Manual Honeywell 62-0342-01

16 pages 1.08 mb
Download

Go to site of 16

Summary
  • Honeywell 62-0342-01 - page 1

    INST ALLATION MANUAL 62-0342-01 SUB Series Interval Dat a Recorders PRE-INST ALLATION INFORMATION The SUB Series Interval Data Recorder (IDR) is an energy data collection device. Installation must be performed by qualified personnel only and mu st be in accordance with local and national electri cal codes. Honeywell and its representatives are not ...

  • Honeywell 62-0342-01 - page 2

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 2 3. Modular Jacks & Screw-T ype Connectors (SUBIDR-16 ONL Y): Supplied with 8 modular jacks and 8 screw-type connectors. Used with a mixtur e of Honeywell a nd third- party meters. (Requires ex ternal power supply .) Fig. 3. ID R with both t ypes of co nnectors. MECHANICAL INST ALLATION IMPORT A ...

  • Honeywell 62-0342-01 - page 3

    SUB SERIES INTERVAL DATA RECORDERS 3 62-0342—01 removed. The third-party mete r IDR uses a DIP switch to perform this function. This switch is preset at the factory and requires no further adjustment. Fig. 5. Overvie w of main circuit board. MAIN CIRCUIT BOARD V ISUAL CHECKS Once you have conne cted meter #1 to jack #1 in the IDR, the IDR should ...

  • Honeywell 62-0342-01 - page 4

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 4 IMPORTANT: The AC adapter is designed to be used with a 120 V AC outlet only . 5. The IDR should now be energ ized. Perform the visual checks outlined in section 4. NOTE: The AC adapter provides an isolated 18 V AC/300 mA power source for the IDR. SERIAL COMMUNICATIONS Hardwired System using the SU ...

  • Honeywell 62-0342-01 - page 5

    SUB SERIES INTERVAL DATA RECORDERS 5 62-0342—01 Using the USB connection on your computer As an alternative to the SUB-RS 2 32K converter , we offer the SUB-USBK that allows you to co nvert the RS485 output from your IDRs for direct connect to your USB connection on your computer . Baud Rate Selection The communication baud rate is selected by me ...

  • Honeywell 62-0342-01 - page 6

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 6 APPENDIX B - LED INDICATORS Fig. 10. LED indi cators. L1-Green LED Serial Communications P ow er Supply A lwa ys "ON" (Indicates power supply is oka y if LED is ON) D6-Clear Red LED System Error Alwa ys "OFF" when system is operating normally D1-Green LED D2-Y ellow LED See &quo ...

  • Honeywell 62-0342-01 - page 7

    SUB SERIES INTERVAL DATA RECORDERS 7 62-0342—01 APPENDIX C - IDR CIRCUIT BOARD COMPONENT S Fig. 1 1. IDR circuit board compon ents. J3-J4-RS-485 Communications Jac ks See "Serial Communications" (P orts used to connect one IDR to another IDR or K ey) Baud Rate Selection See "Serial Communications" (Selects communication baud r ...

  • Honeywell 62-0342-01 - page 8

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 8 APPENDIX D - SYSTEM WIRING GUIDES Fig. 12. Wiring overv iew for SUBIDR-8. Note: Meter 1 must be installed within 100 feet of IDR. Meters 2-8 must be installed within 500 feet of IDR. (Up to 8 Meters) (One of three channels shown f or clarity .) (Up to 8 Meters) ~ ~ Channel 1 of 3 4-Conductor Flat M ...

  • Honeywell 62-0342-01 - page 9

    SUB SERIES INTERVAL DATA RECORDERS 9 62-0342—01 Fig. 13. Wiring overview for SUBIDR-16. Note: Meter 1 must be installed within 100 feet of IDR. Meters 2-8 must be installed within 500 feet of IDR. (Up to 16 Meters) (One of three channels shown f or clarity .) (Up to 16 Meters) ~ ~ Channel 1 of 3 4-Conductor Flat Modular Cable Up to 4000 Feet T ot ...

  • Honeywell 62-0342-01 - page 10

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 10 APPENDIX E - HARDWIRED SYSTEM CONFIGURATION DIAGRAMS Fig. 14. Hard-wiring the SUBIDR-8. Up to 8 Meters Up to 8 Meters Channel 2 ~ ~ ~ ~ Channel 1 Channel 3 Up to 4000 Feet T otal Up to 4000 Feet T otal Up to 52 SUBIDR-8’ s Up to 52 SUBIDR-8’ s NOTE: Meter #1 must be installed within 100 f eet ...

  • Honeywell 62-0342-01 - page 11

    SUB SERIES INTERVAL DATA RECORDERS 11 62-0342—01 Fig. 15. Hard-wir ing the SUBIDR-16 . SUBIDR-16, Using Other Utility-T ype Meters (Gas, W ater , Etc.) Up to 16 Meters Up to 16 Meters Channel 2 ~ ~ ~ ~ Channel 1 Channel 3 Up to 4000 F eet T otal Up to 4000 F eet T otal Up to 26 SUBIDR-16’ s Up to 26 SUBIDR-16’ s NO TE: Meter s m ust be instal ...

  • Honeywell 62-0342-01 - page 12

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 12 APPENDIX G - IDR T ECHNICAL SPECIFICATIONS Enclosure: Lockable steel JIC box NEMA 12. Dimensions: 9.5” H x 6.75” W x 3.875” D. Knockout s: Three (3) on bottom of enclosure (3/4” Cond.) Power Supply: Powered by meter or optional 120 V AC adapter. Back Up: Lithium Power Cell L TC-3PN (10 yea ...

  • Honeywell 62-0342-01 - page 13

    SUB SERIES INTERVAL DATA RECORDERS 13 62-0342—01 LIMITED W ARRANTY Subject to the exclusions listed belo w , Honeywell will either repair or replace (at it s option) any product that it manufactures and which contains a defect in material or workmanship. The following exclusions app ly: 1. This Limited W arranty is only effective for a period of ...

  • Honeywell 62-0342-01 - page 14

    SUB SERIES INTERVAL DATA RECORDERS 62-0342—0 1 14 ...

  • Honeywell 62-0342-01 - page 15

    SUB SERIES INTERVAL DATA RECORDERS 15 62-0342—01 ...

  • Honeywell 62-0342-01 - page 16

    SUB SERIES INTERVAL DATA RECORDERS Automation and Co ntrol Solutions Honeywell Internationa l Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 www.honeywell.com/buil dingsolutions ® U.S. Regi stered T rademark © 201 1 Honeywell International Inc. 62-0342—01 M.S. ...

Manufacturer Honeywell Category Barcode Reader

Documents that we receive from a manufacturer of a Honeywell 62-0342-01 can be divided into several groups. They are, among others:
- Honeywell technical drawings
- 62-0342-01 manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell 62-0342-01
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell 62-0342-01.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell 62-0342-01, service manual, brief instructions and user manuals Honeywell 62-0342-01. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell 62-0342-01.

Similar manuals

A complete manual for the device Honeywell 62-0342-01, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell 62-0342-01 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell 62-0342-01.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell 62-0342-01 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell 62-0342-01, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell 62-0342-01, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell 62-0342-01 - which should help us in our first steps of using Honeywell 62-0342-01
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell 62-0342-01
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell 62-0342-01 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell 62-0342-01?

Use the form below

If you did not solve your problem by using a manual Honeywell 62-0342-01, ask a question using the form below. If a user had a similar problem with Honeywell 62-0342-01 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)