    Shown with manual double timer contr ol system T echnical specifications Installation instructions Operating instructions Maintenance IPSO - USA 3101 South Haven Highway 77, Suite A Panama City, FL, 32405 Phone: (850)271-8486 OWNER'S MANUAL 50 lb. DR LAUNDR Y DR YER DR50 - USA THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER MAN DR2050 (ECN ) ...

  • IPSO DR50 - page 2

    Page 2 IMPORTANT NOTICES—PLEASE READ For optimum efficiency and safety, we recommend that you read the m anual before operating the equipment. Store this manual in a file or binder and keep for future reference. WARNING: Purchaser must post the following notice in a prominent location: WARNING : For your safety, the information in this manual mus ...

  • IPSO DR50 - page 3

    Page 3 ATTENTION: L’ACHETEUR DOIT PLACER L’AVERTISSEMENT SUIVANT DANS UN ENDROIT CLAIR ET VISIBLE: ATTENTION: L’ACHETEUR DOIT PLACER L’AVERTISSEMENT SUIVANT DANS UN ENDROIT CLAIR ET VISIBLE: AVERTISSEMENT. Assurez-vous de bien suivre les instructions donnees dans cette notice pour reduire au minimum le risque d’incendie ou d’explosion o ...

  • IPSO DR50 - page 4

    Page 4 WARNING: To avoid fire hazard, do not dry articles containing foam rubber or similar texture materials. Do not put into this dryer flammable items such as baby bed mattresses, throw rugs,undergarments (brassieres, etc.) and other items which use rubber as padding or backing. Rubber easily oxidizes causing excessive heat and possible fire. Th ...

  • IPSO DR50 - page 5

    Page 5 IPSO DRYER WARRANTY IPSO warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of two (2) years from the date of sale thereof to an original purchaser for use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than two ...

  • IPSO DR50 - page 6

    Page 6 Contents Safety Instructions .............................................................................. 2-4 Cissell Dryer Warranty ........................................................................ 5 Table of Contents ................................................................................ 6 Symbols ........................ ...

  • IPSO DR50 - page 7

    Page 7 Rotation in two directions Rotation dans les deux sens Drehbewigung in zwei Richtungen Movimiento rotativo en los dos sentidos Caution Attention Achtung Atencion; precaucion Direction of rotation Sens de mouvement continu De rotation Drehbewegung in Pfeilrichtung movimiento Giratorio o rotatorio en el sentido de la flecha The following symbo ...

  • IPSO DR50 - page 8

    Page 8 Unpacking/General Installation (All Dryers) Upon arrival of the equipment, any damage in shipment should be reported to the carrier immediately. Upon locating permanent location of a unit, care should be taken in movement and placement of equipment. See outline clearance diagrams for correct dimensions. Remove all packing material such as: t ...

  • IPSO DR50 - page 9

    Page 9 Unpacking/General Installation (All Dryers) The dryer is so designed that when an operator opens the dryer door, the basket and exhaust fan stop. You can expect fast drying from the laundry dryer. Hot, dry air is properly and effectively moved through the basket and exhausted through a lint trap to the atmosphere. The dryer comes equipped wi ...

  • IPSO DR50 - page 10

    Page 10 50 lb. Dryer Dimensions - Standard Gas, Steam and Electric Heated s n o i t a c i f i c e p Se r u s a e M . S . U c i r t e M e r u s a e M y t i c a p a C ) n e n i L y r D ( . s b l 0 5g k 7 . 2 2 t e k s a B r e t e m a i Ds e h c n i 3 3m m 0 4 8 h t p e Ds e h c n i 2 3m m 5 1 8 e m u l o Vt f 8 . 5 1 3 m 0 5 4 . 3 t e n i b a C t h g ...

