Manual Emulex VMWARE LP21000

17 pages 1 mb
Download

Go to site of 17

Summary
  • Emulex VMWARE LP21000 - page 1

    Deployment Guide: Network Convergence with Emulex LP21000 CNA and VMware® ESX Server How to deploy Converged Networking with VMware ESX Server Using Emulex FCoE Technology ...

  • Emulex VMWARE LP21000 - page 2

    2 Table of Contents Introduction .................................................................................................................. ....................... 3  Drivers of Networ k Convergence ................................................................................................ ..... 3  Benefits of FCoE Enable d Netwo ...

  • Emulex VMWARE LP21000 - page 3

    3 Intr oduction Fibre Channel over Ethernet (FCoE) technology en ables convergence of storage and LAN networks in enterprise data centers. The key benefits of FCoE in clude cost savings and improv ed operating efficiencies, but the technology is new and deployment configur ations are less well under stood than proven Fibre Channel solutions. Server ...

  • Emulex VMWARE LP21000 - page 4

    4 Figure 1: Key factors driving network convergence. Network convergence, enabled by FCoE, helps addres s the network infrastructure sprawl while fully complementing server consolidation efforts and improv ing the efficiency of the en terprise data center. Benefits of FCoE Enabled Netw ork Con v ergence An FCoE enabled converged network provides th ...

  • Emulex VMWARE LP21000 - page 5

    5 • Increased IT efficiency and business agility A converged network streamlines and eliminates repe ated administrative tasks such as server and network provisioning with a “wire once” deployme nt model. The converged network also improves business agility letting data centers dynamically an d rapidly respond to requests for new or expanded ...

  • Emulex VMWARE LP21000 - page 6

    6 By contin existing i n Intr o d Emulex is Converg e networki n convergi n server en v Fi Enha n uing to main t n vestments i n d uction t one of the l e e d Network A n g applicatio n n g networkin g v ironments. gure 3: Net w n ced Etherne t t ain Fibre Ch a n Fibre Chan n t o Emul e ading propo n A dapter (CN A n s in enterpri s g and storage w ...

  • Emulex VMWARE LP21000 - page 7

    7 Servers supporting PCI Express (x8 or higher) will be able to utilize the full potential of the Emulex LP21000’s 2x10Gb/s Ethernet interfaces, balancing both storage and networking I/O requirements. The priority flow control prevents degradation of traffi c delivery and enhanced transmission selection enables partitioning and guaranteed service ...

  • Emulex VMWARE LP21000 - page 8

    8 Con verg ed Networking with FC oE in an ESX En vir onment Server virtualization is one of the key drivers of FCoE deployment . FCoE enabled network convergence significantly reduces the number of cables, switch ports and adapters as show in Figure 6. Figure 6 : Effects of Convergence using a CNA in a Rack-mount Server running ESX The following se ...

  • Emulex VMWARE LP21000 - page 9

    9 machines hosted on the ESX server. The configuration and manageability of the ESX server is performed by VMware vCenter® Server (typicall y residing on a separate management server). Figure 7 : The hypervisor/VMKernel views the CNA as an HBA and a NIC When an Emulex LP21000 CNA is installed on an ESX server, the adapter is visible in the vCenter ...

  • Emulex VMWARE LP21000 - page 10

    10 Figure 8: Two LP21000 CNAs appear as Fibre Channel storage adapters Figure 9: Use the “Add Storage Wizard” to create the datastore By selecting stor age from within the configuration tab (see Figure 9), the Add Storage Wizard can be used to create the data stores and select either the Virtua l Machine File System (VMFS), or Raw Device Mappin ...

  • Emulex VMWARE LP21000 - page 11

    11 IT organizations can also leverage the Emulex Virtual HBA technology, based on the ANSI T11 N_Port ID Virtualization (NPIV) standard. This virtualization tec hnology allows a single physical CNA or HBA port to function as multiple virtual ports (VPorts), with ea ch VPort having a separate identity in the Fabric. NPIV support began with ESX Serve ...

  • Emulex VMWARE LP21000 - page 12

    12 In this configuration, even in the extreme case of a CNA failure, the links for storage and networking can be immediately failed over with no interruption to applications. Within ESX, multipathing can be configured from th e configuration tab by selecting storage, followed by selecting properties for the appropriate data store. From the data sto ...

  • Emulex VMWARE LP21000 - page 13

    13 Configuring the LP21000 as a Network Adapter Upon installation, the LP21000 appears as a 10 Gigabi t NIC in th e Configuration Tab’s network adapter view, as shown in Figure 13 where two LP21000s appear s as two 10 Gigabit network adapters (also shown are two 100 Mbps NICs which are built into the server motherboar d.). Figure 13 : Two LP21000 ...

  • Emulex VMWARE LP21000 - page 14

    14 Configuring the LP21000 for NIC Teaming in ESX NIC teaming occurs when multiple up link adapters are associated with a single vSwitch to form a team. A team can share the load of traffic between physical and virtual networks or provide passive f ailover in the event of a hardware failure or network outage. Figure 14 shows the configuration of tw ...

  • Emulex VMWARE LP21000 - page 15

    15 Unified management of Emulex Fibre Channel HBAs and CNAs • VPort monitoring and configuration • Online boot from SAN configuration • On-line WWN management • Flexible, customizable reporting capability The availability of graphical user interface (GUI) and command l ine interface (CLI) options provides greater flexibility with HBAnyware. ...

  • Emulex VMWARE LP21000 - page 16

    16 Conclusion Server virtualization has been one of the key drivers of converged networks in the data center. A converge d network fully complements server virtualization and enables the roll out of on -demand se rvices where applications and network services are provisioned on the fly. Fibre Channel over Ethernet technology enables network converg ...

  • Emulex VMWARE LP21000 - page 17

    VMware, Inc. 3401Hillvie w Drive P a lo Alto CA 94304 USA T el 650-427-5000 www .vmware.com Emulex Corp . 3333 Susan St reet Costa Mesa CA 926 26 USA T el 714-662-5600 www .emulex.com © Emulex Corporation. All Rights Reserved. No part of this do cument may be r eproduced by any means or translated to any electronic medium without prior written con ...

Manufacturer Emulex Category Server

Documents that we receive from a manufacturer of a Emulex VMWARE LP21000 can be divided into several groups. They are, among others:
- Emulex technical drawings
- VMWARE LP21000 manuals
- Emulex product data sheets
- information booklets
- or energy labels Emulex VMWARE LP21000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emulex VMWARE LP21000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emulex VMWARE LP21000, service manual, brief instructions and user manuals Emulex VMWARE LP21000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emulex VMWARE LP21000.

Similar manuals

A complete manual for the device Emulex VMWARE LP21000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emulex VMWARE LP21000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emulex VMWARE LP21000.

A complete Emulex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emulex VMWARE LP21000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emulex VMWARE LP21000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emulex VMWARE LP21000, that we can find in the current document
3. Tips how to use the basic functions of the device Emulex VMWARE LP21000 - which should help us in our first steps of using Emulex VMWARE LP21000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emulex VMWARE LP21000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emulex VMWARE LP21000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emulex VMWARE LP21000?

Use the form below

If you did not solve your problem by using a manual Emulex VMWARE LP21000, ask a question using the form below. If a user had a similar problem with Emulex VMWARE LP21000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)