12 Seabed Echo vs Tilt Angle Case 1: T ilt Angle 30 to 40 degrees A wide tilt angle will display the entire seabed since it is captured by the full width of the beam. Case 2: T ilt Angle 10 to 20 degrees A narrow tilt angle will display only half the seabed since it is cap- tured by only the lower half of the beam. Case 3: T ilt Angle 0 to 10 degre ...
-
Furuno CSH-5 MARK-2 - page 19
13 Points to Consider • As a general rule of thumb, a vertically distributed fish school is a better sonar tar get than the seabed, since it reflects the transmitted pulse back toward to the source. • In case 3, both fish schools a and b are presented. Generally speaking, however , midwater fish schools tend to be larger than bottom fish school ...
-
Furuno CSH-5 MARK-2 - page 20
14 TIL T ANGLE T ilt angle vs. Beam Coverage 20 (40) 40 (80) 60 (120) 80 (160) 100 (200) 200 (400) Depth m 100 (200) 200 (400) 300 (600) 400 (800) Range m 0 ° 5 ° 10 ° 15 ° 13 ° 23m 100m 46m 200m 68m 300m V ertical Width of Sonar Beam ...
-
Furuno CSH-5 MARK-2 - page 21
15 Adjusting the Gain The gain should be adjusted to see fish echoes clearly with minimal noise on the screen. T oo high a setting not only causes excessive noise on the screen and makes it difficult to discriminate wanted fish echoes but also causes seabed echoes to be painted in strong colors, resulting that the echoes from bottom fish are masked ...
-
Furuno CSH-5 MARK-2 - page 22
16 5. FINE TUNING THE PICTURE General In the previous chapter basic operation of the sonar was presented. This chapter describes the procedures for fine tuning the sonar pic- ture. Eliminating Unwanted Feeble Echoes Echoes from tar gets such as seabed and fish return to the transducer in order of distance to them, and when we compare their intensit ...
-
Furuno CSH-5 MARK-2 - page 23
17 3. Locate a fish school on a long range setting which is approaching own ship. Note that the tilt should be kept adjusted so that the fish school is always placed in the center of the sonar beam, i.e., so that the fish school is displayed in strongest colors possible. Check that the fish echo is displayed in the same color while it approaches. I ...
-
Furuno CSH-5 MARK-2 - page 24
18 Suppressing Seabed and Sea Surface Reflections in Shallow Fishing Grounds In shallow fishing grounds with hard or rocky bottom, seabed reflec- tions often interfere with wanted fish echoes and they can not be eliminated sufficiently with the aforementioned TVG and AGC con- trols, especially when the TIL T is set to a larger angle in order to tra ...
-
Furuno CSH-5 MARK-2 - page 25
19 Rejecting Noise with IR Control This control is similar to the interference rejector on echo sounders and radars. It is effective for rejecting random noise and sea surface reflections in rough sea conditions. Set the IR control to positions “1” thru “3” so that noise is just eliminated. Do not use an unneces- sarily high setting since i ...
-
Furuno CSH-5 MARK-2 - page 26
20 6. ADV ANCED OPERA TION General It this section, how to use the CSH-5 MARK-2 effectively in actual fishing operations is presented. Measuring Range and Bearing to a T arget T o measure the range and bearing to a target, use the trackball. Procedure 1. Operate the trackball to place the trackball mark “ ” on the tar - get you want to measure ...
-
Furuno CSH-5 MARK-2 - page 27
21 Procedure 1. Move the trackball mark “ ” to the direction you want to moni- tor through the speaker , by operating the trackball. 2. Press the R/B key . The bearing marker will appear in the direction of the trackball mark and echoes in that direction are monitored through the speaker . Adjust the volume with the AUDIO control on the front p ...
-
Furuno CSH-5 MARK-2 - page 28
22 2. Press the OFF-CENTER key on the front panel. 3. T o move the own ship mark back to the center of the screen, press the OFF-CENTER key again. Finding Fish School Center When you want to find the center depth of a fish school, use the auto tilt function which automatically scans the tilt angle within the se- lected width. Procedure 1. Call up t ...
