Manual Generac Power Systems 04673-2

56 pages 5.14 mb
Download

Go to site of 56

Summary
  • Generac Power Systems 04673-2 - page 1

    PO WER SY STEMS, INC. ® GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled A utomatic Standb y Generators Models: 04673-2 (6 kW NG, 7 kW LP) 04674-2 (12 kW NG, 12 kW LP) 04675-3 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utili ...

  • Generac Power Systems 04673-2 - page 2

    Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weat ...

  • Generac Power Systems 04673-2 - page 3

    T able of Cont ents Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IFC ...

  • Generac Power Systems 04673-2 - page 4

    2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to fo ...

  • Generac Power Systems 04673-2 - page 5

    Generac ® Pow er Systems, Inc. 3 ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, t ...

  • Generac Power Systems 04673-2 - page 6

    Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in ...

  • Generac Power Systems 04673-2 - page 7

    Section 1 — General Information Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 5 1.4 TH E GEN ER A T OR Exh aust En c lo su r e Oi l Di p stic k D a t a D ecal C ontro l P a n el F uel Re g ulato r F uel Inl et G F CI O utle t O il Filte r Batter y Com p artmen t Exh aust En c lo su r e O il Filte r Batter ...

  • Generac Power Systems 04673-2 - page 8

    6 Generac ® Pow er Systems, Inc. Section 1 — General Information Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04673 Model 04674 Mo de l 04675 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP Rated V oltage 120/240 120/240 120/240 R ...

  • Generac Power Systems 04673-2 - page 9

    Generac ® Pow er Systems, Inc. 7 1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resou ...

  • Generac Power Systems 04673-2 - page 10

    4. Remove the engine air in baffle located on the left - hand side of the battery compartment. T wo M6 screws are located on top of the baffle and two M6 screws are located on the inside of the baffle towards the back. 5. Remove the small hose clamp and hose from the fuel regulator . It may be necessary to pry the hose off of the brass fitting usin ...

  • Generac Power Systems 04673-2 - page 11

    Generac ® Pow er Systems, Inc. 9 1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's A UTO/OFF/MANU AL switch to OFF . 2. T urn off utility p ...

  • Generac Power Systems 04673-2 - page 12

    10 Generac ® Pow er Systems, Inc. The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it of f immediately with water; • Where electr olyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electroly ...

  • Generac Power Systems 04673-2 - page 13

    Generac ® Pow er Systems, Inc. 11 8. Connect an accurate AC voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, voltage ...

  • Generac Power Systems 04673-2 - page 14

    12 Generac ® Pow er Systems, Inc. 2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experi ...

  • Generac Power Systems 04673-2 - page 15

    Generac ® Pow er Systems, Inc. 13 Section 2 — Post Installation Start-up and Adjustments Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 6. When frequency is correct at no load, check the AC voltage reading . If voltage is incorrect, the volt- age regulator may require adjustment. Figure 2.3 — Single Cylinder Engine Governor Adjustment ...

  • Generac Power Systems 04673-2 - page 16

    14 Generac ® Pow er Systems, Inc. Section 3 — Operation Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators NOTE: The voltage regulator is housed above the genera- tor's control panel. The regulator maintains a volt- age in direct proportion to frequency . F or example, at 62 Hertz, line -to -neutral voltage will be 124 volts. 3.1 B R EA ...

  • Generac Power Systems 04673-2 - page 17

    Generac ® Pow er Systems, Inc. 15 Upon restoration of utility source voltage above a pre- set level, generator circuit board action signals the transfer switch to transfer loads back to that power supply . After retransfer , the engine is signalled to shut down. The actual sequence of operation is controlled by sensors and timers on a control logi ...

  • Generac Power Systems 04673-2 - page 18

    16 Generac ® Pow er Systems, Inc. Do not attempt to activate the transfer switch manually until all power voltage supplies to the switch have been positively turned off. Failure to turn off all power voltage supplies may result in extr emely hazardous and possibly fatal electrical shock. 5. Use the manual transfer handle inside the trans- fer swit ...

  • Generac Power Systems 04673-2 - page 19

    Generac ® Pow er Systems, Inc. 17 3.7 .3.1 Approximat e Crank Cycle T imes • 15 seconds ON • 7 seconds OFF • 7 seconds ON • 7 seconds OFF • Repeat for 45 seconds Approximately 90 seconds total 3.7 .4 OVERSPEED This feature protects the generator from damage by shutting it down if it happens to run faster than the preset limit. This prote ...

