  • Keating Of Chicago Gas Custom Pasta System - page 1

    CUST OM P AST A ™ SYSTEM GAS SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Gas Pasta 0107 9/07 ...

  • Keating Of Chicago Gas Custom Pasta System - page 2

    i This operating, installation, and service manual should be given to the user . The operator of the Pasta System should be familiar with the functions and operation of the cooker . This manual must be kept in a prominent, easily reachable location near the Pasta System. P OST T H I S L A B E L I N A P R O M I N E NT LO CA T I O N O N Y O UR UNI T ...

  • Keating Of Chicago Gas Custom Pasta System - page 3

    T ABLE OF CONTENTS SECTION I INTRODUCTION General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Model V ariations . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .1-3 SECTION II INST ...

  • Keating Of Chicago Gas Custom Pasta System - page 4

    I INTRODUCTION GENERAL Keating Pasta Gas Systems are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated in Keating Pasta Gas Systems. ST ANDARD FEA TURES  Highly polished stainless steel vessel  Highly polished stainless steel front  Highly polished stainle ...

  • Keating Of Chicago Gas Custom Pasta System - page 5

     Y ou must maintain this appliance free and clear from combustibles.  Y ou must maintain the following minimum clearances from combustible and noncombustible construction:  Adequate clearance for servicing and proper operation must be maintained. Y our Pasta System is designed to be serviced from the front.  Keating commercial Pasta Sys ...

  • Keating Of Chicago Gas Custom Pasta System - page 6

    IF NOT INST ALLED, OPERA TED AND MAINT AINED IN ACCORDANCE WITH THE MANUF ACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBST ANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEA TH OR SERIOUS ILLNESS AND WHICH ARE KNOWN T O THE ST A TE OF CALIFORNIA T O CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. II INST ALLA TION This ...

  • Keating Of Chicago Gas Custom Pasta System - page 7

    4 Figure 2-1 RESTRAINING DEVICES On Pasta System inst allations with casters, casters and jam nuts must be completely tightened. Adequate means must also be provided to limit the movement of the appliance without depending on the connector , the quick-disconnect device or its associated piping to limit the appliance movement. Connectors must comply ...

  • Keating Of Chicago Gas Custom Pasta System - page 8

    5 A 3 / 4 " IPS manual gas valve is shipped with each single Pasta System for field inst allation. Batteries have a factory installed manual gas valve for each Past a System. The required gas pressure for proper operation of each Pasta System is 4" water column (WC) for natural gas and 10” water column (WC) for Propane gas at the burner ...

  • Keating Of Chicago Gas Custom Pasta System - page 9

    6 Constructional changes to the area where the Pasta System is installed shall not af fect the air supply to the Pasta System. The installation, st art-up and changes required when changing from one gas type to another can be performed only by a certified professional. The Pasta System is intended only for commercial use and is to be operated only ...

  • Keating Of Chicago Gas Custom Pasta System - page 10

    2. Turn “On” main power On/Of f switch (located between the amber and green indicating lights). 3. Light the const ant pilot (located next to left burner as you face it). If your Pasta System has an optional spark ignitor , omit this step. 4. Activate pilot light moment ary switch (let top corner) and hold about 30 seconds, releasing it after p ...

  • Keating Of Chicago Gas Custom Pasta System - page 11

    1. T urn off Pasta System and open the door . Figure 3-3 Drain, drain valve and overflow tubing 2. Slowly turn handle. The drain valve will be completely open after 1 / 4 turn. CLEANING When cleaning and boiling out your Pasta System, use white vinegar and Keating Klenzer to keep your Pasta System in top condition. Once your Pasta System vessel is ...

  • Keating Of Chicago Gas Custom Pasta System - page 12

    B. How to program the “Keating” Electronic Timer  The Keating Electronic T imer is programmable to four different timer ranges with two dif ferent alarm modes for each time range.  The timers are shipped from the factory preset to program 5: Minutes : seconds (00:01 to 59:59) with continuous alarm  T o program another time range or ala ...

  • Keating Of Chicago Gas Custom Pasta System - page 13

    10 (at 1-800-KEA TING) before calling a local service company PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily , weekly , monthly and yearly intervals as necessary . Following preventive maintenance procedures will help keep your Pasta System working ef ficiently . Proper care and servicing will lead to years of quality perform ...

  • Keating Of Chicago Gas Custom Pasta System - page 14

    auto-fill system. The water level is controlled by two circuit boards and two sensors. The sensors are located in the tube on the right side of the overflow deck. The upper sensor controls the water level and the lower sensor controls the low water safety shut-off system. Once the water On/Off switch is turned on, the blue light will come on and st ...

  • Keating Of Chicago Gas Custom Pasta System - page 15

    12 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won’t light. a. Gas isn't turned on. b. Clogged constant pilot tubing. c. Constant pilot valve isn't turned on. a. T urn manual gas valve on. If using flexible connector with quick disconnect, make sure quick disconnect is completely engaged. b. T urn Custom Pasta System and manual gas v ...

  • Keating Of Chicago Gas Custom Pasta System - page 16

    13 PROBLEM PROBABLE CAUSE SOLUTION Flames come out front. a. Burners misaligned. b. Exhaust problems. c. Radiants have slipped forward. d. Flue blockage. a. Adjust position of burners. b. Install deflector to block down draft. Install or adjust flue restrictors. If problem persists, cont act your HV AC representative. c. Reposition radiants. d. T u ...

