  • Bunn VP17A - page 1

    OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 10860.0001C 9/00 ©1997 Bunn-O-Matic Corporation BU N N ® VP17A ...

  • Bunn VP17A - page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It is only for indoor use on a sturdy counter or shelf. W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and ap ...

  • Bunn VP17A - page 3

    Page 3 #00831.0000 # 00658.0000 # 02763.0000 10860.1 091300 USER NOTICES (cont.) ...

  • Bunn VP17A - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. ELECTRICAL HOOK-UP CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding ...

  • Bunn VP17A - page 5

    Page 5 CLEANING 1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. 2. Check and clean the sprayhead. The sprayhead holes must always remain open. 3. With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. Whe ...

  • Bunn VP17A - page 6

    Page 6 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by ...

  • Bunn VP17A - page 7

    Page 7 TROUBLESHOOTING (cont.) PROBLEM Spitting or excessive steaming Dripping from sprayhead Beverage overflows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate ...

  • Bunn VP17A - page 8

    Page 8 TROUBLESHOOTING (cont.) PROBLEM Weak beverage (cont.) Dry coffee grounds remain in the funnel Brewer is making unusal noises Cool beverage serving tempera- ture PROBABLE CAUSE REMEDY 4. Funnel Loading 5. Water Temperature 1. Funnel Loading 1. Tank Heater 1. ON/OFF Warmer Switch(s) 2. Warmer Element(s) The BUNN ® paper filter must be centere ...

  • Bunn VP17A - page 9

    Page 9 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service per ...

  • Bunn VP17A - page 10

    Page 10 FIG. 3 CONTROL THERMOSTAT TERMINALS P1263 CONTROL THERMOSTAT Location: The control thermostat is located inside the trunk on the upper left side of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. With a voltmeter, check the voltage across the blue wire on the control thermostat and red insert on te ...

  • Bunn VP17A - page 11

    Page 11 ON/OFF WARMER SWITCH P1166.45 FIG. 4 ON/OFF WARMER SWITCH SERVICE (cont.) Location: The ON/OFF warmer switch(s) are located on the front of the hood. Test Procedure: 1. Disconnect the brewer from the power source. 2. Viewing the switch from the back, remove the red wire from the upper terminal and the black wire from the center terminal. 3. ...

  • Bunn VP17A - page 12

    Page 12 TANK HEATER Location: The tank heater is located inside the tank and secured to the tank lid. Test Procedures: 1. Disconnect the brewer from the power supply. 2. With a voltmeter, check the voltage across the black and red wire. Connect the brew to the power source. The indication must be 220 to 240 volts ac. 3. Disconnect the brewer from t ...

  • Bunn VP17A - page 13

    Page 13 SERVICE (cont.) 10860.1 071598 THERMAL CUT-OFFS FIG. 8 THERMAL CUT-OFFS P1262 Location: The thermal cut-offs are located inside the hood connected to the tank heater terminals. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the thermal cut-off from the terminal on the black lead of the ready light wiring harn ...

  • Bunn VP17A - page 14

    Page 14 P1167 FIG. 11 WARMER ELEMENT TERMINALS WARMER ELEMENT(S) Location: The warmer element(s) is located under the warmer plate. Test Procedures: 1. Disconnect the brewer from the power source. 2. With a voltmeter, check voltage across the red wire to the terminal block and white/red, brown/black or violet wire to the "ON/OFF" switch, ...

  • Bunn VP17A - page 15

    Page 15 10860.1 091300 ...

  • Bunn VP17A - page 16

    Page 16 10860.1 091300 ...

  • Bunn VP17A - page 17

    Page 17 10860.1 091300 ...

Manufacturer Bunn Category Coffeemaker

Documents that we receive from a manufacturer of a Bunn VP17A can be divided into several groups. They are, among others:
- Bunn technical drawings
- VP17A manuals
- Bunn product data sheets
- information booklets
- or energy labels Bunn VP17A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bunn VP17A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bunn VP17A, service manual, brief instructions and user manuals Bunn VP17A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bunn VP17A.

A complete manual for the device Bunn VP17A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bunn VP17A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bunn VP17A.

A complete Bunn manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bunn VP17A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bunn VP17A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bunn VP17A, that we can find in the current document
3. Tips how to use the basic functions of the device Bunn VP17A - which should help us in our first steps of using Bunn VP17A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bunn VP17A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bunn VP17A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bunn VP17A?

Use the form below

If you did not solve your problem by using a manual Bunn VP17A, ask a question using the form below. If a user had a similar problem with Bunn VP17A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)