Manual Aprilaire 1700

16 pages 0.88 mb
Download

Go to site of 16

Summary
  • Aprilaire 1700 - page 1

    Wire Routing Port Wiring Access Filter Access Humidity Control Inlet Drain On/Off Switch Filter Access Service Access Port Outlet Safety and Installation Instructions Model 1700 Dehumidifier INST ALLER – PLEASE NOTE! 1. Installation must conform to all applicable codes. 2. A dedicated 15 Amp circuit is required for proper operation of the dehumid ...

  • Aprilaire 1700 - page 2

    2 SAFETY INSTRUCTIONS OVERVIEW SPECIFICA TIONS WARNING • This product must be installed by a qualified heating and air conditioning contractor . Failure to do so could result in serious injury from electrical shock or damage to product. • 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting install ...

  • Aprilaire 1700 - page 3

    The included condensate trap must be installed to the Model 1700. Use PVC primer and cement to connect the trap to the drain outlet on the Model 1700. The drain outlet is located near the On/Off toggle switch. Note orientation of trap prior to cementing. The high side of the trap mates with the Model 1700. The adjustable legs on the Model 1700 must ...

  • Aprilaire 1700 - page 4

    4 WHOLE HOUSE INST ALLA TION AND OPERA TION In this configuration the dehumidifier will pull air from the return duct. The air passes through the dehumidifier , where moisture is removed, and then returned to the HV AC system downstream of the cooling coil in the supply plenum. This installation is used when the HV AC unit conditions the area where ...

  • Aprilaire 1700 - page 5

    5 WHOLE HOUSE INST ALLA TION AND OPERA TION (CONTINUED) THERMOST A T HV AC EQUIPMENT TRANSFORMER (10 V A min) 24 V AC DAMPER N.C. BACKFLOW CONTROL DEHUMIDIFIER DAMPERS Rf Y - W Gh Gs Cf VENT HV AC EQUIP REMOTE DEH B + A R C W Y Y W G C R G ODT SENSOR SWITCH FLOA T FIGURE 4 – WIRING 90-962 FIGURE 5 – SETTINGS 90-963 CYCLE TIME TEST 60 OFF 0 MIN ...

  • Aprilaire 1700 - page 6

    6 LOCALIZED INST ALLA TION AND OPERA TION In this configuration the dehumidifier will pull air from an area in the home. The air passes through the dehumidifier , where moisture is removed, and then is returned to the area. This installation is used when the HV AC unit conditions an area other than where dehumidification is needed. An unconditioned ...

  • Aprilaire 1700 - page 7

    7 LOCALIZED INST ALLA TION AND OPERA TION (CONTINUED) THERMOST A T HV AC EQUIPMENT CONTROL DEHUMIDIFIER DAMPERS Rf Y - W Gh Gs Cf VENT HV AC EQUIP REMOTE DEH B + A R C W Y Y W G C R G ODT SENSOR SWITCH FLOA T FIGURE 7 – WIRING 90-964 FIGURE 8 – SETTINGS 90-965 CYCLE TIME TEST 60 OFF 0 MIN MIN. 30 MIN. ON 1234 2 HOUR 3 HOUR 30 MIN. 1 HOUR CYCLE ...

  • Aprilaire 1700 - page 8

    8 WHOLE HOUSE / LOCALIZED CONVERTIBLE INST ALLA TION AND OPERA TION In this configuration the dehumidifier will automatically switch between whole-house dehumidification when the HV AC equipment is on, and localized dehumidification when the equipment is off. This installation is used to dehumidify a whole hous e and a separate unconditioned space ...

  • Aprilaire 1700 - page 9

    9 WHOLE HOUSE / LOCALIZED CONVERTIBLE INST ALLA TION AND OPERA TION (CONTINUED) THERMOST A T HV AC EQUIPMENT DEHUMIDIFIER SYSTEM DAMPERS CONTROL DEHUMIDIFIER TRANSFORMER (40 V A min) 24 V AC DAMPERS Rf Y - W Gh Gs Cf VENT HV AC EQUIP . REMOTE DEH B + A R C W Y Y W G C R G ODT SENSOR SWITCH FLOA T WIRE NUT FIGURE 10 – WIRING 90-966 FIGURE 11 – S ...