-
Furuno CSH-5 MARK-2 - page 29
23 Registering Procedure 1. Press the MENU key . 2. Rotate the RANGE control to select FUNC KEY PROG. 3. Rotate the GAIN control to select FUNC1 or FUNC2. 4. Press the TX key . Each time the TX key is pressed, the current settings in the scan menu and E/S menu are recorded. When F ACTOR Y is selected, the default value is displayed. Recalling Proce ...
-
Furuno CSH-5 MARK-2 - page 30
24 7. MARK AND DA T A This chapter describes the marks and data which appear on the dis- play screen. TRACKBALL MARK DA T A Slant Range Horizontal Range Depth T rue Bearing TRACKBALL MARK HEADING MARK OWN SHIP MARK RANGE TIL T AUTO TIL T GAIN BEARING MARK RANGE MARK RANGE RING BEARING OF BEARING MARK RANGE T O RANGE MARK G . Marks k r a M p i h S n ...
-
Furuno CSH-5 MARK-2 - page 31
25 g n i R e g n a R n i e g n a r e h t f o 4 / 1 f o s l a v r e t n i t a d e t t o l p e r a s g n i r e g n a r e h T . s g n i r e g n a r o w t y r e v e d e d i v o r p o s l a e r a a t a d g n i r e g n a R . e s u e h t f o 2 / 1 o t 4 / 1 m o r f d e r e t l a e b n a c l a v r e t n i g n i r e g n a r e h T n a c s n o g n i t t e s e ...
-
Furuno CSH-5 MARK-2 - page 32
26 8. INTERPRETING THE DISPLA Y General This section provides information necessary for interpreting the display . Interpreting the Display Seabed When the tilt angle is changed, the seabed echo illustrated below will appear on the screen. When the tilt angle is decreased, the seabed trace becomes wider and weaker . By observing the seabed conditio ...
-
Furuno CSH-5 MARK-2 - page 33
27 Fish School A fish school appears as a mass of echoes on the screen. The color of the mass shows the density of fish schools on the sonar beam. T o know the distribution and center point of a fish school, the tilt should be changed to several different angles. Sea Surface Reflections Fish school (a) Sea Surface Fish T ilt Angle: +5 ° - 10 ° Be ...
-
Furuno CSH-5 MARK-2 - page 34
28 Sea Surface Reflections T o reduce the sea surface reflections, set the tilt angle to 5 ° or more so that the upper edge of the sonar beam may not hit sea surface, or adjust TVG functions. When the sonar is used with a narrow tilt angle, the sea surface reflections cover lar ge area (up to 300 m to 400 m) as illustrated below . SEA SURF ACE T i ...
-
Furuno CSH-5 MARK-2 - page 35
29 False Echo by Sidelobe In the preceding chapters, it was explained that an ultrasonic wave is emitted only in the direction set by the TIL T lever , but, in practice, there are some emissions outside the main beam that are called “sidelobes”. Energy of the sidelobe is fairly weak but when the sonar is used in comparatively shallow water with ...
-
Furuno CSH-5 MARK-2 - page 36
30 9. W ARNING Overvoltage W arning If the supply voltage rises about 20% to over the rated value, the overvoltage detection circuit is actuated. The following warning flick- ers at the center of the screen and an alarm sounds. OVER VOL T AGE! If this occurs, retract the transducer, turn the POWER off and check the ship’ s mains (and the stepdown ...
-
Furuno CSH-5 MARK-2 - page 37
31 Hand Crank hull unit Bottom Down Command LED (Red) Power LED (Green) Power SW Breaker ON OFF Main Fuse Fuse for T ransceiver T ransceiver Unit Power switch (Normally " " position) ...
-
Furuno CSH-5 MARK-2 - page 38
32 10. MENU General The CSH-5 MARK-2 employs three menu screens, menu-1 menu-2, and system menu, to preset infrequently used functions. Changing Menu Settings Procedure to Change Menu Settings 1. T urn off the transmitter with the TX key; LED flickers. 2. Press the MENU key . The menu-1 appears. 3. T o select another menu, operate the GAIN control. ...