  • IPSO DR50 - page 11

    Page 11 DR50 Dryer Dimensions - Gas (Illustration) 34.8 7“ (880 m m ) 33.0 7“ (840 m m ) 3 4 . 8 7 “ ( 8 9 0 m m ) 49.5 “(1260 mm) 12 . 2“ ( 3 1 0 mm ) 9 .25 “( 235 m m) 6. 3“(1 60 mm) 12 .1 “(3 07 mm ) EXHAUST 16 . 3 3“(41 5 m m ) 9.1“ (2 30 m m ) ELECT R I C BOX C O N. 5 “ ( 126 mm) 4.5“ (21 5 mm ) Electric In le t St eam ...

  • IPSO DR50 - page 12

    Page 12 Electric connection The connection needs to be made in the wiring box at the back. Remove the coverplate (G) in order to reach the connection clamps. The connection cable needs to be brought in through the swivel (H) on the side of the wiring box. It is necessary to ground the dryer for your personal safety and to ensure a good operation. 1 ...

  • IPSO DR50 - page 13

    Page 13 The gas supply pipe should be connected to the gas tap (I), which is on the right next to the wiring box on the back. It is very important to have the connections done by a qualified technician, in order to make sure that the installation is effected in accordance with the prevailing standards and instructions. The dryer should be connected ...

  • IPSO DR50 - page 14

    Page 14 Gas Piping Installation 1 . The installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code as, ANSI Z223.1 or the CAN/CGA- B149, Installation Codes. 2 . Check identification nameplate for type of gas for dryer. 3 . Check the altitude of dryer. 4 . Check with utilities company for proper gas ...

  • IPSO DR50 - page 15

    Page 15 Gas Piping Installation (Illustrations) The dryer and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (.04 bar). The dryer must be isolated from the gas supply piping system by closing it's individual manual shutoff ...

  • IPSO DR50 - page 16

    Page 16 The size of the gas service pipe is dependant upon many variables, such as tees, lengths, etc. Specific pipe size should be obtained from the gas supplier. Refer to the “Gas Pipe Size” chart in this manual for general gas pipe size information. CAUTION: Gas loop piping must be installed as illustrated to maintain equal gas pressure for ...

  • IPSO DR50 - page 17

    Page 17 Gas Pipe Size Chart TOTAL BTU/HR (for LP Gas correct total BTU/HR below by multiplying by .6) TOTAL KCAL HOUR GAS PIPE SIZE FOR 1000 BTU (250 KCAL) NATURAL GAS AT 7” (17.5 MM) W.C. PRESSURE In figuring total length of pipe, make allowance for tees and elbows. (150 ft.) 45,72 m (125 ft.) 38,1 m (100 ft.) 30,48 m (75 ft.) 22,86 m (50 ft.) 1 ...

  • IPSO DR50 - page 18

    Page 18 Dryer Installation With Multiple Exhaust For Exhaust Duct less than 14 feet (5 m) and 2 elbows equivalent and less than 0.3 inches (8 mm) static pressure. DR YER EXHAUSTS Area of section “A-A” must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe. ( See chart below. ) DR50 No. of Dryers Duct Diameter (in inches) ...

  • IPSO DR50 - page 19

    Page 19 Dryer Installation with Multiple Exhaust For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and more than 0.3 inches (8 mm) static pressure. (See illustration on page 21.) 1 . Make-up air from outside building may enter enclosure from top or side walls. (See Dryer Make-Up Air Chart) 2 . Use constant diameter duct with area equ ...

  • IPSO DR50 - page 20

    Page 20 Suggested Minimum Dryer Make-up Air Requirements Dryer Dryer Pocket Maximum Air Flow Duct Size For Required Make-up Model Capacity Rate per Pocket Service Connection Air Area per Pocket lb kg cfm m3/h inch mm sq. inch cm2 C 30 30 13.6 700 1 190 8 203 135 871 C 30 E/S 30 13.6 400 680 6 153 77 497 C 30 ST 30 13.6 450 765 6 153 87 561 C 50 50 ...