  • Generac Power Systems 04673-2 - page 20

    18 Generac ® Pow er Systems, Inc. NOTE: The unit is supplied with “break-in ” oil. See the “Break -in Procedure,” Section 3.1, for the first required oil change. Any attempt to crank or start the engine before it has been properly serviced with the r ecom- mended oil may result in an engine failur e. 4.3.2 OI L CHANGE PROCEDU R E T o chang ...

  • Generac Power Systems 04673-2 - page 21

    Generac ® Pow er Systems, Inc. 19 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte- nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do ...

  • Generac Power Systems 04673-2 - page 22

    20 Generac ® Pow er Systems, Inc. 4.8 ADJ US TI NG V AL VE CLEAR ANCE After the first 50 hours of operation, adjust the valve clearance in the engine. Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, contact the nearest Generac Authorized dealer for service assis- tance. This is a very important ...

  • Generac Power Systems 04673-2 - page 23

    Generac ® Pow er Systems, Inc. 21 4.1 0 A TTENTION AF TER S U B M ERSION If the generator has been submerged in water , it MUST NOT be started and operated. F ollowing any sub- mersion in water , have a Generac Authorized Dealer thor- oughly clean and dry the generator . 4.1 1 C OR ROSION P RO TECTION P eriodically wash and wax the enclosure using ...

  • Generac Power Systems 04673-2 - page 24

    22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by the nearest Generac Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Nece ...

  • Generac Power Systems 04673-2 - page 25

    Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables ...

  • Generac Power Systems 04673-2 - page 26

    24 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S W ...

  • Generac Power Systems 04673-2 - page 27

    Generac ® Pow er Systems, Inc. 25 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 1 ...

  • Generac Power Systems 04673-2 - page 28

    26 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF ...

  • Generac Power Systems 04673-2 - page 29

    Generac ® Pow er Systems, Inc. 27 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B 2 39 IM2 1 5 1 8 S P 2 24 0V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0V 12 0V 33 NEUTRAL N2 N1 2 3 CUS T O ME R C ...

  • Generac Power Systems 04673-2 - page 30

    28 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12V L OP HT O SP 86 85 IM D D S ...

  • Generac Power Systems 04673-2 - page 31

    Generac ® Pow er Systems, Inc. 29 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C 0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 F ...

  • Generac Power Systems 04673-2 - page 32

    30 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-C CB1 - CIRCUIT BREAKER , MAIN OUTPU T HT O - HI G H O IL TEMPERAT U RE S WIT CH S W1 - A U T O / O FF / MAN U AL S WIT CH CB2 - CIRCUIT BREAKER , ALT. EXCITATIO N TX - TRANSF ...

  • Generac Power Systems 04673-2 - page 33

    Generac ® Pow er Systems, Inc. 31 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-C INP UT 12V dc U TILIT Y CO I L RELAY TRAN S FE R NE U TRA L 120 V 24 0 VA C CUS T O ME R SU PPLIE D 2 3 S W 1 2 39 C 1- 6 0 1 5 17 0 1 8 C 1- 5 0 1 8 0 17 56 1 8 14 1 5A 17 ...

  • Generac Power Systems 04673-2 - page 34

    32 Generac ® Pow er Systems, Inc. 35 68 49 52 PRE PA C KA G ED U NIT S O NL Y 2 0 2 4 9 46 4 3 4 3 37 33 2 5 35 34 2 6 74 77 7 9 35 4 9 82 80 51 4 6 8 80 4 7 2 87 5 86 76 4 8 39 92 1 8 94 91 63 21 1 5 51 71 42 69 1 0 52 4 9 35 51 4 9 11 31 9 50 99 98 72 4 6 41 57 2 7 91 1 56 5 44 60 4 0 19 1 2 71 6 97 22 65 68 63 16 69 1 4 54 47 55 7 5 4 9 30 17 3 ...

  • Generac Power Systems 04673-2 - page 35

    Generac ® Pow er Systems, Inc. 33 ITEM P ART NO . QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPOR T , ROOF FOLDING 3 0F0063 1 ENCLOSURE, FRONT 4 0C7062 1 ENCLOSURE, EXHA UST SIDE 0C7062A 1 ENCLOSURE, EXHA UST SIDE (7KW) 5 0E8811 1 ENCLOSURE, SIDE & BA CK 0E8811A 1 ENCLOSURE, S ...

  • Generac Power Systems 04673-2 - page 36

    34 Generac ® Pow er Systems, Inc. 31 19 3 7 38 22 8, 9 27 45 46 44 48 47 10 3 49 5 1 13 17 5 21 35 23 49 29 21 17 4 2 38 6 7 33 2 20 27 15 40 41 39 45 44 43 1 30 15 11 47 45 24 45 47 49 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No. 0E7 97 4-G ...