-
Furuno CSH-5 MARK-2 - page 39
33 Menu-2 The figure below shows menu-2. ** MENU 2 ** EXT KP OFF ON RANGE MARKER 1/4R 1/2R OFF MARK INDI ± 180 ° 360 ° MENU MODE : MENU-1 MENU-2 SYSTEM U N E MG N I N A E M E D O M U N E M. u n e m m e t s y s . 2 - u n e m . l - u n e m : u n e m a s t c e l e S g n i y e K l a n r e T X E e s l u P , y l s u o e n a t l u m i s d e t a r e p o ...
-
Furuno CSH-5 MARK-2 - page 40
34 M E T I U N E MG N I N A E M E D O M U N E M. u n e m m e t s y s , 2 - u n e m , 1 - u n e m ; u n e m a s t c e l e S J D A G N I D A E H h c i h w , t n e m n g i l a s i m t i n u l l u h r o f e t a s n e p m o c o t d e s u s i u n e m s i h T N I A G e h t g n i t a r e p o y b g n i d a e h l a u t c a e h t t e S . r o r r e g n i d a e ...
-
Furuno CSH-5 MARK-2 - page 41
35 1 1. INTERF ACE MODULE CSH-5060 Specifications The CSH-5060 Interface Module permits connection of external equip- ment (navigational equipment, current indicator, echo sounder , net sonde, gyrocompass, log, etc.) to display various data on the CSH-5 MARK-2. 1. Display Mode (a) Normal (b) Normal + T ext (c) Echo Sounder Combination (Normal + Ech ...
-
Furuno CSH-5 MARK-2 - page 42
36 Operation The functions of the Interface Module are accessed from the MENU screen except the Event mark and North mark*. * —Gyrocompass required. 1. Event Mark and Own Ship Mark Plotting (1) Move the cursor to the location where you want to plot the event mark. (2) Press the EVENT key . The cursor is replaced with the latest event mark [ ] and ...
-
Furuno CSH-5 MARK-2 - page 43
37 T ARGET LOCK FUNCTION θ 1 θ 2 D The target lock function allows continuous tracking at a present depth "D". That is, the tilt angle changes automatically from " θ 1" to " θ 2" as the ship approaches the fish. 3. Erasing Weak Noise Unknown weak noise appearing over the entire screen can be erased with DELETE COLO ...
-
Furuno CSH-5 MARK-2 - page 44
38 4. Suppressing Effects of Pitching and Rolling The Motion Sensor MS-100 (option) compensates for the ef fects of pitching and rolling to provide stable sonar pictures. Y ou may enable it as follows: 1. Press the [MENU] key to display the SCAN menu. 2. Use the RANGE control to select RANGE/BEARING. 3. Use the GAIN control to select ST AB. 4. Pres ...
-
Furuno CSH-5 MARK-2 - page 45
39 5. Detecting Fish Echoes in Specific Area (Fish Alarm) The fish alarm alerts you to fish echoes in an area you select. Any fish echoes entering the area will trigger the audio alarm. The fish echo level which triggers the alarm may be selected from the scan menu. 1. Press the [MENU] key to open the SCAN menu. 2. On the scan menu, use the RANGE c ...
-
Furuno CSH-5 MARK-2 - page 46
40 6. Fish Alarm On/Off, Fish Alarm Sensitivity The audio alarm for the fish alarm can be enabled/disabled and the fish alarm sensitivity can be selected from the scan menu. 1. Press the [MENU] key to open the SCAN menu. 2. Use the RANGE control to select FISH ALARM. 3. Use the GAIN control to select the echo strength which will trig- ger the fish ...
-
Furuno CSH-5 MARK-2 - page 47
41 8. Menu Description The CSH-5 MARK-2 employs three menu screens, MENU-1, MENU- 2 and SYSTEM Menu, to preset infrequently used functions. During normal operation (transducer lowered, transmitter ON), the SCAN Menu appears on the screen. This lets you adjust settings while ob- serving the sonar picture. n o i t a c i l p p Ae s u o t w o H 1 - U N ...