  • IPSO DR50 - page 21

    Page 21 Dryer Installation With Separate Exhaust (Preferred) For ductwork less than 14 feet (5 m) and 2 elbows equivalent and less than 0.3 inches (8 mm) static pressure: NEVER exhaust the dryer into a chimney. NEVER install wire mesh screen over the exhaust or make-up air area. NEVER exhaust into a wall, ceiling, or concealed space. 1 . Make-up ai ...

  • IPSO DR50 - page 22

    Page 22 Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air flow to the inlet of ...

  • IPSO DR50 - page 23

    Page 23 Rules for Safe Operation of Dryer 1 . Be sure your dryer is installed properly in accordance with the recommended instructions. 2. CAUTION Be safe—shut main electrical power supply and gas supply off externally before attempting service. 3. CAUTION Never use drycleaning solvents: gasoline, kerosene, or other flammable liquids in the dryer ...

  • IPSO DR50 - page 24

    Page 24 NOTE: All dryers manufactured are equipped with the DSI (direct spark ignition) modules. These are designed to increase dryer efficiency and to reduce dryer operating costs. The main burner is directly ignited from a spark electrode. A burning flame provides an electrical path for a small amount of sensing current to allow gas valve operati ...

  • IPSO DR50 - page 25

    Page 25 DIRECT SPARK IGNITION OPERATION FLOW CHART The DSI module is powered by a 24 volts AC suppled by a step-down trans- former in series with eight safety interlocks: A. Timer switching device (1) B . Main door and lint door switches (2) C . Sail switch (1) D . Under basket and burner housing thermal safety switches (2) E . Variable thermostat ...

  • IPSO DR50 - page 26

    Page 26 General Maintenance GENERAL MAINTENANCE 1. Clean lint trap daily. Remove lint before or after each day of operation. A clean lint trap will increase the efficiency of the dryer and the moisture-laden air will be exhausted outside more quickly. 2. Keep basket and sweep sheets clean. Clean as often as needed. The basket and sweep sheets are a ...

  • IPSO DR50 - page 27

    Page 27 7 . Periodically clean and examine exhaust system. 8 . Keep dryer area clean and free of gasoline, combustible materials and other flammable liquids or vapors. 9 . Do not obstruct the flow of combustion (make-up) air and ventilating air. 1 0 . Check gas pressure periodically. General Maintenance GENERAL MAINTENANCE (continued) ...

  • IPSO DR50 - page 28

    Page 28 OPERA TING INSTRUCTION - DOUBLE TIMER 1 . After loading the dryer with water washed clothes, close the loading door. 2 . Turn the 60 minute drying (heat) timer to the desired time. 3 . Turn the 60 minute cooling (air) to the desired time. 4 . Select the temperature desired: Low, Medium, or High. HIGH HEAT 175° F (80° C) exhaust temperatur ...

  • IPSO DR50 - page 29

    Page 29 R e f . Part N o . Description N o . 1 CSA50037WH Jacket fas/electric (white) 1 CSA-50050WH Jacket steam (white) 2 TU7733 Screw self drilling 8-18 X 1/2" 3 CA-12073-0 Top panel 4 CSA-11546-0 Cover plate (non-coin models) 5 TU7733 Screw self drilling 8-18 X 1/2" 6 CSA-01435-0 Coin chute w/a 7 EA-00650-0 Microswitch door 8 CA-12070- ...

  • IPSO DR50 - page 30

    Page 30 CSA-01423WH Complete control door assy. Note : Door rod assy. is not part of above complete assy. R e f . Part N o . Description No. 1 CSA-01424WH Control door assy. 2 CA-00857-0 Trim - Control door 3 CA-11941-0 Cam lock-Control door 4 CA-00121-0 Lock - Control door 5 CA-00119-0 Key - Control door 6 CA-13098-0 Gasket 7 CA-10085-0 Support ro ...