  • Generac Power Systems 04673-2 - page 37

    Generac ® Pow er Systems, Inc. 35 ITEM P ART NO . QTY . DESCRIPTION 1 0E7886A 1 CIRCUIT BREAKER 30A X 2P 240V (7KW) 0E7886C 1 CIRCUIT BREAKER 40A X 2P 240V (8.5KW) 0E7886D 1 CIRCUIT BREAKER 45A X 2P 240V (11KW) 0E7886E 1 CIRCUIT BREAKER 50A X 2P 240V (12KW) 0E7886F 1 CIRCUIT BREAKER 60A X 2P 240V (13KW) 0E7886G 1 CIRCUIT BREAKER 70A X 2P 240V (15K ...

  • Generac Power Systems 04673-2 - page 38

    36 Generac ® Pow er Systems, Inc. 1 4 3 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 56 , 57 , 58 , 59 , 60 , 62 , 63 , 64 7, 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 56 , 57 , 58 , 59 , 60 , 63 , 64 53 4 6 48 47 49 50 5 1 5 2 40 38 42 45 44 43 29 143 3 7 26 3 24 1 4 0 3 2 3 35 55 33 36 20 5 7 58 59 6 1 60 6 4 6 2 63 65 1 2 6 3, 32 , 33 , 34 , 35 , 36 , ...

  • Generac Power Systems 04673-2 - page 39

    Generac ® Pow er Systems, Inc. 37 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0E9843 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 3 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372B 3 SEP ARA TOR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S ...

  • Generac Power Systems 04673-2 - page 40

    38 Generac ® Pow er Systems, Inc. Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GT -990/760 Engine – Drawing No. 0E8 7 7 4-K Part 2 ...

  • Generac Power Systems 04673-2 - page 41

    Generac ® Pow er Systems, Inc. 39 ITEM P ART NO . QTY . DESCRIPTION 74 0C5136A 2 KNOB, AIR CLEANER 75 0C3024 1 CO VER, AIRBO X NG/LP 76 0C3040 1 PRE-CLEANER, 77 0C8127 1 ELEMENT , AIR CLEANER 78 0D8564A 1 ASSEMBL Y , MIXER/AIRBO X 990 0D8564B 1 ASSEMBL Y , MIXER/AIRBO X 760 79 0D2595 4 SCREW SHOULDER (8MM) M6-1.0 X 18 80 0D4417 4 W ASHER,R UBBER 1 ...

  • Generac Power Systems 04673-2 - page 42

    40 Generac ® Pow er Systems, Inc. 5 1 23 11 5 3 1 21 53 7 30 13 33 5 2 1 38 3 2 17 28 3 1 3 1 20 14 19 10 17 15 32 2 10 19 16 39 8 6 3 3 2 3 4 30 40 46 45 47 36 1 3 2 4 25 26 34 3 4 48 10 28 27 28 3 2 3 1 18 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D ...

  • Generac Power Systems 04673-2 - page 43

    Generac ® Pow er Systems, Inc. 41 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C9935H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0C6043A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8" CUR VED BL ...

  • Generac Power Systems 04673-2 - page 44

    42 Generac ® Pow er Systems, Inc. 29 3 4 11 2 5 24 43 21 7 13 33 12 38 17 3 2 3 1 28 3 1 20 19 10 17 15 32 16 22 39 8 6 37 14 3 2 40 1 32 24 25 10 30 19 26 28 27 28 3 2 3 1 41 10 18 36 8 35 29 36 36 35 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D ...

  • Generac Power Systems 04673-2 - page 45

    Generac ® Pow er Systems, Inc. 43 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-G ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C7930 1 ST A TOR 12KW 0D2359 ST A TOR 13KW / 15KW 3 0C7944 1 RO TOR 12KW 0D2356 RO TOR 13KW ...

  • Generac Power Systems 04673-2 - page 46

    44 Generac ® Pow er Systems, Inc. 3 2 23 3 4 35 36 45 39 33 20 19 18 43 44 46 11 4 9 29 3 7 2 7 28 30 3 1 17 5 2 47 48 24 38 26 22 40 41 25 25 50 14 12 5 1 13 5 4 16 1 6 1 2 11 10 4 2 5 7 9 8 3 4 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-B Part 1 ...