  • Keating Of Chicago Gas Custom Pasta System - page 17

    14 PROBLEM SOLUTIONS (Follow Sequentially) W ater always filling. a. Clean sensors thoroughly with brush and vinegar . b. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. c. If filling persists, ground out the top sensor (if filling stops, replace sensor – Part #010212). d. If filling persists after grounding out the se ...

  • Keating Of Chicago Gas Custom Pasta System - page 18

    15 REPLACEMENT OF A AND B BOARDS 1. Locate the wiring diagram. it will help later with connecting wires to the board. 2. Disconnect wires from the board. 3. Unscrew mounting screws. There are three of them per board. 4. Replace the board. 5. Reconnect the wires. 6. Adjust sensitivity . 7. Close the box. 8. Seal the box using silicone and filling al ...

  • Keating Of Chicago Gas Custom Pasta System - page 19

    16 CUSTOM P AST A ™ SYSTEM CONTROL P ANEL WITH DIGIT AL TIMERS V SER VICE DIAGNOSIS  The burners when on will produce clear blue flames directed at the inside walls of the heat transfer tubes. The radiant’s fins, located towards the rear of each transfer tube, will glow bright red, helping to ensure optimum heat distribution into the Pasta S ...

  • Keating Of Chicago Gas Custom Pasta System - page 20

    17 ITEM DESCRIPTION QUANTITY P ART NUMBER 1 TOGGLE SWITCH - PILOT ON 1 004507 2 INDICA TING LIGHT , AMBER - PILOT ON 1 031624 3 TOGGLE SWITCH – MAIN ON-OFF 1 004501 4 INDICA TING LIGHT , GREEN - SECONDARY BURNER ON 1 009375 5 UNUSED 3 ------ 6 DIGIT AL TIMER(S) 2 056921 7 THERMOST A T 2 031466 8 DIAL PLA TE 2 034975 9 THERMOST A T KNOB 2 004163 1 ...

  • Keating Of Chicago Gas Custom Pasta System - page 21

    18 GAS P AST A SYSTEM ASSEMBL Y I ITEM DESCRIPTION MODELS P ART# 14 18 20 24 1 GAS V AL VE, 120V ALL NA TURAL GAS 004269 1 1 1 1 LP 008123 1 1 1 1 2 RUNNER PILOT TUBE SEE BELOW 1 1 1 1 3 CONST ANT PILOT ASSEMBL Y ALL (1.8"X28") 004259 1 1 1 1 4 CONST ANT PILOT V AL VE ALL 004266 1 1 1 1 5 RUNNER PILOT GAS COCK STRAIGHT (W/005743) ALL 0154 ...

  • Keating Of Chicago Gas Custom Pasta System - page 22

    19 ITEM DESCRIPTION MODELS P ART# 14 18 20 24 22 RADIANT , 2 - FINS ALL 000041 3 4 4 5 23 BURNER 008264 2 2 2 3 BURNER CM 004088 2 24 SECONDAR Y BURNER ALL 004088 1 2 2 2 25 SECONDAR Y GAS SOLENOID ALL 037033 1 2 2 2 26 P AST A VESSEL CALL 1-800-KEA TING 1 1 1 1 27 W A TER LEVEL SENSORS ALL 010212 2 2 2 2 28 DRAIN V AL VE, FRONT , 1" 016345 1 ...

  • Keating Of Chicago Gas Custom Pasta System - page 23

    20 P AST A SYSTEM WIRING DIAGRAM ...

  • Keating Of Chicago Gas Custom Pasta System - page 24

    21 GAS P AST A SYSTEM WITH BASKET -LIFT WIRING DIAGRAM ...

  • Keating Of Chicago Gas Custom Pasta System - page 25

    L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after J ...

  • Keating Of Chicago Gas Custom Pasta System - page 26

    KEA TI N G LI M ITE D W AR RANTY C AR D PLEASE COMPLETE AND MAIL A T ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED COMP ANY : ____________________________________________________________________________________________________ ADDRESS: ____________________________________________________________________________________________________ CIT ...

Manufacturer Keating Of Chicago Category Pasta Maker

Documents that we receive from a manufacturer of a Keating Of Chicago Gas Custom Pasta System can be divided into several groups. They are, among others:
- Keating Of Chicago technical drawings
- Gas Custom Pasta System manuals
- Keating Of Chicago product data sheets
- information booklets
- or energy labels Keating Of Chicago Gas Custom Pasta System
All of them are important, but the most important information from the point of view of use of the device are in the user manual Keating Of Chicago Gas Custom Pasta System.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Keating Of Chicago Gas Custom Pasta System, service manual, brief instructions and user manuals Keating Of Chicago Gas Custom Pasta System. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Keating Of Chicago Gas Custom Pasta System.

A complete manual for the device Keating Of Chicago Gas Custom Pasta System, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Keating Of Chicago Gas Custom Pasta System by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Keating Of Chicago Gas Custom Pasta System.

A complete Keating Of Chicago manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Keating Of Chicago Gas Custom Pasta System - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Keating Of Chicago Gas Custom Pasta System, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Keating Of Chicago Gas Custom Pasta System, that we can find in the current document
3. Tips how to use the basic functions of the device Keating Of Chicago Gas Custom Pasta System - which should help us in our first steps of using Keating Of Chicago Gas Custom Pasta System
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Keating Of Chicago Gas Custom Pasta System
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Keating Of Chicago Gas Custom Pasta System in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Keating Of Chicago Gas Custom Pasta System?

Use the form below

If you did not solve your problem by using a manual Keating Of Chicago Gas Custom Pasta System, ask a question using the form below. If a user had a similar problem with Keating Of Chicago Gas Custom Pasta System it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)