  • IPSO DR50 - page 31

    Page 31 R e f . Part N o . Description N o . 1 SB-00915-0 Screw self drilling #10-16 X 5/8 2 CSA-01566WH F ront panel, welded assy.-Coin 2 CSA-01565WH Front panel, welded assy-OPL 3 TU3213 Pop Rivet PVD doorlocker 4 TU2876 Latch strap 5 CA-00676 I n s u l a t i o n 6 SB-00924-0 Screw 4-40*3/8 taptite 7 SB-00938-0 Washer 4 external tooth 8 CA-00699- ...

  • IPSO DR50 - page 32

    Page 32 R e f . Part N o . Description N o . 1 EA-00607-0 Thermostat knob 2 CA-13213-0 Thermostat bracket 3 EA-00606-0 Thermostat 4 CA-13215-0 Thermostat bracket adapter 5 TU3624 Screw 6 - 32 X 1/4" 6 TU7733 Screw - self drilling 8 - 18 X 1/2" 7 EA-00434-0 Clip - 3/8" spring 8 EA-00608 - 0 Grommet / rubber 9 CA-13214-0 P l a t e 1 0 ...

  • IPSO DR50 - page 33

    Page 33 2 4 5 3 1 2 1 2 2 6 7 WIRE BOX ASSEMBL Y R e f . Part N o . Description N o . CSA-01608WH Wire box door assy complete 1 TUT316 Light LED 24V 2 EA-11614-0 Timer-manual 24V - 60 min. complete 3 EA-00619-0 Switch - start 4 CA-13170-0 Overlay- dual timer non-rev 5 CSA-01608WH Wire box door assy. 6 SB-00865-0 Screw-self drilling #6-20 X 12" ...

  • IPSO DR50 - page 34

    Page 34 R e f . Part N o . Description N o . MSD-00864WH Complete door assy (consists of items 1 thru 9 only) 1 MD-00362-0 Door Glass - clear 2 MD-00354-0 Gasket - door glass - straight 3 TU3163 Catch Pin 4 TU4840 Crown nut 5 MD-00337-0 Magnet - read switch 6 MD-00338-0 Ga sk e t - door rim 7 TU2874 Basket door handle 8 MSD-00858-WH Basket door 9 T ...

  • IPSO DR50 - page 35

    Page 35 R e f . Part N o . Description N o . CSA-01430WH Complete Asm - WMC50 OPL CSA-01428WH Complete Asm - WMC50 Coin 1 CSA-01099WH Lint door w/latch holes(white) OPL 1 CSA-01429WH Lint door w/lock holes(white) Coin 2 CSA-00838-0 K i c k p l a t e 3 SB-00949-0 Fastener plastic kickplate 4 CA-12029-0 Insulation lower frontpanel WMC50 5 SB-00915-0 ...

  • IPSO DR50 - page 36

    Page 36 R e f . Part N o . Description N o . CSA-01541-0 Basket & Spyder Asm.WMC50 - S.S. CSA-01632-0 Basket & Spyder Asm.WMC50 - Galv. 1 CSA-01540-0 Stainless steel basket assy. 1 CSA-01631-0 Galvanized basket assy. 2 CSA-00822-0 Spider assy. 3 TU5439 Screw-cap 5/16-18 X 3/4" 4 TU2814 Lock washer 5/16" 5 SB-00843-0 Washer fender ...

  • IPSO DR50 - page 37

    Page 37 R e f . Part N o . Description N o . 1 CA-12073-0 Top panel 2 TU7733 Screw self drilling 8-18*1/2" 3 CA-11936-0 Cover plate 4 CA-12016-0 Backpanel 5 TU7733 Screw self drilling 8-18*1/2" REAR VIEW ...

  • IPSO DR50 - page 38

    Page 38 R e f . Part N o . Description N o . CSA-01334-0 Sail switch assy. complete 1 CA-11854-0 Bracket sailswitch 2 SB-00955-0 Screw phillips #4 X 3/4" 3 TU7733 Screw self drilling 8-18*1/2" 4 CSA-01669-0 Sailswitch plate and rod assy. 5 SB-00954-0 Clip-twin-Tinnerman 6 EA-00618-0 Microswitch AIR SWITCH ASSEMBL Y ...