  • Generac Power Systems 04673-2 - page 47

    Generac ® Pow er Systems, Inc. 45 ITEM P AR T NO . QTY . DESCRIPTION 1 0E3221 1 ASSEMBL Y , CONNECTING ROD 2 0E1466 1 PIN, PIST ON D20 3 021533 1 SET , PIST ON RING 90MM 4 0E2985 1 PIST ON, HC 5 071983 2 RET AINER, PIST ON PIN 20 6 0E8440 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GO VERNOR RC45 8 078658 1 PIN, "R" GO VE ...

  • Generac Power Systems 04673-2 - page 48

    46 Generac ® Pow er Systems, Inc. 19 20 41 21 22 6 40 3 39 24 6 12 7 6 6 6 14 18 17 3 1 30 27 2 45 38 5 29 13 8 10 11 9 18 18 3 4 1 35 33 3 4 4 6 36 37 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-B Part 2 ...

  • Generac Power Systems 04673-2 - page 49

    Generac ® Pow er Systems, Inc. 47 ITEM P AR T NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLO WER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GU ARD , F AN 5 088434 1 WRAPPER, BO TT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLO W CHROME 7 0C4176A 1 WRAPPER, T OP 8 0D9004A 1 ASSY , ST AR TER 9 059985 2 SC ...

  • Generac Power Systems 04673-2 - page 50

    48 Generac ® Pow er Systems, Inc. 17 12 28 11 20 10 3 2 25 21 24 19 23 22 22 15 26 14 13 16 29 18 28 1 2 10 11 27 3 1 4 5 3 2 10 17 1 26 15 14 16 13 3 7 19 9 30 21 25 20 2 4 29 18 23 11 12 28 8 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Gas Regulator – Drawing No. 0D8 7 2 0-G ...

  • Generac Power Systems 04673-2 - page 51

    Generac ® Pow er Systems, Inc. 49 ITEM P AR T NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA T OR HOUSING 2 0F5022 1 SOLENOID COIL, 12VDC 3 0C4647 1 GASKET , SOLENOID 4 0D4166 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 8 0F4795 4 SCREW PPHM SEMS M4-0.7 X 10 9 0C5760J 1 JET , GN 410 ENGINE LP (7KW) 10 0C6606 2* ...

  • Generac Power Systems 04673-2 - page 52

    50 Generac ® Pow er Systems, Inc. Section 8 — Mounting Dimensions Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIEW F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S Ø ...

  • Generac Power Systems 04673-2 - page 53

    Generac ® Pow er Systems, Inc. 51 Section 9 — Notes Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators ...

  • Generac Power Systems 04673-2 - page 54

    52 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y S T A TEM ENT Y OUR W AR RANT Y R IGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and g ...

  • Generac Power Systems 04673-2 - page 55

    Generac ® Pow er Systems, Inc. 53 EM IS SION CONTROL S Y S TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty Period shall begin on the date the new engine or equipment is purchased by/delivere ...

  • Generac Power Systems 04673-2 - page 56

    Part No. 0F0084 Revision H (03/28/05) Printed in U.S.A. Section 1 0 – W arranty Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GENERA C PO WER SYSTEMS ST AND ARD TWO-YEAR LIMITED W ARRANTY FOR GENERA C RESIDENTIAL AND LIGHT COMMERCIAL UNITS For a period of two (2) y ears or two thousand (2,000) hours of operation from the date of sale , w ...

Manufacturer Generac Power Systems Category Portable Generator

Documents that we receive from a manufacturer of a Generac Power Systems 04673-2 can be divided into several groups. They are, among others:
- Generac Power Systems technical drawings
- 04673-2 manuals
- Generac Power Systems product data sheets
- information booklets
- or energy labels Generac Power Systems 04673-2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Generac Power Systems 04673-2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Generac Power Systems 04673-2, service manual, brief instructions and user manuals Generac Power Systems 04673-2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Generac Power Systems 04673-2.

A complete manual for the device Generac Power Systems 04673-2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Generac Power Systems 04673-2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Generac Power Systems 04673-2.

A complete Generac Power Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Generac Power Systems 04673-2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Generac Power Systems 04673-2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Generac Power Systems 04673-2, that we can find in the current document
3. Tips how to use the basic functions of the device Generac Power Systems 04673-2 - which should help us in our first steps of using Generac Power Systems 04673-2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Generac Power Systems 04673-2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Generac Power Systems 04673-2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Generac Power Systems 04673-2?

Use the form below

If you did not solve your problem by using a manual Generac Power Systems 04673-2, ask a question using the form below. If a user had a similar problem with Generac Power Systems 04673-2 it is likely that he will want to share the way to solve it.

Copy the text from the picture