-
Furuno CSH-5 MARK-2 - page 48
42 MENU-2 ** MENU-2 ** ( RANGE SW : U/D GAIN SW : L/R ) EXT KP SYNC : OFF ON RANGE MARKER : 1/4R 1/2R OFF BEARING SCALE : ON OFF CURRENT MARK : ON OFF COURSE MARK : 10R 5R OFF HEADING INDI : 32-AZI TRUE CURRENT INDI : 32-AZI TRUE ± 180 ° 360 ° EVENT INDI : 32-AZI TRUE ± 180 ° 360 ° MARK INDI : ± 180 ° 360 ° POSITION DA T A : L/L TD [MENU M ...
-
Furuno CSH-5 MARK-2 - page 49
43 SCAN MENU ** SCAN MENU ** ( RANGE SW : U/D GAIN SW : L/R ) MENU MODE : SCAN E/S DISPLA Y MODE : COMBI-1 NORM TEXT COMBI-2 HUE : 1 2 3 4 TX OUTPUT :8 PULSELENGTH : 7 TX CYCLE : 10 TVG NEAR : 6 TVG F AR : 7 DELETE COLOR : 0 AUTO SCN WDTH : ± 10 ° ± 20 ° ± 40 °± 60 ° AUTO TL T WDTH : ± 2~10 °± 4~14 ° ± 6~20 ° ± 10~26 ° MARK ERASE : ...
-
Furuno CSH-5 MARK-2 - page 50
44 10. Contents of Menu Items This section describes the menu items available with the addition of the CSH-5060 and external equipment. MENU-1 (SCAN, E/S Menu) Scan menu Item MENU MODE DISPLA Y MODE Contents Selects a menu; MENU-1, MENU-2 or SYSTEM Menu. Selects a picture display mode among the four below . NORM: Normal Mode; displays a sonar pictu ...
-
Furuno CSH-5 MARK-2 - page 51
45 E/S Menu Item E/S SHIFT E/S IR E/S GAIN E/S CLUTTER E/S ADV ANCE E/S COL CUR VE (Response Color Curve) E/S DRAFT Contents Shifts the start depth of the display range and the maximum value is about 1000 m irrespective of the depth unit. The unit shift value is determined by the range in use. See table below . T urns the Interference Rejector on a ...
-
Furuno CSH-5 MARK-2 - page 52
46 MENU-2 (Refer to pages 47 to 51 for location on the scr een.) m e t Is t n e t n o C E L A C S G N I R A E B. f f o d n a n o e l a c s g n i r a e b c i n o r t c e l e e h t s n r u t u n e m s i h T K R A M T N E R R U C. f f o d n a n o k r a m t n e r r u c e h t s n r u t u n e m s i h T K R A M E S R U O C : R ( R 5 r o R 0 1 m o r f t o ...
-
Furuno CSH-5 MARK-2 - page 53
47 Indications 1. Normal Mode (NORM) 4 2 5 1 6 6 3 1 2 3 Electronic Bearing Scale Mark Indication (Bearing) Course Mark 4 5 6 Heading Indication Current Mark Own Ship ’ s Mark ...
-
Furuno CSH-5 MARK-2 - page 54
48 2. Normal + T ext Mode 9 !1 !0 7 8 7 8 9 Current Indication Position Data Latest Event Mark Data !0 !1 Past Event Mark Navigational Data ...
-
Furuno CSH-5 MARK-2 - page 55
49 3. Echo Sounder Combination Mode (COMBI 1) Normal + Echo Sounder 16 Color Bar Sonar Picture Echo Sounder Picture ...
-
Furuno CSH-5 MARK-2 - page 56
50 4. Sonar Combination (COMBI 2) Normal + Signal on R/B Mark 16 Color Bar Sonar Picture Signal on R/B Mark ...