  • IPSO DR50 - page 39

    Page 39 R e f . Part N o . Description N o . 1 DA-11912-0 Pulley - basket 2 Part of pulley 3 DA-11914-0 Ke y 4 C249 H e x nut 5/16-18" 5 SB-00876-0 Stud - 5/16 - 18" 6 DSA-00728-0 Bearing box assy. 7 TU4787 Hex nut 3/8-16" 8 VSB134 Lock Washer 3/8" 9 IB140 Washer 3/8" 1 0 IB140 Washer 3/8" 1 1 IB139 Screw 3/8-16*1-1/4& ...

  • IPSO DR50 - page 40

    Page 40 R e f . Part N o . Description N o . 1 DA-00494-0 Fan motor 1/2 HP 115/208/230/60/50/1 1 DA-00447-0 Fan motor 1/2 HP 220/380/60/50/3 2 TU2814 Lock washer 5/16" 3 TU5439 Screw-cap 5/16-18 X 3/4" 4 DSA-00782-0 Motor mount w/a - non-rev. 5 SB-00842-0 Nut, grip, Tinnerman 6 SB-00836-0 Screw, phillips, pancake head 7 DSA-00773-0 Fan (1 ...

  • IPSO DR50 - page 41

    Page 41 R e f . Part N o . Description N o . 1 DA--11904-0 Idler pulley 11" 2 DA-00917-0 Basket belt - non-reversing - AX70 2 DA-00497-0 Basket belt -reversing - AX71 3 FB124 Screw 5/16-18*1" 4 VSB130 Washer 5/16" 5 CA-12059-0 Idler adjusting plate 6 DA-00518-0 Bearing 7 DA-00517-0 Housing - idler bearing 8 TU2814 Lock washer 5/16&qu ...

  • IPSO DR50 - page 42

    Page 42 R e f . Part N o . Description N o . ESA-00966-0 Wire box assy, rear, gas - 115V - 2 timer ESA-00974-0 Wire box assy, rear, gas - 208/240V - 2 timer 1 CA-11935-0 Rear wiring box 2 SB-00868-0 Bushing, insulating 7/8" 3 SB-00867-0 Bushing, insulating 1/2" 4 TU7733 Screw self drilling 8-18 X 1/2" 5 GA-00765-0 Ignitor ram III DSI ...

  • IPSO DR50 - page 43

    Page 43 R e f . Part N o . Description N o . GSA-0778-0 Comp. assy. - Nat. gas 1 GSA-00255-0 Housing gas burner 2 TU11613-0 Lock washer 10 external tooth 3 SB-00831-0 Screw 10-32*3/8" 4 GSA-00756-0 Gas burner 5 OP308 Nipple - 1/2" X 4" 6 CA11878-0 Bracket -pipe 7 GA-00770-0 Gas valve 24V 1/2"(Nat.gas) 8 TU7733 Screw self drillin ...

Manufacturer IPSO Category Clothes Dryer

Documents that we receive from a manufacturer of a IPSO DR50 can be divided into several groups. They are, among others:
- IPSO technical drawings
- DR50 manuals
- IPSO product data sheets
- information booklets
- or energy labels IPSO DR50
All of them are important, but the most important information from the point of view of use of the device are in the user manual IPSO DR50.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IPSO DR50, service manual, brief instructions and user manuals IPSO DR50. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IPSO DR50.

Similar manuals

A complete manual for the device IPSO DR50, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IPSO DR50 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IPSO DR50.

A complete IPSO manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual IPSO DR50 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IPSO DR50, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IPSO DR50, that we can find in the current document
3. Tips how to use the basic functions of the device IPSO DR50 - which should help us in our first steps of using IPSO DR50
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IPSO DR50