  • Aprilaire 1700 - page 10

    10 VENTILA TION / FAN CYCLING SETTINGS The Aprilaire Dehumidifier has the option to monitor HV AC heating, cooling and fan calls to assure the HV AC fan has operated a predetermined amount of time each 1/2, 1, 2 or 3 hours. The dehumidifier can also open a normally closed damper in an outdoor air intake to ventilate during this predetermined amount ...

  • Aprilaire 1700 - page 11

    11 VENTILA TION / FAN CYCLING SETTINGS (CONTINUED) • An Aprilaire ® Normally-Closed Damper (Model 6506) should be installed in the outside air intake. It should be wired to the terminals labeled “VENT DAMPER” on the dehumidifier control board. Follow all installation instructions supplied with the damper . Refer to each installation for duct ...

  • Aprilaire 1700 - page 12

    12 DIP SWITCH DEFINITIONS MODEL 70 – OFF/ON (SYSTEM SETUP SWITCH #1): HV AC FAN – OFF/ON (SYSTEM SETUP SWITCH #2): WHL HOUSE / CONVERTIBLE (SYSTEM SETUP SWITCH #3): VENT -AUTO / VENT -TIMED (SYSTEM SETUP SWITCH #4): Determines use of internal RH and temperature sensor or use of the RH and temperature sensor on the Living Space Control (Model 70 ...

  • Aprilaire 1700 - page 13

    13 SYSTEM CHECKOUT 1. Check the wiring to the HV AC equipment. 2. Rotate the main control knob clockwise to the “TEST” position. 3. If all is set up properly , the dehumidifier blower will turn on. The compressor will turn on after the dehumidifier blower has run for 30 seconds. After 1 minute the dehumidifier blower and compressor will shut of ...

  • Aprilaire 1700 - page 14

    14 TROUBLESHOOTING GUIDE SYMPTOM TROUBLESHOOTING PROCEDURE / POSSIBLE REASON Dehumidifier is not draining properly . • Check condensate trap to be sure it is clear . • Check drain line for continuous slope. Dehumidifier is producing hot air . • Reheat of outgoing air will cause a temperature increase across the dehumidifier . • Unit will po ...

  • Aprilaire 1700 - page 15

    15 TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOM TROUBLESHOOTING PROCEDURE / POSSIBLE REASON The ventilation damper does not open when the HV AC fan is active. • The damper will not open if the cycle time within the current period has already been met. For instance if the cycle time is set to 5 minutes and the control has already ventilated for 5 min ...

  • Aprilaire 1700 - page 16

    P .O. BOX 1467 • MADISON, WI 53701-1467 • PHONE: 800/334-601 1 • F AX: 608/257-4357 • www.aprilairecontractor .com 10006238 5.05 B2203431C DEHUMIDIFIER SEQUENCE OF OPERA TION IF THE DEHUMIDIFIER IS NOT WIRED TO THE HV AC EQUIPMENT , THE DEHUMIDIFIER WILL SAMPLE A T THE END OF THE CYCLE PERIOD. With 3 minutes left in the Cycle Period, the de ...

Manufacturer Aprilaire Category Dehumidifier

Documents that we receive from a manufacturer of a Aprilaire 1700 can be divided into several groups. They are, among others:
- Aprilaire technical drawings
- 1700 manuals
- Aprilaire product data sheets
- information booklets
- or energy labels Aprilaire 1700
All of them are important, but the most important information from the point of view of use of the device are in the user manual Aprilaire 1700.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Aprilaire 1700, service manual, brief instructions and user manuals Aprilaire 1700. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Aprilaire 1700.

Similar manuals

A complete manual for the device Aprilaire 1700, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Aprilaire 1700 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Aprilaire 1700.

A complete Aprilaire manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Aprilaire 1700 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Aprilaire 1700, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Aprilaire 1700, that we can find in the current document
3. Tips how to use the basic functions of the device Aprilaire 1700 - which should help us in our first steps of using Aprilaire 1700
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Aprilaire 1700
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Aprilaire 1700 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Aprilaire 1700?

Use the form below

If you did not solve your problem by using a manual Aprilaire 1700, ask a question using the form below. If a user had a similar problem with Aprilaire 1700 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)