-
Furuno CSH-5 MARK-2 - page 57
51 Marks and Data This section explains the Marks and Data available from the equip- ment interfaced. Pages 24 to 25 show the location of these Marks and Data. The position data of the latest event mark, i.e., horizontal range ( → ), present depth ( ↓ ) and bearing. ( ) shows the latest event mark original depth which remains unchanged even if ...
-
Furuno CSH-5 MARK-2 - page 58
52 Event Mark Position Output Connected to a navigator, the CSH-5 MARK-2 can output event mark position data to external equipment when the [EVENT] key is oper - ated. The data sentence output is "SSTLL" (NMEA, IEC-1 162 for - mat). ...
-
Furuno CSH-5 MARK-2 - page 59
53 12. MAINTENANCE General The CSH-5 MARK-2 is designed and constructed to provide many years of trouble-free performance when properly maintained. User - performable maintenance and important points to be observed are outlined in the figure below . Reapply one coat of antifaulant "MARINE ST AR 20 Mod (Red-N)" (no other paints are allowed ...
-
Furuno CSH-5 MARK-2 - page 60
54 13. UNIT DIAGNOSTIC TESTS This unit has eight built-in diagnostic tests which check it for proper performance. Although the tests are designed primarily for use by the service technician, they can also be executed by the user to identify defective components. However , never attempt to check inside the unit; there are no user-serviceable parts i ...
-
Furuno CSH-5 MARK-2 - page 61
55 Conti T est This is a continuous test of the Display and T ransceiver Units. Addi- tionally checked devices are DROM and DRAM. CONTI TEST MAIN 105-0541-XXX 105-0542-XXX ROM = OK RAM = OK P. W = O K DROM = OK DRAM = OK DPRAM = OK TRX 105- ∗∗∗∗ -XXX 105- ∗∗∗∗ -XXX ROM = OK RAM = OK DROM = OK I/F 105-0267-XXX ROM = OK RAM = OK DPRAM ...
-
Furuno CSH-5 MARK-2 - page 62
56 Color T est The color test checks for proper display of all colors. COLOR TEST PRESS [MENU] 2 or 3 SECONDS TO ST OP SELFCHECK 16 Color display WHT RED GRN Echo-1 T est The echo-1 test checks echo processing circuits in the display unit for proper operation. DISPLA Y ECHO TEST PRESS [MENU] 2 or 3 SECONDS TO ST OP SELFCHECK R29 B358 ° R400 T10 ° ...
-
Furuno CSH-5 MARK-2 - page 63
57 Gray T est The gray test checks for proper display of monochrome characters and markers. Concentric rings and a monochrome test bar are dis- played. PRESS [MENU] 2 or 3 SECONDS TO ST OP SELFCHECK GRA Y TEST ............ Echo-2 T est The echo-2 test checks echo processing circuits in the transceiver and display units. PRESS [MENU] 2 or 3 SECONDS ...
-
Furuno CSH-5 MARK-2 - page 64
58 14. CHARACTERISTICS OF THE UL TRASONIC W A VE IN W A TER The purpose of this chapter is to provide an overview of the charac- teristics of the ultrasonic wave in water . Sound V elocity It is generally known that an ultrasonic wave travels 1500 meters per second in sea water , but in practice, some amount of variation arises depending on the sea ...
-
Furuno CSH-5 MARK-2 - page 65
59 Research in the waters throughout the world has revealed that there is a difference of approximately 100 m/s between the areas where the velocity is maximum and minimum Generally , the velocity increases as follows, provided that salinity density is constant: • 3 m/s for every 1 degree rise of water temperature • 1.7 m/s for every 100 m incr ...
-
Furuno CSH-5 MARK-2 - page 66
60 Refraction An ultrasonic wave transmitted in water does not travel straight but is more or less refracted. This refraction is caused by the variation of propagation velocity in water . If the velocity decreases (temperature decreases) with depth, the top part of the wave front moves faster than its bottom part, and gradually the front bends down ...
-
Furuno CSH-5 MARK-2 - page 67
61 The drawing below shows how temperature variation affects sound propagation with respect to different emitting directions (tilt angles). Beams tilted five and ten degrees bend upward at 400 m and 600 m points respectively . Beams tilted down more than 15 degrees travel in almost straight lines. Between the two beams, a blind zone is cre- ated be ...
-
Furuno CSH-5 MARK-2 - page 68
62 The product of the density (P) and the velocity (C) is called intrinsic acoustic impedance and in the boundary between two media which has extremely different C from each other , most of the acoustic power is reflected and only a small portion penetrates. (In the boundary be- tween water and air , the acoustic energy penetrates with a loss of ap ...
-
Furuno CSH-5 MARK-2 - page 69
63 Reflection Loss (dB) Frequency (kHz) Reflection Loss (dB) Frequency (kHz) Reflection Loss (Mackerel No.1) Reflection Loss (Mackerel No.2) Species Sardine Bonito Horse Mackerel Sea Bream T urbot A verage Incident Direction of Ultrasonic W ave Back Side Head 1 2 0.13 12 0 . 5 0.8-1.2 1.4-2.2 0.4-0.6 0.9 3 0.45 2 12 0 . 4 ...
-
Furuno CSH-5 MARK-2 - page 70
SP-1 SPECIFICA TIONS 1. Display PPI display on 14" non-glare, high resolution color CR T 2. Display Color 16 colors according to echo strength 3. Numeric information Scanning Data (Range, T ilt angle, Gain) T rackball Mark Data (Slant range, Horizontal range, Depth, Bearing) Range/Bearing Mark Data (Range, Bearing) 4. Range/Pulselength Range B ...
-
Furuno CSH-5 MARK-2 - page 71
SP-2 5. AUDIO SEARCH Searching Method Echoes in the direction of the bearing mark are audibly monitored by the built-in loudspeaker . Audio Sector 20˚, 40˚, 80˚, 120˚ (selectable) Audio Output 2W Audio Frequency 800Hz 6. T ransmitter/Receiver T ransmitter High power MOS FET amplifier with 11-step power reduction switch Receiver Low noise superh ...
-
Furuno CSH-5 MARK-2 - page 72
Index-1 INDEX A Absorption 59 AGC control 17 Air bubbles 61 Attenuation 59 AUDIO control 21 AUTO TIL T key 6 C Color test 56 Conti test 55 Control box panel 5 D Data description 25 DEMAG button 3 Diagnostics color test 56 conti test 55 echo-1 test 56 echo-2 test 57 gray test 57 panel test 55 single test 54 SIO test 55 turning on/of f 54 E Echo-1 te ...
-
Furuno CSH-5 MARK-2 - page 73
Index-2 S Scan menu 8 Sea surface reflections 28 Seabed echo 26 SECT OR SCAN key 6, 21 Sidelobe 29 Single test 54 SIO test 51 Sound velocity 58 System configuration 2 System menu 33 T T ilt angle and discriminating fish echoes from bottom 12 for surface fish 13 general selection 1 1 TIL T lever 5, 1 1 T rackball 5 TRANSDUCER switch 5, 1 1, 30 TVG a ...
A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Furuno CSH-5 MARK-2, service manual, brief instructions and user manuals Furuno CSH-5 MARK-2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Furuno CSH-5 MARK-2.
Similar manuals
A complete manual for the device Furuno CSH-5 MARK-2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Furuno CSH-5 MARK-2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Furuno CSH-5 MARK-2.
A complete Furuno manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.
1. Preface and tips on how to use the manual Furuno CSH-5 MARK-2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Furuno CSH-5 MARK-2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Furuno CSH-5 MARK-2, that we can find in the current document
3. Tips how to use the basic functions of the device Furuno CSH-5 MARK-2 - which should help us in our first steps of using Furuno CSH-5 MARK-2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Furuno CSH-5 MARK-2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Furuno CSH-5 MARK-2 in a specific country, if it was not possible to solve the problem on our own.
Do you have a question concerning Furuno CSH-5 MARK-2?
Use the form below
If you did not solve your problem by using a manual Furuno CSH-5 MARK-2, ask a question using the form below. If a user had a similar problem with Furuno CSH-5 MARK-2 it is likely that he will want to share the way to solve it.